1 DiaSys 2.50
1 DiaSys 2.50
DiaSys 2.xx
30.06.2010 Pfad\Dateiname 1
Dialog system DiaSys 2.xx
Table of contents
01. Purpose 15. Extras/Settings
02. Terms and definitions 16. Protocol/Changes
03. Preconditions 17. Additional functions with ECU-7
04. Pre Check 18. Unit type ADEC
05. Starting DiaSys 19. Unit description
06. Unit description 20. Connection to ECU-7
07. Connection to CAN bus 21. Central database (CDB)
08. Selecting unit 22. Connection to CDB
09. Recording Measuring Points 23. Data transfer
10. Editing parameters 24. Special parameters
11. Extras/Export 25. Extras/Display engine number
12. Extras/Hardware key 26. Protocols
13. Extras/Start-up<>Initial value 27. Erasing and resetting governor data
14. Extras/Selecting language 28. ECU-7 in SAM project
30.06.2010 Pfad\Dateiname 2
Dialog system DiaSys 2.xx
Purpose
The DiaSys software is required to communicate with MTU components such as ECU-7,
SAM, AKC and ignition system. Main functions of the DiaSys software:
Recording data
Note: This PowerPoint presentation mainly contains information regarding the use of
DiaSys in connection with engine governors. The functions described require a level 1B
(customer service/distributors) or level 1C (test stand) dongle.
30.06.2010 Pfad\Dateiname 3
Dialog system DiaSys 2.xx
Terms and definitions (1)
ADEC Advanced Diesel Engine Controller
This term is not used in the document at hand. Instead
"ECU-7" is used.
DILA Diagnostiklampe
30.06.2010 Pfad\Dateiname 4
Dialog system DiaSys 2.50
Terms and definitions (2)
FSW Functional software. Governor operating software.
DiaSys cannot be set to online mode unless FSW has
been downloaded to the governor.
MPS Engine parameter set. These are engine governor
operating parameters.
Local database Files or databases relating to an engine number which
have been stored locally on the PC. This data can be
intended for the governor or the central database.
Central database Data (FSW and MPS) for each engine number is stored
in a central database in Friedrichshafen. This database is
also referred to as "governor database".
CCS Compatibility Check System. Allows checking of
interactions between objects (software and/or hardware)
and visualization of object characteristics.
Hardware key (dongle) Contains various user-specific information and has an
expiry date. Starting three months prior to that date, a
reminder to this effect is displayed after each DiaSys
start-up.
30.06.2010 Pfad\Dateiname 5
Dialog system DiaSys 2.xx
Terms and definitions (3)
Online mode The PC's serial / CAN interface is
connected to the governor and a
data connection with the governor
has been established.
30.06.2010 Pfad\Dateiname 6
Dialog system DiaSys 2.xx
Preparing CF card for SAM (1)
1. Preparing card:
a) Format CF card (select card and format by right-clicking (FAT)
b) Create "New folder" on CF
c) Re-name this folder to BDM
d) Copy the BDM….exe file into the BDM folder
e) Double-click on BDM_4000….exe IMPORTANT!!
2. Inserting card:
a) Switch SAM power supply off (remove fuse)
b) Insert CF card
c) Switch SAM power supply on
d) Download starts automatically
30.06.2010 Pfad\Dateiname 7
Dialog system DiaSys 2.xx
Preparing CF card for SAM (2)
Open My Computer
30.06.2010 Pfad\Dateiname 8
Dialog system DiaSys 2.xx
Preparing CF card for SAM (3)
30.06.2010 Pfad\Dateiname 9
Dialog system DiaSys 2.xx
Preparing CF card for SAM (4)
Go after formatting on the CF
Card and provide a new file.
Importantly: It must be called
BDM (largely written).
