Wind Load Calculation, ASCE

Project : AA Job No : 1
Client : BB Date : 19/08/2021
Address : CC Rev No. : 2.00
Calc By : Md. Ali Shamsur Rahman ASR ID 1
Chk'd By : Arif Mohammed Bin Golam Kader AMGK Code : ASCE

Define Building North Along Y Load Case All Case


Framing System Main Wind Force Resisting System Parapet 0 Unit US
Location mile/hr Manual 135 Mile/hr Code ASCE
Risk Category of building II I = 1.00
Exposure category A
Ridge Height, hr 25
Eave Height, he 15
Building Width, along Y 40 ft Wind

hr
B
Building Length, along X 80 ft

h
#REF!

he
Roof Type Monoslope
Enclosed? (Y/N) Yes Enclosed Y
Damping Ratio, β 0.02
X L L
Ct Concrete moment-resisting frames
Plan Elevation
Topographic factor, Kzt 1.000 1.000
Gust Factor, G 0.85 0.85
Kd 0.85 0.85
Slope in degree 14.04 14.04 Velocity Pressure: qh = 0.00256*Kz*Kzt*Kd*V^2*I (Psf) = 42.83
Normal Parallel
Velocity Pressures
Height (ft) kz kzt qz (psf)
Eave 15.00 1.03 1.000 40.85
0 - 15 ft 15.00 1.03 1.000 40.85
Mean Roof Height h 20.00 1.08 1.000 42.83
Ridge Height 25.00 1.13 1.000 44.81

External Wall Pressure Coefficient


Surface Wind Direction L/B h/L Cp
Windward Wall All All All 0.8
Parallel(II) to Slope 0.50 0.500 -0.5
Leeward wall
Normal (ꓕ) to Slope 2.00 0.25 -0.3
Side Wall All All -0.7

Roof Pressure Coefficient for Wind Parallel (II) to Ridge Roof Pressure Coefficient for Wind Normal (ꓕ) to Ridge
Surface Cp Surface Cp
Windward Roof Cp -0.74 Roof Cp Zone #1, 0 to h/2 -0.90 -0.18
Windward Roof Cp -0.18 Roof Cp Zone #2, h/2 to h -0.90 -0.18
Leeward Roof Cp -0.50 Roof Cp Zone #3, h to 2h -0.50 -0.18
N/A Roof Cp Zone #4, > 2h -0.30 -0.18

Internal Pressure Coefficients, GCpi Parapet Pressure Coefficients, GCpi


+GCpi Coef. 0.18 Cp win for Parapet -
-GCpi Coef. -0.18 Cp lee for Parapet -

Main Wind Force Resisting System (MWFRS) Net Pressure

Where q =qz for windward wall


q =qh for leeward wall, side wall and roof
qi =qh for windward walls, leeward walls, side walls and roofs of enclosed buildings
qi =qh used with -GCpi for partially enclosed buildings
qi =qz used with +GCpi for partially enclosed buildings
Wind Load Calculation, ASCE
Project : AA Job No : 1
Client : BB Date : 19/08/2021
Address : CC Rev No. : 2.00
Calc By : Md. Ali Shamsur Rahman ASR ID 1
Chk'd By : Arif Mohammed Bin Golam Kader AMGK Code : ASCE

Wind Y

MWFRS Pressure for Wind Parallel to Slope Normal to Ridge Line Eave 15ft Notes: qh = 42.83; GCpi ±0.18; qh(GCpi) = ±7.71
Design Pressure p (psf)
Surface Height (ft) qz (psf) G Cp + Gcpi - GCpi Case 1 Case 2
+ Gcpi - GCpi
Ridge Height --- --- --- --- --- --- --- ---
Windward Mean Height --- --- --- --- --- --- --- ---
wall Eave 15.00 40.85 0.85 0.8 0.18 -0.18 20.07 35.49
0 - 15 ft 15 40.85 0.85 0.8 0.18 -0.18 20.07 35.49
Leeward wall All 42.83 0.85 -0.5 0.18 -0.18 -25.91 -10.49
Side wall All 42.83 0.85 -0.7 0.18 -0.18 -33.19 -17.77
Roof
Roof (windward) cond. 1 0 - h/2 42.83 0.85 -0.74 0.18 -0.18 -34.60 -19.18
Roof (windward) cond. 2 h/2 - h 42.83 0.85 -0.18 0.18 -0.18 -14.26 1.16
Roof (leeward) h - 2h 42.83 0.85 -0.50 0.18 -0.18 -25.91 -10.49
>2h --- --- --- --- --- ---
Roof (Zone #1, 2, 3, 4 ) Cond. 2 --- --- --- --- --- --- ---
Overhang Roof Top Yes 42.83 0.85 -0.74 -26.89 -26.89
Windward Roof Bottom Yes 40.85 0.85 0.80 27.78 27.78
Overhang Roof Top Yes 42.83 0.85 -0.50 -18.20 -18.20
Leeward Roof Bottom Yes 44.81 0.85 -0.50 -19.05 -19.05

