3500-MSB60-SIGD-0040-09 ANNEX 1 MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Rev.10 January 24th 2020
3500-MSB60-SIGD-0040-09 ANNEX 1 MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Rev.10 January 24th 2020
Technical specification
Maintenance
EPC: Name: MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Rev.10 January 24th 2020
Client: Modec Brazil Unit ID: Sub contr:
Cons/Eng: Version: 10 Date: 26-Mar-20
Project: MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Rev.10 January 24th 2020
Prepared by: Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Page 1 of 45
Summary
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Page 4 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position A1 - Structural Steel Including Pipe Supports (Where blasting is not permited/possible - Use of ISO 12944-2 category N/A
Brush or Roller)
Substrate Carbon Steel Area 100 m² No. 1
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations. General
recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to (ISO 12944-
2): CX: 100mg/m2. Can also be applied by surfaces prepared to Wa 2½ (ISO 8501-4).Surface preparation to Wa2 is accepted. Maximum accepted grade
of flash rust is L.
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
%
BARRIER SMART PACK,GREY FC 100 70 60 86 30 6h 2 mth 2.5 h 1 mth 1h 7d 17 5 9 12
JOTAMASTIC SMART PACK HB,ALUMINIUM FC 100 78 160 205 30 21 h 10 d 11 h 7d 4h 5d 17 5 21 29
HARDTOP AX,NONE FC 100 63 60 95 30 10 h * 5h * 3h * 10 5 10 14
Total 280
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4- Can by applied by brush: roller or airless.
5- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 5 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position A1 - Structural Steel Including Pipe Supports (Alternative System) ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 2
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations. General
recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to (ISO 12944-
2): CX: 100mg/m2. Can also be applied by surfaces prepared to Wa 2½ (ISO 8501-4).Surface preparation to Wa2 is accepted. Maximum accepted grade
of flash rust is L.
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTAMASTIC 87,ALUMINIUM RED TONED FC 100 87 225 259 30 24 h * 10 h * 4h * 17 %
5 26 37
JOTAMASTIC 87,STD 038 GREY FC 100 82 225 274 30 24 h 14 d 10 h 10 d 4h 5d 17 5 27 39
HARDTOP AX,NONE FC 100 63 60 95 30 10 h * 5h * 3h * 10 5 10 14
Total 510
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4- Can by applied by brush: roller or airless.
5- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 6 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030; Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat; not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4- Can by applied by brush: roller or airless.
5- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 7 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030; Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat; not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4- Can by applied by brush: roller or airless.
5- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 8 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position A2 - Module Deck - Non Slip Escape Route ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 5
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX: 100mg/m2 . Can also be applied by surfaces prepared to Wa 2½ (ISO 8501-4).Surface preparation to Wa2 is accepted. Maximum
accepted grade of flash rust is L.
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
BARRIER SMART PACK,GREY FC 100 70 60 86 30 6h 2 mth 2.5 h 1 mth 1h 7 d 17 %
5 9 12
JOTAMASTIC SMART PACK HB,ALUMINIUM FC 100 78 160 205 30 21 h NR 11 h NR 4h NR 17 5 21 29
JOTUN ANTI-SKID,NONE FC 100 100 0 0 30 * NR * NR * NR 5 0 0
HARDTOP AX,NONE FC 100 63 60 95 30 10 h * 5h * 3h * 10 5 10 14
Total 280
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030; Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat; not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4-Jotun Anti-Skid is should be spread into the last coat in of the coating system; giving an anti-skid effect.
5- Can by applied by roller or airless.
6- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 9 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position A2 - Module Deck - Non Slip Escape Route (Alternative System) ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 6
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX: 100mg/m2 . Can also be applied by surfaces prepared to Wa 2½ (ISO 8501-4).Surface preparation to Wa2 is accepted. Maximum
accepted grade of flash rust is L.
