1075 East Broadway Construction Drawings A1-A7 & Gn1-Gn3
1075 East Broadway Construction Drawings A1-A7 & Gn1-Gn3
80 GAL INDIRECT HOT WATER HIGH-EFFICIENCY DIRECT VENT 12" THK 3500 PSI CONC. FOUNDATION WALL CELLAR WALL/GENERAL LEGEND
HEATER, 14 GPM, (358 1ST HR) BOILER, 95% EFF., 1/2" GAS,
1" WATER, 3" VENT, #4 REBAR @ 12" O.C. BOTH WAYS- 24" WIDE X 12" H 3500 PSI CONC. FTG.
24"D X 68"H, STAINLESS STEEL,
16" X 23" X 34", 211,000 BTU VERTICALLY AND HORIZONTALLY (3) #4 REBAR CONTINUOUS AT BOTTOM-
1-1/2" DOM. WATER CONN,
LOCHINVAR SQUIRE SIT080 KNIGHT BY LOCHINVAR. #4 @ 18" O.C. OTHER WAY
T/ FOUNDATION WALL OR APPROVED EQ. - PROVIDE MAKE-UP COMB. AIR - SEE PLANS, SECTIONS AND DETAILS FOR
5'-0"
@ 16" BELOW T/ FIN. FIRST FLOOR (AS REQUIRED) PER MFR. RECOMS'
(S.Y.)
POST ABOVE TYPICAL-
- SIZE PVC OR APPD-TYPE VENT (SHOWN FOR REFERENCE)
SEE FIRST FLOOR PLAN
HOLD TREATED SILL WITH INTAKE, SIZE AND CONFIGURE FOR LOCATION AND DETAIL.
PLATE 5/8" BACK FROM (54'-4" wall)
2'-3" FACE OF FOUNDATION PER MFR. RECOMMENDATIONS.
HOLD FOUNDATION WALL, TYPICAL. 54'-2" AT CELLAR, NEW INTERIOR PARTITION:
WALL 1" BACK 1'-6" X 3'-2"
FROM EXTERIOR 2'-6" X 1'-10"H HVY-DTY. CORRUG.
HOLD DOWN
1-5/8" X 3-5/8 20GA GALVANIZED METAL
WALL ABOVE. AWNING WINDOW W2 PLASTIC WINDOW
STUDS AT 16" O.C. ON HEAVY GAUGE
1'-0"
2'-0"
MATCH HEIGHT WELL COVER @(4)
NEW GAS GALVANIZED METAL TRACK SECURED
G G TO SLAB WITH POWDER ACTUATED
FASTNERS.
1'-10 1/2"
1"
- PROVIDE WOOD STUD IN ALL DOOR
2'-6" X 1'-10"H
AND WINDOW JAMBS, OR FRAMED
(5' min.)
AWNING WINDOW
PLATE 5/8" BACK FROM
FACE OF FOUNDATION
SHWR 2'-6" X 1'-10"H SOFFIT (MIN.) VERIFY MIN. 12" 2'-6" X 1'-10"H
HOLD FOUNDATION
BLR AWNING WINDOW CONCRETE WALL AWNING WINDOW
- PROVIDE METAL STUD/SOLID TRACK
MATCH HEIGHT OF ABOVE WINDOW MATCH HEIGHT OF
FROM EXTERIOR
1'-0" A-V CL. OPP. WINDOWS OPENING, TYP. OPP. WINDOWS BLOCKING AT MIDPOINT OF ALL WALLS.
HAUNCH SLAB
MECH. RM. NOTE-
(16'-9" wall)
WALL ABOVE.
7'-0"
16'-9"
SOFFIT (7'-0")
2'-0" AT CEILING. 1 HR. SOFFIT @ SHWR- 7'-0" AFF
FR. WALLS. NEW AT CELLAR, NEW EXTERIOR FURRING:
HWH
3"
S S 1'-0" F.D. 5'-7 1/2" HAUNCH SLAB AS ABOVE, EXCEPT MAINTAIN 1-1/2" AIR
TO 12" THICK
MECH. SPACE BETWEEN STUD WALLS AND
BELOW WALL. 1"
DBL JST.