MWFRS Pressure for Wind Parallel to Slope Normal to Ridge Line Ridge 25 ft Notes: qh = 42.83; GCpi ±0.18; qh(GCpi) = ±7.71
Design Pressure p (psf)
Surface Height (ft) qz (psf) G Cp + Gcpi - GCpi Case 1 Case 2
+ Gcpi - GCpi
Ridge Height 25.00 44.81 0.85 0.8 0.18 -0.18 22.76 38.18
Windward Mean Height 20.00 42.83 0.85 0.8 0.18 -0.18 21.42 36.83
wall Eave 15.00 40.85 0.85 0.8 0.18 -0.18 20.07 35.49
0 - 15 ft 15 40.85 0.85 0.8 0.18 -0.18 20.07 35.49
Leeward wall All 42.83 0.85 -0.5 0.18 -0.18 -25.91 -10.49
Side wall All 42.83 0.85 -0.7 0.18 -0.18 -33.19 -17.77
Roof
Roof (windward) cond. 1 0 - h/2 42.83 0.85 -0.74 0.18 -0.18 -34.60 -19.18
Roof (windward) cond. 2 h/2 - h 42.83 0.85 -0.18 0.18 -0.18 -14.26 1.16
Roof (leeward) h - 2h 42.83 0.85 -0.50 0.18 -0.18 -25.91 -10.49
>2h --- --- --- --- --- ---
Roof (Zone #1, 2, 3, 4 ) Cond. 2 --- --- --- --- --- --- ---
Overhang Roof Top No '--- '--- '--- '--- '---
Windward Roof Bottom No '--- '--- '--- '--- '---
Overhang Roof Top No '--- '--- '--- '--- '---
Leeward Roof Bottom No '--- '--- '--- '--- '---

Notes: Overhang pressures are not affected by internal pressures. The Standard does not address bottom surface pressures for leeward overhang.
It could be argued that leeward wall pressure coefficients can be applied, but note that neglecting the bottom overhang pressures would be
conservative in this application.
Wind Load Calculation, ASCE
Project : AA Job No : 1
Client : BB Date : 19/08/2021
Address : CC Rev No. : 2.00
Calc By : Md. Ali Shamsur Rahman ASR ID 1
Chk'd By : Arif Mohammed Bin Golam Kader AMGK Code : ASCE

Design pressures for MWFRS for wind parallel to roof slope, normal to 15 -ft wall:
Design pressure p (psf) + Gcpi
Case 1

-25.91
Positive Internal Pressure (+GCpi)
10.95

+7.71
Wind

Elevation

40.00 ft

-33.19

ft
-25.91
10.95

Positive Internal Pressure (+GCpi)

80
Wind

-33.19

40.00 ft
Plan
Design pressure p (psf) - GCpi
Case 2
-10.49

Nagative Internal Pressure (+GCpi)


-7.71
35.49

Wind

Elevation
Wind Load Calculation, ASCE
Project : AA Job No : 1
Client : BB Date : 19/08/2021
Address : CC Rev No. : 2.00
Calc By : Md. Ali Shamsur Rahman ASR ID 1
Chk'd By : Arif Mohammed Bin Golam Kader AMGK Code : ASCE

Design pressure p (psf) - GCpi


Case 2 -17.77

ft
-10.49
35.49 Nagative Internal Pressure (+GCpi)

