LIFE SHELL LABS INDIA PVT. LTD.

lac-MRA (TheComplete Environmental Service Provider)


No. 20, Nchru Street, Maruthi Nagar, Phase I,
l lyyappanthangal, Chennai - 600 077. Tamil Nadu
Cethcate No TC-12026
Tel: +9I(44) 48634849, 63809 68684
Email : [email protected] Web: www.Islipl.com Scope TC-12026
NABL Accredited, ISO 9001: 2015, ISO 45001 : 2018 Certified Company

TEST REPORT

Sample ID: 2408457 JOE: 2883 Report Date: 04.09.2024


Customer Name M/S IOTA TechnicalConsultancy Pvt Ltd
Address No.26, SakthiColony, Ramakrishna Puram, Ganapathy Coimbatore, TamilNadu, India.
Date of Sampling NA Sampled by Customer

Sample Received on 31.08.2024 Sample Deseription STP RAW SEWAGE

Test Commenced on 31.08.2024 Sampling Procedure NA

Test Completed on 04.09.2024 Sample Condition Satisfactory


Sampling Location Valankulam Lake Inlet-1 Sample Quantity Iliter

DISCIPLINE CHEMICAL TESTING


PRODUCT GROUP POLLUTION & ENVIRONMENT

S. No. PARAMETERS UNIT TEST METHOD RESULTS

pH @ 25°C IS 3025-Part 11 7.14 7.13


2 Turbidity mgl IS 3025 Part 10:1984 53.6 4A3-9
3 Total Dissolved solids mg/l IS3025-Part 16 430
4 Total suspended solids
mg/|
IS 3025 Part-17 o3.1
mg/l
5 Chemical Oxygen Demand APHA-24th Edn-2023 9 475
6 BOD @27°C for 3 days mg/l IS 3025-Part 44 36 Bo2
7 Dissolved Oxygen mg/1 IS3025 Part 38:1989 3.6 Ni
8 Total Kjeldahl Nitrogen mg/l IS 3025-Part 34 6.6
39.2
Note: BDL: Below Detectable Limit; DL: Detectable Limit.
For Life Shell Labs India Pvt. Ltd,

LABS
INDIA
Verified by Authorized Signatory
CHENNAI
60C 077

Page I of 3

Note : I) The results listed herewith are only for the items tested. 2) Endorsement of test item is neither inferred nor implied. 3) The report in full or part shall not be used for any
promotional activity or publicity purpose without written consent by us. 4) Samples are not drawn by us unless otherwise mentioned. 5) Unless specifically requested by the customer,
the test items will not be retained more than 7days from the date of issued of the test report. 6) Under no circumstances, lab accepts any liability for loss / damage causcd by use or
misuse of test report. 7)Liability is limited to proven willful negligence and will in no case be more than the invoiced amount.
LIFE SHELL LABS INDIA PVT. LTD.
(The Complete Environmental Service Provider)
No. 20, Nehru Street, Maruthi Nagar, Phase I, lyyappanthangal, Chennai - 600 077. Tamil Nadu
Ip Tel : +9I (44) 48634849, 63809 68684 Email : [email protected] Web: www.lslipl.com
NABL Accredited, ISO 9001 :2015, ISo 45001: 2018Certified Company

TEST REPORT
Sample ID: 2408457 JOE: 2883 Report Date: 04.09.2024
Customer Name M/S IOTA TechnicalConsultancy Pvt Ltd
Address No.26, Sakthi Colony, Ramakrishna Puram, Ganapathy Coimbatore, Tamil Nadu, India.
Date of Sampling NA Sampled by Customer
Sample Received on 31.08.2024 Sample Deseription STP RAW SEWAGE
Test Commenced on 31.08.2024 Sampling Procedure NA
Test Completed on 04.09.2024 Sample Condition Satisfactory
Sampling Location Valankulam Lake Inlet-1 Sample Quantity Iliter

