OEC One

Digital Mobile C-arm


Technical Data
Superb imaging. Made more accessible.

All-in-one system design, connected touchscreen image display monitor and TechView tablet, optimized image processing
and dose management software all provide a superb image quality experience. OEC One is designed to enable an optimal
surgical imaging experience and OR team efficiency for a variety of procedures.

• Save space around the table with all-in-one system design



• Easily position image display monitor by utilizing
articulating arm connecting the display to the system

• Access images via touchscreen and intuitive interface

• Capture the right image at the right dose with brilliant
dose management platform

• Enjoy advanced connectivity including wireless DICOM


with enterprise security and 2.4 GHz/5 GHz, MPPS, and
digital/analog video output options

• Protect data with battery backup

gehealthcare.com/surgery Availability of select models, configurations, and options varies by country.


Please contact your local sales representative.
Technical Specifications

X-ray System
Radiographic • mA: 20 (10 for 100 - 120V system)
Generator • 40 kHz high frequency Mode • mAs: up to 80 (40 for 100 - 120V
• 2.2 kW power system)
• Up to 110 kVp • Film cassette holder (optional):
• Continuous high level fluoroscopy supports sizes 24 cm x 30 cm and
(HLF) up to 12 mA 10” x 12”
• Radiographic film exposure up to
20 mA (10 mA for 100 - 120V system) Image Processing
• Digital spot up to 20 mA (10 mA for
100 - 120V system) AutoTrak • Automatically seeks the subject
Automatic anatomy anywhere within the
Brightness imaging field and selects the optimum
X-ray Tube • Stationary anode X-ray tube Stabilization imaging technique by varying mA,
• Dual focal spot: (ABS) kVp, and gain
- Small focal spot: 0.6 x 1.4 • Automatically adjusts to anatomical
- Large focal spot: 1.4 size and location
• Tube assembly total filtration: 3.35 • Provides uniform image quality
mm Al throughout the entire image
• Anode heat capacity: 76,000 HU • Simplifies image acquisition
• Anode cooling rate: 37,000 HU/min
• Housing heat capacity: 900,000 HU
• Housing cooling rate: 12,500 HU/min Smart Window • Dynamically senses the collimator
position and automatically adjusts
• On-screen tube heat capacity
brightness and contrast to produce
indicator
high image quality

PreView • On-screen collimator position


Smart Metal • Provides optimum image quality
Collimator indication even when metal is introduced into
• PreView iris collimator the field by adjusting brightness and
• PreView tungsten rotatable double contrast automatically and allowing
leaf collimator user to adjust sensitivity levels
• Adjusts collimators without X-ray
exposure
Adaptive • Reduces blooming when capturing
Dynamic Range images of anatomy with varying
Fluoroscopy • kVp range: 40 - 110 Optimization density
Mode • mA range: 0.1 – 4 normal (ADRO) • Enhances anatomy of interest while
0.1 – 2 low dose attenuating background features
0.2 – 12 HLF
• Auto and manual fluoroscopy modes Noise and • Optimizes image quality by reducing
Motion Artifact noise
Pulsed • kVp range: 40 - 110 Reduction • Reduces lag and improves detail
Fluoroscopy Mode • mA range: 0.1 – 4 normal in images when moving the C-arm,
0.1 – 2 low dose repositioning anatomy of interest,
0.2 – 12 HLF or introducing a tool into the field of
• Pulse rate: 1, 2, 4, 8 pps view
• Auto and manual pulsed fluoroscopy
modes Image Presetting • High contrast or high dynamic range
• Reduces X-ray dose to patient and
operator

Digital Spot Mode • kVp range: 40 - 110


• mA range: up to 20 (up to 10 mA for
100 - 120V system)
• Automatic exposure termination and
automatic image save

Availability of select models, configurations, and options varies by country.