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTAMASTIC 87,ALUMINIUM RED TONED FC 100 87 225 259 30 24 h * 10 h * 4h * 17 %
5 26 37
JOTAMASTIC 87,STD 038 GREY FC 100 82 225 274 30 24 h NR 10 h NR 4h NR 17 5 27 39
JOTUN ANTI-SKID,NONE FC 100 100 0 0 30 * NR * NR * NR 5 0 0
HARDTOP AX,NONE FC 100 63 60 95 30 10 h * 5h * 3h * 10 5 10 14
Total 510
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030; Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat; not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4-Jotun Anti-Skid is should be spread into the last coat in of the coating system; giving an anti-skid effect.
5- Can by applied by roller or airless.
6- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 10 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 11 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4- System to be applied only when specified from project construction phase.
5- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 12 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B1 - Carbon Steel Un-Insulated Temp. from -29 < T ≤ 100 deg C ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 9
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX: 100mg/m2. Can also be applied by surfaces prepared to Wa 2½ (ISO 8501-4).Surface preparation to Wa2 is accepted. Maximum
accepted grade of flash rust is L.
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
BARRIER SMART PACK,GREY FC 100 70 60 86 30 6h 2 mth 2.5 h 1 mth 1h 7 d 17 %
5 9 12
JOTAMASTIC SMART PACK HB,ALUMINIUM FC 100 78 160 205 30 21 h 10 d 11 h 7d 4h 5d 17 5 21 29
HARDTOP AX,NONE FC 100 63 60 95 30 10 h * 5h * 3h * 10 5 10 14
Total 280
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4- Can by applied by brush: roller or airless.
5- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 13 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B1 - Carbon Steel Un-Insulated Temp. from -29 < T ≤ 100 deg C (Alternative System) ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 10
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX: 100mg/m2. Can also be applied by surfaces prepared to Wa 2½ (ISO 8501-4).Surface preparation to Wa2 is accepted. Maximum
accepted grade of flash rust is L.
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTAMASTIC 87,ALUMINIUM RED TONED FC 100 87 225 259 30 24 h * 10 h * 4h * 17 %
5 26 37
JOTAMASTIC 87,STD 038 GREY FC 100 82 225 274 30 24 h 14 d 10 h 10 d 4h 5d 17 5 27 39
HARDTOP AX,NONE FC 100 63 60 95 30 10 h * 5h * 3h * 10 5 10 14
Total 510
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4- Can by applied by brush: roller or airless.
5- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 14 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B2 - Carbon Steel Un-Insulated Temp. from 100 < T ≤ 200 deg C and -29 deg C and lower ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 11
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX: 100mg/m2. Can also be applied by surfaces prepared to Wa 2½ (ISO 8501-4).Surface preparation to Wa2 is accepted. Maximum
accepted grade of flash rust is L.
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
EPOXY HR,LIGHT GREY FC 100 63 125 198 30 26 h 21 d 10 h 7d 4h 3 d 23 %
5 20 28
EPOXY HR,ALUMINIUM FC 100 63 125 198 30 26 h * 10 h * 4h * 23 5 20 28
Total 250
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
3- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 15 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B3 - Carbon steel uninsulated 200 < T ≤ 400 deg C ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 12
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX: 100mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTATEMP 1000 CERAMIC,DARK GREY FC 100 75 125 167 30 24 h * 6h * 3.5 h * 7 %
5 17 24
JOTATEMP 1000 CERAMIC,ALUMINIUM FC 100 75 125 167 30 24 h * 6h * 3.5 h * 7 5 17 24
Total 250
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 16 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B4 - Carbon Steel Insulated Temp. from -29 < T ≤ 100 deg C ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 13
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX: 100mg/m2. Can also be applied by surfaces prepared to Wa 2½ (ISO 8501-4).Surface preparation to Wa2 is accepted. Maximum
accepted grade of flash rust is L.
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
BARRIER SMART PACK,GREY FC 100 70 60 86 30 6h 2 mth 2.5 h 1 mth 1h 7 d 17 %
5 9 12
JOTAMASTIC SMART PACK HB,ALUMINIUM FC 100 78 200 256 30 21 h * 11 h * 4h * 17 5 26 37
Total 260
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
3- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 17 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B4 - Carbon Steel Insulated Temp. from -29 < T ≤ 100 deg C (Alternative System) ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 14
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX: 100mg/m2. Can also be applied by surfaces prepared to Wa 2½ (ISO 8501-4).Surface preparation to Wa2 is accepted. Maximum
accepted grade of flash rust is L.
