1 General
All Flarm units need periodically firmware update. The updates are normally carried out by users after
using of PC or SD card. A special case will happen at the end of February 2008, as all Flarm units
will need a compulsory firmware update; otherwise the units will not be able to operate any more.
This document has been prepared to make the update campaign as much as stress less and easy.
Necessary procedures and also HW requirement are described in details.
Note!
Firmware upgrade to flight recorder with limited IGC approval can be done exclusively through
authorized personal. For more details contact your local distributor. This firmware upgrade isn’t free,
contrariwise to the regular update which is free.
2 How to prepare PC
A PC or laptop with one free com port is definitively necessary. After using of laptops without any
physically com port a suitable USB to 232 adapter cable should be used. It is recommended to check
the function of such a configuration before Flarm update procedure will start. Run some other
application which requires com port, to check the com port.
Installation
3 Update procedures
3.1.1 Procedure
• Copy adequate file ( flarm_400.fw) having extension .fw to SD card, use Flarm tools
Copy to SD
Note!
Power lamp of Flarm external display will flash (or will become red by dual color displays) during the
procedure. As the procedure will finish a normal status of Power lamp will characterize this fact.
3.2.1.1 Using of Colibri power and data adapter (Ord. nr. COL AC-PC)
Every Colibri and LX 20/2000 is equipped with this kind of cable set, so there are many thousands
available by Colibri and LX 20 users. The adapter can be ordered by LX Navigation after using of our
e-shop.
Important!
Using of above mentioned cable set will also power Red Box from AC network. This configuration is
therefore extremely comfortable for indoor operation.
This cable set may be also used for update of Red Box units built into the glider. In that case remains
AC plug unplugged.
Display
Important!
Plug 6P telephone type connector into Display marked connector of Red Box.
3.2.1.2 LX Flarm update cable (Ord. nr. LX7-F-UD-cable)
This cable ensures data exchange Red Box - PC during the update procedure. This cable doesn’t
include power lines and therefore don’t power Red Box. This configuration is suitable for field
operation where Red Box receives power from the glider battery.
9P sub D female
1 blue
Note!
Optional 12 V and GND may be extended, wires 1 (blue) and 6 for indoor operation.
3.2.2 Procedure Nr.1 (recommended)
Note!
If Flarm will not connect, close Flarm Tool and try again.
• The update procedure will start automatically, after successful connection
• Follow wizard on PC and wait until Finish
Note!
If Flarm will not connect, close Flarm Tool and try again.
It is necessary to disconnect Flarm external display and to plug 6P telephone type connector of the
Flarm update cable into FLARM marked socket of LX 7007.
If FLARM marked connector isn’t easy to reach, use a RJ11 female to female interface which is
available in nearly every telephone shop. This will make possible to connect the update cable close to
the Flarm External display and this position is normally easy to reach.
LX 7007
PC
3.5.1 Procedure Nr.1
• Switch LX 7007 ON and wait until booting will finish
• Run Flarm tool (a free com port will be selected automatically)
Note!
If Flarm will not connect, close Flarm Tool and try again.
• The update procedure will start automatically immediately after connection
• Follow wizard on PC and wait until Finish
• Follow Wizard
• The update will run automatically
• After a PC message “ The device has successfully been updated” , click on Finish
• Press Enter on LX 7007
• Switch LX 7007 off and after ON
• Reconnect Flarm external display and provide functional test
• Check Flarm settings