ROOM (3) #4 LONG WAY FOUNDATION.
NEW
HOUSE #4 @ 18" SHORT - SECURE STUDS TO FOUNDATION AT
GFI
MIDPOINT AT EVERY OTHER STUD.
5'-0"
(5' min.)
TRAP
1'-0"
1'-10 1/2"
2'-0"
NEW WATER
25'-0"
LINE OF SOLID BLOCKING LINE OF SOLID BLOCKING AS INDICATED ON SECTIONS AND NYS
ENERGY CONSERVATION NOTES.
(25'-0" wall)
24'-10"
27'-10"
OPEN CELLAR
6'-0" DOWN TO 6" ABOVE SLAB- INSULATION
ALIGN
ALIGN
(3) 2X12 LVL
SUB-PNL
3'-7 1/2"
W W
CELLAR 80 CFM OPEN NOT TO REST ON CONC. SLAB OR FOUN.
4'-0"
21'-10"
8'-1" HDRM.
(8'-2 1/2" TO SLAB) 3.5" X 3.5"
SD 8'-1" HDRM.
(2) LVL RIM JOIST
PSL POST
CO (8'-2 1/2" TO SLAB)
3'-1"
MOLD AND MOISTURE RESISTANT PURPLE
3'-0 1/2"
2'-0"
1'-0"
3.5" X 3.5"
BOARD, 5/8" TYPE X, EXCEPT-
1"
2'-0"
- USE 1/2" TYPE X CEMENT BOARD BEHIND
C 2021
4" OF ALL PARTITIONS.
(2) 1-3/4" LVL W/ 3/4" X 11" STL. PL. FLITCH BM.
5" WIDE BRICK SHELF
5"
FLUSH BEAM
1'-0"
8.5"
@ THIS WALL ONLY
7"
AT THIS WALL-
WALL, TYPICAL.
W6 EXTERIOR WALL TO EXTERIOR.) OF WINDOW TO SOFFIT. W5
1'-0" BOTH WAYS
METAL TERMITE SHIELD.
6'-6"
(2) LAYERS OF 2" RIGID EGRESS WINDOW ACCESS ACCESS EGRESS WINDOW
(11'-3" wall)
7'-11"
INSULATION AT EXTERIOR SOFFIT (MIN.) 3'-7" (43") AFF (45" AB.SLAB) PANEL PANEL SOFFIT (MIN.) 43" AFF (45" AB.SLAB)
2'-0"
11'-1"
(9'-6" wall)
(GARAGE ABOVE)
9'-6"
HOLD FOUNDATION
WALL 1" BACK SPACING WITHIN 12" OF CORNERS FASTENED WITH
FROM EXTERIOR
1/2" x 3" BEARING PLATE & SQUARE THREADED BOLT
1"
WALL ABOVE.
8"
(SHOWN FOR REFERENCE)
(WALL ABOVE)
2'-0"
1'-0"
HOLD DOWN
PERFORATED PVC
PLANTER ABOVE 7'-11" 8'-10" 3.5" SILL 8'-4" DRAINAGE BARREL OR
AROUND CHIMNEY
(9'-0" wall) BASIN, FILL ALL AROUND
AND 12" BELOW WITH
min 3'X3'
BOTTOM OF FOOTING @ 4'-0" BELOW GRADE
min as
6"
1"
1"
1"
reqd
HOLD TREATED SILL 11'-7" GRAVEL. TYP.
HOLD FOUNDATION PLATE 5/8" BACK FROM
WALL 1" BACK FACE OF FOUNDATION (11'-5" wall)
FROM EXTERIOR WALL, TYPICAL.
WALL ABOVE. 19'-9"
(19'-11" wall) HOLD FOUNDATION
HOLD DOWN ATTACHMENTS WALL 1" BACK 25'-1"
AT CORNERS, SEE FROM EXTERIOR (25'-3" wall)
GENERAL NOTES WALL ABOVE.
HOLD FOUNDATION
917-608-8169
516-570-6711
[email protected]
BARRY M. BASHKER, R.A.
