Building Tech 02 - Structural

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views8 pages

Building Tech 02 - Structural

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

A B C A B C

6.30 6.30
3.00 3.30 3.00 3.30

1.40 1.90

F2C2 FTB F3C2 RB


4 4
2.09

2.09
2.00

2.00
WF

FTB

RB
RB
FTB
F1C1 F2C1
FTB FTB RB RB
3 3

1.35

1.35
WF
F1C1 el ev .@
+0 .4 0 m

FTB RB

FTB
FTB

elevation @ +0.50m

FTB
4.30

4.30

RB

RB
RB
elevation @ +0.50m

10.39
10.30

10.30
11.19

F1C1 F1C1 F2C1


FTB FTB RB RB
2 2

6.95

6.95
10mm ∅ TEMP. BARS sp @ 0.50
elevation @ +0.50m
M O.C. INTERNAL FLOORING
0.10 M THICK SLAB ON FILL

FTB
F TB
FTB

RB

RB
elevation @ +0.50m
4.00

4.00

RB
F1C1 F1C1 F2C1
RB RB
1 F TB FTB 1
0.80

WF
3.00 3.30
3.00 3.30

foundation plan roof beam plan


SCALE 1 : 100 M SCALE 1 : 100 M

PREPARED FROM THE OFFICE OF: ARCHITECT: PRC NO. PROJECT TITLE: OWNER/s: DESIGN BY: SHEET CONTENT/S: SHEET NO.
VALIDITY R. ANG D. VELASCO
ONE STOREY residential
PTR NO. M.A. MEJIA J. VALEN UELA
FOUNDATION PLAN S
ARCHITECTURAL DESIGN CONSULTANCY SERVICES DATE ISSUED: building D. A UINO P. CALIBUSO ROOF BEAM PLAN
AR. ROMMEL A. ANG MICHELLE L. ANG
ARCHITECTURAL DESIGN + CONSULTANCY SERVICES PLACE ISSUED: DAGUPAN CITY LOCATION: DATE: FEBRUARY
ST RUCT URAL NOT ES
A B C
CONCRETE REBARS

1. All cast-in-place concrete shall conform to ACI CODE 318-99 Building Code Requirements for Structural Concrete.
6.30
3.15 3.15 2. Unless otherwise indicated/noted, all concrete sections (e.g. slabs, beams, footings) should have a minimum of
3000psi 28-day compressive strength assuming no honeycomb.

3. All footings are design rest on undisturbed, firm, soil with a min. bearing capacity of 200 kpa, no footings shall
4 rest on fill.
RUSS O2

1.87
2.05

4. Unless otherwise noted, The following minimum concrete cover shall be provided for reinforcement. 4.175mm for
RUSS O2 concrete permanently exposed to earth 4.240mm for concrete exposed to weather with bar dia. Unless otherwise
specified all deformed reinforcing bars shall conform to ASTM A-615, GD40
3
5. Unless otherwise noted all continuous reinforcing bars shall have a minimum of 36d splices and always located at
compression side.

6. Excessive evaporation on fresh concrete specially suspended slab shall be controlled by any means acceptable for
4.30

structural slab.

10.43
7. Place additional dowel for discontinuous pouring with size and spacing acceptable to the supervising engineer.
O 1

O 1

O 1
11.18

8. Cement shall be Portland not blended brand approved by the TPC representative conforming to ASTM 150.
8.56
2
R U S S

R U S S

R U S S

9. Fine and course aggregates shall be well graded crushed stone conforming to ASTM C33 Having the following min.
size: 10.125mm (1”) for plain concrete (non-reinforced) and footing 10.220mm (3/4”) for Reinforced concrete section.

10. For Two-way slab bars along the shorter span shall be placed below the bars along longer span at midspan, and
4.09

over the longer span near the support . Unless otherwise indicated or shown in detail the spacing of the bars at
column strip can be approximately 1-1/3 that of the middle strip but not greater than 2-1/3 times the thickness
of slab.

