New Product Information

TERUFUSION Syringe Pump Type SS


TE-SS700/TE-SS800

TE-SS700

TE-SS800

〔1〕
TERUFUSION Syringe Pump Type SS
・Specifications
Product name TERUFUSION Syringe Pump Type SS
Model TE-SS700/TE-SS800
Catalogue number TE*SS700N, TE*SS702N, TE*SS800N
Available syringe Sterilized specified syringes for general use and specified pre-filled syringes
Syringe size 5mL,10mL,20mL,30mL,50/60mL
Syringe brand TERUMO or other specified brands
Dose mode mL/h mode
(*: TE-SS800 only) μg/kg/min mode (*)
mg/kg/h mode (*)
Library mode (*)
Flow rate setting range • Setting range
0.01 to 150.00 mL/h
Note that the upper limit of the flow rate can be changed in the following
ranges:
0.01 to 150.00 mL/h (when using syringe of 5 mL)
0.01 to 300.00 mL/h (when using syringe of 10, 20, 30 mL)
0.01 to 1200.00 mL/h (when using syringe of 50/60 mL)
• Step
0.01 mL/h step ( 0.01 to 10.00 mL/h)*
0.10 mL/h step ( 10.00 to 100.00 mL/h)*
1.00 mL/h step ( 100.00 to 1200.00 mL/h)*
*: Step can be used when flow rate is set by the Dial.
(It will be 0.00 mL/h when the power is turned on.)

VTBI setting range


0.10 to 100.00mL (0.10mL step)
100.00 to 9999.00mL (1.00mL step)
When the dose rate is set in mass units, setting in mass units is possible.
(VTBI setting range: 0.01 ng to 9999.99 kg)
“----.--” (Unlimited)
(It will be 0.00 mL/h when the power is turned on.)
VTBI time setting range 1 min to 99 hours 59 mins (1 min step)
“----.--” (Unlimited)
Dose rate setting range 0.01 to 10.00 (0.01 step)
(TE-SS800 only) 10.00 to 100.00 (0.10 step)
100.00 to 999.00 (1.00 step)
(In units of such as μg/kg/min and mg/kg/h etc.)
(It will be 0.00 when the power is turned on.)
Weight setting range
0.1 to 300.0kg (0.1kg step)
(TE-SS800 only)
Dilution setting range 0.01 to 10.00(0.01 step)
(TE-SS800 only) 10.00 to 100.00(0.10 step)
100.00 to 999.00(1.00 step)
(In units of such as mg/mL etc.)
Hands on bolus flow rate 100.00 mL/h (when using syringe of 5mL)
setting range 100.00 to 300.00 mL/h (when using syringe of 10mL, 20mL, 30mL)
100.00 to 1200.00 mL/h (when using syringe of 50/60mL)
(100.00 mL/h step)
Hands free bolus dose 0.01 to 10.00 (0.01 step)
rate setting range 10.00 to 100.00 (0.10 step)
100.00 to 999.00 (1.00 step)
(In units of such as mL and mg/kg etc.)
Hands free bolus dose
1 sec to 60 mins 00 sec (1 sec step)
time setting range
Volume delivered display 0.00 to 10.00mL (0.01mL step)
range 10.00 to 100.00mL (0.10mL step)
100.00 to 9999.00mL (1.00mL step)
When the dose rate is set in mass units, the volume is expressed in mass units.
(VTBI setting range: 0.01 ng to 9999.99 kg)
(It will be 0.00 mL/h when the power is turned on.)
〔2〕
TERUFUSION Syringe Pump Type SS
・Specifications
Flow rate Machine
Within ±1% (flow rate ≥ 1.00 mL/h)
accuracy accuracy
Accuracy Within ±3%
including (The hourly precision after one hour has passed since the start of infusion at a
syringe constant flow rate of 1.00 mL/h or more according to IEC 60601-2-24 standard.)
Occlusion detection 10 to 120kPa (set value)
pressure The occlusion detection pressure can be set in 10 levels.
Purge flow rate Approx. 150 mL/h (when using syringe of 5mL)
Approx. 300 mL/h (when using syringe of 10mL)
Approx. 400 mL/h (when using syringe of 20mL)
Approx. 500 mL/h (when using syringe of 30mL)
Approx. 1200 mL/h (when using syringe of 50/60mL)
Alarms Occlusion alarm, Pressure alarm*1, Nearly Empty alarm, Clutch Displacement
alarm, Syringe Barrel Detection alarm, Syringe Displacement alarm, Plunger
Displacement alarm, Battery alarm, Re-alarm, Start Reminder, No Flow
Rate alarm, No VTBI alarm*2, Flow Rate/VTBI Volume Judgment alarm*2,
Completion alarm*2, Link Interruption alarm*1
*1: TE-SS800 only
*2: Only if the VTBI setting function is enabled (Default: disabled)
Safety functions ・Remaining volume detection position function
・Occlusion detection pressure select function
・Bolus reduction function
・Flow rate range setting function A (Soft limits)
・Flow rate range setting function B (Hard limits)
・Key lock function
Available Functions ・Syringe installation guidance function ・Syringe brand display function ・Syringe type
switch function ・ ・VTBI setting function ・VTBI time setting function ・Purge/bolus buzzer
sound function ・Volume delivered clear function ・Standby function ・Standby duration time
select function ・Buzzer volume select function ・Switch operation buzzer sound function ・
Stop transition buzzer sound function ・LCD brightness select function ・Maintenance timer
function ・Date and time setting function ・External communication function (RS-232C)(TE-
SS702 only) ・Free message function (TE-SS702 and 800 only) ・External communication
function (infraredcommunication (IrDA))(TE-SS800 only) ・External communication
function (wireless LAN)(TE-SS800 only) ・Nurse call function(TE-SS702 only) ・History
function ・AC power detector function ・AC power detector buzzer sound function ・Keep
Vein Open function ・Keep Vein Open flow rate select function ・During-start volume
delivered clear function ・During-start flow rate/dosage rate change function ・Alarm
melody select function ・Setting step 100 times function ・Hands on bolus function ・Hands
free bolus function ・Shortcut call function ・Night mode function ・Power OFF buzzer
sound function ・Dose mode select function(TE-SS800 only) ・Patient information display
function(TE-SS800 only) ・Intermittent dose function(TE-SS800 only) ・Multi-step dose
function(TE-SS800 only) ・Delayed Start dose function(TE-SS800 only) ・Link function
(Switch function A, B)(TE-SS800 only) ・Come and See ME function(TE-SS800 only) ・
Volume delivered unit select function(TE-SS800 only) ・Micro notation select function(TE-
SS800 only)