DISCIPLINE CHEMICAL TESTING


PRODUCT GROUP POLLUTION & ENVIRONMENT
S. No. PARAMETERS UNIT TEST METHOD RESULTS

Total Nitrogen mg/l IS 3025 Part 34 11.9 7)


2 Total Phosphorous as PO4 mg/l IS 3025-Part 31 BDL (DL:0.1) |2 4
Note: BDL: Below Detectable Limit: DL: Detectable Limit.
For Life Shell Labs India Pvt. Ltd,

LABS

Verified by
CHENNAI INDLA Authorized Signatory

Page 2 of3

Note : 1) The results listed herewith are only for the items tested. 2) Endorsement of test item is neither inferred nor implied. 3) The report in full or part shall not be used for any
promotional activity or publicity purpose without written consent by us, 4) Samples are not drawn by us unless otherwise mentioned. 5) Unless specifically requested by the customer,
the test items willnot be retained more than 7days from the date of issued of the test report. 6) Under no circumstances, lab accepts any liability for los / damage caused by use or
misuse of test report. 7) Liability is limited to proven willful negligence and will in no case be more than the invoiced amount.
LIFE SHELL LABS INDIA PVT. LTD.
iiac MRÁ (The Complete Environmental Service Provider)
No. 20, Nchru Street, Maruthi Nagar, Phase I,
Iyyappanthangal, Chennai-600 077. Tamil Nadu
Certificate No TG-12026
Tel: +91(44) 48634849, 63809 68684
Email : [email protected] Web: www.lslipl.com Scope TC-12026
NABL Accredited, ISO 9001 : 2015, ISo 45001 : 2018 Cerified Company
TEST REPORT
Sample lD: 2408457 JOE: 2883 Report Date: 04.09.2024
Customer Name MIS IOTA Technical Consultancy Pvt Ltd
Address No.26, Sakthi Colony, Ramakrishna Puram, Ganapathy Coimbatore, Tamil Nadu, India.
Date of Sampling NA Sampled by Customer
Sample Received on 31.08.2024 Sample Description STP RAW SEWAGE
Test Commenced on 31.08.2024 Sampling Procedure NA
Test Completed on 04.09.2024 Sample Condition Satisfactory
Sampling Location Valankulam Lake Inlet-1 Sample Quantity 1liter

DISCIPLINE BIOLOGICAL TESTING


PRODUCT GROUP POLLUTION & ENVIRONMENT
S. No. PARAMETERS UNIT TEST METHOD RESULTS
1 Fecal Coliform MPN/10Oml APHA-24th Edn-2023 110
2 E. coli MPN/I00ml APHA-24h Edn-2023 80 500
Note: MPN: Most Probable Number.
For Life Shell Labs India Pvt. Ltd,

Verified by Authorized by

ICHENNAI
077
**ot Repoy**

Page 3 of3

Note : 1) The results listed herewith are only for the items tested. 2) Endorsement of test item is neither inferred nor implied. 3) The report in full or part shall not be used for any
promotional activity or publicity purpose without written consent by us. 4) Samples are not drawn by us unless otherwise mentioned. 5) Unless specifically requested by the customer,
the test items will not be retained more than 7days from the date of issued of the test report. 6) Under no circumstances, lab accepts any liability for loss / damage caused by use or
misuse of test report. 7) Liability is limited to proven willful negligence and will in no case be more than the invoiced amount.
LIFE SHELL LABS INDIA PVT. LTD.
iac-MRA (The Complete Environmental Service Provider)
No. 20, Nehru Street, Maruthi Nagar, Phase I,
lyyappanthangal, Chennai - 600 077. Tamil Nadu
Certificato No TC-12026
Tel : +91 (44) 48634849, 63809 68684
Email : [email protected] Web : www.Islipl.com Scope TC-12026
NABL Accredited, ISO 9001: 2015, ISO 45001: 2018 Certified Company