1 STRUCTURAL STEEL SECTIONS


0.75

3.28 3.20 11. Unless otherwise noted, all steel sections and non-shrink grout shall conform to the following ASTM standards:

FASCIA FLASHING B R AS SIGNA ION IN. S R NG H


Column A36 250 mpa Tensile
2" X 3" C-PURLINS
spaced @ 0.60 m O.C. Beam A36 250 mpa Tensile
Anchor Bolts A325/449 600 mpa Tensile
Non-shrink Grout C1107 800 mpa Compressive

12. All welding shall conform to AWS D01.1 (Structural steel welding) using E70xx electrodes. Unless otherwise noted
roof framing plan provide a min. fillet weld size equivalent to the thickness of the base metal to be connected for thickness 6mm
below and reduce 2mm for thickness above 6mm.
SCALE 1 : 100 M 13.All major structural steel members shall be coated with approved standard red oxide epoxy primer. Unless
otherwise specified, all filler material shall have a minimum yield strength of 60 ksi. All moment connections (e.g.
Column to column connection, Beam to beam longitudinal or laterally connected) shall be full welded all around and
shall be reflected in the structural details.

PREPARED FROM THE OFFICE OF: ARCHITECT: PRC NO. PROJECT TITLE: OWNER/s: DESIGN BY: SHEET CONTENT/S: SHEET NO.
VALIDITY R. ANG D. VELASCO
ONE STOREY residential
PTR NO. M.A. MEJIA J. VALEN UELA
ROOF FRAMING PLAN S
ARCHITECTURAL DESIGN CONSULTANCY SERVICES DATE ISSUED: building D. A UINO P. CALIBUSO STRUCTURAL NOTES
AR. ROMMEL A. ANG MICHELLE L. ANG
ARCHITECTURAL DESIGN + CONSULTANCY SERVICES PLACE ISSUED: DAGUPAN CITY LOCATION: DATE: FEBRUARY
1.50

0.60 0.30 0.60


NATURAL GROUND LINE
NATURAL GROUND LINE 1.00 4-16mm ∅ VERTICAL RSB

4-16mm ∅ VERTICAL RSB 0.20 0.80 10mm ∅ LATERAL TIES


spaced @ 50mm, 4-100mm,

0.60
10mm ∅ LATERAL TIES COLUMN - 02 (C2) REST @ 200 mm O.C.
spaced @ 50mm, 4-100mm, see details

1.20
10-16mm ∅ BASE REST @ 200 mm O.C.

0.35
RSB BOTH WAYS 8-16mm ∅ BASE RSB

1.20

1.50
8-16mm ∅ BASE BOTH WAYS
10-16mm ∅ BASE RSB
RSB BOTH WAYS

0.30

1.50

1.50
BOTH WAYS

0.30
1.00
FOOTING TIE BEAM
COLUMN - 01 (C1) FOOTING TIE BEAM FOOTING TIE BEAM
see details

0.35
0.60

0.30
0.30
FOOTING CONCRETE
COVER
FOOTING CONCRETE
COVER
P L A N S E C T I O N
P L A N S E C T I O N

F1C1 details F2C2 details

1.50

1.20 0.30
NATURAL GROUND LINE
NATURAL GROUND LINE 1.00 4-16mm ∅ VERTICAL RSB

4-16mm ∅ VERTICAL RSB 10mm ∅ LATERAL TIES


0.20 0.80
spaced @ 50mm, 4-100mm,
0.60

10mm ∅ LATERAL TIES COLUMN - 02 (C2) REST @ 200 mm O.C.


10-16mm ∅ BASE
spaced @ 50mm, 4-100mm, see details
RSB BOTH WAYS

1.20
REST @ 200 mm O.C.

0.30
8-16mm ∅ BASE RSB

1.20

1.50
8-16mm ∅ BASE BOTH WAYS
10-16mm ∅ BASE RSB
RSB BOTH WAYS
0.30

1.50

1.50
BOTH WAYS

1.00
FOOTING TIE BEAM

0.70
FOOTING TIE BEAM
COLUMN - 01 (C1)
0.60

0.30
see details

0.30
FOOTING CONCRETE
COVER
FOOTING CONCRETE
COVER
P L A N S E C T I O N
P L A N S E C T I O N

F2C1 details F3C2 details

ISOLATED foOTING DETAILS


SCALE 1 : 30 M

PREPARED FROM THE OFFICE OF: ARCHITECT: PRC NO. PROJECT TITLE: OWNER/s: DESIGN BY: SHEET CONTENT/S: SHEET NO.
VALIDITY R. ANG D. VELASCO
ISOLATED FOOTING DETAILS
ONE STOREY residential
PTR NO. M.A. MEJIA J. VALEN UELA FC D
F C D
s
s
S
ARCHITECTURAL DESIGN CONSULTANCY SERVICES DATE ISSUED: building D. A UINO P. CALIBUSO F C D s
AR. ROMMEL A. ANG MICHELLE L. ANG F C D s
ARCHITECTURAL DESIGN + CONSULTANCY SERVICES PLACE ISSUED: DAGUPAN CITY LOCATION: DATE: FEBRUARY
0.30 0.20

TEMPERATURE BAR 10mm ∅


spaced @500mm O.C. B.W.

