The JA-114HN BUS four-input and four-output module

The JA-114HN is a device of the JABLOTRON 100 system. 1. Put the module into the control panel or into an installation box.
It provides 4 wired inputs with configurable balancing, 4 galvanically a. When installation is performed in a JA-190PL installation box,
separated PG outputs and an output for an auxiliary power supply then the front tamper contact (4) has to be enabled. The rear
protected by an electronic fuse. It allows you to pre-set the type of tamper contact (7) is also recommended to be enabled and
balancing for each input and also the value of the balancing resistors. equipped with a spring from the supplied accessories. Make a
The outputs are designed to be galvanically isolated (2 of them always hole inside the JA-190PL box and put the spring of the rear
use the C terminal as a common potential). The module occupies tamper contact through the hole.
4 positions in the system and is equipped with a front and a rear tamper b. When the module is installed in the JA-10xK control panel
contact. The product should be installed by a trained technician with disable the front (4) and rear (7) tamper contacts. The module
a valid certificate issued by an authorised distributor. is protected by the control panel’s own tamper contacts.
c. When installation in another Jablotron installation box is
Device description required, always pay attention to its installation manual. For the
The module provides 4 inputs, 4 PG outputs and an auxiliary power installation to comply with the EN 50131 norm, security grade 2
supply. It is appropriate for the restructure of older wired systems where it is necessary to ensure the minimum functioning of the front
the detectors remain the same. Thanks to the setting variability of the tamper contact (4) or ensure protection against tampering with
balancing resistors for every input it is not necessary to intervene in the the whole installation box.
already-existing installation. 2. Connect the BUS cable to the BUS terminals (2) and the required
inputs (3), outputs (1) and auxiliary power (5).
Very often the module is used to control several appliances using the
PG outputs. The auxiliary power supply feature can power an additional
relay connected to signal output. Inputs can provide feedback about the When connecting the module to the BUS,
current appliance status to the system. always switch the power off.
Basic features of the inputs, outputs and the auxiliary
When the module is placed outside the
power supply: protected premises, it is necessary to protect
the BUS cable to the module by a JA-110T BUS
isolator.
To set the module to comply with security
grade 2 use F-Link SW, Parameters tab and the
option “Perform EN50131-1”. (See the JA-10xK
control panel installation manual)

3. Proceed according to the control panel installation manual. Basic


procedure:
a. When the system is switched on, the yellow LED starts
flashing repeatedly to indicate that the module has not been
enrolled to the system yet.
b. Go to the F-Link software, select the required position in the
Devices tab and launch enrollment mode by clicking on the
Enroll option.
Figure no. 1: Wiring example c. Clicking on the Add new BUS devices select the JA-114HN
INPUTS (INPUTS 1 – 4): The inputs serve as wired connections for module and by a double press confirm enrolling. The yellow
wired zones i.e. unbalanced, single balanced, double balanced LED goes off.
or Roller mode (according to Figure 1). The connection method can be 4. Set the module parameters such as the functions of inputs and
different for every input (every input has an individual setting and also outputs; see the chapter Setting the module properties.
values for balancing resistors). We strongly recommend using 5. Close the cover of the installation box or control panel.
balancing resistors with a minimum tolerance of 10%. The COM and 6. Test input and output functions via the F-Link SW with the
GND terminals are connected together. Diagnostics tab. Pay attention especially to the line voltage drop
when the auxiliary power is used and when PG outputs are used.
OUTPUTS (OUT 1 – 4): Galvanically separated PG outputs which
Switch everything on to simulate a state of maximum current.
switch to the C terminals. The output pair always use the common
terminal C. The switching current and voltage should not exceed Notes:
500 mA / 38 V.  The module can be enrolled to the system by entering its
AUXILIARY POWER (+U and GND): The terminals provide production code in the F-Link software. All numbers under the bar
a voltage with a maximum current of 200 mA for powering detectors, code shall be entered (example: 1400-00-0000-0001).
Pod Skalkou 4567/33 | 46601 | Jablonec n. Nisou

auxiliary power relays, contactors or other electric appliances. The The production code is printed on the sticker and glued on module
output is protected by an electronic fuse and when a short circuit terminals.
occurs, the module internally disconnects the output and the system  Enrolling can be also performed by pressing the front tamper
shows a module fault. When the short circuit disappears the module contact (4).
JABLOTRON ALARMS a.s.

