This appliance is not intended for use by persons (including children) with reduced physical,sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
1 Frequency band(s) in which the radio equipment operates 2400MHz-2483.5MHz
2 Maximum radio-frequency power transmitted in the frequency band(s) in which the radio equipment
operates 20dBm
This marking indicates that this product should not be disposed with other household wastes throughout the EU.
To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return your used device, please use the
return and collection systems or contact the retailer where the product was purchased. They can take this
product for environmental safe recycling.
R32: 675
If it needs to install, move or maintain the air conditioner, please contact dealer or local service
center to conduct it at first. Air conditioner must be installed, moved or maintained by appointed
unit. Otherwise, it may cause serious damage or personal injury or death.
Explanation of Symbols
Exception Clauses
Manufacturer will bear no responsibilities when personal injury or
property loss is caused by the following reasons.
1.Damage the product due to improper use or misuse of the product;
2.Alter, change, maintain or use the product with other equipment without abiding
by the instruction manual of manufacturer;
3.After verification, the defect of product is directly caused by corrosive gas;
4.After verification, defects are due to improper operation during transportation of
product;
5.Operate, repair, maintain the unit without abiding by instruction manual or related
regulations;
6.After verification, the problem or dispute is caused by the quality specification or
performance of parts and components that produced by other manufacturers;
7.The damage is caused by natural calamities, bad using environment or force
majeure.
Appliance filled with flammable gas R32.
The Refrigerant
To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The used refrigerant is the fluoride R32, which is specially cleaned.
The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion
under certain conditions. But the flammability of the refrigerant is very low. It can
be ignited only by fire.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R32
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.
WARNING
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture. Should repair be necessary, contact your nea-
rest authorized Service Centre. Any repairs carried out by unqualified personnel
may be dangerous. The appliance shall be stored in a room without continuously
operating ignition sources. (for example: open flames, an operating gas appliance
or an operating electric heater.) Do not pierce or burn.
Appliance shall be installed, operated and stored in a room with a floor area larger
than 10m2.
Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s
instructions only. Be aware that refrigerants may not contain an odour. Read specialist’s
manual.
1
Precautions
WARNING
2
Precautions
WARNING
3
Precautions
WARNING
Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing
the unit.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note the following table. Air switch should be included
magnet buckle and heating buckle function, it can protect
the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the requirement
of air conditioner. Unstable power supply or incorrect wiring
may result in electric shock, fire hazard or malfunction.
Please install proper power supply cables before using the
air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.
4
Precautions
WARNING
5
Precautions
WARNING
For the air conditioner with plug, the plug should be
reachable after finishing installation.
For the air conditioner without plug, an circuit break
must be installed in the line.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Instructions for installation and use of this product are
provided by the manufacturer.
Parts Name
Indoor Unit
air inlet
panel
filter
aux.button
horizontal louver
air outlet
Display
power
temp. indicator
indicator
receiver
window
display
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.
7
Buttons on remote controller
1 ON/OFF button
2 MODE button
3 FAN button
4 TURBO button
▲
5 ▲/ button
6 button
1 7 button
2 3 8 SLEEP button
9 I FEEL button
4
6 10 TIMER ON / TIMER OFF button
5
7 11 CLOCK button
9
8 12 QUIET button
10
11 13 WiFi button
12
13 14 14 LIGHT button
15 16 15 button
16 TEMP button
8
Introduction for buttons on remote controller
Note:
● This is a general use remote controller it could be used for the air conditioners
with multifunction; For some function, which the model doesn't have, if press
the corresponding button on the remote controller that the unit will keep the
original running status.
● After putting through the power, the air conditioner will give out a sound.
Operation indicator " " is ON (red indicator the colour is different for different
models). After that, you can operate the air conditioner by using remote controller.
● Under on status, pressing the button on the remote controller, the signal icon " "
on the display of remote controller will blink once and the air conditioner will give
out a “di” sound, which means the signal has been sent to the air conditioner.
● As for the models with functions of WiFi or wired controller, the indoor unit must
has been controlled by standard remote controller under auto mode first, and then
the function of adjustable temperature under auto mode can be realized by APP
or the wired controller.