〔3〕
TERUFUSION Syringe Pump Type SS
・Specifications
Use conditions Ambient temperature: 5 to 40°C
Relative humidity: 20 to 90%RH (non-condensing)
Storage conditions Ambient temperature: -20 to 45°C
Relative humidity: 10 to 95%RH (non-condensing)
Transport conditions Ambient temperature -20 to 60°C,
Relative humidity 10 to 95%RH (non-condensing)
Power supply AC100 to 240V, 50 to 60Hz
Internal battery (lithium ion battery)
• Continuous use period
Approx. 12 hours (applies when solution is delivered continuously at 5 mL/h in ambient
temperature of 25°C with new fully charged battery)
• Charging time:
≥8 hours (when charged with AC power supply with the power turned off)
Power consumption 24VA
Classification Class I equipment and internally powered equipment, type CF applied part,
Continuous Operation, IP24
Wireless LAN Hereby, TERUMO CORPORATION declares that this TERUFUSION
Syringe Pump Type SS is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC.
• Transmit frequency or frequency band: 2412 – 2472 MHz
• Type of modulation and frequency characteristics:
• Differential Binary Phase Shift Keying: DBPSK
• Differential Quadrature Phase Shift Keying: DQPSK
• Direct Sequence Spread Spectrum: DSSS
• Complementary code keying: CCK
• Effective radiated power: 10.7 dBm

Dimensions Without external communication (RS-232C):


381 mm (W)*3 x 120 mm (H)*3 x 112 mm (D)*4
With external communication (RS-232C):
381 mm (W)*3 x 120 mm (H)*3 x 131 mm (D)*4
*3: Excluding protrusions,
*4: Excluding protrusions, pole clamp and moving range

Unit Weight Approx. 2.0 kg


Standard accessories AC power cable, pole clamp (Screw type), instruction manual

• This product is compatible with EMC (electromagnetic compatibility) standard IEC 60601-1-2:2001 Amd.
1:2004 (CISPR group classification and class classification are Group 1 and Class B).
It is also compatible with the EMC level required by IEC 60601-2-24:1998.

• Conformity standard
IEC 60601-1:1988,Amd. 1:1991,Amd. 2:1995
IEC 60601-1-1:2000
IEC 60601-1-2:2001,Amd. 1:2004
IEC 60601-1-6:2006
IEC 60601-1-8:2006
IEC 60601-2-24:1998
MDD (Medical Device Directive) 93/42/EEC (Class IIb)

TERUMO CORPORATION
44-1, 2-Chome, Hatagaya, Shibuya-Ku, Tokyo 151-0072, Japan
〔4〕