Self-Test Series Self-Testing Addressable Detectors

The breakthrough NOTIFIER® Self-Test Series intelligent plug-in


smoke detectors are designed for performance, ease of use and
aesthetics. When used with NOTIFIER INSPIRE™ Series N16
panel, the Self-Test Series detectors automatically perform mainte-
nance tests of smoke and heat detection without using canned
smoke or heat guns. The Self-Test process meets the three core
NFPA requirements for detector maintenance: functional test, smoke
entry test, and ability to verify a visual inspection has taken place. It
is the first detector of its type to be approved by UL. It also retains
the great features of the standard 951 series including the enhanced
optical sensing chamber which is engineered to sense smoke pro-
duced by a wide range of combustion sources in accordance with
more stringent code standards. For ease, its sensitivity can also be
programmed in the control panel software. Sensitivity is continuously
monitored and reported to the panel. Point ID capability allows each
detector’s address to be set with rotary, decimal address switches,
providing exact detector location for selective maintenance when
chamber contamination reaches an unacceptable level. Dual elec-
tronic thermistors add 135°F (57°C) fixed temperature thermal sens-
ing on the FSP-951T-SELFT. The NOTIFIER Self-Test series
detectors are available for our FlashScan® applications. MECHANICALS
• Sealed against back pressure
Features • SEMS screws for wiring of the separate base
SELF-TEST • Designed for direct-surface or electrical-box mounting
• Introduces small amounts of smoke and heat into the chamber to • Plugs into separate base for ease of installation and maintenance
test both sensors
OPTIONS
• Automatically tests if the photo sensor smoke entry points are
blocked by the dust cover • Optional relay, isolator, and sounder bases
• Verifies that the technician has completed the visual inspection Installation
through its built-in beacon and the self test app
NOTIFIER Self-Test Series plug-in intelligent smoke detectors use a
• Tests detectors across multiple loops and panels concurrently
detachable base to simplify installation, service and maintenance.
• Listed to UL 268 7th edition and/or UL 521 Installation instructions are shipped with each detector.
SLC LOOP Mount detector base (all base types) on an electrical backbox which
• Two-wire SLC loop connection is at least 1.5" (3.81 cm) deep. For a chart of compatible junction
boxes, see DN-60054.
• Unit uses base for wiring
• Compatible with FlashScan® protocol systems NOTE: Because of the inherent supervision provided by the SLC loop,
end-of-line resistors are not required. Wiring “T-taps” or branches are
• Stable communication technique with noise immunity permitted for Class “B” wiring only.
When using relay or sounder bases, consult the ISO-X/ISO-XA manuals
ADDRESSING for device limitations between isolator modules and isolator bases.
• Addressable by device
• Rotary, decimal addressing Construction
(Refer to the NOTIFIER panel manuals for device capacity.) These detectors are constructed of fire-resistant plastic.
ARCHITECTURE NOTIFIER® Self-Test Series plug-in intelligent smoke detectors are
designed to commercial standards and offer an attractive appear-
• Sleek, low-profile, stylish design ance.
• Unique single-source design to respond quickly and dependably
to a broad range of fires Operation
• Integral communications and built-in device-type identification Each NOTIFIER Self-Test Series detector uses one of the panel’s
• Tamper resistance option provided by bases addresses on the NOTIFIER Signaling Line Circuit (SLC). The
• Remote test feature from the panel detector responds to regular polls from the control panel and reports
its type and the status. If it receives a test command from the panel
• Built-in functional test switch activated by external magnet
(or a local magnet test), it stimulates its electronics and reports an
• Removable cover and insect-resistant screen for simple field alarm. It blinks its LEDs when polled and turns the LEDs on when
cleaning commanded by the panel. The NOTIFIER Self-Test Series offers an
OPERATION industry breakthrough with its UL approved Self-Test feature as well
as great fire detection performance that represent the latest in
• LED “blinks” when the unit is polled (communicating with the fire smoke detector technology.
panel) and latches in alarm.
• Low standby current

