Lug Reducer ILSCO
Lug Reducer ILSCO
Tool Manufacturers
Burndy Greenlee T&B Harger Anderson Ridgid
Y644 Series, 1990,
PAT644 Series, EK06FT, TBM8‐ RE‐6
Cover** Copper Y35 Series, Y39 Series, Y81 Series, HK12ID, HK06FT, EK1240, HK1240, 750 VC6 with
Furnished Code Wire Y46 Series (with Die Adapter), PAT81 Series EK12ID RK06FT RK1240, Series Series 4P‐6 4 PIN
With Size Copper Y750 Series, PAT750 Series Dieless Dieless Dieless EK1550, RK1550 Dieless 13100A, TBM14 Series MCT81/0 Dieless Dieless RE 12‐M
Catalog No. Adapter (Class B/C) Copper Flex Wire Size Pin Size ILSCO Die Burndy Die T&B Die
(Code/Flex) Code Wire Flex Wire # Crimps # Crimps # Crimps # Crimps ILSCO Die # Crimps # Crimps Code Wire Flex Wire # Crimps Index # # Crimps # Crimps # Crimps ILSCO Die # Crimps
F2C‐4‐4* PCC‐2 3 AWG #4 G, H, I, K, M, DLO #4 ILD‐29 U3CRT U4CRT 1 1 1 1 ILD‐29 1 1 15527‐CK 15522 1 Gray 2 1 1 ILD‐29 1
F2C‐2‐2* PCC‐3 1 AWG #2 G, H, I, K, M, DLO #2 ILD‐37 U1CRT‐1 U2CRT 1 1 1 1 ILD‐37 1 1 15513‐CK 15513‐CK 1 Green 2 1 1 ILD‐37 1
F2C‐1‐1* PCC‐4 1/0 AWG #1 G, H, I, K, M, DLO #1 ILD‐42 U25RT U1CRT‐1 1 1 1 1 ILD‐42 1 1 15508 15508 1 Pink 2 1 1 ILD‐42 1
F2C‐1/0‐1/0*
PCC‐5 2/0 AWG 1/0 G, H, I, K, M, DLO 1/0 ILD‐45 U26RT U25RT 1 1 1 1 ILD‐45 1 1 15526 15526 1 N/A N/A 1 1 ILD‐45 1
F2CO‐1/0‐1/0*
F2C‐2/0‐2/0*
PCC‐5 3/0 AWG 2/0 G, H, I, K, M, DLO 2/0 ILD‐50 U27RT U26RT 1 1 1 1 ILD‐50 1 1 15530 15530 1 N/A N/A 1 1 ILD‐50 1
F2CO‐2/0‐2/0*
F2C‐3/0‐3/0*
PCC‐6 4/0 AWG 3/0 G, H, I, K, M, DLO 3/0 ILD‐54 U28RT U27RT 1 1 1 1 ILD‐54 1 1 15511 15511 1 N/A N/A 1 1 ILD‐54 1
F2CO‐3/0‐3/0*
F2C‐4/0‐4/0*
PCC‐7 250 kcmil 4/0 G, H, I, K, M, DLO 4/0 ILD‐62 U29RT U28RT 1 1 1 1 ILD‐62 1 1 15510‐CK 15510‐CK 1 N/A N/A 1 1 ILD‐62 1
F2CO‐4/0‐4/0*
F2C‐250‐250*
PCC‐7 300 kcmil 250 G, H 250 ILD‐66 U30RT U29RT 1 1 1 1 ILD‐66 1 1 15534 15534 1 N/A N/A 1 1 ILD‐66 1
F2CO‐250‐250*
F2C‐262‐250*
PCC‐8 350 kcmil 250 I, K, M, 262 DLO 250 ILD‐71 U31RT U30RT 1 1 1 1 ILD‐71 1 1 15514‐CK 15534 1 N/A N/A 1 1 ILD‐71 1
F2CO‐262‐250*
F2C‐313‐350*
PCC‐9 400 kcmil 300 G,H,I,K,M, 313 DLO 350 ILD‐76 U32RT U31RT 1 1 1 1 ILD‐76 1 1 15512 15514‐CK 1 N/A N/A 1 1 ILD‐76 1
F2CO‐313‐350*
F2C‐373‐350*