11023
233 East Shore Rd, Suite 206
AND DETAILS FOR
ARCHITECTURE/PLANNING
bmbarchitecture.com
SPECIFICATION. TYP. WALL 1" BACK
FROM EXTERIOR
T/ FOUNDATION WALL
WALL ABOVE.
@ 16" BELOW T/ FIN. FIRST FLOOR
7'-0"
10'-0"
(S.Y.)
POST AS
INDICATED T/ GARAGE BRICK SHELF
NOTE- HEADER SCHEDULE INDICATES
@ 23" BELOW T/ FIN. 1ST FL MINIMUM HEADER SIZES
4X4- 12 GA, (REVERSE BRICK SHELF 6" WIDE X 7" DEEP)
4 SIDED GALV. PROPOSED CELLAR OPEN-FINISHED ROOM
POST ANCHOR
SHALL COMPLY WITH R303.1.2 FOR REQUIRED
Website:
Phone:
Email:
LIGHT AND VENTILATION= 775 S.F. EXCLUDES
Cell:
AREAS: MECH. ROOM, AND BATHROOM
WITH SEPARATE FAN.
ARCHITECTURE PLLC
VENTILATION:
775 S.F. X 8 FT = 6,200 CU.FT
6,200 X .35 CHANGES/HR= 2,170 C.F/HR
TYPICAL HEADER NOTE-
2,170 C.F./HOUR/60= MINIMUM 36 CFM.
1'-0"
8"
5'-0" MATERIAL CHANGE 2'-6" 6'-2" 2'-6" 2'-0" EGR. WDW. 5'-0" EGR. WDW. 7'-0"
CASEMENT
EGR. WDW.
CASEMENT
WDW. WALL/GENERAL LEGEND
1'-10 1/2"
CASEMENT
EGR. WDW.
3'-0"
GFI
GFI
GFI
GFI
3 1/2" OPEN TO
3'-9 1/2"
36" X 24" HIGH.
TYP. EQ. EQ. BELOW
BEDROOM 3- 103 S.F. 9'-0" CLG.
4'-11"
8"+/-
REQ'D LIGHT 8.2 S.F. ACTUAL 30 S.F.
3'-8 1/2" 2'-0" REQ'D AIR 4.1 S.F. ACTUAL 15 S.F.
EQ.
BATH 3
13'-5" PROVIDE 3 COAT CEMENTITIOUS STUCCO
10'-9"
10'-1" 10'-0"
11'-11 1/2"
7'-0"
10'-4"
3'-6"
4 1/2"
10'-4"
86" X 24" HIGH.
AT BOTTOM OF WALL.
- SEE ELEVATIONS FOR 3/4" X 3/4" ST.STL.
BATH 2 8" REVEAL CHANNELS.
W7 GFI 3'-0" 2'-0"
BEDROOM 2- 140 S.F. 9'-0" CLG. SD SD PROVIDE SPECIFIED WOOD SIDING PER MFR.
MASTER BDRM (4) - 213 S.F.
1'-10 1/2"
GFI
REQ'D LIGHT REQ'D LIGHT 17 S.F. ACTUAL 92 S.F. D3 CHANNEL BWN. FINISH MATERIALS AS SHOWN.
GFI
REQ'D AIR 5.6 S.F. ACTUAL 15 S.F. REQ'D AIR 8.5 S.F. ACTUAL 58 S.F.
25'-0"
8"
9'-0" CLG.
9"
8'-2"
6'-6"
W20
5" 2'-6" 1'-4 1/2"
3'-6"
17'-9"
30" X 72" CSMT.
SD SD
HALL
3'-6"
3'-6"
CO CO
- USE 2 X 3 WOOD STUDS @ 16" O.C. ON FLAT
CENTER ON
FRONT DR.
TEMPERED SLIDING
EGR. WDW.
CASEMENT
SD
GLASS DOORS
CO
3'-0"
REQ'D LIGHT 14.4 S.F. ACTUAL 45 S.F.
REQ'D AIR 7.2 S.F. ACTUAL 22.5 S.F. DN.
10'-2" CLG.
13'-5 1/2"
PITCH
GFI
GFI
GFI
GFI
14'-3"
@ 1/4"/FT.
