Utilities Assignmentp2
Utilities Assignmentp2
Ref
BEDROOM 2 T&B
ACU
C6
Oven
C5
f SYMBOLS: ELECTRICAL GENERAL NOTES:
C7
e g
1. ALL ELECTRICAL INSTALLATIONS HEREIN AND OTHER RELATED WORKS TO BE DONE IN
Water CEILING LIGHT THIS BUILDING SHALL BE IN ACCORDANCE WITH THE PROVISIONS AND STANDARDS OF
C8
Sf pump
THE FOLLOWING:
CONVENIENCE OUTLET 1.1 THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE.
1.2 REPUBLIC ACT 7926 OTHERWISE KNOWN AS THE NEW ELECTRICAL
ENGINEERING LAW
Se KITCHEN SPECIAL PURPOSE OUTLET
1.3 THE NATIONAL BUILDING CODE OF THE PHILIPPINES.
1.4 FIRE CODE OF THE PHILIPPINES.
SPECIAL PURPOSE OUTLET 1.5 EXISTING RULES AND REGULATION OF THE LOCAL POWER UTILITY COMPANY.
h (ACU) 1.6 THE EXISTING CITY/MUNICIPAL ORDINANCES AND,
1.7 THE BUREAU OF LABOR STANDARDS.
Sgh M WATT HOUR-METER 2. ALL ELECTRICAL INSTALLATIONS HEREIN SHALL BE DONE UNDER THE DIRECT
SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER. HE SHALL BE RESPONSIBLE
IN THE INTERPRETATION OF THE PLANS AND SPECIFICATION AND THE REQUIRED
PB
PANEL BOARD - PB STANDARDS OF THE ELECTRICAL CODE.
3. MATERIALS AND EQUIPMENT TO BE USED SHALL HAVE INSPECTED COMMODITY
CLEARANCE (ICC) LABEL FOR FOREIGN MADE PRODUCTS AND P.S. MARK FOR LOCAL IN
CIRCUIT BRANCH NATURE OF THE BUREAU OF PRODUCT STANDARD (BPS).
d Scd Si 4. PROVIDE GROUNDING WIRE TO ALL OUTLETS AND LIGHTING CIRCUITS, ALL NON CURRENT
CIRCUIT CARRYING METAL PARTS SHALL BE GROUNDED AND BOBDED INCLUDING FENCE AND
HOMERUN GATE.
BEDROOM 1 5. ALL PANEL BOARDS, MAIN DISTRIBUTION PANELS, ETC., SHALL HAVE GROUNDING BUS FOR
14500
KILOWATTHOUR
BRANCH CIRCUITS AND SUB FEEDER GROUNDING SYSTEM SHALL BE BONDED TO THE
DINING i METER
NEAREST METAL WATER PIPE.
GROUND 6. MOUNTING HEIGHT FOR ALL WIRING DEVICES AND PANEL BOARDS SHALL BE.
LUGS 6.1 LIGHTING OUTLETS 1.40M ABOVE FLOOR FINISH.
ACU
6.2 CONVENIENCE OUTLETS 0.30M ABOVE FLOOR FINISH.
C4 LIGHTING CIRCUIT LINE 6.3 TELEPHONE OUTLETS 0.30M ABOVE FLOOR FINISH.
c
6.4 PANEL BOARDS & CABINETS 1.40M ABOVE FLOOR FINISH.
POWER CIRCUIT LINE 7. WIRING METHODS SHALL BE AS FOLLOWS:
7.1 SERVICE ENTRANCE RESISTS INTERMEDIATE METALLIC
Sa 1 Gang Switch
CONDUIT (IMC).
Sab 2 Gang Switch 7.2 LIGHTING AND POWER SYSTEM POLYVINYL CHLORIDE (PVC).
7.3 TELEPHONE OUTLETS POLYVINYL CHLORIDE (PVC).
Sabc 3 Gang Switch 7.4 ALL VIBRATING EQUIPMENTS LIQUID TIGHT FLEXIBLE METAL
CONDUIT.
8. NO CHANGES OR MODIFICATION SHALL BE MADE WITHOUT THE DESIGNERS WRITTEN
C2
CONSENT.
9. ALL WORKS SHALL BE EXECUTED IN A WORKMANSHIP MANNER AND SHALL PREVENT A
NEAT AND ORDERLY ACCEPTANCE. ALL WIRING SHALL BE CONCEALED IN THE LEAST
PB
C1 b POSSIBLE WAY.
a
LIVING AREA
C3
ACU
Sab
DRAWN BY: APPROVED BY: PROJECT TITLE: COURSE: SCHOOL: SHEET NO.
HOLY NAME UNIVERSITY
MICHELLE L. GALEDO ENGR. TEOFILO BAJAO PROPOSED 1 STOREY BUILDING UTILITIES 1 E-1
INSTRUCTOR SHEET CONTENTS
DATE PREPARED: OCTOBER 5, 2024 ELECTRICAL WIRING LAYOUT, SYMBOLS, & NOTES