DN-62046:A • 2/19/2021 — Page 1 of 3


Product Line Information MOUNTING KITS AND ACCESSORIES
FSP-951-SELFT: White, low-profile intelligent self-testing photo- TR300: White, replacement flange for B300-6 series bases
electric sensor, FlashScan only TR300-IV: Ivory, replacement flange for B300-6 series bases
FSP-951T-SELFT: White, same as FSP-951 but includes a built-in RA100Z: Remote LED annunciator. 3-32 VDC. Mounts to a U.S. sin-
135°F (57°C) fixed-temperature thermal device, FlashScan only gle-gang electrical box. For use with B501 and B300-6 series bases.
FST-951-SELFT: White, low-profile intelligent self-testing 135°F M02-04-00: Test magnet
fixed thermal sensor, FlashScan only M02-09-00: Test magnet with telescoping handle
INTELLIGENT BASES CK300: Color Kit (includes cover and trim ring), white, 10-pack, for
NOTE: For details on intelligent bases, see DN-60054. use with FST-951-SELFT only
B300-6: White, 6” base, standard flanged low-profile mounting base CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack, for
(CSFM: 7300-1653:0109) use with FST-951-SELFT only
B300-6-IV: Ivory,6” base, standard flanged low-profile mounting CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack,
base (CSFM: 7300-1653:0109) for use with FST-951-SELFT only
B300-6-BP: Bulk pack of B300-6, package contains 10
B501-WHITE: White, 4” standard European flangeless mounting
base. UL listed (CSFM: 7300-1653:0109)
B501-BL: Black, 4” standard European flangeless mounting base.
UL listed (CSFM: 7300-1653:0109)
B501-IV: Ivory, 4” standard European flangeless mounting base. UL
listed (CSFM: 7300-1653:0109)
B501-WHITE-BP: Bulk pack of B501-WHITE contains 10
B224RB-WH: White, relay base (CSFM: 7300-1653:0216)
B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216)
B224BI-WH: White, isolator detector base (CSFM: 7300-1653:0216)
B224BI-IV: Ivory isolator detector base (CSFM: 7300-1653:0216)
B200S-WH: White, Intelligent addressable sounder base capable of
producing sound output in high or low volume with ANSI Temporal 3,
ANSI Temporal 4, continuous tone, marching tone, and custom tone.
Uses FlashScan protocol. (CSFM: 7300-1653:0213)
B200S-IV: Ivory, Intelligent addressable sounder base capable of
producing sound output in high or low volume with ANSI Temporal 3,
ANSI Temporal 4, continuous tone, marching tone, and custom tone.
Uses FlashScan protocol. (CSFM: 7300-1653:0213)
B200S-LF-WH: White, Low Frequency Intelligent, programmable
sounder base. Produces a fundamental frequency of 520 Hz +/-10%
with a square wave or its equivalent; designed to meet the NFPA 72
sleeping space requirement. (CSFM: 7300-1653:0238)
B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable
sounder base. Produces a fundamental frequency of 520 Hz +/-
10% with a square wave or its equivalent; designed to meet the
NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238)
B200SR-WH: White, Intelligent sounder base capable of producing
sound output with ANSI Temporal 3 or continuous tone. Intended for
retrofit applications. (CSFM: 7300-1653:0213)
B200SR-IV: Ivory, Intelligent sounder base capable of producing
sound output with ANSI Temporal 3 or continuous tone. Intended for
retrofit applications. (CSFM: 7300-1653:0213)
B200SR-LF-WH: White, Low Frequency Intelligent, programmable
sounder base. Produces a fundamental frequency of 520 Hz +/-
10% with a square wave or its equivalent; designed to meet the
NFPA 72 sleeping space requirement. Intended for retrofit applica-
tions. (CSFM: 7300-1653:0238)
B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable
sounder base. Produces a fundamental frequency of 520 Hz +/-
10% with a square wave or its equivalent; designed to meet the
NFPA 72 sleeping space requirement. Intended for retrofit applica-
tions. (CSFM: 7300-1653:0238)

Page 2 of 3 — DN-62046:A • 2/19/2021


SPECIFICATIONS

ELECTRICAL SPECIFICATIONS STANDARDS


Voltage range: 15 - 32 volts DC peak • UL268 7th edition (FSP-951-SELFT, FSP-951T-SELFT)
Standby current (max. avg.): 200µA @ 24 VDC (one communica- • UL521 (FSP-951T-SELFT, FST-951-SELFT)
tion every 5 seconds with LED enabled)
Listings and Approvals
Max current: 4.5 mA @ 24 VDC (“ON”)
Listings and approvals below apply to the Self-Test Series detectors.
PHYSICAL SPECIFICATIONS In some cases, certain modules may not be listed by certain
Sensitivity: approval agencies, or listing may be in process. Consult factory for
latest listing status.
• UL Applications:
– Open Area: 2.86 - 5.0 %/FT obscuration • UL Listed: S1115
– Special Application: 0.5 - 2.86 %/FT obscuration • CSFM: 7270-0028:0502 (FST-951-SELFT), 7272-0028:0503
(FSP-951-SELFT, FSP-951T-SELFT)
Size: 2.0" (51mm) high; base determines diameter
– B300-6 series: 6.1" (15.6 cm) diameter
– B501 series: 4" (10.2 cm) diameter
For a complete list of detector bases see DN-60054
Shipping weight: 3.4 oz. (95 g)
Operating temperature range:
• FSP-951-SELFT: 32°F to 122°F (0°C to 50°C)
• FSP-951T-SELFT: 32°F to 115°F(0°C to 47°C)
• FST-951-SELFT:
– Set for fixed-temperature or rate-of-rise (ROR):–4°F to 100°F
(–20°C to 38°C)
– Set for high-heat: –4°F to 150°F (–20°C to 66°C)
UL Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.). Velocity
range with Self-Test process in operation: 0-300 ft/min (91.4 m/min).
Relative humidity: 10% – 93% non-condensing
Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of-
rise detection 15°F (8.3°C) per minute, high temperature heat 190°F
(88°C)
Self-Test Operation: The Self-Test feature offers up to 150 tests
before reaching an end of life.
Mounting: To ensure the operation of the Self-Test feature, a detec-
tor installed on the ceiling must remain in a ceiling-oriented position;
those installed on the wall must remain in a wall-oriented position.
Detector Spacing and Applications: NOTIFIER recommends
spacing detectors in compliance with NFPA 72. For specific informa-
tion regarding detector spacing, placement, and special applications
refer to NFPA 72. A System Smoke Detector Application Guide, doc-
ument SPAG91, is available at www.systemsensor.com.

This document is not intended to be used for installation purposes.


We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.

NOTIFIER INSPIRE™ is a trademark of and FlashScan®, NOTIFIER®,


NOTIFIER and System Sensor® are registered trademarks of Honeywell
12 Clintonville Road International, Inc.
Northford, CT 06472 ©2021 by Honeywell International Inc. All rights reserved. Unauthorized
203.484.7161 use of this document is strictly prohibited.

www.notifier.com Country of Origin: Mexico