TEST REPORT
Sample ID: 2408454 JOE: 2883 Report Date: 04.09.2024
Customer Name MIS IOTA Technical Consultancy Pvt Ltd
Address
No.26, SakthiColony, Ramakrishna Puram, Ganapathy Coimbatore, Tamil Nadu, India.
Date of Sampling NA Sampled by Customer
Sample Received on 31.08.2024 Sample Description STP RAW SEWAGE
Test Commenced on 31.08.2024 Sampling Procedure NA
Test Completed on 04.09.2024 Sample Condition Satisfactory
Sampling Location Valankulam Lake Inlet-2 Sample Quantity 1liter

DISCIPLINE CHEMICAL TESTING


PRODUCT GROUP POLLUTION & ENVIRONMENT
S. No. PARAMETERS UNIT TEST METHOD RESULTS

pH @ 25°C IS 3025-Part I 1 7.89

2 Turbidity mg/l IS3025 Part 10:1984 89.2


3 Total Dissolved solids mg/l IS 3025-Part 16 1879

4 Total suspended solids mg/l IS 3025 Part-17 231

Chemical Oxygen Demand mg/|


APHA-24h Edn-2023 624 4q
6 BOD @27°Cfor 3 days mg/l IS 3025-Part 44 145
7 Dissolved Oxygen mg/l IS3025 Part 38:1989 NIL
8 Total Kjeldahl Nitrogen mg/l IS 3025-Part 34 67.4
Note: BDL: Below Detectable Limit; DL: Detectable Limit.
For Life Shell Labs India Pvt. Ltd,

LABS
Verified by
L feHENNAI(NDIA
60C 077
Authorized Signatory

geof3

Note : 1) The results listed herewith are only for the items tested. 2) Endorsement of test item is neither inferred nor implied. 3) The report in full or part shall not be used for any
promotional activity or publicity purpose without written consent by us. 4) Samples are not drawn by us unless otherwise mentioned. 5) Unless specifically requested by the customer,
the test items will not be retained more than 7 days from the date of issued of the test report. 6) Under no circumstances, lab accepts any liability for loss / damage caused by use or
misuse of test report. 7) Liability is limited to proven willful negligence and will in no case be more than the invoiced amount.
LIFE SHELL LABS INDIA PVT. LTD.
(The Complete Environmental Service Provider)
ikac-MRA No. 20, Nchru Strect. Maruthi Nagar, Phase I.
Iyyappanthangal, Chennai -600 077. Tamil Nadu
Certfcate No TC 12026
Tel : +91 (44) 48634849, 63809 68684
(s p Scope TC-12026
Email : [email protected] Web: www.Islipl.com
NABL Accredited, ISO 9001 : 2015, ISo 45001 : 2018 Certified Company

TEST REPORT

Sample ID: 2408455 JOE: 2883 Report Date: 04.09.2024


Customer Name M/S IOTA Technical Consultancy Pvt Ltd
Address No.26, Sakthi Colony, Ramakrishna Puram,Ganapathy Coimbatore, Tamil Nadu, India.
Date of Sampling NA Sampled by Customer

Sample Received on 31.08.2024 Sample Description STP RAW SEWAGE


Test Commenced on 31.08.2024 Sampling Procedure NA

Test Completed on 04.09.2024 Sample Condition Satisfactory


Sampling Location Valankulam Lake Inlet-3 Sample Quantity Iliter

DISCIPLINE CHEMICAL TESTING


PRODUCT GROUP POLLUTION & ENVIRONMENT

S. No. PARAMETERS UNIT TEST METHOD RESULTS

1 pH @25°C IS 3025-Part 1| 6.34

2 Turbidity mg/l IS 3025 Part 10:1984 105

3 Total Dissolved solids mg/l IS 3025-Part 16 1432

4 Total suspended solids mgl IS 3025 Part-17 287

5 Chemical Oxygen Demand mg/l APHA-24h Edn-2023 S10 32%


6 BOD @27°C for 3 days mg/l IS 3025-Part 44 130 56
Dissolved Oxygen mg/1 IS3025 Part 38:1989 NIL

8 Total Kjeldahl Nitrogen mg/l IS 3025-Part 34 101


Note: BDL: Below Detectable Limit: DL: Detectable Limit.
For Life ShellLabs India Pvt. Ltd,