80
Wind

-17.77

40.00 ft
Plan

Design pressures for MWFRS for


wind parallel to roof slope,
normal to 25 -ft wall:
+ Gcpi

22.76
Case 1

21.42
Wind
Positive Internal Pressure (+GCpi)
-25.91

+7.71 20.07

Elevation

40.00 ft

-33.19
ft

-25.91

22.76

Positive Internal Pressure (+GCpi)


80

Wind

-33.19

40.00 ft
Plan
Wind Load Calculation, ASCE
Project : AA Job No : 1
Client : BB Date : 19/08/2021
Address : CC Rev No. : 2.00
Calc By : Md. Ali Shamsur Rahman ASR ID 1
Chk'd By : Arif Mohammed Bin Golam Kader AMGK Code : ASCE

Design pressure p (psf) - GCpi


Case 2

38.18
Wind

36.83
Nagative Internal Pressure (+GCpi)
-10.49

-7.71

35.49
Elevation
Design pressure p (psf) - GCpi
Case 2
-17.77
ft

-10.49

38.18
Nagative Internal Pressure (+GCpi) Wind
80

-17.77

40.00 ft
Plan
Wind X
MWFRS Pressure for Wind Normal to Slope Parallel to Ridge Line Notes: qh = 42.83; GCpi ±0.18; qh(GCpi) = ±7.71
Net Pressure p (psf)
Surface Height (ft) qz (psf) G Cp + Gcpi - GCpi Case 1 Case 2
+ Gcpi - GCpi
Ridge Height 25.00 44.81 0.85 0.8 0.18 -0.18 22.76 38.18
Windward Mean Height 20.00 42.83 0.85 0.8 0.18 -0.18 21.42 36.83
wall Eave 15.00 40.85 0.85 0.80 0.18 -0.18 20.07 35.49
All 40.85 0.85 0.8 0.18 -0.18 20.07 35.49
Leeward wall All 42.83 0.85 -0.3 0.18 -0.18 -18.63 -3.21
Side wall All 42.83 0.85 -0.7 0.18 -0.18 -33.19 -17.77
Roof
Roof (zone #1) cond. 1 0 - h/2 42.83 0.85 -0.90 0.18 -0.18 -40.47 -25.06
Roof (zone #2) cond. 1 h/2 - h 42.83 0.85 -0.90 0.18 -0.18 -40.47 -25.06
Roof (zone #3) cond. 1 h - 2h 42.83 0.85 -0.50 0.18 -0.18 -25.91 -10.49
Roof (zone #4) cond. 1 >2h 42.83 0.85 -0.30 0.18 -0.18 -18.63 -3.21
Roof (Zone #1, 2, 3, 4 ) Cond. 2 42.83 0.85 -0.90 0.18 -0.18 -40.47 -25.06
Wind Load Calculation, ASCE
Project : AA Job No : 1
Client : BB Date : 19/08/2021
Address : CC Rev No. : 2.00
Calc By : Md. Ali Shamsur Rahman ASR ID 1
Chk'd By : Arif Mohammed Bin Golam Kader AMGK Code : ASCE

Design pressures for MWFRS for wind perpendicular to roof slope, parallel to ridge line
Design pressure p (psf)
+ Gcpi -17.77
Case 1

ft
-18.63
22.76
Positive Internal Pressure (+GCpi)

40
Wind

-17.77

80.00 ft
Plan
-40.47
-25.91 -25.91

22.76

-18.63
21.42
Positive Internal Pressure (+GCpi)
Wind +7.71
20.07

Elevation

80.00 ft
Design pressure p (psf) - GCpi
Case 2
-33.19
ft
38.18

-3.21

Nagative Internal Pressure (+GCpi)


40

Wind

-33.19

80.00 ft
Plan
Wind Load Calculation, ASCE
Project : AA Job No : 1
Client : BB Date : 19/08/2021
Address : CC Rev No. : 2.00
Calc By : Md. Ali Shamsur Rahman ASR ID 1
Chk'd By : Arif Mohammed Bin Golam Kader AMGK Code : ASCE

-25.06
-10.49 -3.21

38.18

36.83

-3.21
Nagative Internal Pressure (+GCpi)
Wind -7.71
35.49

Elevation

80.00 ft