30.06.2010 Pfad\Dateiname 10
Dialog system DiaSys 2.xx
Preparing CF card for SAM (5)
After the double click the file will
unpacked itself
30.06.2010 Pfad\Dateiname 11
Dialog system DiaSys 2.xx
Prerequisite for Hardware and Software
DIASYS 2.xx
Dongle (level 1b, 1c)
Notebook with installed DIASYS 2.xx software
30.06.2010 Pfad\Dateiname 12
Dialog system DiaSys 2.xx
Pre Check (1)
1. Set CAN card to tinCAN or CAN-to-USB:
a) START Settings Control Panel IXXAT (double-click)
30.06.2010 Pfad\Dateiname 14
Dialog system DiaSys 2.xx
Starting DiaSys (1)
Starting
DIASYS 2.50:
Double-click on
DIASYS icon
30.06.2010 Pfad\Dateiname 15
Dialog system DiaSys 2.xx
Starting DiaSys (2)
The DIASYS
window opens.
Start program by
clicking "OK"
30.06.2010 Pfad\Dateiname 16
Dialog system DiaSys 2.xx
Starting DiaSys (3)
Note warning and
confirm by
clicking "OK".
30.06.2010 Pfad\Dateiname 17
Dialog system DiaSys 2.xx
Starting DiaSys (4)
The content of
this window
depends on the
dongle level.
Level 0 Customer
Level 1A OEM
Level 1B Service
30.06.2010 Pfad\Dateiname 18
Dialog system DiaSys 2.xx
Starting DiaSys (5)
The content of
this window
depends on the
dongle level.
In our case
(dongle level 1b)
we select the
Service button.
30.06.2010 Pfad\Dateiname 19
Dialog system DiaSys 2.xx
Starting DiaSys (6)
In the next window
the desired unit
can be selected.
Note:
Clicking on the
camera button opens
a window with a
picture of the
corresponding unit.
30.06.2010 Pfad\Dateiname 20
Dialog system DiaSys 2.xx
Starting DiaSys (6)
To establish a
connection with SAM
select the
MCS-5/RCS-5/SAM
button.
To establish a
connection with ECU-
7 select the
30.06.2010 Pfad\Dateiname 21
Dialog system DiaSys 2.xx
Unit description (1)
As a first step the
unit description
must be created!
To do this click on
30.06.2010 Pfad\Dateiname 22
Dialog system DiaSys 2.xx
Unit description (2)
In the next window
the order number /
plant number must be
entered!
In addition an index
number can be
assigned.
Click
Create
to continue.
30.06.2010 Pfad\Dateiname 23
Dialog system DiaSys 2.xx
Unit description (3)
In the next
window select
the
Read unit
description…
description…
button.
30.06.2010 Pfad\Dateiname 24
Dialog system DiaSys 2.xx
Unit description (4)
In order to read the
unit description
DiaSys requires the
following file:
DIASYS.dat
(This file is usually
located in the BDM
folder or in the
project folder:
C:\DIASYS\CAN\Projektxyz\
diasys.dat
30.06.2010 Pfad\Dateiname 25
Dialog system DiaSys 2.xx
Unit description (5)
After successful
readout the following
window is displayed.
Confirm by clicking
"OK".
Note: Stating the
engine number is not
required for the SAM
(contrary to ECU-7).
30.06.2010 Pfad\Dateiname 26
Dialog system DiaSys 2.xx
Unit description (6)
30.06.2010 Pfad\Dateiname 27
Dialog system DiaSys 2.xx
Unit description (7)
30.06.2010 Pfad\Dateiname 28
Dialog system DiaSys 2.xx
Establish Data Link to CAN bus (1)
In order to establish
an online connection
click the button:
30.06.2010 Pfad\Dateiname 29
Dialog system DiaSys 2.xx
Establish Data Link to CAN bus (2)
To establish a data
circuit select the field
bus (FB).
Choose FB (fieldbus)
Confirm by clicking
"OK"!
30.06.2010 Pfad\Dateiname 30
Dialog system DiaSys 2.xx
Establish Data Link to CAN bus (3)
Once connection to
the CAN bus has been
established, the
display changes from
OFFLINE to ONLINE!
30.06.2010 Pfad\Dateiname 31
Dialog system DiaSys 2.xx
Selecting unit (1)
In the next step you
need to select the unit
with which you want
to exchange data. To
do this click on the
button.
Select unit…
30.06.2010 Pfad\Dateiname 32
Dialog system DiaSys 2.xx
Selecting unit (2)
Open the tree structure
and select the relevant
unit (here: SAM).