OEC One Technical Data
Please contact your local sales representative.
Technical Specifications

Image Acquisition Image Display


9” Image • Tri-mode 23 cm/16 cm/12 cm Image Display • 69 cm (27”) high definition LCD
Intensifier (9”/6”/4.5”) image intensifier Monitor display
• DQE: 65% (typical) • 30 cm (11.8”) image view of both live
• Typical central resolution at image and reference images
intensifier: • Anti-reflection and anti-smudge
- 23 cm (9”): 52 lp/cm • 600 Cd/m2 maximum brightness
- 16 cm (6”): 58 lp/cm • Monitor mounted on an articulating
- 12 cm (4.5”): 68 lp/cm arm
• Nominal central resolution at image - Viewable from all four sides of
display monitor: system
- 23 cm (9”): 2.2 lp/mm - Position monitor by crossing
- 16 cm (6”): 2.8 lp/mm articulating arm above C-arm within
- 12 cm (4.5”): 3.3 lp/mm system footprint
- 210° swivel at mainframe and 180°
Tungsten • Denser collimator limits X-ray swivel at center of arm
Collimator exposure area - 40 cm (15.8”) up/down vertical
• Reduces scatter radiation travel
• Improves image detail - 180° image display monitor swivel
- 5° up/25° down tilt
- 178° horizontal and vertical viewing
Anti-Scatter Grid • Reduces scatter radiation effect
angle
• Improves image detail
• 1920 x 1080 high resolution
• PB 8/40, f0 100
• Touchscreen system control

Video Camera • High resolution 1k x 1k CCD camera TechView Tablet • 26 cm (10.1”) tablet with touchscreen
• Full digital interface system control
• Variable gain control - 30° up/10° down tilt
- 270° side/side swivel
- 160° horizontal and vertical viewing
angle
• 1280 x 800 high resolution

External Video • DVI-D output - one port


Output (optional) - Full screen
- 1920 x 1080 high resolution
• BNC output - one port
- Left image view
- NTSC/PAL
- 16:9/4:3

Availability of select models, configurations, and options varies by country.


OEC One Technical Data
Please contact your local sales representative.
Technical Specifications

Software Package User Interface • Touchscreen control on both image


display monitor and TechView tablet
Standard Offering • Dynamic recursive filter with
simplifies operation
adaptation to motion
- Allows user to adjust noise filter • Quick mode
levels to produce high image quality - No password needed
- Provides optimum image quality - Basic imaging function available
even when motion is introduced to • Multifunctional controls
the field - Footswitch with save button
• Automatic digital brightness and - Handswitch
contrast control • Exams
• Manual digital brightness and - Patient-centric view of exams
contrast control - Manual deletion of exam(s)
• Auto adaptive non-uniformity - Display multi-modality exams
correction - View older exams
• Image edge enhancement - Search saved/scheduled exams
• Negate mode • X-ray dose summary - export or print
• Save and auto-save • Radiation Dose Structured Report
• Swap and auto-swap (RDSR)
• Last image hold • Multipurpose image directory
• Image zoom and roam - Retrieve and review images
• Left-right image reversal - Export images
• Top-bottom image invert - Import images
• Digital image rotation - Delete images
- 360 degree real-time rotation for live • Set-up functions
and static images - Multi-language
- Image positioning without additional - Date/time
exposure - DICOM interface
• HIPAA SecureView - Wireless network
- Password protection • Room-in-use indicator interface
- Blank screen function • 3-position key switch for enabling/
- Delete all patient information disabling X-rays and lift movement
• 100,000 image storage - X-ray and lift movement are disabled
- X-ray and lift movement are enabled
- X-ray is disabled and lift movement
DICOM • Basic DICOM (optional) is enabled
- DICOM worklist
- DICOM storage
- DICOM print
• DICOM Query and Retrieve (optional)
• DICOM MPPS (optional)
• Wireless DICOM (optional)

Image • Image measurement (optional)


Measurement - Distance
and - Angles
Annotation - Multi-unit support (French, mm,
inch)
- User calibration
• Image annotation (optional)

Availability of select models, configurations, and options varies by country.