LABSIND,
Verified by Authorized Signatory
(CHENNAL
60C 077

Page 1of 3

Note : 1) The results listed herewith are only for the items tested. 2))Endorsement of test item is neither inferred nor implied. 3) The report in full or part shall not be used for any
promotional activity or publicity purpose without written consent by us. 4) Samples are not drawn by us unless otherwise mentioncd. 5) Unless specifically requested by the customer,
the test items will not be retained more than 7 days from the date of issued of the test report. 6) Under no circumstances, lab accepts any liability for loss / damage caused by use or
misuse of test report. 7) Liability is limited to proven willful negligence and will in no case be more than the invoiced amount.
LIFE SHELL LABS INDIA PVT. LTD.
ac-MRA (The Complete Environmental Service Provider)
No. 20, Nehru Strcet, Maruthi Nagar, Phase I.
lyyappanthangal, Chennai - 600 077. Tamil Nadu
Certfcate No TC-12026
Tel: +91 (44) 48634849, 63809 68684
LsL Email : [email protected] Web: www.lslipl.com Scope TC-12026
NABL Accredited, ISO 9001 : 2015, ISO 45001 : 2018 Certified Company

TEST REPORT
Sample ID: 2408456 JOE: 2883 Report Date: 04.09.2024
Customer Name MIS IOTA Technical Consultancy Pvt Ltd
Address No.26, Sakthi Colony, RamakrishnaPuram, Ganapathy Coimbatore, Tamil Nadu, India.
Date of Sampling NA Sampled by Customer
Sample Received on 31.08.2024 Sample Description STP RAW SEWAGE
Test Commenced on 31.08.2024 Sampling Procedure NA
Test Completed on 04.09.2024 Sample Condition Satisfactory
Sampling Location Valankulam Lake Inlet-4 Sample Quantity 1Jiter

DISCIPLINE CHEMICAL TESTING


PRODUCT GROUP POLLUTION & ENVIRONMENT
S. No. PARAMETERS UNIT TEST METHOD RESULTS

pH @ 25°C IS 3025-Part 11 6.91

2 Turbidity mg/l 1S 3025 Part 10:1984 182

3 Total Dissolved solids mg/l IS 3025-Part 16 2109

4 Total suspended solids mg/l IS 3025 Part-17 287


mg/|
Chemical Oxygen Demand APHA-24th Edn-2023 679

BOD @27°C for 3 days mg/l IS 3025-Part 44 198

7 Dissolved Oxygen mg/1 IS3025 Part 38:1989 NIL

8 Total Kjeldahl Nitrogen mg/l IS 3025-Part 34 87.9


Note: BDL:Below Detectable Limit; DL: Detectable Limit.
For Life Shell Labs India Pvt. Ltd,

SHEABSINOAd
Verified by CHANNAI Authorized Signatory
60C 072

Page 1of 3

Note : ) The results listed herewith are only for the items tested. 2) Endorsement of test item is neither inferred nor implied. 3) The report in full or part shall not be used for any
promotional activity or publicity purpose without written consent by us. 4) Samples are not drawn by us unless otherwise mentioned. 5) Unlesspecifically requested by the customer,
the test items will not be retained more than 7days from the date of issucd of the test report. 6) Under no circumstances, lab accepts any liability for loss / damage caused by use or
misuse of test report. 7) Liability is limited to proven willful negligence and willin no case be more than the invoiced amount.
LIFE SHELL LABS INDIA PVT. LTD.
(The Complete Environmental Service Provider)
No. 20, Nehru Street, Maruthi Nagar, Phase I, Iyyappanthangal, Chennai - 600 077. Tamil Nadu
S p Tel : +91 (44) 48634849, 63809 68684 Email : [email protected] Web : www.lslipl.com
NABL Accredited,ISO 9001 : 2015, ISO 45001 :2018 Certified Company