● This remote controller can adjust the temperature under auto mode. When matching
with the unit which is without the function of adjustable temperature under auto mode,
the set temperature under auto mode may be invalid, or the displayed set temperature
on the unit is not same as that on the remote controller under auto mode.
1 ON/OFF button
Press this button to turn on the unit. Press this button again to turn off the unit.
2 MODE button
Press this button to select your required operation mode.
AUTO COOL DRY FAN HEAT
● When selecting auto mode, air conditi oner will operate automatically according
to the sensed temperature. Press "FAN" button can adjust fan speed. Press
" " / " " button can adjust fan blowing angle.
● After selecting cool mode, air conditioner will operate under cool mode. Cool
indicator " " on indoor unit is ON (This indicator is not available for some
models). Press "▲" or " " button to adjust set temperature. Press "FAN"
▲
button to adjust fan speed. Press " " / " " button to adjust fan blowing angle.
● When selecting dry mode, the air conditioner operates at low speed under dry
mode. Dry indicator " " on indoor unit is ON (This indicator is not available
for some models). Under dry mode, fan speed can’t be adjusted.
Press " " / " " button to adjust fan blowing angle.
● When selecting fan mode, the air conditioner will only blow fan, no cooling and
no heating. All indicators are OFF,Operation indicator is ON. Press "FAN" button
9
Introduction for buttons on remote controller
to adjust fan speed. Press" " / " " button to adjust fan blowing angle.
● When selecting heating mode, the air conditioner operates under heat mode.
Heat indicator " " on indoor unit is ON (This indicator is not available for some
▲
models). Press "▲" or " " button to adjust set temperature. Press "FAN" button
to adjust fan speed. Press " " / " " button to djust fan blowing angle. (Cooling
only unit won’t receive heating mode signal. If setting heat mode with remote
controller, press ON/OFF button can’t start up the unit).
Note:
● For preventing cold air, after starting up heating mode, indoor unit will delay 1~5
minutes to blow air (actual delay time is depend on indoor ambient temperature).
● Set temperature range from remote controller: 16~30 ℃ (61-86°F);
Fan speed: auto, low speed, low-medium speed,medium speed, medium-high
speed,high speed.
● Under auto mode, temperature can be displayed;Under auto mode,
set temperature can be adjusted.
3 FAN button
This button is used for setting Fan Speed in the sequence that goes from AUTO, ,
, , to , then back to Auto.
Auto
button indoor fan will continue running for a few minutes. at low speed. In this
period, Hold fan speed button for 2s to stop indoor fan directly.
● Having set X-FAN function off: After turning off the unit by pressing ON/OFF
4 TURBO button
Under COOL or HEAT mode, press this button to turn to quick COOL or quick
HEAT mode. " " icon is displayed on remote controller. Press this button again
to exit turbo function and " " icon will disappear.
10
Introduction for buttons on remote controller
If start this function, the unit will run at super-high fan speed to cool or heat quickly
so that the ambient temp. approachs the preset temp. as soon as possible.
5
▲
▲/ button
● Press "▲" or " " button once increase or decrease set temperature 1℃ (°F).
▲
Holding "▲" or " " button, 2s later, set temperature on remote controller will
change quickly. On releasing button after setting is finished, temperature indica-
tor on indoor unit will change accordingly.
● When setting TIMER ON, TIMER OFF or CLOCK, press "▲" or " " button to
▲
adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF buttons).
6
Press this button can select left & right swing angle. Fan blow angle can be selected
circularly as below:
Note:
● Press this button continuously more than 2s, the main unit will swing back an
forth from left to right, and then loosen the button, the unit will stop swinging and
present position of guide louver will be kept immediately.
● Under swing left and right mode, when the status is switched from off to , if
press this button again 2s later, status will switch to off status directly; if press
this button again within 2s, the change of swing status will also depend on the
circulation sequence stated above.
● The function is only available for some model.
7
Press this button can select up & down swing angle. Fan blow angle can be selected
circularly as below:
no display
(horizontal louvers stops
at current position)
● When selecting " ", air conditioner is blowing fan automatically. Horizontal
louver will automatically swing up & down at maximum angle.
● When selecting " 、 、 、 、 ", air conditioner is blowing fan at fixed
position. Horizontal louver will stop at the fixed position.
