RE 29199/07.

05 1/12
Proportional pressure reducing valve,
pilot operated, with on-board elec-
tronics (OBE) and position feedback

Type DREBE10Z

Nominal size 10
Unit series 1X
Maximum working pressure A, B, X 315 bar, Y 2 bar
Maximum flow rate Qnom 120 l/min

List of contents Features


Contents Page – Pilot operated valves with position feedback and on-board
Features 1 electronics for reducing system pressure (pilot oil internal only,
with relief port X)
Ordering data 2
– Adjustable through the position of the armature against the
Preferred types, symbol 2
compression spring
Function, sectional diagram 3
– With position control, minimal hysteresis <1%, rapid
Technical data 4 to 6 response times, see Technical Data
On-board trigger electronics 7 and 8 – Pressure limitation to a safe level even with faulty electronics
Characteristic curves 9 (solenoid current I > Imax)
Unit dimensions 10 – For subplate attachment, mounting hole configuration to
ISO 5781-AG-06-2-A
Subplates as per catalog sheet RE 45055
(order separately)
– Plug-in connector to DIN 43563-AM6, see catalog sheet
RE 08008 (order separately)
– Data for the on-board trigger electronics
• Complies with CE, EMC directives EN 61000-6-2: 2002-08
and EN 61000-6-3: 2002-08
• UB = 24 Vnom DC
• Electrical connection 6P+PE
• Signal actuation
– Standard 0...+10 V (A1)
• Valve curve calibrated at the factory
2/12 Bosch Rexroth AG Hydraulics DREBE10Z RE 29199/07.05

Ordering data

DREB E 10 Z 1X XY M G24 K31 A1 M *

Proportional pressure Further information


reducing valve with in plain text
inductive position trans- M= NBR seals,
ducer on the cone suitable for mineral oils
With on-board electronics =E (HL, HLP) to DIN 51524
Nominal size = 10 Interface for trigger electronics*
Mounting hole configuration to =Z A1 = Setpoint input 0...+10 V
ISO 5781-AG-06-2-A K31 = Electrical connection
Unit series 10 to 19 = 1X without plug-in connector,
(10 to 19: installation and connection with unit plug to DIN 43563-AM6
dimensions unchanged) Order plug-in connector separately

Max. pressure stage G24 = Voltage supply of


trigger electronics
up to 180 bar = 180
24 V DC
up to 315 bar = 315
M= Without non-return valve
Relief port X
Pilot oil port Y = XY
* Variant “F1” (4...20 mA version) available on request

Preferred types

Type .......A1 (0...+10 V) Material Number


DREBE10Z–1X/180XYMG24K31A1M 0 811 402 155
DREBE10Z–1X/315XYMG24K31A1M 0 811 402 152

Symbol
For on-board electronics
D
B
E

Y X A
RE 29199/07.05 DREBE10Z Hydraulics Bosch Rexroth AG 3/12

Function, sectional diagram

General Basic principle


Type DREBE10Z proportional pressure reducing valves are To adjust the system pressure, a setpoint is set in the trigger
pilot operated and are used to reduce system pressure. electronics. Based on this setpoint, the electronics control the
They are actuated by means of a position-controlled propor- position-controlled solenoid.
tional solenoid with on-board electronics. The proportional solenoid maintains its position against
The valve body contains a logic element (spool valve) of the a spring force, which is proportionate to the system pressure.
“normally open” type. This is pilot operated and is in conical The pilot stage is supplied with pilot oil at a flow rate of
seat design. < 0.8 l/min through a bore. The “pmax” pressure stage is
determined by the cone and seating bore configuration.
Pressure limitation for maximum safety
If a fault occurs in the electronics, so that the solenoid current
(Imax) would exceed its specified level in an uncontrolled man-
ner, the pressure cannot rise above the level determined by the
maximum spring force.