restores the voltage.  The number of modules is limited by the current provided from the
Czech Republic | www.jablotron.com

control panel BUS terminals and the number of positions available


Installation in the control panel.
The module is designed to be installed in a JA-19xPL installation box  When the system is switched on, loading the default statuses can
(Jablotron), or right in the control panel (JA-10xK). take up to 1 minute.
 Caution! To enroll the module to the system the next 3 positions
have to be free. If the following 3 positions are already occupied,
they will be overwritten. When there are not enough positions at
the end of the list of devices, only a limited number of inputs will
be enrolled to fill in the rest of the positions.
 If less than 4 inputs are to be used, mark the specific input’s
position in F-link and using the “Delete” key release it for another
device.

Setting the module properties


The module properties can be set in the Devices tab of the F-Link
software. When at the module position, use Internal settings options
to open a dialogue window where you can set the following
parameters (* factory settings):
Figure 2: 1 – PG output (1-4) terminals; 2 – BUS terminal,
3 – Input (1-4) terminals; 4 – Front tamper contact; 5 – Output for auxiliary LED indication: Enabled *: A short flash by the red LED indicates
power (+U, GND); 6 – PG output status LED indicators; activation / deactivation on any input.
7 – Rear tamper contact

The JA-114HN BUS four-input and four-output module 1/2 MLN57104


The JA-114HN BUS four-input and four-output module
Front tamper contact: Disabled *: parameter enables / disables the Balancing resistor / EOL: it is meant for a Single balanced loop and
front tamper contact. for a Double balanced loop. The default value is 1k0*.
Rear tamper contact: Disabled *: parameter enables / disables the For a Single balanced loop select the RACT value of balancing resistor
rear tamper contact. from the pre-set options. The last option is Optional, it accesses the
Inputs 1 to 4: tabs with complete settings for the inputs. The settings Value Ract parameter. Here simply fill in the required value in kŸ
can be different for every input. (max. 10 k). As a separator use a decimal point or the “k” symbol.
F-Link checks the entered value and if it´s out of range or invalid, the
Functions of an input: Enabled*
option is red.
Disabled – doesn´t react (input is disabled).
For a Double balanced loop select the RTMP and RACT value of resistor
Enabled – reacts to a change of the contact connected to the input for the detection of tampering and activation from the pre-set values
(standby = NC), see figure in the F-Link SW. (the selected value is valid for both resistors). The last option is
Single balanced – An RACT resistor has to be put in series with an Optional, it accesses the Value Ract, Value Rtmp and Multiplicity
ACT activation contact (see figure in F-Link). To set its value use the parameters (max. 5). These parameters allow you to select specific
Balancing resistor parameter, it is immediately visible when you select values of resistors and to choose how many detectors are going to be
this function. The input is activated when the resistance of the loop used in one loop. Select the resistors values from the offered list or
changes by 30%. simply fill in the required value in kŸ(max. 10 k). As a separator use a
Double balanced – An RTMP resistor has to be put in series with a decimal point or the “k” symbol. F-Link checks the entered value and if
TMP tamper contact and the activation contact has to be bridged it´s out of range or invalid, the option is red.
connected in parallel by an RACT resistor (see Figure 3 and in F-Link Delayed input reaction: a time filter for increasing immunity and to
SW). To set its value, use the Balancing resistor parameter. The values supress false activations, 0.5 s* (options 0.1 s … 300 s). It tells you how
of the RTMP and RACT balancing resistors can be different, see the long the input has to be activated to trigger an alarm in the control
Balancing resistor parameters. panel. For the functions Double balanced and Double balanced Oasis
The loop can have up to 3 states: Standby – the value of measured the option range is from 0.5 s to 300 s.
loop resistance equals RTMP. Activation – the value of measured loop Copy of input settings: thanks to this button you can copy the
resistance equals RTMP + RACT (if multiples are needed it is RTMP + n * settings of a currently programmed input to another input of the same
RACT). Tamper – the value of measured loop resistance is different than module.
previous values. To ensure reliable detection the device assumes a Outputs: Disabled*: A tab where a specific PG of the control panel
resistivity tolerance (r 30%). can be assigned to specific outputs 1 – 4 (1). When several PG outputs
are assigned to one output then it is driven by OR logic (when one PG
output is ON then the output is also ON). The Test button checks the
PG output function. When the PG output is switched ON it is indicated
by a red LED (6) at the specific output and by a red light in the F-Link
SW indication field (next to the Test button). When the internal settings
window is closed all outputs are switched off.
Input measuring / diagnostics: here at this tab you can see the
currently measured resistance at a specific input (loop). Graphic
representation fully respects the input settings (function, balancing and
its value). It visualizes the current status of the measured value. Thanks
to the recording of measured values over time it shows a visible curve
with all changes and you can test all detectors this way.