● When selecting " 、 、 ", air conditioner is blowing fan at fixed angle.
Horizontal louver will send air at the fixed angle.
● Hold " " button above 2s to set your required swing angle. When reaching your
required angle, release the button.
11
Introduction for buttons on remote controller
Note:
● 、 、 " may not be available. When air conditioner receives this signal, the
air conditioner will blow fan automatically.
● Press this button continuously more than 2s, the main unit will swing back an
forth from up to down, and then loosen the button, the unit will stop swinging and
present position of guide louver will be kept immediately.
● Under swing up and down mode, when the status is switched from off to , if
press this button again 2s later, status will switch to off status directly; if press
this button again within 2s, the change of swing status will also depend on the
circulation sequence stated above.
8 SLEEP button
● Press this button, can select Sleep 1 ( ), Sleep 2 ( ), Sleep 3 ( ) and cancel
the Sleep, circulate between these, after electrified, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool modes; sleep status after run for one hour, the
main unit setting temperature will increase 1 , two hours, setting temperature increa-
sed 2 , then the unit will run at this setting temperature; In Heat mode: sleep status
after run for one hour, the setting temperature will decrease 1 , two hours, setting
temperature will decrease 2 , then the unit will run at this setting temperature.
● Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a
group of sleep temperature curve.
● Sleep 3-the sleep curve setting under Sleep mode by DIY;
(1)Under Sleep 3 mode, press “Turbo” button for a long time, remote controller enters
into user individuation sleep setting status, at this time, the time of remote controller
will display “1hour”, the setting temperature “88” will display the corresponding temp-
erature of last setting sleep curve and blink (The first entering will display according to
the initial curve setting value of original factory);
▲
(2)Adjust "▲" and " " button, could change the corresponding setting temperature,
after adjusted, press “Turbo” button for confirmation;
(3) At this time, 1hour will be automatically increased at the timer position on the remote
control, (that are "2hours" or "3hours" or "8hours"), the place of setting temperature "88"
will display the corresponding temperature of last setting sleep curve and blink;
(4) Repeat the above step (2)~(3) operation, until 8 hours temperature setting finished,
sleep,curve setting finished, at this time, the remote controller will resume the original
timer display; temperature display will resume to original setting temperature.
● Sleep3- the sleep curve setting under Sleep mode by DIY could be inquired:
The user could accord to sleep curve setting method to inquire the presetting sleep
curve, enter into user individuation sleep setting status, but do not change the tempera-
ture, press “Turbo” button directly for confirmation. Note: In the above presetting or
enquiry procedure, if continuously within 10s, there is no button pressed, the sleep
curve setting within 10s, there is no button pressed, the sleep curve setting status will
be automatically quit and resume to display the original displaying. In the presetting or
12
Introduction for buttons on remote controller
enquiry procedure, press "ON/OFF" button, "Mode" button, "Timer" button or "Sleep"
button, the sleep curve setting or enquiry status will quit similarly.
9 I FEEL button
Press this button to start I FEEL function and " " will be displayed on the remote
controller. After this function is set, the remote controller will send the detected
ambient temperature to the controller and the unit will automatically adjust the
indoor temperature according to the detected temperature. Press this button again
to close I FEEL function and " " will disappear.
● Please put the remote controller near user when this function is set. Do not put
the remote controller near the object of high temperature or low temperature in
order to avoid detecting inaccurate ambient temperature. When I FEEL function
is turned on, the remote controller should be put within the area where indoor
unit can receive the signal sent by the remote controller.
10 TIMER ON / TIMER OFF button
● TIMER ON button
"TIMER ON" button can set the time for timer on. After pressing this button, " "
icon disappears and the word "ON" on remote controller blinks. Press "▲" or
▲ ▲
" " button to adjust TIMER ON setting. After each pressing "▲" or " " button,
▲
TIMER ON setting will increase or decrease 1min. Hold "▲" or " " button, 2s
later, the time will change quickly until reaching your required time.
Press "TIMER ON" to confirm it. The word "ON" will stop blinking. " " icon
resumes displaying. Cancel TIMER ON: Under the condition that TIMER ON is
started up, press "TIMER ON" button to cancel it.