30.06.2010 Pfad\Dateiname 33
Dialog system DiaSys 2.xx
Recording measuring points (1)
To record measuring points select the
"Start data recording" button. A dialog
window will be displayed in which
individual or all measuring points can
be selected for recording.
30.06.2010 Pfad\Dateiname 35
Dialog system DiaSys 2.xx
Recording measuring points (3)
30.06.2010 Pfad\Dateiname 36
Dialog system DiaSys 2.xx
Recording measuring points (4)
The measured value list is displayed
in the background together with a
window for the selection of the
measuring points (graphic). Confirm by
clicking "OK" if you wish to see the
graphic display; otherwise click
"Cancel".
30.06.2010 Pfad\Dateiname 37
Dialog system DiaSys 2.xx
Recording measuring points (5)
30.06.2010 Pfad\Dateiname 38
Dialog system DiaSys 2.xx
Recording measuring points (6)
30.06.2010 Pfad\Dateiname 39
Dialog system DiaSys 2.xx
Recording measuring points (7)
30.06.2010 Pfad\Dateiname 40
Dialog system DiaSys 2.xx
Recording measuring points (8)
30.06.2010 Pfad\Dateiname 41
Dialog system DiaSys 2.xx
Recording measuring points (9)
30.06.2010 Pfad\Dateiname 42
Dialog system DiaSys 2.xx
Recording measuring points (10)
30.06.2010 Pfad\Dateiname 43
Dialog system DiaSys 2.xx
Recording measuring points (11)
30.06.2010 Pfad\Dateiname 44
Dialog system DiaSys 2.xx
Recording measuring points (12)
30.06.2010 Pfad\Dateiname 45
Dialog system DiaSys 2.xx
Recording measuring points (13)
30.06.2010 Pfad\Dateiname 46
Dialog system DiaSys 2.xx
Modify Single Parameters (1)
Modify single
PARAMETERS 1D
30.06.2010 Pfad\Dateiname 47
Dialog system DiaSys 2.xx
Modify Single Parameters (2)
30.06.2010 Pfad\Dateiname 48
Dialog system DiaSys 2.xx
Modify Single Parameters (3)
30.06.2010 Pfad\Dateiname 49
Dialog system DiaSys 2.xx
Modify Single Parameters (4)
To facilitate searching /
selection DIASYS version 2.50
and upwards offers a new
feature to select parameters
using a filter. Filtering can be
done based on
Filter selection
parameter number
parameter
unit
Selecting a filter allows quick
finding of the parameters
required (see following
examples).
30.06.2010 Pfad\Dateiname 50
Dialog system DiaSys 2.xx
Modify Single Parameters (5)
30.06.2010 Pfad\Dateiname 51
Dialog system DiaSys 2.xx
Modify Single Parameters (6)
Filtering by parameter name
30.06.2010 Pfad\Dateiname 52
Dialog system DiaSys 2.xx
Modify Single Parameters (7)
30.06.2010 Pfad\Dateiname 53
Dialog system DiaSys 2.xx
Modify Single Parameters (8)
Changing parameters:
Change the desired value in
the PC value column and
transfer to SAM by clicking
SEND (F11)
Contrary to previous
versions it is now possible to
send the parameter value
directly to the unit (automatic
takeover as startup and
active value).
30.06.2010 Pfad\Dateiname 54
Dialog system DiaSys 2.xx
Modify Single Parameters (9)
Take over the parameter by clicking
Send. To take over the parameter in all
memories the box in the upper left-hand
corner (Take over to all memories when
If this box is ticked, the value is sending) must be ticked.
taken over to all memories when
sent
30.06.2010 Pfad\Dateiname 56
Dialog system DiaSys 2.xx
EXTRAS/EXPORT (2)
30.06.2010 Pfad\Dateiname 57
Dialog system DiaSys 2.xx
EXTRAS/HW-Key Info
Clicking the button
Hardware key Info
provides information on
User
Expiry date
Access level and
Access rights
30.06.2010 Pfad\Dateiname 58
Dialog system DiaSys 2.xx
EXPORT/Start-up<>Initial value
30.06.2010 Pfad\Dateiname 59
Dialog system DiaSys 2.xx
EXTRAS/Selecting language
30.06.2010 Pfad\Dateiname 60
Dialog system DiaSys 2.xx
EXTRAS/Settings
This menu allows you to
activate/deactivate several settings,
e.g. whether or not the unit of the
parameter is displayed in the
graphic measured display.
