IN CASE OF SUBSTITUTION OF ELECTRIC MOTOR OR COMPRESSOR IS CHANGED OF LOCATION, IT IS

IMPERATIVE TO CHECK THE ROTATION OF AIREND AS ABOVE DESCRIBED BEFORE RE-STARTING


THE COMPRESSOR

Already during this phase, it is compulsory to follow very carefully the SAFETY INFORMATION on the usage of the
compressor.

* If the technician fill up the (R.C.R.) registration and commissioning report copy of which you can find at page 20 of
this manual, the possibility of a safer and more efficient operation of compressor unit is increased and eventual warranty
communication and decision will be more prompt.

TECHNICAL DATA

Description Unit KB1508WS


1 Working pressure bar 6.5 – 8
2 Max. working pressure bar 8
3 Min. working pressure bar 6.5
4 Air capacity(ISO.1217) m3/min 2.16
5 Air connection (inch) G3/4″
6 Oil capacity L 12
7 Safety valve pressure setting bar 10
8 Noise level (1m distance) dB(A) 69±3
9 Cooling water requirement — City water
10 Cooling water capacity ( m3/h ) 1.5
11 Water pressure ( Mpa ) 0.3~0.5
12 Cooling water temperature (℃) ≤32
13 Cooling water pipe connections (inch) G 1/2″
14 Dimensions:L × W × H (mm) 1000 × 670 × 1000
15 Weight (kg) 410

Adekom - Instruction and maintenance manual -


13
ELECTRONIC CONTROL PANEL

Power LED

E-stop Button

Power LED This LED will light when the machine connects to the power.

E-stop Button Press this button only when the compressor has malfunction
and the unit needs to be stopped in emergency.
Warning: Don’t use this button to stop the compressor during normal operation.

CONTROLLER DISPLAY ON CONTROLLER PANEL , THERE ARE 7 KEYS:

《 》《 》《 》《 》《 》《 》《 》, functions are as follows:

《 》 Start button for compressor

《 》 Stop button for compressor

《 》 Enter button for set value or Load/unload button

《 》 Page down or Set bit –1

《 》 Page up or Set bit +1

《 》 Move button or Enter button for menu

《 》 Exit or Reset

You can change the operating parameters by pressing《 》only when the unit stopped; otherwise, you can only view

the parameters. After changing the parameters, you should press 《 》to confirm. You can also press《 》to exit
without changing parameters.

Adekom - Instruction and maintenance manual -


14
Warning

Warning signal will be displayed when the following error(s) have been found; however, the machine will
continue to run with the corresponding error(s) shown on the controller display. The LED background will
flash continuously with b sound. After the error(s) have been fixed, the displayed will return to normal.

Item Error Display Definition of error


1 Air Filter Air filter blocked
2 Oil Separator Oil separator blocked
3 Oil Filter Oil filter blocked
4 A-F Overtime Air filter used over specified period
5 O-S Overtime Oil separator used over specified period
6 O-F Overtime Oil filter used over specified period
7 Lube Overtime Lubricant used over specified period
8 Grease Overtime Grease used over specified period
9 Belt Overtime V-belt used over specified period
10 Temp. High Discharge temperature too high (pre-warning)
11 Communication Communication error

Tripped

Warning signal will be displayed when the following error(s) have been found and the machine will stop
running with the corresponding error(s) shown on the controller display. The LED background will flash
continuously with b sound. After the error(s) have been fixed, the displayed will return to normal but the
sound will not go out until you press《F2》to re-set it.

Item Error Display Definition of error


1 Pressure High High pressure tripped
2 Temp. High High temperature tripped
3 Host Overload Main motor overloaded
4 Fan Overload Fan motor overloaded
5 Phase Imbalance Phase imbalance
6 Phase Sequence Phase sequence error
7 Non-Phase More than one phase current is 0
8 Temp. Sensor Temperature transducer fault
9 Pres. Sensor Pressure transducer fault
10 Run Overtime Machine running over specified period

LIST OF SPARE PARTS FOR ROUTINE MAINTENANCE


Compressor Model : KB1508WS
Part number Description
09070060 Air/oil separator element
09020040 Air filter element
09040020 Oil filter
03080010 Kit minimum pressure valve
03020029 Kit thermostatic valve
03060001 Solenoid valve
19030099 V-belt
14010006 Compressor oil

Adekom - Instruction and maintenance manual -


15