0.30
0.30
GRAVEL BEDDING G RAVE L FI L L
COMPACT EARTH
C1 C2
COLUMN 01 COLUMN 02

VERTICAL BARS : 4-16mm∅ RSB VERTICAL BARS : 4-16mm∅ RSB


LATERAL TIES : 10mm∅ LATERAL TIES sp. LATERAL TIES : 10mm∅ LATERAL TIES sp.
@ 50mm, 4 @ 100 mm, @ 50mm, 4 @ 100 mm,
SLAB ON FILL DETAILS REST @ 200mm O.C. REST @ 250mm O.C.

SCALE 1 : 30 M
COLUMN DETAILS
SCALE 1 : 20 M

10mm ∅ BASE BARS


SP.@ 300mm O.C.

CONTINUOUS CONTINUOUS
F.F. LINE
0.30

BOTTOM BARS TOP BARS


10mm ∅ VERTICAL BARS
CONC. HOLLOW BLOCKS SP.@ 600mm O.C. MID SPAN RIGHT SUPPORT
BOTTOM BARS TOP BARS
0.30

0.60

10mm ∅ HORIZONTAL BARS LEFT SUPPORT STIRRUPS


SP.@ EVERY 3 LAYERS OF
CONC. HOLLOW BLOCKS
TOP BARS
VERIFY VERIFY VERIFY b TOP BARS
G. Line
L1/4 L1/4 L1/4 L1/4
4 - 12mm ∅ CONC. HOLLOW BLOCKS STIRRUPS
CONTINUOUS BARS

h
0.50

10mm ∅ BASE BARS BOTTOM BARS


SP.@ 300mm O.C.
4 - 12mm ∅ EXTERIOR SUPPORT INTERIOR SUPPORT CANTILEVER END
CONTINUOUS BARS
0.15

L2/5
L1/5 L1/5 L2/5
0.60
0.60 L1 L2 Lo
P L A N S E C T I O N

wall footing details TYPICAL beam details


SCALE 1 : 30 M SCALE NTS.

PREPARED FROM THE OFFICE OF: ARCHITECT: PRC NO. PROJECT TITLE: OWNER/s: DESIGN BY: SHEET CONTENT/S: SHEET NO.
VALIDITY R. ANG D. VELASCO
ONE STOREY residential SLAB ON FILL DETAILS
PTR NO. M.A. MEJIA J. VALEN UELA
WALL FOOTING DETAILS S
ARCHITECTURAL DESIGN CONSULTANCY SERVICES DATE ISSUED: building D. A UINO P. CALIBUSO COLUMN DETAILS
AR. ROMMEL A. ANG MICHELLE L. ANG TYPICAL BEAM DETAILS
ARCHITECTURAL DESIGN + CONSULTANCY SERVICES PLACE ISSUED: DAGUPAN CITY LOCATION: DATE: FEBRUARY
MARK DIMENSION SECTION SPACING OF
( mm ) b x h @SUPPORT @MIDSPAN 10 mm Ø STIRRUPS

3 - 16 mm Ø Bars 2 - 16 mm Ø Bars 1 - 50 mm, 4 - 100 mm,


RB 200mm x 300mm
rest @ 120 mm on center
2 - 16 mm Ø Bars 3- 16 mm Ø Bars

2 - 16 mm Ø Bars 2 - 16 mm Ø Bars 1 - 50 mm, 4 - 100 mm,


FTB 250mm x 350mm
rest @ 150 mm on center
2 - 16 mm Ø Bars 2 - 16 mm Ø Bars

beam details and schedule


SCALE NTS.
SPOT DETAILS - 2

0.60
0.60
0.60
SPOT DETAILS - 1 0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.63