TEST REPORT

Sample ID: 24084S6 JOE: 2883 Report Date: 04.09,2024


Customer Name M/SIOTA Technical Consultancy Pvt Ltd
Address No.26, Sakthi Colony, Ramakrishna Puram, Ganapathy Coimbatore, Tamil Nadu, India.
Date of Sam pling NA Sampled by Customer

Sample Received on 31.08.2024 Sample Description STP RAW SEWAGE


Test Commenced on 31.08.2024 Sampling Procedure NA

Test Completed on 04.09.2024 Sample Condition Satisfactory


Sampling Location Valankulam Lake Inlet-4 Sample Quantity Iliter

DISCIPLINE CHEMICAL TESTING


PRODUCT GROUP POLLUTION & ENVIRONMENT

S. No. PARAMETERS UNIT TEST METHOD RESULTS

Total Nitrogen mg/ IS 3025 Part 34 201

2 Total Phosphorous as PO. mg/l IS 3025-Part 31 2.92

Note: BDL:Below Detectable Limit; DL: Detectable Limit.


For Life Shell Labs India Pvt. Ltd,

Verified by Authorized Signatory


fCHANNAI
60C077

Page 2 of1

Page 2 of3

Note : 1) The results listed herewith are only for the items tested. 2) Endorsement of test item is neither inferred nor implied. 3) The report in full or part shall not be used for any
promotional activity or publicity purpose without written consent by us. 4) Samples are not drawn by us unless otherwise mentioncd. 5) Unless specifically requested by the customer,
the test items will not be retained more than 7 days from the date of issued of the test report. 6) Under no circumstances, lab accepts any liability for loss / damage caused by use or
misuse of test report. 7) Liability is limited to proven willful negligence and will in no case be more than the invoiced amount.
LIFE SHELL LABS INDIA PVT. LTD.
ilacMRÁ (The Complete Environmental Service Provider)
No. 20, Nehru Street, Maruthi Nagar, Phase I,
Iyyappanthangal, Chennai - 600 077. Tamil Nadu
Certficate No.TC-12026
Tel : +91 (44) 48634849, 63809 68684
Email : [email protected] Web: www.Islipl.com Scope TC- 12026
NABL Accredited, ISO 9001 : 2015, ISO 45001 : 2018 Certified Company

TEST REPORT

Sample ID: 2408456 JOE: 2883 Report Date: 04.09.2024


Customer Name MIS IOTATechnical Consultancy Pvt Ltd
Address No.26, Sakthi Colony,Ramakrishna Puram, Ganapathy Coimbatore, Tamil Nadu, India.
Date of Sampling NA Sampled by Customer
Sample Received on 31.08.2024 Sample Description STP RAW SEWAGE
Test Commenced on 31.08.2024 Sampling Procedure NA
Test Completed on 04.09.2024 Sample Condition Satisfactory
Sampling Location Valankulam Lake Inlet-4 Sample Quantity 1liter

|DISCIPLINE BIOLOGICAL TESTING


PRODUCT GROUP POLLUTION & ENVIRONMENT
S. No. PARAMETERS UNIT TEST METHOD RESULTS
Fecal Coliform MPN/100ml APHA-24h Edn-2023 1600
2 E. coli MPN/I0Oml APHA-24h Edn-2023 1600
Note: MPN: Most Probable Number.

For Life Shell Labs India Pvt. Ltd,

Verified by BS
AB Authorized by

EHENNY

Page 3 of3

Note : 1) The results listed herewith are only for the items tested. 2) Endorsement of test item is neither inferred nor implied. 3) The report in full or part shall not be used for any
promotional activity or publicity purposc without written consent by us. 4) Samples are not drawn by us unless otherwise mentioned. 5) Unless specifically requested by the customer,
the test items will not be retained more than 7days from the date of issued of the test report. 6) Under no circumstances, lab accepts any liability for loss / damage caused by usc or
misuse of test report. 7)Liability is limited to proven willful negligence and will in no case be more than the invoiced amount.