Total No. of Questions : 8] SEAT No.
8
23
P9081 [Total No. of Pages : 4
ic-
[6179]-206
tat
S.E. (Civil Engineering)
9s
BUILDING TECHNOLOGY & ARCHITECTURAL PLANNING
6:0
(2019 Pattern) (Semester-III) (201001)
02 91
9:2
0
Time : 2½ Hours] [Max. Marks : 70
30
7/1 13
Instructions to the candidates:
1) Answer Q1 or Q2, Q3 or Q4, Q5 or Q6, Q7 or Q8.
0
2/2
.23 GP
2) Neat diagrams must be drawn wherever necessary.
3) Figures to the right side indicate full marks.
E
4) Assume suitable data if necessary.
82
8
C
23
5) Use of scientific calculator is allowed.
ic-
16
tat
Q1) a) Define flooring. Enlist different types of flooring. Explain marble flooring.
8.2
9s
[6]
.24
6:0
91
b) Enlist different types of roofs. Give the functional requirements of good
49
9:2
roofing materials. Draw the sketch of queen post roof truss. [6]
30
30
c) Explain briefly the following aspects applied to doors and windows. [5]
01
02
i) Function or purpose.
2/2
GP
ii) Location
7/1
iii) Size
CE
82
8
OR
23
.23
ic-
Q2) a) What is the factor affecting the selection of flooring materials? [6]
16
tat
b) Explain with proper sketch Casement window. [6]
8.2
9s
c) Enlist types of doors and explain in detail Sliding door. [5]
.24
6:0
91
49
9:2
Q3) a) It is proposed to construct a bungalow for a doctor, the following are the
30
30
requirements for accommodation: [13]
01
02
i) A Drawing Hall-25 Sqm.
2/2
GP
ii) Living Room- 25 Sqm.
7/1
iii) Kitchen cum dining room - 15 Sqm.
CE
82
iv) Guest Room -20 Sqm.
.23
v) Children’s Room -20 Sqm.
16
vi) Master bedroom -20 Sqm.
8.2
vii) Doctors Room - 20 Sqm.
.24
49
[6179]-206 1
viii) Provide adequate verandah, passage, sanitary units, staircase etc.
8
23
as per bye- laws. Consider floor to floor height 3.0M, Size of Riser
ic-
150mm. The structure planned as G+1 RCC structure and draw line
tat
plan for the same.
9s
b) Calculate number of risers and tread in each flight for dog legged stair,
6:0
02 91
floor to floor height is 3.3 m and riser is 150mm. Show with a neat
9:2
0
sketch. [5]
30
7/1 13 OR
0
Q4) a) Write a Short note on Green Building? Enlist various Rating System.[5]
2/2
.23 GP
b) A line plan of a residential building is shown in following figure 1. Draw
detailed floor plan with 1:50 or suitable scale. Use the following data:[13]
E
82
8
C
23
i) All external wall thickness 230mm
ic-
ii) All internal wall thickness 150mm
16
tat
iii) RCC Frame structure
8.2
9s
iv) Floor to floor height -3.2
.24
6:0
v) Plinth Height -0.6
91
49
9:2
vi) Toilet for M.Bed -1 .2 × 2. 1
30
30
vii) All dimensions are in meters
01
02
2/2
GP
7/1
CE
82
8
23
.23
ic-
16
tat
8.2
9s
.24
6:0
91
49
9:2
30
30
01
02
2/2
GP
7/1
CE
82
.23
16
8.2
.24
49
[6179]-206 2
Q5) a) It is proposed to constrcut a Computer Training Institute with the following
8
23
requirements: [13]
ic-
i) Reception: 20 Sqm.
tat
ii) Administrative office: 25 Sqm
9s
iii) Cabin for head of the institute : 25 Sqm
6:0
02 91
iv) Seminar Hall (2Nos) : 60 sqm each
9:2
v) Class room (3 Nos) : 50 Sqm each
0
30
7/1 13
vi) Computer lab(2 Nos): 70 Sqm each
vii) Store Room: 15 Sqm
0
2/2
.23 GP
viii) Staff room with attached toilet : 30 Sqm
ix) All passage : 2 m wide
E
82
x) Sanitary units : as per standards
8
C
23
xi) Assume any suitable data if necessary
ic-
xii) Draw to scale of 1:50 or suitable - line plan showing location of
16
tat
doors and windows
8.2
9s
b) Enlist the functional requirements and salient features of engineering Student
.24
6:0
91
for hostel building. [5]
49
9:2
30
OR
30
01
Q6) a) Design a single storey hostel building and draw only line plan with the
02
2/2
following data [13]
GP
7/1
i) Number of students - 40
CE
82
8
ii) Fifteen rooms are two seated with 7.5 sq. m area per student and
23
ten single seated with 9.5 sq. m area.
.23
ic-
16
iii) Recreation room approx. area 35 Sqm
tat
8.2
9s
iv) Kitchen-9.5 Sqm
.24
6:0
v) Office space approx. area 12 Sqm
91
49
9:2
vi) Store room approx. area 10 Sqm
30
30
vii) Dining - 3 Sqm / student
01
02
viii) Passage -l.8m wide
2/2
GP
ix) Verandah, passage, staircase, W.C. and Bath etc. of suitable size
7/1
CE
should be provided. Show North direction and mention scale.
82
b) Mention the functional requirements with dimensions for a School building.
.23
[5]
16
8.2
.24
49
[6179]-206 3
Q7) a) Explain in detail MRTP 1966 and RER.A [6]
8
23
b) What are different acoustical defects? Explain any one in detail. [6]
ic-
tat
c) Explain in detail 7/12 abstract and describe different village forms. [5]
9s
OR
6:0
02 91
9:2
Q8) a) Elaborate the following terms: [6]
0
30
i) Fire load
7/1 13
ii) Disaster Management
0
2/2
.23 GP
iii) Evacuation Time
E
82
b) Explain ‘One Pipe’ plumbing system [6]
8
C
23
c) Explain need of earthquake resistance structure [5]
ic-
16
tat
8.2
9s
.24
6:0
91
49
9:2
30
30
01
02
2/2
GP
7/1
CE
82
8
23
.23
ic-
16
tat
8.2
9s
.24
6:0
91
49
9:2
30
30
01
02
2/2
GP
7/1
CE
82
.23
16
8.2
.24
49
[6179]-206 4