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTAMASTIC 87,ALUMINIUM RED TONED FC 100 87 225 259 30 24 h * 10 h * 4h * 17 %
5 26 37
JOTAMASTIC 87,STD 038 GREY FC 100 82 225 274 30 24 h * 10 h * 4h * 17 5 27 39
Total 450
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030; Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat; not to build up thickness. FC=Full Coat / SC = Strip Coat.
3- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 18 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B5 - Carbon Steel Insulated Temp. from 100 < T ≤ 200 deg C and -29 deg C and lower ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 15
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX: 100mg/m2. Can also be applied by surfaces prepared to Wa 2½ (ISO 8501-4).Surface preparation to Wa2 is accepted. Maximum
accepted grade of flash rust is L.
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
EPOXY HR,LIGHT GREY FC 100 63 125 198 30 26 h 21 d 10 h 7d 4h 3 d 23 %
5 20 28
EPOXY HR,ALUMINIUM FC 100 63 125 198 30 26 h * 10 h * 4h * 23 5 20 28
Total 250
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
3- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 19 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B6 - Carbon steel insulated 200 < T ≤ 400 deg C ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 16
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX: 100mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTATEMP 1000 CERAMIC,DARK GREY FC 100 75 125 167 30 24 h * 6h * 3.5 h * 7 %
5 17 24
JOTATEMP 1000 CERAMIC,ALUMINIUM FC 100 75 125 167 30 24 h * 6h * 3.5 h * 7 5 17 24
Total 250
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030; Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat; not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 20 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030; Rev.0
* Related to fireproof protection a technical query shall be done for each specific case.
-To ensure correct Passive Fire Protection (PFP) please consult Jotun for thickness calculations.
-Topcoat application is optional as Jotun's position. However; unless otherwise specified; Modec requires topcoat as common practice for chalking protection
and coloring purpose.
- Please consult which Jotun primer can be used for this system.
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat; not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
For longer durability and performance of paint system surfaces to be coated shall be degreased to ISO 12944-4; Part 6.1.4 Fresh water cleaning; and abrasive
blast cleaned to Sa 2½ (ISO 8501-1) with a minimum surface profile 45 µm; grade Fine to Medium G; Ry5 (ISO 8503-2) or to SSPC-VIS 3 SP11.
Page 21 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B8 316/316L, duplex stainless steel and super duplex stainless steel, Copper Niquel and ISO 12944-2 category N/A
Titanium, Un-insulated -29 < T ≤ 100 deg C
Substrate Stainless Steel Area 100 m² No. 18
Surface Prep. After pre-treatment of welds, sharp edges, removal of weld spatter and other surface contamination the surface shall be degreased with an alkaline
detergent, washed by low-pressure Water Cleaning LP WC method to ISO 8501-4 Wa 1 or higher and hand or machine abraded with non-metallic
abrasives or bonded fibre machine or hand abrasive pads to remove all polish and to impart a scratch pattern to the surface. Do not use high speed
rotational sanders.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas
to (ISO 12944-2): CX: 100mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
PENGUARD PRIMER,RED FC 100 51 50 98 30 8h 3 mth 4h 3 mth 3h 2 mth 17 %
5 10 14
JOTAMASTIC 87,STD 038 GREY FC 100 82 150 183 30 24 h 14 d 10 h 10 d 4h 5d 17 5 18 26
HARDTOP AX,NONE FC 100 63 60 95 30 10 h * 5h * 3h * 10 5 10 14
Total 260
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030; Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat; not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4- Necessity of paint application shall be followed the section 4.2.2 (2500-M380-00S1-0030). It depends on conditions of with/ without thermal insulation;
substrate material; internal fluid; maximum operating temperature.
5- System to be applied only when specified from project construction phase.
6- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 22 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B9 316/316L, duplex stainless steel and super duplex stainless steel Un-insulated 100 < T ≤ 200 ISO 12944-2 category N/A
deg C
Substrate Stainless Steel Area 100 m² No. 19
Surface Prep. After pre-treatment of welds, sharp edges, removal of weld spatter and other surface contamination the surface shall be degreased with an alkaline
detergent, washed by low-pressure Water Cleaning LP WC method to ISO 8501-4 Wa 1 or higher and hand or machine abraded with non-metallic
abrasives or bonded fibre machine or hand abrasive pads to remove all polish and to impart a scratch pattern to the surface. Do not use high speed
rotational sanders.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas
to (ISO 12944-2): CX: 100mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
EPOXY HR,LIGHT GREY FC 100 63 125 198 30 26 h 21 d 10 h 7d 4h 3 d 23 %
5 20 28
EPOXY HR,ALUMINIUM FC 100 63 125 198 30 26 h * 10 h * 4h * 23 5 20 28
Total 250
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- Necessity of paint application shall be followed the section 4.2.2 (2500-M380-00S1-0030). It depends on conditions of with/ without thermal
insulation;substrate material;internal fluid;maximum operating temperature.
4- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 23 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B10 - 316/316L, duplex stainless steel and super duplex stainless steel Un-Insulated 200 ≤ T ISO 12944-2 category N/A
Substrate Stainless Steel Area 100 m² No. 20
Surface Prep. After pre-treatment of welds, sharp edges, removal of weld spatter and other surface contamination the surface shall be degreased with an alkaline
detergent, washed by low-pressure Water Cleaning LP WC method to ISO 8501-4 Wa 1 or higher and hand or machine abraded with non-metallic
abrasives or bonded fibre machine or hand abrasive pads to remove all polish and to impart a scratch pattern to the surface. Do not use high speed
rotational sanders.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas
to (ISO 12944-2): CX: 100mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTATEMP 1000 CERAMIC,DARK GREY FC 100 75 125 167 30 24 h * 6h * 3.5 h * 7 %
5 17 24
JOTATEMP 1000 CERAMIC,ALUMINIUM FC 100 75 125 167 30 24 h * 6h * 3.5 h * 7 5 17 24
Total 250
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- Necessity of paint application shall be followed the section 4.2.2 (2500-M380-00S1-0030). It depends on conditions of with/ without thermal
insulation;substrate material;internal fluid;maximum operating temperature.
4- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 24 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B11 - 316/316L, duplex stainless steel and super duplex stainless steel Insulated T ≤ 200 ISO 12944-2 category N/A
Substrate Stainless Steel Area 100 m² No. 21
Surface Prep. After pre-treatment of welds, sharp edges, removal of weld spatter and other surface contamination the surface shall be degreased with an alkaline
detergent, washed by low-pressure Water Cleaning LP WC method to ISO 8501-4 Wa 1 or higher and hand or machine abraded with non-metallic
abrasives or bonded fibre machine or hand abrasive pads to remove all polish and to impart a scratch pattern to the surface. Do not use high speed
rotational sanders.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas
to (ISO 12944-2): CX: 100mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
EPOXY HR,LIGHT GREY FC 100 63 125 198 30 26 h 21 d 10 h 7d 4h 3 d 23 %
5 20 28
EPOXY HR,ALUMINIUM FC 100 63 125 198 30 26 h * 10 h * 4h * 23 5 20 28
Total 250
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- Necessity of paint application shall be followed the section 4.2.2 (2500-M380-00S1-0030). It depends on conditions of with/ without thermal
insulation;substrate material;internal fluid;maximum operating temperature.
3- System to be applied only when specified from project construction phase.
4- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 25 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B12 - 316/316L, duplex stainless steel and super duplex stainless steel Insulated 200 < T ISO 12944-2 category N/A
Substrate Stainless Steel Area 100 m² No. 22
Surface Prep. After pre-treatment of welds, sharp edges, removal of weld spatter and other surface contamination the surface shall be degreased with an alkaline
detergent, washed by low-pressure Water Cleaning LP WC method to ISO 8501-4 Wa 1 or higher and hand or machine abraded with non-metallic
abrasives or bonded fibre machine or hand abrasive pads to remove all polish and to impart a scratch pattern to the surface. Do not use high speed
rotational sanders.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas
to (ISO 12944-2): CX: 100mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTATEMP 1000 CERAMIC,DARK GREY FC 100 75 125 167 30 24 h * 6h * 3.5 h * 7 %
5 17 24
JOTATEMP 1000 CERAMIC,ALUMINIUM FC 100 75 125 167 30 24 h * 6h * 3.5 h * 7 5 17 24
Total 250
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- Necessity of paint application shall be followed the section 4.2.2 (2500-M380-00S1-0030). It depends on conditions of with/ without thermal
insulation;substrate material;internal fluid;maximum operating temperature.