PCC‐9 500 kcmil 350 G,H,I,K,M, 373 DLO 350 ILD‐87 U34RT U32RT 1 1 1 1 ILD‐87 1 1 15506 15512†† 1 N/A N/A 1 1 ILD‐87 1
F2CO‐373‐350*
F2C‐444‐500
PCC‐10 600 kcmil 400 G,H,I,K,M, 444 DLO 500 ILD‐94 U36RT U34RT 1 1 1 1 ILD‐94 1 1 15536‐CK 15536‐CK 1 N/A N/A 1 1 ILD‐94 1
F2CO‐444‐500
F2C‐535‐500
PCC‐11 700 kcmil 500 G,H,I,K,M, 535 DLO 500 ILD‐99 U38RT U38XRT 1 1 1 1 ILD‐99 1 1 15505 15505 1 N/A N/A 1 1 ILD‐99 1
F2CO‐535‐500
F2C‐646‐600
PCC‐12 750 kcmil 600 G,H,I,M, 646 DLO 600 ILD‐106 U39RT U39RT 1 1 1 1 ILD‐106 1 1 15515‐CK 15515‐CK 1 N/A N/A 1 1 ILD‐106 1
F2CO‐646‐600
F2C‐777‐750
PCC‐12 1000 kcmil 750 G,H,I, 777 DLO 750 ILD‐125 U44XRT† U44XRT 1 1 1 1 ILD‐125 1 1 15504 15504 1 N/A N/A N/A N/A ILD‐125 1
F2CO‐777‐750
*UL complimentary listed and certified for Canada as Wire Adapter and Grounding and Bonding Equipment, suitable for direct burial.
**Insulating cover is intended to be assembled to the wire adapter after crimp application. Do NOT crimp over the insulating cover.
***ILSCO MT‐25 crimp tool is rated to crimp copper wire (class B/C) only.
†Use Burndy die number P44RT when Burndy Y46 series crimp tool is used to crimp F2C/F2CO‐777‐750 with 1000 kcmil code copper wire.
†† Use T&B die number 15517 when T&B 13100A or TBM14 Series crimp tool is used to crimp F2C/F2CO‐373‐350 with 373 DLO wire.
FORM 263
Page 1 of 2 Revised 6‐28‐2020
INFORMATION SHEET (F2C, F2CO Series Wire Adapters)
FOR USE WITH CODE OR FLEX COPPER WIRES
NOT FOR USE WITH ALUMINUM WIRE LISTED
941R
RANGE TAKING
Tool Manufacturers Installation of Wire to F2C, F2CO Series Wire Adapter
ILSCO UTILCO Ridgid Burndy Greenlee
Standard TM‐6DF1000, IDT‐6, IDT‐12, UM‐4PT, Y644 Series, 1990, 1. Select proper wire adapter for the wire size and wire class to be used. F2C, F2CO series
Cover** Copper TR‐6DF1000, IDT‐6H, IDTB‐12, UR‐4PT, RE‐6 PAT644 Series, EK06FT, adapters are for use with copper wires only.
Furnished Code Wire Expanded Copper Code TB‐6DF1000 IDTB‐6 IDT‐12H, BLL‐4PT with Y81 Series, HK06FT, 2. Strip the wire insulation. Strip Length = Barrel Length + 1/4 Inch. Do not nick or ring the
With Size Wire Range Copper Series Series IDT‐12‐N IVTB‐6 Series 4P‐6 4 PIN PAT81 Series RK06FT wire. Remove any mylar coating on wire.
