Item 11
Item 11
Piezoelectric Accelerometer
FEATURES
High sensitivity
y
]
p
] Differential output
o
] Hermetically welded
c
] Internal case insulation
] Integral cable
w
] Certified for use in potentially explosive
ie
atmospheres
v
] Frequency response:
0.5 Hz to 6 000 Hz
e
] Sensitivity:
R
100 pC/g
DESCRIPTION
The CA 202 accelerometer features a symmetrical monitoring and measurement. The accelerometer is
shear mode polycrystalline measuring element which fitted with an integral cable protected by a stainless
has internal case insulation. The transducer is steel flexible tube welded to the case.
designed for heavy-duty industrial vibration
The information contained in this document may be subject to export control regulations of the European Community, USA or other countries. each
recipient of this document is responsible for ensuring that the transfer or use of any information contained in this document complies with all relevant
export control regulations. ECN N/A.
MECHANICAL DRAWING
∅8.7 nom.
Direction of acceleration to
∅11 ± 0.1
provide a positive signal
22 ± 1
CASE green
Blue
11 ± 0.5
33 ± 1 20 ± 5 5±1
y
6.5 ± 0.2
op
c
30 ± 0.2
40 ± 1
∅11 ± 1
w
30 ± 0.2
ie
40 ± 1 25 max.
v
SPECIFICATIONS
e
GENERAL
R
Input power requirements : None
Signal transmission : 2-pole system insulated from casing, charge output
Signal processor : Charge amplifier
OPERATING
(at +23°C ± 5°C)
Sensitivity (at 120 Hz) : 100 pC/g ± 5%
Dynamic measuring range (random) : 0.01 g to 400 g peak
Overload capacity (spikes) : Up to 500 g peak
Linearity : ±1% between 0.01 g and 20 g peak, ±2% up to 400 g peak
Transverse sensitivity : ≤ 3%
Resonant frequency (mounted) : 20 kHz nominal
Frequency response : ±5% between 0.5 Hz and 6000 Hz (lower cut off frequency is determined by
conditioner used)
+10% between 6 and 8 kHz
Internal insulation resistance : Min. 109 Ω
SPECIFICATIONS (Continued)
Capacitance (nominal)
• Pole to pole : 4 500 pF for transducer + 105 pF/m of cable
• Pole to casing : 10 pF for transducer + 210 pF/m of cable
ENVIRONMENTAL
Temperature range
• Transducer : -55°C to +260°C operation
: -70°C to +280°C survival
• Cable : -55°C to +200°C operation
: -62°C to +250°C survival
Temperature error
• -55°C to +23°C : 0.25%/°C
• +23°C to +200°C : 0.08%/°C
• +200°C to +260°C : 0.25%/°C
Shock acceleration : ≤ 1 000 g peak (half sine wave, 1 ms duration)
y
Explosive atmospheres : Available in Ex version.
p
• EC type examination certificate : LCIE 02 ATEX 6179 X II 1 G (Zones 0, 1, 2) Ex ia IIC T6 to T1
o
For specific parameters of the mode of protection concerned and special conditions for safe use, please refer to the “EC type
c
examination certificate” that is available from Vibro-Meter SA on demand.
ie w
MECHANICAL
Weight
v
• Accelerometer (nominal) : 250 g
e
• Cable : 135 g/m
Cable : 2 pole twisted and shielded
R
Mounting : 4 Allen screws, size M6x35, with M6 spring-lock washers, screw torque 15
Nm.
No need for electrical insulation of mounting surface.
CALIBRATION
Dynamic calibration at factory at 5 g peak and 120 Hz (+23°C). No subsequent calibration necessary.
ORDERING INFORMATION
Ordering Number
Cable length Standard Version Exi Version
3m 144-202-000-203 144-202-000-103
6m 144-202-000-403
11 m 144-202-000-803
p y
MOUNTING ACCESSORIES
o
JB 105 / JB 106 Junction box : See corresponding data sheet
c
MA 133 Thermal insulation kit : See drawing 809-133-000V011
ie w
e v
R
All statements, technical information, drawings, performance rates and descriptions in this document, whilst stated in good faith, are issued for the sole
purpose of giving an approximate indication of the products described in them, and are not binding on Vibro-Meter SA unless expressly agreed in writing.
Before acquiring this product, you must evaluate it and determine if it is suitable for your intended application. Unless otherwise expressly agreed in
writing with Vibro-Meter, you assume all risks and liability associated with its use. Any recommendations and advice given without charge, whilst given in
good faith, are not binding on Vibro-Meter.
Vibro-Meter takes no responsibility for any statements related to the product which are not contained in a current Vibro-Meter publication, nor for any
statements contained in extracts, summaries, translations or any other documents not authored by Vibro-Meter. We reserve the right to alter any part of
this publication without prior notice.
In this publication, a dot (.) is used as the decimal separator and thousands are separated by spaces. Example : 12 345.678 90.
www.vibro-meter.com