● TIMER OFF button
"TIMER OFF" button can set the time for timer off. After pressing this button," "
icon disappears and the word "OFF" on remote controller blinks. Press "▲" or
▲ ▲
" " button to adjust TIMER OFF setting. After each pressing "▲" or " " button,
▲
TIMER OFF setting will increase or decrease 1min. Hold "▲" or " " button, 2s
later, the time will change quickly until reaching your required time.
Press "TIMER OFF" word "OFF" will stop blinking. " " icon resumes displaying.
Cancel TIMER OFF. Under the condition that TIMER OFF is started up, press
"TIMER OFF" button to cancel it.
Note:
● Under on and off status, you can set TIMER OFF or TIMER ON simultaneously.
● Before setting TIMER ON or TIMER OFF, please adjust the clock time.
● After starting up TIMER ON or TIMER OFF, set the constant circulating valid.
After that, air conditioner will be turned on or turned off according to setting time.
ON/OFF button has no effect on setting. If you don’t need this function, please
use remote controller to cancel it.
11 CLOCK button
Press this button to set clock time. " " icon on remote controller will blink. Press
13
Introduction for buttons on remote controller
"▲" or " " button within 5s to set clock time. Each pressing of "▲" or " " button,
▲ ▲
clock time will increase or decrease 1 minute. If hold "▲" or " " button, 2s later,
▲
time will change quickly. Release this button when reaching your required time.
Press "CLOCK" button to confirm the time. " " icon stops blinking.
Note:
● Clock time adopts 24-hour mode.
● The interval between two operations can’t exceeds 5s. Otherwise, remote contro-
ller will quit setting status. Operation for TIMER ON/TIMER OFF is the same.
12 QUIET button
Press this button, the Quiet status is under the Auto Quiet mode (display " " and
"AUTO" signal ) and Quiet mode (display " " signal) and Quiet OFF (there is no
signal of " " displayed), after powered on, the Quiet OFF is defaulted.
Note:
● The Quiet function can be set up in all modes; Under the Quiet mode,the fan
speed is not available.
● When quiet function is selected
Under cooling mode: indoor fan operates at notch 4 speed. 10 minutes later or
when indoor ambient temperature≤28℃, indoor fan will operate at notch 2 speed
or quiet mode according to the comparison between indoor ambient temperature
and set temperature.
Under heating mode: indoor fan operates at notch 3 speed or quiet mode according
to the comparison between indoor ambient temperature and set temperature.
Under dry, fan mode: indoor fan operates at quiet mode.
Under auto mode: the indoor fan operates at the auto quiet mode according to
actual cooling, heating or fan mode.
● The Quiet function is only available for some models.
13 WiFi button
Press " WiFi " button to turn on or turn off WiFi function. When WiFi function is
turned on, the " WiFi " icon will be displayed on remote controller; Under status
of remote controller off, press "MODE" and " WiFi " buttons simultaneously for 1s,
WiFi module will restore to factory default setting.
● This function is only available for some models.
14 LIGHT button
Press this button to turn off display light on indoor unit. " " icon on remote
controller disappears. Press this button again to turn on display light. " " icon is
displayed.
15 button
Press this button to achieve the on and off of health and scavenging functions in
operation status. Press this button for the first time to start scavenging function;
14
Introduction for buttons on remote controller
LCD displays " ". Press the button for the second time to start health and
scavenging functions simultaneously; LCD displays " " and " " . Press this
button for the third time to quit health and scavenging functions simultaneous
Press the button for the fourth time to start health function; LCD display " " .
Press this button again to repeat the operation above.
● This function is applicable to partial of models.
16 TEMP button
By pressing this button, you can see indoor set temperature, indoor ambient temp-
erature or outdoor ambient temperature on indoor unit’s display. The setting on
remote controller is selected circularly as below:
no display
● When selecting " " or no display with remote controller, temperature indicator
on indoor unit displays set temperature.
● When selecting " " with remote controller, temperature indicator on indoor unit
displays indoor ambient temperature.
● When selecting " " with remote controller, temperature indicator on indoor unit
displays outdoor ambient temperature.
Note:
● Outdoor temperature display is not available for some models. At that time, indoor
unit receives " " signal, while it displays indoor set temperature.