4'-0"
11'-7" +/-
CUSTOM TEMPERED GLAZED UNIT
AS SHOWN ON ELEVATIONS
7" (FIXED WITH AWNING TRANSOM)
8'-0"
7"
4'-0"
6'-0" 5'-8"
EQ.
W23
2'-0"
24" X 36" FIXED.
4'-8" SILL HT.
3'-0" 5'-4"
8"
5'-6"
6'-6"
TEMPERED 5" 2'-10"
8" W24
4'-0"
6'-6"
GARAGE INSULATION NOTE- OPEN TO
PROVIDE MINIMUM R-19 INSUL. BELOW
CASEMENT CASEMENT AT GARAGE CEILING BELOW
EGR. WDW. EGR. WDW.
CONDITIONED SPACE ABOVE.
POST/COLUMN LEGEND:
C 2021
3'-0"
8"
2'-0" 1.5" X 5.5" PSL'S POST- AS SHOWN.
1'-8" EQ. 2'-6" 6'-10" 2'-6" EQ. W25 24" X 54" CSMT. RUN IN DIRECTION OF WALL (U.O.N.)
30" X 72" CSMT.
PITCH 30" X 72" CSMT. 0"
8'-4" 4'-3" 3.5" X 5.5" PSL POST-
2'-9"
W21
1/4" = 1'-0" W22
11'-5" 7'-11" 9'-0" 2' X 4' ALUM.
THIN BRICK AT PULL DOWN RUN IN DIRECTION OF WALL (U.O.N.)
CHIMNEY. 25'-3" ACCESS STR.
1'-8"
(2) 2x12 RIM JOIST 8'-6" JST/BM CONTINUOUS (TEMPERED). CONTINUOUS (TEMPERED).
HNGR. (2) 2x12 RIM JOIST W/ 42" X 21" AWN. (2) 2x12 RIM JOIST W/ 42" X 21" AWN. BEAM, FOUNDATION, -VIF,
TRANSOM TRANSOM
AND REPORT TO ARCHITECT
1'-10 1/2"
1'-2"
2'-0"
FLITCH BEAM-
GFI
GFI
GFI
REQ'D LIGHT 9 S.F. ACTUAL 45 S.F. 7" FULL BEARING.
(5.5")
REQ'D AIR 4.5 S.F. ACTUAL 22.5 S.F.
4'-11"
JOISTS
11'-2" PWDR. RM.
3'-6"
CASEMENT
10'-9"
7'-10"
7'-0"
GFI
GFI
917-608-8169
516-570-6711
[email protected]
BARRY M. BASHKER, R.A.
11023
PROPER OPERABLE GAVITY DAMPER OR
bmbarchitecture.com
SD
OPEN KITCHEN SIMILAR TYPE DAMPER.
EQ.
CO
SOFFIT- 2'-2" 3'-1"
3'-3"
TEMPERED SLIDING
9'-6" CLG.
@ 8'-4"
3'-6"
(2) 2" X 16" LVL W/ 3/4" X 15" STL. PL. FLITCH BM.
(2 FIXED, 4 OPP.)
1'-10 1/2"
GLASS DOORS-
CANTILEVER 2 X 12 LVL @ INSIDE, SURFACE MTD. LIGHT FIXTURE:
JOISTS OVER WALL CONCEALED GUTTER - PROVIDE HIGH-EFF. L.E.D. BULBS, TYP.
@ OUTSIDE-
25'-0"
(2) 2x12
17'-2"
TOILET ABOVE-
- SIZE AND TRIM AS SELECTED BY OWNER.
25'-0"
1'-0" VERIFY JOISTS
5'-0"
3'-11"
3'-11"
20'-1"
23'-4"
23'-8"
SD 15'-9 1/2"
A/C AIR HANDLER ABOVE, TYPE AS NOTED
(FLUSH @ BOT.)
CO
HD
11'-4" SIZE/TONS AS INDICATED, ZONING OF EX'G
6'-0"
(2) 2X12
3'-6" AH-#,
# TONS AND NEW A/C UNITS TO BE COORDINATED
LOW
D2 STAIR
WITH OWNER AND ARCHITECT IN FIELD.
Website:
2" SOLID- DN.