Catalog No. Adapter (Class B/C) (Class B/C) Pin Size Dieless Dieless Dieless Dieless Dieless Dieless Dieless Dieless 3. Remove surface oxide from the wire by cleaning it with wire brush.
# Crimps # Crimps # Crimps # Crimps # Crimps # Crimps # Crimps # Crimps 4. Insert wire all the way into the barrel of the adapter.
F2C‐4‐4* PCC‐2 3 AWG 3 ‐ 6 AWG #4 1 1 1 1 1 1 1 1 5. Refer to charts on both sids of this information sheet. Select the proper approved tool/die.
F2C‐2‐2* PCC‐3 1 AWG 1 ‐ 6 AWG #2 1 1 1 1 1 1 1 1 Crimp at the bottom of barrel, between crimp lines, as indicated in photos below.
F2C‐1‐1* PCC‐4 1/0 AWG 1/0 ‐ 6 AWG #1 1 1 1 1 1 1 1 1
F2C‐1/0‐1/0*
PCC‐5 2/0 AWG 2/0 ‐ 4 AWG 1/0 1 1 1 1 1 1 1 1
F2CO‐1/0‐1/0*
F2C‐2/0‐2/0*
PCC‐5 3/0 AWG 3/0 ‐ 2 AWG 2/0 1 1 1 1 1 1 1 1
F2CO‐2/0‐2/0*
F2C‐3/0‐3/0*
PCC‐6 4/0 AWG 4/0 ‐ 1 AWG 3/0 1 1 1 1 1 1 1 1
F2CO‐3/0‐3/0*
F2C‐4/0‐4/0*
PCC‐7 250 kcmil 250 kcmil ‐ 1/0 AWG 4/0 1 1 1 1 1 1 1 1
*F2CO‐4/0‐4/0
F2C‐250‐250*
PCC‐7 300 kcmil 300 kcmil ‐ 2/0 AWG 250 1 1 1 1 1 1 1 1
F2CO‐250‐250*
F2C‐262‐250*
PCC‐8 350 kcmil 350 kcmil ‐ 3/0 AWG 250 1 1 1 1 1 1 1 1
F2CO‐262‐250*
F2C‐313‐350*
PCC‐9 400 kcmil 400 kcmil ‐ 4/0 AWG 350 1 1 1 1 1 1 1 1
F2CO‐313‐350*
F2C‐373‐350*
PCC‐9 500 kcmil 500 kcmil ‐ 250 kcmil 350 1 1 1 1 1 1 1 1
F2CO‐373‐350* Key to Crimp Examples:
F2C‐444‐500 1) Acceptable Crimp ‐ Crimp is within the crimp
PCC‐10 600 kcmil 600 kcmil ‐ 250 kcmil 500 1 1 1 1 1 1 1 1
F2CO‐444‐500 zone
F2C‐535‐500 2) Acceptable Crimp ‐ If die plow width exceeds
PCC‐11 700 kcmil 700 kcmil ‐ 350 kcmil 500 1 1 1 1 1 1 1 1
F2CO‐535‐500 the crimp zone, start crimp at bottom of crimp
F2C‐646‐600 zone. Do not allow crimp to extend over bottom
PCC‐12 750 kcmil 750 kcmil ‐ 500 kcmil 600 1 1 1 1 1 1 1 1
F2CO‐646‐600 line of crimp zone
F2C‐777‐750 3) Unacceptable Crimp ‐ Crimp is not within crimp
PCC‐12 1000 kcmil 1000 kcmil ‐ 750 kcmil 750 1 1 1 N/A 1 N/A 1 1
F2CO‐777‐750 zone
*UL complimentary listed and certified for Canada as Wire Adapter and Grounding and Bonding Equipment, suitable for direct burial. 4) Unacceptable Crimp ‐ Crimp extends beyond
**Insulating cover is intended to be assembled to the wire adapter after crimp application. Do NOT crimp over the insulating cover. bottom line of crimp zone
FORM 263