3- System to be applied only when specified from project construction phase.
4- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 26 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B2 - B3 - B5 - B6 - Carbon Steel Insulated and Un-Insulated Temp. from 100 < T ≤ 250 deg C and - ISO 12944-2 category N/A
29 deg C and lower (Alternative System)
Substrate Carbon Steel Area 100 m² No. 23
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX: 100mg/m2. Can also be applied by surfaces prepared to Wa 2½ (ISO 8501-4).Surface preparation to Wa2 is accepted. Maximum
accepted grade of flash rust is L.
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTATEMP 250,LIGHT GREY FC 100 70 150 214 30 13 h 4 d * 2.5 h 1 d * 1.5 h 6 h * 23 %
5 21 31
JOTATEMP 250,ALUMINIUM FC 100 70 150 214 30 13 h * 2.5 h * 1.5 h * 23 5 21 31
Total 300
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030; Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat; not to build up thickness. FC=Full Coat / SC = Strip Coat.
3- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 27 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position B9 - B10 - B11 - B12 - 316/316L, duplex stainless steel and super duplex stainless steel Insulated ISO 12944-2 category N/A
and Un-insulated 100 < T ≤ 250 deg C (Alternative System)
Substrate Stainless Steel Area 100 m² No. 24
Surface Prep. After pre-treatment of welds, sharp edges, removal of weld spatter and other surface contamination the surface shall be degreased with an alkaline
detergent, washed by low-pressure Water Cleaning LP WC method to ISO 8501-4 Wa 1 or higher and hand or machine abraded with non-metallic
abrasives or bonded fibre machine or hand abrasive pads to remove all polish and to impart a scratch pattern to the surface. Do not use high speed
rotational sanders.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas
to (ISO 12944-2): CX: 100mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTATEMP 250,LIGHT GREY FC 100 70 150 214 30 13 h 4 d * 2.5 h 1 d * 1.5 h 6 h * 23 %
5 21 31
JOTATEMP 250,ALUMINIUM FC 100 70 150 214 30 13 h * 2.5 h * 1.5 h * 23 5 21 31
Total 300
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030; Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat; not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- Necessity of paint application shall be followed the section 4.2.2 (2500-M380-00S1-0030). It depends on conditions of with/ without thermal insulation;
substrate material; internal fluid; maximum operating temperature.
4- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 28 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position C1 - Totally submerged structural steel, piping, and equipment ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 25
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For Submerged Hull to
(ISO 12944-2): Im1 / Im2 / Im4: 80mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTAMASTIC 87,ALUMINIUM RED TONED FC 100 87 250 287 30 24 h 18 d 10 h 14 d 4h 14 d17 %
5 29 41
JOTAMASTIC 87,STD 038 GREY FC 100 82 250 305 30 24 h * 10 h * 4h * 17 5 30 44
Total 500
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 29 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position C2 - Totally submerged galvanized and Aluminium parts. ISO 12944-2 category N/A
Substrate Galvanized Steel Area 100 m² No. 26
Surface Prep. After removal of excess zinc and surface defects the area to be coated shall be degreased with an alkaline detergent, washed by low-pressure Water
Cleaning LP WC method to ISO 8501-4 Wa 1 or higher and the surface abraded using mechanical or hand sanding methods using non-metallic abrasives
or bonded fibre abrasive pads to remove all polish and to impart a scratch pattern to the surface. Do not use high speed rotational sanders.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For Submersed Hull to
(ISO 12944-2): Im1 / Im2 / Im4: 80mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
PENGUARD PRIMER,RED FC 100 51 50 98 30 8h NR 4h NR 3h NR 17 %
5 10 14
JOTAMASTIC 87,ALUMINIUM RED TONED FC 100 87 225 259 30 24 h 18 d 10 h 14 d 4h 14 d 17 5 26 37
JOTAMASTIC 87,STD 038 GREY FC 100 82 225 274 30 24 h * 10 h * 4h * 17 5 27 39
Total 500
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 30 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position D1 - Interior Surfaces of Fresh Water Storage Tanks ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 27
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations. General
recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For Fresh or Drink Water Tanks
to (ISO 12944-2): Im1 / Im4: 20mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTAGUARD 100,MUNSELL N9.5 FC 100 98 150 153 30 * * 9h 6d 3h 3 d 17 %
5 15 22
JOTAGUARD 100,MUNSELL N9.5 SC 10 98 0 0 30 * * 9h 6d 3h 3d 17 5 0 0
JOTAGUARD 100,MUNSELL N9.5 SC 10 98 0 0 30 * * 9h 6d 3h 3d 17 5 0 0
JOTAGUARD 100,MUNSELL N9.5 FC 100 98 150 153 30 * * 9h * 3h * 17 5 15 22
Total 300
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
(Jotaguard 100 is recommended for maintenance as can be applied over ST3;Tankguard 412 requires SA 2 1/2).
