www.aqtgenerators.

com

AQT-50 GENERATING SET


“We deliver power, service and solutions in
(TECHNICAL DATA SHEET)
exactly the way you want.”
Output Rating:
Standard Specifications: PRIME: STANDBY:
50 Hz—1500 Rpm 400 V, 3ph
45 kVA 36 kW 50 kVA 40 kW
1- Prime Rating:
60 Hz—1800 Rpm 480 V, 3ph
Unlimited hours usage, with an average
53.1 kVA 42.5 kW 58.7 kVA 46.9 kW
load factor of 80% over each 24 hour peri-
od. 10% overload is available for 1 hour in ENGINE SPECIFICATIONS
every 12 hours operation. Engine Make PERKINS
o overload is permitted on standby power. Engine Model 1103 -33TG1
No. of Cylinders 3 vertical in-line
2- Standby Rating: Cycle 4 Strokes
Limited to 500 hours annual usage, with an Aspiration Turbocharged
average load factor of 80% of the pub- Cooling Method Water cooled
lished standby power rating over each 24 Governing Type Mechanical
hour period. Up to 300 hours of annual Governing Class G2 - ISO 8528 Part 1
usage may be run continuously. Compression Ratio 17.25:1
No overload is permitted on standby pow- Displacement 3.3 L
Bore/Stroke 105 x 127 mm
er.
Dynamic Charging Alternator 65AMP, 12V
3- Engine:
Perkins, including air filters, fuel filters, ALTERNATOR SPECIFICATIONS
Alternator Make Leroy Somer | STAMFORD
oil filter, starting motor and charging alter-
Alternator Model TAL-042-F
nator etc.
Number of Poles 4
4- Alternator Type: Number of Winding Leads 6
brushless AC alternator Type of Bearing Single Bearing
Insulation Class - Temp Rise Cont. H - 125/40̊ ̊C
5- Radiator: Ingress Protection Rating IP 23
50°C, fan protective shroud Excitation System Self Excited
AVR Model R120

Comply with Standards


ISO 3046, BS 5514, DIN 6271, NEMA-MGI, DIN EN, BS 5000, IEC 60034,IEC 60947-2

Powered By: Alternator Operating data


Over speed 2250 rpm
Voltage Regulation + 1%
Harmonic Coefficient THF < 2%
Tel. influence TIF < 50
Cooling air flow 0.10 m3/ Sec

+971 4 547 1703 [email protected] http://www.aqtgenerators.com


Standard Specifications:
Control System:
6– Fuel Tank:
Large back-lit text display Generator/load current monitoring and
protection (kW)
Multiple display languages
Capacity of fuel tank is for 8 hours Breaker contol via fascia buttons
running DSENET expansion compatible Fuel and start outputs, configurable using
can
Built in fuel tank up to 800 kVA Data logging facility 4 configurable DC outputs

Fully configurable via PC using USB


7- Circuit Breaker: communication
4 configurable analogue/digital inputs

Automatically transfers between mains (utility)


Front panel configuration and generator
3 pole LS MCCB Efficient power save mode Increased input and output expansion
capability via dsenet
IP65 rating (with optional gasket) offers
8– Control system alarms: 3 phase generator sensing
increased resistance to water ingress
Accumulated power monitoring (kWh, kVA h,
kVAr h) Digital inputs; Analogue Inputs

• Over and Under Speed


• Low and High Battery Volt.
• Start and Stop Failure
• Over Current
• Under / Over Generator Voltage
DSE4520 MKII
• Low Oil Pressure AUTO START & AUTO MAINS
FAILURE CONTROL
• Emergency stop
• High engine temperature

9– Warranty policy:
Dimensions:
• AQT Generator products has a
warranty for 12 Months or 1000 Length Width Height Fuel Tank Weight
Type
hours whichever occurs first (mm) (mm) (mm) (L) (KG)
against any manufac- OPEN 1950 775 1175 100 850
turing defects
2260 1110 1500 100 1350
• Wearing parts (filters), incorrect
man made operation, mainte-
nance failures are excluded from
the warranty policy

Acoustic Enclosure Specifications:


Acoustic & Weather
Enclosure Type
Proof

Drainage Provision Fuel and Water Drainage


Tested Single Point Lifting
Transportation
Facility & Forklift Pockets
Ingress Protection Rating IP 23

