Profibus - Architecture, Types, Differences & Its Applications
Profibus - Architecture, Types, Differences & Its Applications
between the controllers or the control system and the field sensors. This network uses the OSI model to Loop Antenn
Radiation Pa
ensure that devices from various vendors can interact together effectively & easily.
Brent Kung A
Advantages,
Applications
Inverting Sum
Working, Der
Its Applicatio
Active Band
Frequency R
Advantages &
Magnetic Sta
Wiring, Vs Co
https://www.elprocus.com/profibus/ 1/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
Applications
Profibus was first promoted by the German department of education and research. After that used by Bode Plot : T
Advantages,
Siemens in the year 1989 in collaboration with different automation equipment manufacturers. At present, Applications
above 11.5 millions PROFIBUS based devices are used in process automation systems.
So this article discusses an overview of Profibus, architecture working & its applications.
PROJECTS
8051 Project
The term “Profibus” stands for “Process Field Bus” and it is the most widely used industrial control network
Arduino Proje
worldwide for industrial process control, motion control, automation, and safety networks. This network is
ARM Project
supported by above 1400 equipment vendors worldwide. In the OSI model, this control network provides
Communicat
services at different layers like layer1, layer2 & layer7.
DTMF Projec
ECE Projects
EEE Projects
https://www.elprocus.com/profibus/ 2/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
EIE Projects
Electrical Min
Electrical Pro
Electronics P
Embedded P
GSM Project
Home Autom
IOT Projects
Profibus Device LabView Proj
Matlab Proje
The two most frequently used Profibus versions are Profibus-DP & Profibus-PA.
Microcontroll
The devices used by Profibus are masters & slaves. The main function of Master devices is to control the Mini Project C
bus once they have the right to access the bus, so they may transmit messages without any remote Mini Project I
request known as active stations. PIC Projects
Power Electr
Raspberry Pi
RFID Project
Robotics Pro
Sensor Proje
Solar Project
VLSI Projects
https://www.elprocus.com/profibus/ 3/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
Wireless Proj
Zigbee Proje
Slave devices are normally peripheral devices like sensors, transmitters & actuators which may allow
received messages at the master’s request, send messages to that master which is known as passive
stations.
Profibus Types
The Profibus is available in three compatible versions Profibus-DP, Profibus-PA & Profibus-FMS.
https://www.elprocus.com/profibus/ 4/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
Ad removed. Details
Profibus-DP
PROFIBUS DP is one of the most frequently used variants of Profibus so-called the standard PROFIBUS.
The main benefits of this variant are; plug & play, data transfer can be done very fastly & most frequently
used in production environments globally.
This variant is particularly designed for high-speed data communication in between automation control
systems & distributed I/O at the level of the device. The central controllers Like PCs or PLCs interact with
their distributed field devices through a high-speed serial link. So, most of this data communication through
the distributed devices can be carried out cyclically.
https://www.elprocus.com/profibus/ 5/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
Profibus DP
In addition to executing cyclic functions, acyclic communication functions are obtainable especially for
intelligent field devices by allowing configuration, diagnostics, and handling alarm. Profibus DP supports
up to 126 nodes over a bus, permits several masters which are available on the network only if all slaves
are connected with a single master. PROFIBUS DP includes three different versions DP-V0, DP-V1& DP-
V2.
https://www.elprocus.com/profibus/ 6/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
Ad removed. Details
DPV0 version is mainly used in simple & remote equipment. The features of the DPV0 version mainly
include; cyclic data that can be exchanged between masters & slaves, Diagnostics and GSD, or general
station description.
DPV1 version is mainly used whenever an exchange of asynchronous data is required. The main features
of the DPV1 version include; acyclic data exchange can be done between master & slave, alarm
management, combination with FDT & EDDL, and functional blocks.
DPV2 version is mainly used to execute different functions with high performance like exchange of data in
broadcast and synchronous communication. The features of this DPV2 version mainly include; time mode
of cyclic is deterministic, data exchange can be done by using the slave to slave communication, upload &
download redundancy, HART protocol implementation over DP, etc.
Profibus-PA
https://www.elprocus.com/profibus/ 7/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
Profibus PA is mainly designed for an automation process. So it allows different sensors as well as
actuators connected on a single common bus line even in intrinsically secure regions. It allows power &
data communication on the bus through two-wire technology based on the (international standard (IEC)
1158-2.
Profibus-PA
PROFIBUS PA improves & replaces conventional systems within process automation like 4-20 mA and
HART. As compared to PROFIBUS DP, the power supply & data in Profibus PA are transmitted on similar
two wires. In addition, both the PROFIBUS DP & PA are the same in terms of use and protocol.