OEC One Technical Data
Please contact your local sales representative.
Technical Specifications

Brilliant Dose • Superb imaging with dose efficiency Pediatric • Removable grid and additional filter
Management - High DQE (65%) image intensifier Application Kit (optional)
Platform - Anti-scatter grid
- Hardware and software design C-arm Positioning • Laser aimer on image intensifier
provide balance of dose and image (optional)
Aides
quality
• Laser aimer on tube side (optional)
- Dynamic camera gain control for low
dose imaging
- Full digital image processing Uninterruptible • Patient image data protection
• Dose reduction positioning Power • Controlled shutdown
- Laser aimer on image intensifier • Accidental power loss protection
(optional)
- Laser aimer on tube side (optional) Electrical • Input power (60 Hz or 50 Hz)
- PreView collimator - 100V/110V/120V @ 20A
- Skin spacer (optional) - 200V @ 12A
- Real-time rotation for static images - 220V/230V/240V @ 10A
• Provide real-time dose information
- Dose rate, accumulative dose, DAP
- Multi-unit support (Gy, Rad) Operating Range • Temperature range: 10° to 40° C
• Low dose imaging mode for pediatrics (50° to 104° F)
- Removable grid and additional filter • Humidity range: 20% to 80%
(optional)
- Low dose mode Regulatory • IEC60601-1 ED3.1 with collateral and
- Pulsed imaging mode Compliance particular standards
• Dose summary data output and • IEC6061-1-2: 2007 and IEC6061-1-2:
archive 2014
- Dose summary export and print out • GB9706.1,GB9706.3, GB9706.12,
- Dose information transfer via DICOM • GB9706.11, GB9706.14,
(RDSR) GB9706.15,GB 7247.1-2012
• 21 CFR Subchapter J part 1020.30-32
Additional Features • 21 CFR Subchapter J part 1040.10-11
• IEC 61910-1: 2014 Radiation dose
Connectivity • USB - two ports
structured reports
• Film/paper printer compatible
• DICOM printer support
- Multi-format: 1x1, 1x2, 2x1, 2x2, 2x3,
3x3, 3x4, 4x4, 4x5, 5x4
- Multi-copy capability
• Radiographic film cassette holder
(optional)
• Ethernet - one port
• Wireless Ethernet data transfer
(optional)
- 802.11 a/b/g/n
- 2.4 GHz/5 GHz
- Support WEP encryption, WPA/
WPA2-Personal and Enterprise
- Seamless roaming
• Room interface - one port

Availability of select models, configurations, and options varies by country.


OEC One Technical Data
Please contact your local sales representative.
Physical Specifications

System
Length 179 cm (70.5 in)
Height 179 cm (70.5 in)
Width 78 cm (30.7 in)
Weight 310 kg (683 lbs)
C-arm
SID 100 cm (39.4 in)
Free space in arc 78 cm (30.7 in)
Depth in arc 66 cm (26.0 in)
Orbital rotation 120° (90° underscan/30° overscan)
Lateral rotation 410° (+205°/-205°)
Lateral height 102 cm (40.2 in)
Wig/wag 25° (+12.5°/-12.5°)
Horizontal travel 20 cm (7.9 in)
Vertical travel 44 cm (17.3 in)
Image Display Monitor Arm
Swivel at mainframe 210° (+90°/-120°)
Swivel at center of arm 180° (+170°/-10°)
Image display vertical travel 40 cm (15.8 in): 20 cm (7.9 in) up/ 20 cm (7.9 in) down
Image display swivel 180° (+90°/-90°)
Image display tilt 30° (+5°/-25°)
TechView Tablet
Swivel 270˚ (+135˚/-135˚)
Tilt 40˚ (+30˚/-10˚)

Availability of select models, configurations, and options varies by country.


OEC One Technical Data
Please contact your local sales representative.
System Dimensions

Availability of select models, configurations, and options varies by country.


OEC One Technical Data
Please contact your local sales representative.
Image Display Monitor Arm – Range of Motion

210°

Swivel at mainframe

180°

Swivel at center of arm

Image display vertical travel

Image display swivel

180°

Image display tilt

Availability of select models, configurations, and options varies by country.


OEC One Technical Data
Please contact your local sales representative.
Image Display Positions

Forward travel Vertical travel Vertical travel

TechView Tablet – Range of Motion

30°

10°

Tilt Swivel

Availability of select models, configurations, and options varies by country.


OEC One Technical Data
Please contact your local sales representative.
Availability of select models, configurations, and options varies by country.
Please contact your local sales representative.

Imagination at work

©2017 General Electric Company – All rights reserved.

General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the
product described at any time without notice or obligation. Contact your GE Representative for the most current information.
GE, GE Monogram and OEC are trademarks of General Electric Company. GE OEC Medical Systems, Inc., doing business as
GE Healthcare.

JB51832XX(2)

You might also like