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 31 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position D2 - Interior Surfaces of Drink Water Tanks ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 28
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations. General
recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For Fresh or Drink Water Tanks
to (ISO 12944-2): Im1 / Im4: 20mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTAGUARD 100,MUNSELL N9.5 FC 100 98 150 153 30 * * 9h 6d 3h 3 d 17 %
5 15 22
JOTAGUARD 100,MUNSELL N9.5 SC 10 98 0 0 30 * * 9h 6d 3h 3d 17 5 0 0
JOTAGUARD 100,MUNSELL N9.5 SC 10 98 0 0 30 * * 9h 6d 3h 3d 17 5 0 0
JOTAGUARD 100,MUNSELL N9.5 FC 100 98 150 153 30 * * 9h * 3h * 17 5 15 22
Total 300
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
(Jotaguard 100 is recommended for maintenance as can be applied over ST3;Tankguard 412 requires SA 2 1/2).
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 32 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position D3 - Interior Surfaces of Glycol and Diesel Fuel Storage ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 29
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, spot repair less than 3% of total area, carry out mechanical
preparation methods to ISO 8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other
contaminations. Spot repair over 3% of total area carry out abrasive blasting cleaning to ISO 8501-1 Sa21/2
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For Vessels/Chemical
Tanks to (ISO 12944-2): Im1: 50mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
TANKGUARD TYPE III,NONE FC 100 100 600 600 30 * * 16 h 14 d 8h 7d %
5 60 86
TANKGUARD TYPE III,NONE SC 10 100 0 0 30 * * 16 h 14 d 8h 7d 5 0 0
TANKGUARD TYPE III,NONE SC 10 100 0 0 30 * * 16 h 14 d 8h 7d 5 0 0
TANKGUARD TYPE III,NONE FC 100 100 600 600 30 * * 16 h * 8h * 5 60 86
Total 1200
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 33 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 34 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2. Compatibility of the above coating product shall be consulted by Jotun based on the process conditions and internal fluid compostion data as case by case
basis.
3- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 35 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2. Compatibility of the above coating product shall be consulted by Jotun based on the process conditions and internal fluid compostion data as case by case
basis.
3- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 36 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2. Compatibility of the above coating product shall be consulted by Jotun based on the process conditions and internal fluid compostion data as case by case
basis.
3- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 37 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2. Compatibility of the above coating product shall be consulted by Jotun based on the process conditions and internal fluid compostion data as case by case
basis.
3- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 38 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
PAINT SYSTEM UNDER ANALISYS ACCORDING TO OPERATIONAL CONDITIONS - PLEASE CONSULT JOTUN BEFORE APPLICATION.