Lifting ISO Standard Lifting


Canopy RAL Color TAL 9010
Base frame RAL Color RAL 9011

Noise Pressure level @ 7m 66db(A) @ 7mt

+971 4 547 1703 [email protected] http://www.aqtgenerators.com


Engine:
Optional configurations:
Engine accessories:
 Heavy-duty air filter
 Coolant heater
 Lubricant oil heater
 Fuel and Water Separator
 Lube oil rotary pump

Alternator And Accessories:


 Leroy somer/stamford
 Anti condensation heater
 PMG + AVR ◇ Double bearing
 Alternator High voltage ______kV
 RTDs for Bearing and winding

Cooling System:
 55 degree Radiator
 Remote Radiator
Control System:
 AMF
 Parallel
Perkins heavy duty high performance industrial type diesel engine.  Practical type in low temperature environment
 Control Screen Heater
COOLING SYSTEM  Remote Annunciators
Total Coolant Capacity (L) 10.2 L  (
Other ComP, DEIF )
Cooling Fan Air Flow 53 m3/ min Circuit Breaker:
Radiator Fan Load 0.4 kW  3/4 poles
Heat Radiation to Room (PRP) 7.0kW
 Fixed/handcart type
Heat Radiation to Room (ESP) 8.0 kW  Electric mechanism
LUBRICATION SYSTEM
Automatic Transfer Switch (ATS):
Oil Filter Type Spin-On Full Flow
Total Oil Capacity 8.3L
 ATS cabinet
Contractor type ATS
Oil Type API-CH-4 or ACEA E5 
 Motorized changeover type ATS
EXHAUST SYSTEM
Muffler Type Industrial Grade Start Battery:
Max. Back Pressure 10 kPa  Nickel-cadmium battery
Exhaust Gas Flow 7.0/7.7 m3(PRP/ESP) / min  Maintenance-free battery
0
 Battery charger and selector switch
Exhaust Gas Temperature < 551C
 Charging current meter
FUEL SYSTEM External Fuel Tank:
Recommended Fuel Class A2 Diesel  Single /double wall fuel tank (500-5000 L)
Fuel Consumption Standby 11.70 L/hr  Fuel Transfer pump

Fuel Consumption 100% PRP 10.80 L/hr


Exhaust Muffler:
Fuel Consumption 75% PRP 8.23 L/hr
Fuel Consumption 50% PRP 5.83 L/hr
 Residential grade
 Critical grade
AIR SYSTEM  Hospital grade
Air Filter Type Dry Element
Available for voltages :
Combustion Air Flow (PRP) 2.9 m3/min  400/230V, 480/277V, 380/220V, 440/254V,
Combustion Air Flow (ESP) 3.1 m3/min 416/240V,220/127V, 208/120V
Max Air Filter Intake Restriction 8 kPa

+971 4 547 1703 [email protected] http://www.aqtgenerators.com


Our Success

We owe our success to our


hardworking, highly skilled and
AQT GENERATORS
committed employees. Our core
focus lies in providing customized
integrated products and services At AQT Generators, we take pride in being a dynamic force in the realm of
with well-established infrastruc-
ture, equipment and manpower to diesel generator sets, offering an extensive range of international brands
support and provide the turn key
solutions for various industries. We
renowned for their reliability and performance. Our commitment to
provide the latest in power genera- excellence is reflected in our partnerships with world-famous engine
tor technology equipment, allow-
ing us to give our customers the manufacturers such as Perkins and Cummins, coupled with top-notch
best product and the best possible
service. alternators from Stamford and Leroy Somer.

Objectives
Our objective is to serve customers
to the utmost by providing them
with the best-in-class electric gen-
erators, reliable door to door deliv-
ery, and after sales service at com-
petitive market prices.

“We continue to build


our solid reputation for
excellence and response,
while delivering reliable
and tailored solutions to
meet the customer's re-
quirements”.

FOLLOW US ON OUR SOCIAL MEDIA ACCOUNTS

CONTACT US in

LinkedIn

Office 204, Al Owais Building,


Port Saeed, Plot No. 388-0,
Dubai, UAE
Call Us: +971 4 547 1703
Email: [email protected]

You might also like