0% found this document useful (0 votes)
2 views1 page

Data Collection

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views1 page

Data Collection

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Data Collection Data is collected from Time Savers, Nuferts 4 th edition, NBC - 2016, Karnataka Bye Laws of 2016

uferts 4 th edition, NBC - 2016, Karnataka Bye Laws of 2016 and 2017

Set Backs Group D


This category includes places where
Buildings upto 15 meters : A 5 - meter setback on all sides is typically required, according to the
7917

people gather for public purposes,


3245

Karnataka Building Bye - Laws 2017. For taller buildings ( above 11.5 meters ), the setbacks increase
2462

including transit stations and hubs for


incrementally.
3000 public transportation like road, rail, and
air stations.Assembly buildings are
designated as locations where large
11227

groups congregate, especially in urban


Yard at Topmost Yard at Topmost
9683

spaces for movement and transit


level of podium level of podium

Yard at ground Yard at ground


Coverage
F.S.I(Floor space index) = (Total built
2833
997

Plot boundary
level(min 2.5 m) Plot boundary level(min 3.5 m)
Plot boundary
up area on all floors) / (Plot area)
7052

Maximum permissible coverage =


Minimum Setbacks Required = A minimum of 3 meters in the
front and 2 meters at the rear, with side setbacks around 1.2 50.F.S.I value limits maximum build-
For buildings upto 16 meters height For buildings above 16 meters height
meters able area.
SCALE 1: 120
A2

Occupant Load Width of Passageways Lift Requirements


c) Assemby buildings like auditorium,theatres and cinemas - Corridoor width - 2.00m Every public building exceeding 1000 sq. metres and residential flats exceeding 2500sq.metres
Sl No. Type of Occupancy Occupant Load per 100 sq.m of Carpet Area
built-up area shall have lift or separate approach through a ramp (intended forthe differently-abled
D Assembly Buildings 166.6 Height and elderly) to each floor. The minimum cage dimensions of such lift shall be as follows:
The clear height of all rooms for human habitation shall not be less than 2.75 m mea-
In case of assembly occupancy, all rooms, toilets common areas connected to the sured from the surface of the floor to the lowest point of the ceiling provided that the Persons 6 8 10 13 16 20 25
assembly occupancy shall be included in the carpet area for calculating the occupancy minimum clear headway under any beam shall not be less than 2.4 m. In case of Load 408 Kg 544 Kg 680 Kg 884 Kg 1088 Kg 1360 Kg 1440 Kg
load. pitched roof, the average height of rooms shall not be less than 2.75 m. The minimum
clear head room under a beam or eaves shall be 2.4 m. D 1600 1700 1800 1700 1900 2150 2300
Size of Air Shaft
Interior Courtyards (i) Clear internal width 1.10 m (ii) Clear internal depth 2.00 m (iii) Entrance door width 0.90 m
Height of Building Size of Ventilation Shaft Minimum Size of Shaft
Every interior courtyard shall be raised at least 150 mm above the determining ground Lift should be provided for all buidlings exceeding 15.0m meters in height.The main public lifts shall
Upto 10.0 m 1.2 sq.m 0.9 m level and shall be satisfactorily drained. not be used as fire escapes in case of any emergencies.

Ramp Ratio Toilet Requirements Sl No Sanitary Unit For Male For Female
1:10,1:12 ramps are 1:8-1:10 - Vehicular road 1:12 - Pedestrian road Public Toilets One per 100 persons upto 400 Two for 100 persons upto 200
used. 1:20 - Wheelchair road 1: 20 - Ramp to be given On roads and for open areas : AT every 1 km, including parks, plaza, open air theatre, persons; for over 400 add at the persons; over 200 add at the
1. Water Closet
swimming area, car parks, fuel stations. Toilets shall be disabled - friendly and in 50 - rate of one per 250 persons or part rate of one per 100 persons or
Ideal slope is 1:10 50 ratio ( M / F ). thereof. part thereof.
Minimum ramp width should be 1200mm with a corri- 2. Urinals One for 50 persons or part thereof. Nil upto 6 persons, 4 for 71-100
1:10 Maintenance / Cleaning
door width of 1500mm and intermediate landings.The 3. Wash Basins One per WC / Urinals One per WC
ramp should be made of non-slippery material for grip The toilet should have both men and women attendants. Automatic cleaning cycle
and friction to prevent slippage. covering flush, toilet bowl, seat, wash basin, etc. Toilets should be open for 24 hours. 4. Ablution Taps One in each WC One in each WC

Bus Boarding Bays Turning Radius and Parking Size


Bus boarding bay with 100 m length. Parking bays with an inclination of 30 - 60 degrees Turning radius for Tourist buses = 12m, Turning radius for Local, Interstate buses = 9m
are preferred, as it does not occupy much turning radius for buses. 45 degrees is pre-
ferred as the distance from the bay is only 19 m, saving space. Turning Radius

Angled 45 degrees

A longer turning radius creates a more The slip angles of wheels are minimuzed by
Car Turning Radius Bus Turning Radius rounded corner - allowing the bus to enter assuming that the speed of the vehicle for
Angled 60 degrees and exit the driveway more quickly without the minimum radius turn is 10 mph or less
Parking Slot Sizes disturbing traffic in adjacent lanes. for buses.

