NEW HWH- NEW BOILER-

80 GAL INDIRECT HOT WATER HIGH-EFFICIENCY DIRECT VENT 12" THK 3500 PSI CONC. FOUNDATION WALL CELLAR WALL/GENERAL LEGEND
HEATER, 14 GPM, (358 1ST HR) BOILER, 95% EFF., 1/2" GAS,
1" WATER, 3" VENT, #4 REBAR @ 12" O.C. BOTH WAYS- 24" WIDE X 12" H 3500 PSI CONC. FTG.
24"D X 68"H, STAINLESS STEEL,
16" X 23" X 34", 211,000 BTU VERTICALLY AND HORIZONTALLY (3) #4 REBAR CONTINUOUS AT BOTTOM-
1-1/2" DOM. WATER CONN,
LOCHINVAR SQUIRE SIT080 KNIGHT BY LOCHINVAR. #4 @ 18" O.C. OTHER WAY
T/ FOUNDATION WALL OR APPROVED EQ. - PROVIDE MAKE-UP COMB. AIR - SEE PLANS, SECTIONS AND DETAILS FOR

5'-0"
@ 16" BELOW T/ FIN. FIRST FLOOR (AS REQUIRED) PER MFR. RECOMS'

(S.Y.)
POST ABOVE TYPICAL-
- SIZE PVC OR APPD-TYPE VENT (SHOWN FOR REFERENCE)
SEE FIRST FLOOR PLAN
HOLD TREATED SILL WITH INTAKE, SIZE AND CONFIGURE FOR LOCATION AND DETAIL.
PLATE 5/8" BACK FROM (54'-4" wall)
2'-3" FACE OF FOUNDATION PER MFR. RECOMMENDATIONS.
HOLD FOUNDATION WALL, TYPICAL. 54'-2" AT CELLAR, NEW INTERIOR PARTITION:
WALL 1" BACK 1'-6" X 3'-2"
FROM EXTERIOR 2'-6" X 1'-10"H HVY-DTY. CORRUG.
HOLD DOWN
1-5/8" X 3-5/8 20GA GALVANIZED METAL
WALL ABOVE. AWNING WINDOW W2 PLASTIC WINDOW
STUDS AT 16" O.C. ON HEAVY GAUGE

1'-0"

2'-0"
MATCH HEIGHT WELL COVER @(4)
NEW GAS GALVANIZED METAL TRACK SECURED
G G TO SLAB WITH POWDER ACTUATED
FASTNERS.
1'-10 1/2"

- PROVIDE FOAM SILL/ SEALER GASKET


OR EQ. BETWEEN TRACKS AND CONC.
1"

1"
- PROVIDE WOOD STUD IN ALL DOOR
2'-6" X 1'-10"H
AND WINDOW JAMBS, OR FRAMED
(5' min.)

AWNING WINDOW
PLATE 5/8" BACK FROM
FACE OF FOUNDATION

MATCH HEIGHT OPENINGS. PROVIDE 3/4" PLYWOOD


7'-3"
HOLD TREATED SILL

W1 SOFFIT (MIN.) BLOCKING BETWEEN STUDS AT WALL


NEW MOUNTED CABINETS OR ACCESSORIES.
WALL, TYPICAL.

SHWR 2'-6" X 1'-10"H SOFFIT (MIN.) VERIFY MIN. 12" 2'-6" X 1'-10"H

HOLD FOUNDATION
BLR AWNING WINDOW CONCRETE WALL AWNING WINDOW
- PROVIDE METAL STUD/SOLID TRACK
MATCH HEIGHT OF ABOVE WINDOW MATCH HEIGHT OF

FROM EXTERIOR
1'-0" A-V CL. OPP. WINDOWS OPENING, TYP. OPP. WINDOWS BLOCKING AT MIDPOINT OF ALL WALLS.

HAUNCH SLAB
MECH. RM. NOTE-
(16'-9" wall)

WALL 1" BACK


BY OWN.

WALL ABOVE.
7'-0"
16'-9"

1/2" TYPE X GWB. TMPR GL W3 W4

SOFFIT (7'-0")
2'-0" AT CEILING. 1 HR. SOFFIT @ SHWR- 7'-0" AFF
FR. WALLS. NEW AT CELLAR, NEW EXTERIOR FURRING:
HWH
3"
S S 1'-0" F.D. 5'-7 1/2" HAUNCH SLAB AS ABOVE, EXCEPT MAINTAIN 1-1/2" AIR
TO 12" THICK
MECH. SPACE BETWEEN STUD WALLS AND
BELOW WALL. 1"

DBL JST.
ROOM (3) #4 LONG WAY FOUNDATION.
NEW
HOUSE #4 @ 18" SHORT - SECURE STUDS TO FOUNDATION AT

GFI
MIDPOINT AT EVERY OTHER STUD.
5'-0"
(5' min.)