30.06.2010 Pfad\Dateiname 62
Dialog system DiaSys 2.xx
PROTOCOL/Changes (2)
Change protocol (example)
30.06.2010 Pfad\Dateiname 63
Dialog system DiaSys 2.xx
Additional functions for ECU-7
30.06.2010 Pfad\Dateiname 64
Dialog system DiaSys 2.xx
Unit type ADEC
Following selection of the user group (customer service or test stand) the
unit type must be selected. Click on
ECU-
ECU-7 Gas
ADEC
30.06.2010 Pfad\Dateiname 65
Dialog system DiaSys 2.xx
Unit description (1)
30.06.2010 Pfad\Dateiname 66
Dialog system DiaSys 2.xx
Unit description (2)
30.06.2010 Pfad\Dateiname 67
Dialog system DiaSys 2.xx
Erasing governor data (1)
DIASYS has a function for erasing and
reloading governor data. To do this the
first step is to establish an OFFLINE
connection.
Disconnect data connection to unit.
30.06.2010 Pfad\Dateiname 68
Dialog system DiaSys 2.xx
Erasing governor data (2)
Once the governor is in OFFLINE mode
click on "Load governor…".
30.06.2010 Pfad\Dateiname 69
Dialog system DiaSys 2.xx
Erasing governor data (3)
Then click "Erase governor data and
re-load governor" and confirm the
process by entering the serial number in
the next window.
30.06.2010 Pfad\Dateiname 70
Dialog system DiaSys 2.xx
Reloading governor data (1)
Erasing and reloading are carried out automatically. The loading progress is displayed
in a separate window.
30.06.2010 Pfad\Dateiname 71
Dialog system DiaSys 2.xx
Reloading governor data (2)
Once loading has been completed a
window is displayed stating that all data
has been loaded. Confirm by clicking
"OK".
30.06.2010 Pfad\Dateiname 72
Dialog system DiaSys 2.xx
Hardware reset
Hardware reset
For service technicians
Note:
If a SAM with Field Data Handling (FDH) is connected, the governor
retrieves the data from the SAM following a hardware reset.
30.06.2010 Pfad\Dateiname 73
Dialog system DiaSys 2.xx
Emergency operation
This dialog is activated The governor data can now
automatically if a fault be loaded via the
occurs during "Online "Emergency operation,
loading" (e.g. connection governor loading" option.
interrupted) Since it may no longer be
possible to establish an
online connection, the
governor data is loaded
offline.
Note:
When governor data is loaded via the emergency operation function the data is loaded
offline but data such as operating hours is not lost.
30.06.2010 Pfad\Dateiname 74
Dialog system DiaSys 2.xx
Connection to ECU-7 (1)
30.06.2010 Pfad\Dateiname 75
Dialog system DiaSys 2.xx
Connection to ECU-7 (2)
30.06.2010 Pfad\Dateiname 76
Dialog system DiaSys 2.xx
Central database
Engine governor
ECU-7
Receive parameter set from
central database
30.06.2010 Pfad\Dateiname 77
Dialog system DiaSys 2.xx
Connection to CDB
Note: OEM customers do not use these transfer methods but proceeds as
described below (Data transfer via files…)
30.06.2010 Pfad\Dateiname 78
Dialog system DiaSys 2.xx
Data transfer (1)
If data cannot be transferred via LAN or
MODEM, engine data sets can also be
transferred as files. OEM cusomers are
using this method, however there is a
high risk of data sets being used in the
field which are not up-to-date.