Phone:
INSULATED DR
Email:
8" W/ WOOD FINISH.
Cell:
5'-6"
2'-0"
ARCHITECTURE PLLC
R-18 (2) 2X12 LVL SD HARD WIRED SMOKE DETECTOR (ONLY)
JST/BM SD - USE PHOTOELECTIC TYPEIN KITCHEN:
SOFFIT-
8"
GFI
GFI
HNGR. CO
3 1/2"
10"
@ 8'-4"
CONTINUOUS
HD
8" HARD WIRED COMBINATION FIXED AND RATE OF RISE
(3) 2X12 LVL
BEAM TO FLITCH
INTERCONNECTED SO THAT ACTIVATION OF ONE
6'-6"
TOILET ABOVE-
DUCT FROM ALARM SHALL ACTIVATE ALL ALARMS.
2'-9" SPACE JOISTS HANGER.
3'-6"
BELOW
(3) 2x12 LVL
GARAGE NOTE-
11'-3"
10'-0"
5/8" TYPE X GWB. GARAGE SLAB THE ALARM SHALL DISTINGUISH BETWEEN A
7'-6"
42" X 86" FIXED
6" 3'-6"
TRANSOM
JST/BM HD
CO
W12
HNGR. LINE OF SOLID BLOCKING - PROVIDE MIN. ONE PER FLOOR IN HALL AS
INDICATED AND MIN. ONE IN EACH BEDROOM.
6" 42" X 86" FIXED
(TEMPERED).
42" X 86" FIXED
(TEMPERED). - PROVIDE ANY ADDITIONAL AS INDICATED ON PLANS.
8"
5.25"
W/ 42" X 21" AWN. W/ 42" X 21" AWN. - POWER- HARDWIRE AS ABOVE W/ BATTERY BACKUP.
3'-0"
W13 W14
(5.5")
SOLID BLOCKING OVER WALL GAS-FIRED FIREPLACE
7'-11"
THIN BRICK AT
9'-0" 8'-4" 4'-3" - SEALED TEMPERED GLASS.
CHIMNEY.
- UL LISTING UL307B, ANSI Z21.88b-2008
2
x1
6"
)2
(2
1'-8"
9"
2'-6"
2'-9"
PITCH
1/4" = 1'-0"
+6"
+6"
PITCH
+6"
3/8" = 1'-0"
+4.5"
+1.5"
0"
0"
1'-8"
+6"
3'-0" 6'-6"
3/8" = 1'-0"
11'-5" PITCH
6'-6"
0"
9'-0"
25'-3"
CHIMNEY WALL.
UNIT TO INSIDE OF
(2) WALL MOUNT A/C
3/8" = 1'-0"
PITCH
+ 7.5"
BELOW
BELOW
@ 1/4"/FT.
OPEN TO
OPEN TO
4'-3"
25'-0"
BARRY M. BASHKER, R.A. THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY
BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
ARCHITECTURE/PLANNING FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY
PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
233 East Shore Rd, Suite 206 DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
Great Neck, New York 11023 RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED
TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
Phone: 516-570-6711 FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE
Cell: 917-608-8169 PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,
Email: [email protected] OR FOR COMPLETION OF THIS PROJECT BY OTHERS.
ARCHITECTURE PLLC Website: bmbarchitecture.com C 2021
AT PROJECTED EAVES:
CHIMNEY APPROVED
5" X 5" SQ. SMOOTH/
TYPE VENT
2'-0"
ALUMINUM CLADDING OVER
PLYWOOD AT HORIZONTAL
HEAVY DUTY/
ALUMINUM LEADER
1'-2"
FASCIA SURFACE.
- ALUMINUM SNAP ON COPING TO MATCH GUTTERS
AT TOP- SLOPE AT 1/2" PER FT. AND OVERHANGS.
TO EXTERIOR, DRIP EDGE,
PER DETAIL.