EN 61000-6-2: 2002-08
EN 61000-6-3: 2002-08

Proportional solenoid
with position transducer Pilot valve

Spool valve cartridge

Alternative

Accessories
Type Material Number
(4 x) f ISO 4762-M10x80-10.9 Cheese-head bolts 2 910 151 309
* Plug-in connectors 6P+PE, KS 1 834 482 022
see also RE 08008 KS 1 834 482 026
MS 1 834 482 023
MS 1 834 482 024
KS 90° 1 834 484 252

Testing and service equipment


Test box type VT-PE-TB3, see RE 30065
Measuring adapter 6P+PE type VT-PA-2, see RE 30068
4/12 Bosch Rexroth AG Hydraulics DREBE10Z RE 29199/07.05

Technical data

General
Construction Pilot stage Poppet valve
Main stage Pressure reducing valve
Valve cartridge Spool valve, normally open
Actuation Proportional solenoid with position control and OBE
Connection type Subplate, mounting hole configuration NG10 (ISO 5781-AG-06-2-A)
Mounting position Optional
Ambient temperature range °C –20...+50
Weight kg 7.8
Vibration resistance, test condition Max. 25 g, shaken in 3 dimensions (24 h)

Hydraulic (measured with HLP 46, oil = 40 °C ±5 °C)


Pressure fluid Hydraulic oil to DIN 51524...535, other fluids after prior consultation
Viscosity range recommended mm2/s 20...100
max. permitted mm2/s 10...800
Pressure fluid temperature range °C –20...+70
Maximum permitted degree of contamina- Class 18/16/13 1)
tion of pressure fluid
Purity class to ISO 4406 (c)
Direction of flow See symbol
Max. set pressure (at Qmin = 1 l/min) bar 180 315
Minimum pressure (at Qmin = 1 l/min) bar 6 8
Max. mechanical pressure limitation bar < 190 < 325
level, e.g. when solenoid current I ⬎ Imax
Max. working pressure bar Port A, B: 315
Port Y: ⱕ 2 external pilot oil drain
Port X: 315 relief port
Internal pilot oil flow l/min ⱕ 0.8
Max. flow l/min 120 for Qmax, see Characteristic Curves

Static/Dynamic
Hysteresis % ⬉1
Manufacturing tolerance for pmax % ⬉ ±5, see Characteristic Curves
Response time 100 % signal change ms ⬇ 80 dependent on dead volume or system volume
Thermal drift < 1 % at ∆T = 40 °C
Conformity EN 61000-6-2: 2002-08
EN 61000-6-3: 2002-08
1) The purity classes stated for the components must be complied with in hydraulic systems.
Effective filtration prevents problems and also extends the service life of components.
For a selection of filters, see catalog sheets RE 50070, RE 50076 and RE 50081.
RE 29199/07.05 DREBE10Z Hydraulics Bosch Rexroth AG 5/12

Technical data

Electrical, trigger electronics integrated in valve


Cyclic duration factor % 100 %
Degree of protection IP 65 to DIN 40050 and IEC 14434/5
Connection Plug-in connector 6P+PE, DIN 43563
Supply voltage 24 V DCnom
Terminal A: Min. 21 V DC/max. 40 V DC
Terminal B: 0 V Ripple max. 2 V DC
Power consumption Solenoid 45 mm = 40 VA max.
External fuse 2.5 AF
Input, “standard” version A1 Differential amplifier, Ri = 100 kΩ
Terminal D: UE 0...+10 V
Terminal E: 0V
Input, “mA signal” version F1* Burden, Rsh = 200 Ω
Terminal D: ID–E 4...20 mA
Terminal E: ID–E Current loop ID–E feedback
Max. voltage to differential inputs over 0 V D씮B
E씮B } max. 18 V=
Test signal, “standard” version A1 LVDT
Terminal F: UTest 0...+10 V
Terminal C: Reference 0 V
Test signal, “mA signal” version F1* LVDT signal 4...20 mA at external load 200...500 Ω max.
Terminal F: IF–C 4...20 mA output
Terminal C: IF–C Current loop IF–C feedback
Safety earth conductor and shield See pin assignment (installation in conformity with CE)
Recommended cable See pin assignment
up to 20 m 7 x 0.75 mm2
up to 40 m 7 x 1 mm2
Calibration Calibrated at the factory, see valve curve
* Variant “F1” (4...20 mA version) available on request

Version A1:
Standard
Supply 24V =
Signal: 0…+10V

LVDT Signal: 0…+10V


(Ri = 100kΩ)

B
7
5 * Version F1:
Y X A
mA signal

Supply 24V =
Signal: 4…20mA

LVDT Signal: 4…20mA


(Bürde: 200Ω)

B
1

5
Y X A
6/12 Bosch Rexroth AG Hydraulics DREBE10Z RE 29199/07.05

Connection
For electrical data, see page 5 and
Operating Instructions 1 819 929 083