Turning Circuit Carriage Way

Angled 90 degrees Car Dimensions Bike Dimensions

Minimum distance between two buses parked


Bus Dimensions Auto Dimensions together should be 600 m in a parking lane.

Parking Standards Seating Spaces SL.


SPACES
LITERATURE CASE STUDY 1 LITERATURE CASE STUDY 2
Baramati CMBT STANDARDS FINAL AREA
NO
Seating - in andaround the bus
Sl.No 90 60 45 Sl.No 90 60 45 1 Reception 50 sq.m (15-20 people) 2 sq.m/person 10 sq.m
terminal complex - shall be planned 2 Lobby 20 sq.m
90 sq.m
1 sq.m/person 1 x 30 people = 30 sq.m
a 13 12.75 11.5 a 5 4.8 4.5 to cater to a minimum of 30 % of all 3 Waiting Area 20 sq.m 30 sq.m 30 sq.m 30 sq.m
b > = 12 > = 10 > = 7.5 b >=5 > = 4.5 >=4 passengers in the facility.
4 Baggage Check 20 sq.m 30 sq.m 20 sq.m 50 sq.m
c 26 23.75 20.53 c 10 8.7 7.6
d 3.5 3.5 3.5 d 2.25 2.25 2.25
Lighting 5 Security Check 2 x desk space(4.65/person) 80 sq.m 100 sq.ft/person 30 sq.m
6 Enquiry Desk 50 sq.m 2 sq.m/person 20 sq.m
e 3.5 4.04 4.95 e 2.25 2.6 3.18 Follows APTA 2009, includes contin- 7 Tourist Enquiry 75 sq.m (25 people) 20 sq.m 15 sq.m
uous lighting, standby lighting,
8 Ticket Booking - Bus 1 per 8 pupils 20 sq.m
Bus Parking( Long Term Parking ) Car Parking( Long Term Parking ) mobile lighting
9 Prepaid Taxi Counter 10 sq.m 10 sq.m 20 sq.m
10 Prepaid Auto Counter 50 sq.m (15-20 people) 2 sq.m/person 20 sq.m

Idle Parking Standards 11 Security Room 20 sq.m 1 sq.m/person 30 sq.m


12 Admin Room 60 sq.m 2 sq.m/person 40 sq.m
Bus boarding bay with 100 m length. Parking bays with an inclination of 30 - 60
13 Staff Meeting Room 180 sq.m(80 people) 50 sq.m
degrees are preferred, as it does not occupy much turning radius for buses. 45
14 Toilets 1 per 8 pupils 50 sq.m
degrees is preferred as the distance from the bay is only 19 m, saving space.
15 Cloak Room 30 cm x 30 cm / unit 150 sq.m
16 Automated Ticket Kiosks 20 sq.m 10 sq.m 15 sq.m
17 Control Room 1355 sq.m + 670 sq.m(kitchen) 2 sq.m/person 35 sq.m
18 Medical Room 30 sq.m 2 sq.m/person 30 sq.m
19 ATM 2 sq.m/person 15 sq.m
20 Common Waiting Room 40 sq.m (30 people) 100 sq.m
21 Toilets 50 sq.m (15-20 people) 2 sq.m/person 50 sq.m
22 Male Waiting Room 20 sq.m 50 sq.m (15-20 people) 1 sq.m/person 100 sq.m
23 Toilets 60 sq.m 50 sq.m
24 Female Waiting Room 180 sq.m(80 people) 100 sq.m
25 Toilets 1 per 8 pupils 50 sq.m
26 Curio Shop 30 cm x 30 cm / unit 40 sq.m
27 Convenince Store 20 sq.m 10 sq.m 45 sq.m
Car Idle Parking Bus Idle Parking 28 Snack Bay / Deli 2.3 sq.m/person 50 sq.m
29 Restaurant Seating 72 sq.m 2.75 sq.m/person 200 sq.m

Staircase Standards 30 Lobby 2 sq.m/person 30 sq.m


31 Reception 50 sq.m (15-20 people) 2 sq.m/person 10 sq.m
The travel distance between 2 staircases shall not be less than 60m according to NBC standards.Entrance to fire escape shall be 32 Kitchen 20 sq.m 1 sq.m/person 60 sq.m
seperated from the main staircase.Fire escapes shall be provided every 30m apart . 33 Storage 2 sq.m/person 20 sq.m
34 Waiting Areas 2 sq.m/person 12 sq.m for 6 people
35 Driver’s Cabin 1 per 8 pupils 40 sq.m
Normal Staircase Fire Staircase 36 Toilets 2 sq.m/person 50 sq.m
37 Bus Maintenance Shed 60 sq.m 60 sq.m 50 sq.m
Riser - 150mm,Tread - 300mm Riser - not more than 190mm,
38 Security Cabin 80 sq.m 75 - 120 sq.m 12 sq.m
Min. width - 1200mm Tread - not more than 250mm
39 Lifts 6 sq.m
Handrail height - 90mm Handrail height - 100-120mm
40 Staircase 30 sq.m
Passage head room - It should be a straight flight
2200mm Total 5000 sq.m
Taniya Sara Philip
Data Collection S9 Batch C|CAT20AR120