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 39 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 40 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position D11 - High Pressure Vessels Subjected to Rapid Decompression ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 37
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, spot repair less than 3% of total area, carry out mechanical
preparation methods to ISO 8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other
contaminations. Spot repair over 3% of total area carry out abrasive blasting cleaning to ISO 8501-1 Sa21/2
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For Vessels/Chemical
Tanks to (ISO 12944-2): Im2 / Im4: 50mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
TANKGUARD TYPE III,MUNSELL N9.5 FC 100 100 600 600 30 * * 16 h 14 d 8h 7d %
5 60 86
TANKGUARD TYPE III,MUNSELL N9.5 SC 10 100 0 0 30 * * 16 h 14 d 8h 7d 5 0 0
TANKGUARD TYPE III,MUNSELL N9.5 SC 10 100 0 0 30 * * 16 h 14 d 8h 7d 5 0 0
TANKGUARD TYPE III,MUNSELL N9.5 FC 100 100 600 600 30 * * 16 h * 8h * 5 60 86
Total 1200
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
PAINT SYSTEM UNDER ANALISYS ACCORDING TO OPERATIONAL CONDITIONS - PLEASE CONSULT JOTUN BEFORE APPLICATION.
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 41 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Position E1 - Offshore touch-up painting above the splash zone ISO 12944-2 category N/A
Substrate Carbon Steel Area 100 m² No. 38
Surface Prep. Decontaminated all surface with neutral soap and fresh water, after the surface dry, where necessary, carry out mechanical preparation methods to ISO
8501-1 St3 to ensure the surface is correctly prepared by removing loose residual corrosion, failed coatings and other contaminations.
General recommendations for maximum soluble salts (sample and measured as per ISO 8502-6 and 9) content on a surface are: For exposed areas to
(ISO 12944-2): CX / Im2: 100mg/m2
Product Type Area to Vol. solids Filmthickness (µm) Loss Recoating intervals Thinner Consumption (l)
of paint % % (%) 10°C 23°C 40°C
coat
Dry spec. Wet spec. Min Max Min Max Min Max No. Max Theor. Practical
JOTAMASTIC 87,ALUMINIUM RED TONED FC 100 87 150 172 30 24 h 3 mth 10 h 3 mth 4h 2 mth 17 %
5 17 25
MARATHON 1000 GF,GREY FC 100 98 1000 1020 30 19 h 7d 9h 3d 4h 2d 17 5 102 146
HARDTOP AX,NONE FC 100 63 60 95 30 10 h * 5h * 3h * 10 5 10 14
Total 1210
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 42 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030;Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat;not to build up thickness. FC=Full Coat / SC = Strip Coat.
2 - Finishing Colours
- Grey RAL7035 - White RAL 9016- Green RAL 6032-Yellow RAL 1021- Fire Red RAL 3020- Lilac RAL 4005- Orange RAL 2004 - Dark Grey RAL 7001 - Blue
RAL 5005- Black Ral 9005 - Brown RAL 8002 - Red RAL 3011 - White RAL 9010
3- Finishing Aluminium Colour RAL 9006 only available with Hardtop XP.
4- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 43 of 45
Technical specification
Project MODEC GENERAL OFFSHORE MAINTENANCE BRAZIL Prepared by Gabriel Zanetti - Jotun Brasil Imp.Exp.e Industria de Tintas Ltda.
Rev.10 January 24th 2020
Customer Modec Brazil Approved by Gabriel Zanetti Version 10
Location Date 26-Mar-20
Remarks: Specification in accordance to Modec Topsides Painting and Corrosion Protection Specification 2500-M380-00S1-0030; Rev.0
1- Strong recommended to use the wet gauge during the application to be sure the DFT specified will be achieved // Strong recommended to apply strip coats
between all layers // Strip coat is a reinforcement coat; not to build up thickness. FC=Full Coat / SC = Strip Coat.
2- Minimum peel time: 1 hour at 23 °C
3- It is acceptable a 20% thickness difference higher or lower than specified for each coat.
Page 44 of 45
* please refer to the relevant technical datasheets and AG application guide for recoating and curing conditions
Unless otherwise agreed in writing, all product supplied and technical advice given by us are subject to our standard terms and conditions of sale. In the event that supplies are made and technical
advice is given by one of our associated companies or dealers, then such supplies and technical advice shall be subject to the standard terms of sale of that company, a copy of which is available
upon request. The given data must be considered as guidelines only, the figures in some columns may be rounded. Drying times and paint consumptions may vary depending on actual conditions.
For updated information about our products please refer to our web site at www.jotun.com
Page 45 of 45