0.73 0.65 0.65 0.65 0.65 0.65 0.65 0.80 0.80 0.80 0.80

0.77

TRUSS 01 DETAILS
SCALE 1 : 30 M

PREPARED FROM THE OFFICE OF: ARCHITECT: PRC NO. PROJECT TITLE: OWNER/s: DESIGN BY: SHEET CONTENT/S: SHEET NO.
VALIDITY R. ANG D. VELASCO
ONE STOREY residential
PTR NO. M.A. MEJIA J. VALEN UELA
BEAM DETAILS AND SCHEDULE S
ARCHITECTURAL DESIGN CONSULTANCY SERVICES DATE ISSUED: building D. A UINO P. CALIBUSO TRUSS DETAILS
AR. ROMMEL A. ANG MICHELLE L. ANG
ARCHITECTURAL DESIGN + CONSULTANCY SERVICES PLACE ISSUED: DAGUPAN CITY LOCATION: DATE: FEBRUARY
0.60
6mm thk G.I. Gutter 0.60
WIRE STRAINER 0.60
RIB-TYPE ROOFING
TEKSCREW WITH SILICONE SEALANT
RIB TYPE ROOFING TEKSCREW WITH SILICON SEALANT

2" x 3" C - PURLINS 2" x 3" C - PURLINS SP. @


0.60M ON CENTER

TRUSS 01 See Det


3" PVC PIPE DOWNSPOUT
WEB MEMBERS : 1 1/2" x 1 1/2"
x 1/4" ANGLE BAR

SPOT DETAIL - 1
TRUSS 01

FLASHING TOP & BOTTOM CHORD : 2"


x 2" x 1/4" ANGLE BAR
PARAPET WALL

ROOF 01 DETAILS
SCALE NTS
TEKSCREW WITH SILICONE
SEALANT
2" x 3" C - PURLINS
SPOT DETAILS - 2

TRUSS 01 See Det

RIB-TYPE ROOFING
1.13
1.50
1.50
SPOT DETAIL - 2 1.50
1.10
TRUSS 01

TRUSS 01
0.79 0.65 0.65 0.65
SPOT DETAILS SPOT DETAILS - 1
SCALE NTS 0.77

TRUSS 02 DETAILS
SCALE 1 : 30

PREPARED FROM THE OFFICE OF: ARCHITECT: PRC NO. PROJECT TITLE: OWNER/s: DESIGN BY: SHEET CONTENT/S: SHEET NO.
VALIDITY R. ANG D. VELASCO
ONE STOREY residential
PTR NO. M.A. MEJIA J. VALEN UELA SPOT DETAILS T ss
ROOF DETAILS
S
ARCHITECTURAL DESIGN CONSULTANCY SERVICES DATE ISSUED: building D. A UINO P. CALIBUSO TRUSS DETAILS
AR. ROMMEL A. ANG MICHELLE L. ANG
ARCHITECTURAL DESIGN + CONSULTANCY SERVICES PLACE ISSUED: DAGUPAN CITY LOCATION: DATE: FEBRUARY
6mm thk G.I. Gutter
WIRE STRAINER
TEKSCREW WITH SILICONE SEALANT
RIB TYPE ROOFING
2" x 3" C - PURLINS

TRUSS 01 See Det


3" PVC PIPE DOWNSPOUT
0.60
0.60
SPOT DETAIL - 1 RIB-TYPE ROOFING
TRUSS 02
TEKSCREW WITH SILICON SEALANT
2" x 3" C - PURLINS SP. @ 0.60M ON CENTER
FLASHING
WEB MEMBERS : 1 1/2" x 1 1/2" x 1/4" ANGLE BAR
PARAPET WALL
TOP & BOTTOM CHORD : 2" x 2" x 1/4" ANGLE BAR

TEKSCREW WITH SILICONE


SEALANT
2" x 3" C - PURLINS
TRUSS 01 See Det ROOF 01 DETAILS
SCALE NTS
RIB-TYPE ROOFING
SPOT DETAIL - 2
TRUSS 02

TRUSS 02

SPOT DETAILS
SCALE NTS

PREPARED FROM THE OFFICE OF: ARCHITECT: PRC NO. PROJECT TITLE: OWNER/s: DESIGN BY: SHEET CONTENT/S: SHEET NO.
VALIDITY R. ANG D. VELASCO
ONE STOREY residential
PTR NO. M.A. MEJIA J. VALEN UELA
SPOT DETAILS T ss S
ARCHITECTURAL DESIGN CONSULTANCY SERVICES DATE ISSUED: building D. A UINO P. CALIBUSO ROOF DETAILS
AR. ROMMEL A. ANG MICHELLE L. ANG
ARCHITECTURAL DESIGN + CONSULTANCY SERVICES PLACE ISSUED: DAGUPAN CITY LOCATION: DATE: FEBRUARY