Profibus-FMS
The Profibus FMS or PROFIBUS field bus message specification is a general-purpose solution, especially
for communication tasks at the cell level. This was mainly designed to interact between PLCs & PCs by
transmitting complex data between them.
https://www.elprocus.com/profibus/ 8/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
Profibus-FMS
This was not suitable for low-complex messages otherwise communication on a more complicated and
wider network. Powerful FMS services provide huge flexibility and also be used for complex & wide
communication tasks. At present, PROFIBUS FMS is still used by more operators.
Profibus Specifications
The specifications of Profibus DP & Profibus PA include the following.
The size of data transfer mainly depends on the type of device like the input is up to 246 bytes and
output is up to 246 bytes.
The device identification can be done based on the particular ID number for every device.
The physical layer of Profibus PA is IEC61158-2.
The topology used is a trunk with branching.
The length of the cable is 1900meters.
The number of devices used is 32.
Bus power is up to 0/5A for every segment.
The rate of transmission is 31.25 kbits/sec.
Profibus Architecture
PROFIBUS is an open field and vendor-independent standard bus used in different fields of applications
like process automation & manufacturing. These are ensured through international standards like EN
50254 & EN 50170.
PROFIBUS simply allows communication between different manufacturers’ devices without any
adjustment of a special interface. It can be simply used for both time-critical, high-speed & difficult
communication-based tasks. PROFIBUS gives communication protocols like FMS & DP based on the
request, the transmission technologies like RS-485, IEC 1158-2 otherwise fiber optics are accessible.
https://www.elprocus.com/profibus/ 10/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
https://www.elprocus.com/profibus/ 11/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
The data link layer or Layer 2 simply describes the bus access protocol and the application layer or Layer
7 simply describes the application functions. The architecture of Profibus is shown above.
Application Profiles
Application Profiles of PROFIBUS mainly describe the communications protocol through the transmission
technology being utilized and they also describe the field devices’ behavior throughout communication
using PROFIBUS. So, the most significant Application Profile of PROFIBUS is presently the PROFIBUS
PA because this defines the function blocks & parameters of process automation devices like measuring
valves, positioners & transducers.
In the OSI model, the application layer simply provides the services of the application for the users. So
these services will make an efficient as well as open data transfer achievable in between the layer 2 &
application programs. The application layer includes two protocols DP & FMS.
DP
DP is a very efficient communications protocol that uses layer1, layer2, and the user interface. So, this
streamlined architecture will ensure a very efficient & fast transmission of data.
The DDLM or Direct Data Link Mapper simply provides the user interface to layer 2. The functions of
application obtainable to the operator and the device & the system behavior of the various types of DP
device are specified within the user interface.
https://www.elprocus.com/profibus/ 12/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
FSM
The universal communications protocol in FMS importance is to connect layers 1, 2 & 7. Layer 7 or
application layer mainly includes FMS (Fieldbus Message Specification) & the LLI (Lower Layer Interface).
So, FMS simply describes a huge number of communication services intended for the master to master &
master to slave communication. The lower layer interface defines the depiction of the FMS services over
the layer2 data transmission protocol.
FSM is a common communication profile that offers several complicated application functions used for
communication in between intelligent devices. But further PROFIBUS technical development & the
utilization of TCP/IP at the level of the cell, FMS will play a less significant role in the future.
The field bus system application is mostly determined through the transmission technology available and
also the normal demands made over bus systems like large distances, maximum transmission speed, high
transmission reliability, automation process and also extra requirements should be satisfied like operation
within dangerous areas, the transmission of data & energy on a normal cable.
Once it is not achievable to satisfy all necessities through a single transmission technology, then presently
three transmission methods are obtainable for PROFIBUS:
The Layer 2 or data link layer simply defines the bus access technique description with the security of
data. By using PROFIBUS, this is the master-slave technique within combination through the token
method.
Generally, the data link layer is accountable for moving messages or frames from one node to another. In
this layer, a unit of communication is a frame. This layer uses the packets from the network layer, to sum
up, them into frames If the size of the frame turns into very large, then the packet can be separated into
small frames. So data link layer at the receiver end receives signals & gathers them into messages or
frames.
The following diagram will show the main relationship of the data link layer toward the network & physical
layers. The main responsibilities of this layer are discussed below.
https://www.elprocus.com/profibus/ 14/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
Framing
The data link layer simply separates the stream of bits obtained from the network layer into controllable
frames.
Physical Addressing
If frames or messages are transmitted to various systems on the network, then this layer inserts a header
toward the frame to describe the sender & receiver of the frame or message.
