0% found this document useful (0 votes)
131 views4 pages

101401-7590 - Isuzu Şampi̇yon

Uploaded by

Baytolga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
131 views4 pages

101401-7590 - Isuzu Şampi̇yon

Uploaded by

Baytolga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

101401-7590 ZEXEL test values diesel fuel-injection equipment 16.12.

10 13:45:37 Page 1

ZEXEL Ass'y No. 101401-7590


Bosch Ass'y No. 9 400 613 247
Bosch Typecode
Engine Type 4HF1
Manufacturer ISUZU
Edition date 01.03.06 (1)

1 Adjustment conditions
CAT Designation Unit Set value min. max. Actual values OT
Test oil ISO4113 or {SAEJ96
7d}
1404 Test oil
P Test oil temperature degC 40 40 45
Nozzle and nozzle holder 105780-8140
Bosch type code EF8511/9A
Nozzle 105780-0000
Bosch type code DN12SD12T
Nozzle holder 105780-2080
Bosch type code EF8511/9
P Opening pressure MPa 17.2
P Opening pressure kgf/cm2 175
Injection pipe mm 6-2-600
Outer diameter - inner diameter - length (mm)
Overflow valve 131424-4920
P Overflow valve opening pressure kPa 127 107 147
P Overflow valve opening pressure kgf/cm2 1.3 1.1 1.5
P Tester oil delivery pressure kPa 157 157 157
P Tester oil delivery pressure kgf/cm2 1.6 1.6 1.6
Direction of rotation (viewed from drive side) L
Left

2 Adjustment specification
2.1 Injection timing adjustment
CAT Designation Unit Set value min. max. Actual values OT
P Direction of rotation (viewed from drive side) L
Left
P Injection order 1-3-4-2
S Pre-stroke mm 4.1 4.05 4.15
S Rack position R=A
Point A
P Beginning of injection position NO.1
Governor side
S Difference between angles 1 deg. 90 89.5 90.5
Cal 1-3
S Difference between angles 2 deg. 180 179.5 180.5
Cal 1-4
S Difference between angles 3 deg. 270 269.5 270.5
Cyl.1-2
2.2 Injection quantity adjustment
CAT Designation Unit Set value min. max. Actual values OT
P Adjusting point -
P Rack position 12
P Pump speed r/min 960 960 960
S Average injection quantity mm3/st. 57 55.4 58.6
S Max. variation between cylinders % 0 -4 4
P Basic *
P Fixing the rack *
P Standard for adjustment of the maximum vari *
ation between cylinders
CAT Designation Unit Set value min. max. Actual values OT
P Adjusting point H
P Rack position 9.8+-0.5
P Pump speed r/min 285 285 285
S Average injection quantity mm3/st. 15.5 14.2 16.8
S Max. variation between cylinders % 0 -10 10
P Fixing the rack *
P Standard for adjustment of the maximum vari *
ation between cylinders
CAT Designation Unit Set value min. max. Actual values OT
P Adjusting point A
P Rack position R1(12)
P Pump speed r/min 960 960 960
S Average injection quantity mm3/st. 57 56 58
P Basic *
S = Setting value, C = Check value)
OT = Outside Tolerance (X is set)
101401-7590 ZEXEL test values diesel fuel-injection equipment 16.12.10 13:45:37 Page 2

P Fixing the lever *


CAT Designation Unit Set value min. max. Actual values OT
P Adjusting point B
P Rack position R1+0.1
P Pump speed r/min 1600 1600 1600
S Average injection quantity mm3/st. 68.5 64.5 72.5
P Fixing the lever *
CAT Designation Unit Set value min. max. Actual values OT
P Adjusting point C
P Rack position R1-0.2
P Pump speed r/min 500 500 500
S Average injection quantity mm3/st. 45.1 41.1 49.1
P Fixing the lever *
2.3 Governor adjustment
Name

T1=L48 N:Pump speed


R:Rack position (mm)
(1)Torque cam stamping: T1
(2)Tolerance for racks not indicated: +-0.05mm.
2.4 Timer adjustment
CAT Designation Unit Set value min. max. Actual values OT
S Pump speed r/min 1050--
P Advance angle deg. 0 0 0
Remarks
Start
CAT Designation Unit Set value min. max. Actual values OT

S = Setting value, C = Check value)


OT = Outside Tolerance (X is set)
101401-7590 ZEXEL test values diesel fuel-injection equipment 16.12.10 13:45:37 Page 3

P Pump speed r/min 1000


S Advance angle deg. 0.5 0.5
CAT Designation Unit Set value min. max. Actual values OT
P Pump speed r/min 1600
S Advance angle deg. 5 4.5 5.5
Remarks
Finish
2.5 Speed control lever angle
Name
a=41deg+-5deg
b=35.5deg+-3deg

F:Full speed
I:Idle
(1)Stopper bolt set position 'H'
2.6 Stop lever angle
Name
a=23deg+-5deg
b=(29deg)+-5deg

aa=58mm N:Pump normal


bb=1600r/min S:Stop the pump.
cc=5+-0.2mm (1)Use the hole at R = aa
(2)At pump speed bb and rack position cc, set the stopper bolt.

S = Setting value, C = Check value)


OT = Outside Tolerance (X is set)
101401-7590 ZEXEL test values diesel fuel-injection equipment 16.12.10 13:45:37 Page 4

2.7 Timing setting


Name
a=(60deg)
b=(85deg)

aa=8deg (1)Pump vertical direction


(2)Position of gear's standard threaded hole at No 1 cylinder's beginning of injection
(3)Stamping position on the A/T outer rim
(4)Pump bracket check hole position.
(5)At the No 1 cylinder's beginning of injection, align with the projection seen through the bracket'
s check hole and mark the A/T's bevel C1.
(6)B.T.D.C.: aa

S = Setting value, C = Check value)


OT = Outside Tolerance (X is set)

You might also like