30.06.2010 Pfad\Dateiname 79
Dialog system DiaSys 2.xx
Data transfer (2)
30.06.2010 Pfad\Dateiname 80
Dialog system DiaSys 2.xx
Data transfer (3)
Exporting data:
30.06.2010 Pfad\Dateiname 81
Dialog system DiaSys 2.xx
Data transfer (4)
Importing data:
30.06.2010 Pfad\Dateiname 82
Dialog system DiaSys 2.xx
Special parameters (1)
Editing input and output settings:
30.06.2010 Pfad\Dateiname 83
Dialog system DiaSys 2.xx
Special parameters (2)
Editing alarm parameters: The alarm parameters are set using this
menu option, e.g. whether a fault causes a
yellow or red alarm
Note:
Cannot be changed with level 1B
30.06.2010 Pfad\Dateiname 84
Dialog system DiaSys 2.xx
Special parameters (3)
Editing protection/monitoring parameters:
30.06.2010 Pfad\Dateiname 85
Dialog system DiaSys 2.xx
EXTRAS/Show Engine Number
Display engine number:
Option to check the engine number
30.06.2010 Pfad\Dateiname 86
Dialog system DiaSys 2.xx
EXTRAS/Trip-Data (1)
Recording with defined measuring points which cannot be changed by the user
30.06.2010 Pfad\Dateiname 87
Dialog system DiaSys 2.xx
EXTRAS/Trip-Data (2)
30.06.2010 Pfad\Dateiname 88
Dialog system DiaSys 2.xx
Protocols (1)
Fault protocol:
List of faults with time stamp (time
stamp not yet available)
30.06.2010 Pfad\Dateiname 89
Dialog system DiaSys 2.xx
Protocols (2)
Fault protocol:
The second column (+) can be used to
change the order (ascending/descending).
30.06.2010 Pfad\Dateiname 90
Dialog system DiaSys 2.xx
Protocols (3)
Exporting fault protocol (EXCEL):
Select the highlighted button and
click "OK" in the next window to
confirm.
30.06.2010 Pfad\Dateiname 91
Dialog system DiaSys 2.xx
Protocols (4)
30.06.2010 Pfad\Dateiname 92
Dialog system DiaSys 2.50
Protocols (5)
Message that the EXCEL file has successfully been created (including information on
file path and name)
30.06.2010 Pfad\Dateiname 93
Dialog system DiaSys 2.xx
ECU-7 in SAM project (1)
To avoid having to select several unit
Starting point: types DIASYS provides a function to
integrate the ECU-7 in the SAM project.
Select the
"Edit unit description…"
button
30.06.2010 Pfad\Dateiname 94
Dialog system DiaSys 2.xx
ECU-7 in SAM project (2)
Select the desired unit description.
starting situation: Edit the unit description (new engine
number).
Select the governor type (e.g.
ECU-7 ADEC Gas)
30.06.2010 Pfad\Dateiname 95
Dialog system DiaSys 2.xx
ECU-7 in SAM project (3)
Allocate to the existing bus
(engine number and field bus).
Ausgangslage:
30.06.2010 Pfad\Dateiname 96
Dialog system DiaSys 2.xx
ECU-7 in SAM project (4)
30.06.2010 Pfad\Dateiname 97
Dialog system DiaSys 2.xx
ECU-7 in SAM project (5)
30.06.2010 Pfad\Dateiname 98
Dialog system DiaSys 2.xx
Data feedback (1)
"Voluntary" data feedback
User selects all data sets that Time X
are to be included in the unlimited
feedback
Local Central
database database
Automatic, forced feedback
Engine No. 1
Data sets that are to be Time X
Engine No. 2 included in the feedback limited to 16
Engine No. 3 are selected by DiaSys. minutes
No selection by the user.
30.06.2010 Pfad\Dateiname 99
Dialog system DiaSys 2.xx
Data feedback (2)
If the local database contains data sets which have not yet been reported back and a new data
set is to be downloaded from the central database, data feedback must be carried out first.
This data feedback can be "voluntary", i.e. the data sets are selected by the user, or it can be
forced automatically by DiaSys.
If the user decides to report back all data sets now that have not been reported back previously
this may be very time-consuming.
If the user decides not to report back any data sets an automatic forced feedback is carried out.
This function times out after 16 minutes.
4 minutes for ADEC data sets.
If the local database contains more data sets than can be reported back in this time (max. 4
ADEC data sets in 16 minutes), these are reported back next time the connection is established.
If the user decides not to report back all data sets designed to be reported back (partial
selection), the data sets selected by the user will be reported back first. Depending on the
remaining time X a forced feedback will be carried out nevertheless. The maximum total time for
this function is also 16 minutes.
"Voluntary selection"
Click OK
Select the correct file with the cross and click Copy