Figure no. 3: Double balanced loop Technical specifications


Double balanced Oasis – settings of the input module are fully Power from control panel BUS 12 V DC (9 – 15 V)
compatible with parameters of the input modules and control panels of Current consumption:
Oasis systems. This mode allows you to connect up to 5 detectors in - Nominal consumption - to calculate backup 11 mA
one loop (see Figure no. 4 and in F-Link SW). all inputs connected to GND
The loop can have up to 3 states: Standby – the value of measured (+ consumption of connected devices)
loop resistance is from 700 Ÿ to 1.3 kŸ, Activation – the value of - Maximal consumption - for cable selection 26 mA
measured loop resistance is from 1.4 kŸ - 7.8 kŸ, Tamper – the (+ consumption of connected devices)
measured loop resistance is lower than 600 Ÿ or higher than 7.9 kŸ. Voltage from +U 12 V DC (9 – 15 V)
Maximum acceptable load from +U (electronic fuse) < 200 mA
Maximum acceptable current / voltage switched by each output
500 mA/38 V
Max. measured resistance at input 20 kȍ
Max. cable length connected to inputs 100 m
Dimensions 77 x 40 x 31 mm
Weight 26 g
Classification security grade 2/environmental class II
- according to EN 50131-1, EN 50131-3 (ACE type B)
- enviroment Indoor general
- operational temperature range -10 to +40 °C
- average humidity 75 %, non-condensing
- certification body Trezor Test s.r.o. (no. 3025)
Figure 4: Double balanced loop - OASIS Also complies with EN 50130-4, EN 55022
Rollerblind (roller) – reacts to short repeated pulses with a sensitivity JABLOTRON ALARMS a.s. hereby declares that
adjustable to two levels: Impulse 1 = activation by 3 pulses the JA-114HN is in a compliance with the relevant Union
within 2 minutes max.; Impulse 2 = activation by 5 pulses harmonisation legislation: Directives No: 2014/30/EU,
within 2 minutes max. 2011/65/EU. The original of the conformity assessment can
Input inverted reaction: can be used for an Enabled or Single be found at www.jablotron.com - Section Downloads.
balanced input. The default (disabled) reaction is set to disconnection
from COM (NC)*. By enabling this option you can set the opposite Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer
reaction to grounding (NO).
or directly to the producer after use.
Impulse: can be used for all functions except Roller. The default
option is disabled*, the input works in status mode. It means that the
input reacts to disconnection / connection (activation and deactivation)
of the loop from / to ground. Enabling this input option will only react to
activation (connection or disconnection of GND according to the
Inverted input reaction option). After 2 s it goes to standby
automatically.

The JA-114HN BUS four-input and four-output module 2/2 MLN57104