Flow Control
At which point, the absorbed data speed through the receiver is low as compared to the data generated
within the sender, then the data link layer imposes a mechanism for flow control to avoid the receiver from
being overwhelming.
Error Control
The data link layer inserts consistency toward the physical layer by including mechanisms to notice &
retransmit lost frames. It also utilizes a mechanism to identify duplicate messages or frames. So, error
control is usually attained throughout a trailer including to the frame end.
Access control
https://www.elprocus.com/profibus/ 15/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
Once the minimum of two or above devices is linked to a similar link, then protocols of this layer are
required to decide which device has the power to control the link in a given time.
The PROFIBUS uses a uniform medium access protocol which is implemented through the data link layer
or layer2 of the OSI model. So, this also comprises data security, telegrams, and transmission protocols
handling. The layer2 within PROFIBUS is known as FDL or Fieldbus Data Link.
The FDL or Field bus Data Link simply works through a hybrid access technique that unites token passing
through a master-slave technique. The process control systems or the controllers within a PROFIBUS DP
network are the masters whereas the actuators & sensors are the slaves.
Profibus Dp Vs Pa
Profibus Dp Profibus Pa
PROFIBUS Decentralised Peripherals is used to Profibus process automation is used to enhance &
activate sensors & actuators through a centralized replace conventional systems within process
controller within industrial automation-based automation.
applications.
https://www.elprocus.com/profibus/ 16/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
It uses RS-485, although the physical layer is not the It uses MBP (Manchester Encoded Bus Powered)
same, the protocols are similar. physical layer.
It is identified as a bus network with high The Profibus-PA can be used as an alternative for
performance and it is capable of transmitting 1000s HART & 4 to 20mA signal transmission within the
of I/O point data in below a few milliseconds. process industries.
Profinet Profibus
Profine or process field net is a communication Profibus or process field bus is used for Fieldbus
protocol based on an Ethernet. communication within automation technology.
It includes two main categories like Profinet IO It includes three categories like Profibus DP, FMS &
PA.
& Profinet CBA.
https://www.elprocus.com/profibus/ 17/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
The cable length for Profinet is up to 100 meters. The cable length of Profibus is up to 1000 meters.
The physical layer used in Profinet is Ethernet. The physical layer used in Profinet is RS485.
The type of communication used in this is The technology used in this is provider or consumer.
master/slave.
Files used by an inprofinet are to determine Files used by a Profibus are to determine hardware
hardware are GSD files. are GSD files.
The files in Profinet use XML files. The files in Profibus use ASCII files.
Advantages
Disadvantages
The disadvantages of Profibus include the following.
Applications
It provides communication between the field sensors & the controllers or control system.
The PROFIBUS solutions are employed in industrial automation, industries process, manufacturing, etc.
It is used for both complex communication tasks & high-speed time-critical applications.
https://www.elprocus.com/profibus/ 19/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
Profibus is a protocol used in automation technology for field bus communication. This network simply
connects controllers & automation systems through different devices like sensors, encoders & actuators.
By using these networks, data exchange can be done with a single bus cable.
PROFINET & Ethernet both are not the same because Profinet is an application based on Ethernet.
Profibus is not frequently used but it is migrating gradually to current technologies like Profinet. But in the
Italian market, it is implemented as an essential protocol in industrial communication
Profinet cable is an industrial Ethernet cable and these cables are sometimes known as industrial two-pair
Cat5 or Cat5.
Thus, this is all about an overview of an industrial protocol namely Profibus which is mainly used for cross-
device communication as well as automation Profibus cables are used for industrial field bus fast-connect-
type systems, mainly developed for process applications. They provide an outstanding electrical
transmission performance for their own DP (Decentralized Peripherals) & PA (Process Automation)
applications. Here is a question for you, what is Profinet?
https://www.elprocus.com/profibus/ 20/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
SHARE THIS POST:
NEXT ›
‹ PREVIOUS
RELATED CONTENT
Loop Antenna : Design, Corner Reflector : Working, Space Division Multiplexing : Microstrip Antenna :
Working, Types, Radiation Types, Calculation, radiation Diagram, Working, Advantages, Construction, Working, Types,
Pattern & Its Applications pattern & Its Applications Disadvantages & Its Feeding Methods & Its
Applications Applications
https://www.elprocus.com/profibus/ 21/22
10/14/24, 10:22 AM Profibus : Architecture, Types, Differences & Its Applications
Advertise With Us Disclaimer Report Violation Image Usage Policy Privacy Policy
https://www.elprocus.com/profibus/ 22/22