2'-0"
- SOLID AZEK SOFFITS, COLOR
3'-5"
1'-10"
AS SELECTED BY OWNER
6'-4"
WINDOW NOTE:
2'-0"
1'-1"
ALL WINDOWS SHOWN SHALL
1'-10" 1'-10"
3'-6"
BE ENERGY STAR, INSULATED PARAPET BEYOND
DOUBLE GLAZED WINDOWS BY
ANDERSON, A SERIES (COMP. 4'-3"
OVER WOOD) OR 400 SERIES
1'-1"
1'-9"
WIDTH AND HEIGHT AS INDICATED
ON PLANS AND ELEVATIONS. SELECTION.
- TEMPERED GLASS IN SHOWERS,
12'-0"
@ SILLS LESS THAN 18", NEAR
STAIRS AS SHOWN, AND AS INDIC.
4'-6"
ON PLANS. TEMPERED GLASS,
6'-0"
9'-0"
STAINLESS STEEL
PROVIDE COPPER FLASHING RAIL AND POSTS.
7'-0"
(12" UP) OVER ICE SHIELD
FLASHING (24" UP) ALL WALL
SURFACES ADJACENT TO
3'-2"
3'-3"
LOWER FLAT ROOFS, TYP.
1'-8"
2'-0"
1'-2"
1'-2"
TURN CONCEALED
1'-9"
SOLID AZEK SOFFITS, COLOR GUTTER AROUND
AS SELECTED BY OWNER CORNER AS SHOWN.
1'-10"
4'-3 1/2"
9'-6"
REVEAL
C 2021
T/ FOUNDATION WALL
@ 16" BELOW T/ FIN. FIRST FLOOR STUCCO, COLOR AND
FINISH PER OWNER'S
SELECTION
4"
1'-10"
1'-7"
T/GAR.
4"
1'-11"
3'-6"
STEP GARAGE FOOTING DOWN PLANTER-BEHIND OF CELLAR JSTS.
FIN. HDRM.
THIN BRICK VENEER
8'-1"
8'-1"
AT 1 VERT. TO 2 HORIZ. BACK TO TOP OF SLAB)
TO HOUSE, TYPICAL. BELOW WINDOW
EL. 46.83'
1'-6"
BEYOND-
3'-7"
6'-4"
2'-0"
3'-6"
T/PLTFM.
917-608-8169
516-570-6711
[email protected]
BARRY M. BASHKER, R.A.
11023
233 East Shore Rd, Suite 206
ARCHITECTURE/PLANNING
bmbarchitecture.com
1'-1"
FLASHING (24" UP) ALL WALL - CUSTOM INSULATED-DOUBLE PLANTER PART OF LANDSCAPING,
SURFACES ADJACENT TO GLAZED GLASS SIDE LITES AND PROVIDE 24" DEEP, TAPERED
Website:
3 COAT CEMENTITIOUS LOWER FLAT ROOFS, TYP. TRANSOM, MINIMAL MULLIONS,
Phone:
FOUNDATION AT RETAINING WALLS,
Email:
STUCCO, COLOR AND
Cell:
BY GLAZER. 8" WIDE AT BOTTOM, REINFORCED
29'-10"
FINISH PER OWNER'S - MATCHING FINISH INSULATED CONCRETE WITH #3 @ 8" O.C. BOTH
SELECTION FIBERGLASS GARAGE DOOR, WAYS ALL AROUND.
1'-8"
ARCHITECTURE PLLC
T/2ND FL.
2'-0"
1'-2"
1ST CLG.
1'-10"
1'-9"
REVEAL
FILL ABOVE GARAGE
DOOR, ALUM. FINISH
9'-6"
2'-0"
THIN BRICK
7'-0"
1'-10"
2'-0"
ALUMINUM LEADER
TO MATCH GUTTERS
3'-6"
AND OVERHANGS. 5'-0" MATERIAL CHANGE
2'-0"
1'-1"
1'-10"
3'-5"
MASTER
BDRM. CLG. T/PLTFM.
1'-1"
ALIGN TOPS 1'-10"
1'-9"
3'-0" 2ND CLG.
(ALIGN WITH DOOR
TRANSOM AS POSSIBLE)
2'-0"
12'-0"
TEMPERED
4'-6"
10'-2"
6'-0"
6'-0"
EQ. EQ.
8'-0"
5'-8"
3'-2"
3'-3"
1'-8"
1'-8"
T/2ND FL.
1'-2"
1ST CLG.
