EDISON REAL ESTATE LIMITED

246, Rangs Babylonia, Tejgaon Link Road, Dhaka- 1208

Department of QA & QC- PMO

Checked Area: Basement-2 Roof Slab and basement-1 mat foundation Rebar
Project Name: Edison Orlando
Fabrication

Project & QC Inspection


Project In Charge:
Inspection
Shaleh Mahmud Shakkwar & Swapnil Das
Summary Attendee(s):
Contractor: ECL

Inspection Date: 19.11.2024 Casting Date: 19.11.2024 Variance From Master Schedule: -

Checklist -
Rebar Fabrication, Rebar Nos, Rebar Diameter, Rebar Spacing,
Project Safety ✔ Inspection Item(s):
Clear Cover, Slab Level, Casting Level, Cleanliness & Safety.
Rectification ✔

Findings Overview
Responsib
Severity le
S/N Description of Findings Root Cause Action Item(s) Remarks
Score Departme
nt
Beam & slab rebar Nos, spacing,
1 diameter & lapping were checked N/A x N/A x
& found okay.

Clear cover was not maintained in


2 N/A x N/A
several places.

Randomly slab level was checked


3 N/A x N/A
& found okay.

Ramp rebar fabrication and Slope


4 N/A x N/A
is ok.

Rebar Alignment is slightly twisted Supervision


5 4 Construction Rectified
at sw-8 Workmanship

Electrical conduit pipes were go


Supervision
6 through Column. Which Must be re- 5 Construction Rectified
position

Some Holes Observed in Ramp


7 4 Supervision Construction Rectified
slope shutter.

Rebar is placed in Column by


Supervision
8 drilled hole without apply Exopy for 6 Construction Rectified
Workmanship
proper bonding

Some Rubish Found in C-2 Column. Cleaned in precense of QC


9 5 Supervision Construction
Proper Cleaning Required. Engineer

Recommendation(s)
1 It is recommended to go forward for casting after rectification & send feedback to QC.

2 Ensure proper curing after casting.

Pictorial Description(s)

Drilled hole without apply Exopy Electrical conduit pipes were go through Column.

Rebar Alignment is slightly twisted at sw-8


Some Rubish Found in C-2 Column.

QC Notes