● It s defaulted to display set temperature when turning on the unit.There is no
display in the remote controller.
● Only for the models whose indoor unit has dual-8 display.
● When selecting displaying of indoor or outdoor ambient temperature, indoor
temperature indicator displays corresponding temperature and automatically turn
to display set temperature after three or five seconds.
Function introduction for combination buttons
Energy-saving function
Under cooling mode, press "TEMP" and "CLOCK" buttons simultaneously to
start up or turn off energy-saving function. When energy-saving function is started
up, "SE" will be shown on remote controller, and air conditioner will adjust the set
temperature automatically according to ex-factory setting to reach to the best
energy-saving effect. Press "TEMP" and "CLOCK" buttons simultaneously again to
exit energy-saving function.
Note:
● Under energy-saving function, fan speed is defaulted at auto speed and it can’t
be adjusted. 15
Function introduction for combination buttons
● Under energy-saving function, set temperature can’t be adjusted. Press "TURBO"
button and the remote controller won’t send signal.
● Sleep function and energy-saving function can’t operate at the same time. If
energy-saving function has been set under cooling mode, press sleep button will
cancel energy-saving function. If sleep function has been set under cooling
mode, start up the energy-saving function will cancel sleep function.
8℃ heating function
Under heating mode, press "TEMP" and "CLOCK" buttons simultaneously to start
up or turn off 8℃ heating function. When this function is started up, " " and "8℃ "
will be shown on remote controller, and the air conditioner keep the heating status
at 8℃ . Press "TEMP" and "CLOCK" buttons simultaneously again to exit 8℃
heating function.
Note:
● Under 8℃ heating function, fan speed is defaulted at auto speed and it can’t be
adjusted.
● Under 8℃ heating function, set temperature can’t be adjusted. Press "TURBO"
button and the remote controller won’t send signal.
● Sleep function and 8℃ heating function can’t operate at the same time. If 8℃
heating function has been set under heating mode, press sleep button will cancel
8℃ heating function. If sleep function has been set under heating mode, start up
the 8℃ heating function will cancel sleep function.
● Under ℉ temperature display, the remote controller will display 46 ℉ heating.
16
Operation guide
1. After putting through the power, press "ON/OFF" button on remote controller to
turn on the air conditioner.
2. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN,
HEAT.
3. Press "▲" or " " button to set your required temperature. (Temperature can’t
▲
NOTICE
● During operation, point the remote control signal sender at the receiving
window on indoor unit.
● The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.
● Signal may be interfered easily in the room where there is fluorescent lamp
or wireless telephone; remote controller should be close to indoor unit during
operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please
replace batteries.
17
Emergency operation
air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
panel
aux. button
WARNING:
Use insulated object to press the auto button
WARNING
■ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
■ Do not use liquid or corrosive detergent clean the appliance and do not splash
water or other liquid onto it, otherwise, it may damage the plastic components,
even cause electric shock.
NOTICE:
● Do not remove the panel when cleaning it.
18
Clean and Maintenance
Open panel
1 Pull out the panel to a certain
3 ● Use dust catcher or water to
4
panel cover tightly.
WARNING
19
Clean and Maintenance
20
Malfunction analysis
General phenomenon analysis
21
Malfunction analysis
Phenomenon Check items Solution
22
Malfunction analysis
Phenomenon Check items Solution
23
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indicator on indoor unit will
C5
F0
F1
F2
H3 It can be eliminated after restarting the unit. If not, please
Note: If there're other error codes, please contact qualified professionals for
service.
WARNING
■ When below phenomenon occurs, please turn off air conditioner and discon-
for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Air switch trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
24
NOTE CONCERNING PROTECTION OF ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must
be taken to a collection station for the recycling of electrical and electronic devices. The symbol
on the product, the operating instructions or the packaging indicate such disposal procedures.
The materials are recyclable in accordance with their respective symbols. By means of re-use,
material recycling or any other form of recycling old appliances you are making an important
contribution to the protection of our environment. Please ask your local council where your
nearest disposal station is located.
In case of quality problem or other please contact your local supplier or authorized service center.
Emergency number: 112
PRODUCER
REPRESENTATIVE
TECHNICAL SUPPORT