1'-9"
REVEAL
VERIFY DIRECTION OF
CASEMENT WINDOW SWINGS
WITH OWNER. PROVIDE SHOP
4'-0"
4'-3" DRAWINGS FOR OWNERS
9'-6"
TYPICAL
7'-6"
7'-0"
C 2021
TREATED
3'-6"
WOOD DECK
4"
T/1ST FL.
CLR. CLG.
2'-8"
1'-10"
FIN. HDRM.
8'-1"
(8'-3" FROM BTM.
OF CELLAR JSTS.
1'-0"
TO TOP OF SLAB)
2'-0"
LED SOFFIT LIGHTS-
CENTER IN SOFFIT
917-608-8169
516-570-6711
[email protected]
BARRY M. BASHKER, R.A.
11023
233 East Shore Rd, Suite 206
ARCHITECTURE/PLANNING
bmbarchitecture.com
1'-10"
5"
MASTER
1'-10"
1'-9"
BDRM. CLG.
GLASS DOORS.
PANEL- ALIGN WITH INSULATED DOUBLE GLAZED WINDOWS BY:
Website:
TOP OF DOOR. ANDERSON, A SERIES (COMP. OVER WOOD) OR
Phone:
Email:
8'-0"
Cell:
AS SELECTED BY OWNER.
AND ELEVATIONS.
ARCHITECTURE PLLC
- TEMPERED GLASS IN SHOWERS,
T/2ND FL. - TEMPERED GLASS AT ALL DOORS,
- TEMPERED GLASS AT ALL SILLS
1'-2"
4'-3"
SHOWN
RISER AS
FLOOR CONSTRUCTION
TREAD
AS SHOWN
3'-6"
4" MAX.
2'-10"
11'-2"
EQ.
1'-2"
7'-0"
3'-6" 3'-6"
EQ.
1'-10"
3'-0"
2'-0"
2'-8"
3'-0"
7'-0"
1'-2"
1'-4"
1'-0"
1'-2"
1'-0"
1'-10"
6"
2'
-4
"
12" 2'-0"
3"
1'-0"
11"
GLUE
1'-10"
11"
9'-0"
(16.45' + 17.53')/2 = 17.0' EL.
5"
2'-8"
STREET @ FRONT OF PROPERTY=
AVERAGE CENTERLINE OF GRADE OF
1'-0"
29'-10"
11"
BARRY M. BASHKER, R.A. THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY
BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
ARCHITECTURE/PLANNING FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY
PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
233 East Shore Rd, Suite 206 DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
Great Neck, New York 11023 RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED
TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
Phone: 516-570-6711 FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE
Cell: 917-608-8169 PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,
Email: [email protected] OR FOR COMPLETION OF THIS PROJECT BY OTHERS.
ARCHITECTURE PLLC Website: bmbarchitecture.com C 2021
3'-6"
6'-4"
2'-0"
3'-6"
1'-1"
1'-8"
1'-10"
10'-2"
9'-0"
9'-0"
1'-5"
1'-2"
9'-6"
8'-1"
FOUNDATION WATERPROOFING:
PROVIDE ADHERED BITUM. WATERPROOFING
MEMBRANE BITUTHENE 3000 OR EQUAL, FROM TOP
OF FOUNDATION WALL DOWN TO TOP OF FOOTING.
3"
- PROTECT WITH 2" RIGID INSULATION PRIOR TO
BACKFILLING, R10 7"
12" THK 4000 PSI CONC. FOUNDATION WALL
#4 REBAR @ 12" O.C. BOTH WAYS-
VERTICALLY AND HORIZONTALLY
3
4 " STONE / GRAVEL
BARRY M. BASHKER, R.A. THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY
BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
ARCHITECTURE/PLANNING FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY
PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
233 East Shore Rd, Suite 206 DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
Great Neck, New York 11023 RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED
TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
Phone: 516-570-6711 FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE
Cell: 917-608-8169 PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,
Email: [email protected] OR FOR COMPLETION OF THIS PROJECT BY OTHERS.
ARCHITECTURE PLLC Website: bmbarchitecture.com C 2021
STEP FOOTING DETAIL