Technical notes for the cable Important


Version: – Multi-wire cable Power supply 24 V DC nom.,
– Extra-finely stranded wire if voltage drops below 18 V DC, rapid shutdown resembling
to VDE 0295, Class 6 “Enable OFF” takes place internally.
– Safety earth conductor, green/yellow In addition, with the “mA signal” version:
– Cu braided shield ID–E ⭌ 3 mA – valve is active
Type: – e.g. Ölflex-FD 855 CP ID–E ⬉ 2 mA – valve is deactivated.
(from Lappkabel company) Electrical signals emitted via the trigger electronics (e.g. actual
No. of wires: – Determined by type of valve, values) must not be used to shut down safety-relevant machine
plug type and signal assignment functions!
Cable Ø: – 0.75 mm2 up to 20 m long (See also European Standard, “Technical Safety Requirements
for Fluid-Powered Systems and Components – Hydraulics”,
– 1.0 mm2 up to 40 m long
EN 982).
Outside Ø: – 9.4...11.8 mm – Pg 11
– 12.7...13.5 mm – Pg 16
RE 29199/07.05 DREBE10Z Hydraulics Bosch Rexroth AG 7/12

On-board trigger electronics


Circuit diagram/pin assignment
Version A1: UD–E 0...+10 V

Supply UB

Supply zero

Ref. zero *

Setpoint 0...+10 V

Actual value 0...+10 V

Safety earth conductor 쓔

Shield

* Do not connect to supply zero!

Pin assignment
Version A1: UD–E 0...+10 V
(Ri = 100 kΩ)
8/12 Bosch Rexroth AG Hydraulics DREBE10Z RE 29199/07.05

On-board trigger electronics


Circuit diagram/pin assignment
Version F1: ID–E 4...20 mA

OBE 2.5 AF +24 V=


Supply
A 0V
+UB Supply zero
B
+15 V DC C Loop IF–C
-15 V
DC D
Rsh
200Ω E ID–E 4...20 mA
Diff.
F
amp.
4…20mA Test IF–C (4...20 mA)
mA
Logic Safety earth conductor
V
Shield

+UB

+
PID
-

Pin assignment 6P+PE


Version F1: ID–E 4...20 mA
(Rsh = 200 kΩ)
RE 29199/07.05 DREBE10Z Hydraulics Bosch Rexroth AG 9/12

Characteristic curves (measured with HLP 46, oil = 40 °C ±5 °C)


Pressure in port A as a function of the setpoint

* Factory setting at Q = 1 l/min


±5 % manufacturing tolerance
1) Version: UD–E = 0...+10 V
2) Version: ID–E = 4...20 mA

UD-E 1)
[V]

ID-E 2)
4,0 7,2 10,4 13,6 16,8 20 [mA]

Pressure in port A as a function


of the main stage nominal flow rate

p = f (Q)
10/12 Bosch Rexroth AG Hydraulics DREBE10Z RE 29199/07.05

Unit dimensions (nominal dimensions in mm)

Not included in scope of delivery

Mounting hole configuration: NG10 (ISO 5781-AG-06-2-A)


For subplates see catalog sheet RE 45055 Required surface quality
of mating component
1) Deviates from standard
2) Thread depth:

Ferrous metal 1.5 x Ø*


Non-ferrous 2 x Ø
* NG10 min. 10.5 mm

A B X Y G F1 F2 F3 F4
X 27,2 35,8 21,4 21,4 31,8 0 42,9 42,9 20
Y 33,35 33,35 58,7 27,9 66,7 0 20 66,7 66,7
14,7 14,7 24,8 24,8 27,5 M10 2) M10 2) M10 2) M10 2)
RE 29199/07.05 DREBE10Z Hydraulics Bosch Rexroth AG 11/12

Notes
12/12 Bosch Rexroth AG Hydraulics DREBE10Z RE 29199/07.05

Notes

Bosch Rexroth AG © This document, as well as the data, specifications and other information
Hydraulics set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Zum Eisengießer 1 reproduced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No state-
Telefon +49 (0) 93 52 / 18-0 ments concerning a certain condition or suitability for a certain application
Telefax +49 (0) 93 52 / 18-23 58 can be derived from our information. The information given does not release
[email protected] the user from the obligation of own judgement and verification. It must be
www.boschrexroth.de remembered that our products are subject to a natural process of wear and
aging.

You might also like