Eclipse ThermJet Burners

Model TJ0040
Data sheet Edition 9.14
Version 2

Parameter Burner Velocity Model TJ0040


Maximum Input, Btu/h (kW)1 Medium & High Velocity 400,000 (106)
Minimum Input, Btu/h (kW)1
Medium & High Velocity 40,000 (11)
For lower inputs, contact Eclipse, Inc.
Minimum Input Fixed Air, Btu/h (kW)1 Medium & High Velocity 10,000 (3)
Main Gas Inlet Pressure, "w.c. (mbar) High Velocity Natural Gas 12.0 (29.9)
Fuel pressure at gas inlet Propane 13.0 (32.4)
Tap B (see page 3) Butane 12.0 (29.9)
Medium Velocity Natural Gas 5.5 (13.7)
Propane 5.5 (13.7)
Butane 5.0 (12.5)
Air Inlet Pressure, "w.c. (mbar) High Velocity Natural Gas 15.5 (38.6)
15% excess air at maximum input Propane 17.0 (42.3)
Tap A (see page 3) Butane 17.0 (42.3)
Medium Velocity Natural Gas 9.0 (22.4)
Propane 9.5 (23.7)
Butane 9.5 (23.7)
High Fire Visible Flame Length, inches (mm) High Velocity Natural Gas 14.0 (356)
Measured from the outlet end of the combustor Propane 17.0 (432)
Butane 17.0 (432)
Medium Velocity Natural Gas 18.0 (457)
Propane 19.0 (483)
Butane 19.0 (483)
Approximate Flame Velocity, ft/s (m/s) High Velocity 540 (165)
Approximately 15% excess air at maximum input Medium Velocity 320 (98)
Maximum Combustion Air Temperature 300°F (149°C). For higher temperatures use TJPCA (Datasheet 206).
Flame Detection Flame rods can be used with all combustors, any fuel listed below, and
operating temperatures up to 2,200°F (1,204°C).
UV scanners can be used with all combustors, any fuel listed below, and
up to the maximum operating temperature.
Fuels2
Natural gas, Propane or Butane
For any other mixed gas, contact Eclipse, Inc.
Approvals

1. All imperial inputs based upon gross calorific values (HHV). All metric inputs based upon net calorific values (LHV).
2. See Design Guide 205 for more information about typical fuel composition and properties.
• All information is based on laboratory testing in neutral (0 "w.c., 0 mbar) pressure chamber. Different chamber conditions may affect
the data.
• All information is based on standard combustor design. Changes in combustor will alter performance and pressures.
• All inputs based upon standard conditions; 1 atmosphere, 70°F (21°C).
• Eclipse reserves the right to change the construction and/or configuration of our products at any
time without being obliged to adjust earlier supplies accordingly.
• Plumbing of air and gas will affect accuracy of orifice readings. All information is based on generally
acceptable air and gas piping practices.
ThermJet TJ0040, V2, Data sheet, Edition 9.14

Performance Graphs
NOX Emission
@ 1700°F (930°C) Chamber Temperature
Ignition and Operation Zone (High Velocity Combustor)
10,000 90

80
Ignition and
Operational Zone 70

NOX ppm (@ 3% O2)


1,000 60
% Excess Air

50

40

100 30

20
NOX Natural Gas
10 NOX Propane/Butane
10 0
0 100 200 300 400 0 100 200 300 400
Input HHV (x 1,000 Btu/h) Input HHV (x 1,000 Btu/h)

0 20 40 60 80 106 0 20 40 60 80 106
Input LHV (kW) Input LHV (kW)

Emissions correction factor for medium velocity combustor is


1.20. Emissions data based on, on-ratio control firing at 15%
excess air corrected to 3% O2.

Emissions from the burner are influenced by:


• Fuel type
• Combustion air temperature
• Firing rate
• Chamber conditions
• Percent of excess air
For estimates of other emissions, contact Eclipse.

Fuel Orifice ∆p vs. Input


(∆p Measured Between Taps B and D) Air Orifice ∆p vs Input
15.0 6
(∆p Measured Between Taps A and C)
Natural Gas ∆P - 10.8 mm orifice 15.0 6
Propane ∆P - 9.1 mm orifice
12.5 5 Butane ∆P - 9.1 mm orifice Air Orifice (37 mm)
12.5 5

10.0 4
∆P ("w.c. ± 5%)
∆P (mbar ± 5%)

∆P (mbar ± 5%)

∆P ("w.c. ± 5%)

10.0 4

7.5 3 7.5 3

5.0 2 5.0 2

2.5 1
2.5 1

0.0 0
0.0 0 100 200 300 400
0
0 100 200 300 400 Input HHV (x 1,000 Btu/h)
Input HHV (x 1,000 Btu/h)
0 20 40 60 80 106
0 20 40 60 80 106 Input LHV (kW)
Input LHV (kW)
ThermJet TJ0040, V2, Data sheet, Edition 9.14

Dimensions and Specifications


Dimensions in mm (inches)

Burner Housing
2" NPT / Rc 2.0 85
Air Inlet (3.3)

97.5
(3.8)

90 UV Scanner
(3.5) Adapter or
Spark
Plug Flame Rod
Location
Peepsight
167
(6.6)
3/4" NPT / Rc 0.75
Fuel Inlet

Burner weight less combustor: 21.6 lbs (9.8 kg)

Tap Locations
Tap A
Tap C

Tap D
Tap B
ThermJet TJ0040, V2, Data sheet, Edition 9.14

Dimensions and Specifications


Dimensions in mm (inches)

Combustors

Ø136
(5.4)
Ø88.9 Alloy Combustor (AISI 310)
ØA (3.5) Weight: 2.1 lbs (0.95 kg)
Maximum Chamber Temp: 1,750°F (950°C)

B 4 x Ø12 (0.5)

10.2
(0.4)
Ø136
(5.4)
Ø95 Silicon Carbide Combustor
ØC (3.7) Weight: 3.6 lbs (1.6 kg)
Maximum Chamber Temp: 2,500°F (1,371°C)

230
(9.0) 4 x Ø12 (0.5)

6.4
(0.3)
Ø190
(7.5)
Ø146.2 Refractory Combustor with AISI 330 wrapper
(5.8) Weight: 14 lbs (6.4 kg)
Ø143.2
(5.6) Maximum Chamber Temp: 2,800°F (1,538°C)

230
(9.0) 4 x Ø12 (0.5)

NOTE: Mounting gasket shown on right side of combustor flange.


Dimensions shown do not account for mounting gasket.

High Medium
Dimension
Velocity Velocity
ØA Ø45.4 (1.8) Ø63.4 (2.5)
B 212.6 (8.4) 193.3 (7.6)
ØC Ø52 (2.0) Ø70 (2.8)

© Eclipse, Inc. All Rights Reserved