TRAP

1'-0"
1'-10 1/2"

1'-0" - KRAFT BACKED FIBERGLASS BATTS


INSULATION BETWEEN STUDS, R-VALUE
(WALL ABOVE)

2'-0"
NEW WATER
25'-0"

LINE OF SOLID BLOCKING LINE OF SOLID BLOCKING AS INDICATED ON SECTIONS AND NYS
ENERGY CONSERVATION NOTES.

(25'-0" wall)
24'-10"
27'-10"

OPEN CELLAR
6'-0" DOWN TO 6" ABOVE SLAB- INSULATION

ALIGN

ALIGN
(3) 2X12 LVL
SUB-PNL

3'-7 1/2"
W W
CELLAR 80 CFM OPEN NOT TO REST ON CONC. SLAB OR FOUN.

(2) 2X12 LVL


FLUSH
FLUSH
CELLAR WALL TYPICAL.

4'-0"

21'-10"
8'-1" HDRM.
(8'-2 1/2" TO SLAB) 3.5" X 3.5"
SD 8'-1" HDRM.
(2) LVL RIM JOIST

PSL POST
CO (8'-2 1/2" TO SLAB)

OPENING IN WALL 7'-6" +/-


(2) 2X12 LVL HDRM.
CELLAR SHEATHING/ WALLBOARD NOTE:
SUB-PNL ALL SHEATHING WITHIN CELLAR SHALL BE
3'-3"

3'-1"
MOLD AND MOISTURE RESISTANT PURPLE

3'-0 1/2"
2'-0"
1'-0"

3.5" X 3.5"
BOARD, 5/8" TYPE X, EXCEPT-
1"

PSL POST 9-3/4" TREADS


CL. UP 14R SEE FIRST FL

2'-0"
- USE 1/2" TYPE X CEMENT BOARD BEHIND

OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,


TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY

RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED


PLAN FOR

PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE


DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY

FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE


PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
GWB-LAMINATE 7-7/8" STAIR OP'G ALL TILE FINISHES, AND
- USE 5/8" TYPE X CEMENT BOARD AT BOTTOM
1'-7"

C 2021
4" OF ALL PARTITIONS.
(2) 1-3/4" LVL W/ 3/4" X 11" STL. PL. FLITCH BM.
5" WIDE BRICK SHELF
5"

FLUSH BEAM
1'-0"

8.5"
@ THIS WALL ONLY

PLATE 5/8" BACK FROM


FACE OF FOUNDATION
(@ CONTRACTOR'S OPTION- SOFFIT NOTE-
DOUBLE TREATED WOOD SILL PLATE

7"
AT THIS WALL-

HOLD TREATED SILL


PLACE BEAM BELOW JOISTS, PROVIDE SHALLOW DUCT
(2) LVL RIM JOIST
7" REINF. CONC. 2'-0" FOR MINIMUM SOFFIT SIZE,
W/ #5 @ 9" O.C.
RUN FLOOR JOIST CONTINUOUS MAINTAIN 4" ABOVE TOP OVER COPPER OR OTHER APPROVED

WALL, TYPICAL.
W6 EXTERIOR WALL TO EXTERIOR.) OF WINDOW TO SOFFIT. W5
1'-0" BOTH WAYS
METAL TERMITE SHIELD.

OR FOR COMPLETION OF THIS PROJECT BY OTHERS.


(6'-6" wall)
2'-6" X 3'-6"H 22'-0 1/2" 2'-6" X 3'-6"H
STEP FOOTING

6'-6"
(2) LAYERS OF 2" RIGID EGRESS WINDOW ACCESS ACCESS EGRESS WINDOW
(11'-3" wall)

7'-11"

INSULATION AT EXTERIOR SOFFIT (MIN.) 3'-7" (43") AFF (45" AB.SLAB) PANEL PANEL SOFFIT (MIN.) 43" AFF (45" AB.SLAB)
2'-0"
11'-1"

OF THIS WALL ONLY.


UNEXCAVATED 2'-6" 2'-6"
5/8" DIA. ANCHOR BOLTS AT 10" LONG @ 32" O.C.
STEP FOOTING

(9'-6" wall)

(GARAGE ABOVE)
9'-6"

HOLD FOUNDATION
WALL 1" BACK SPACING WITHIN 12" OF CORNERS FASTENED WITH
FROM EXTERIOR
1/2" x 3" BEARING PLATE & SQUARE THREADED BOLT

1"
WALL ABOVE.

POST ABOVE TYPICAL-


6" 6"

8"
(SHOWN FOR REFERENCE)
(WALL ABOVE)

2'-0"
1'-0"

SEE FIRST FLOOR PLAN


6"
3'-0"

FOR LOCATION AND DETAIL.


3" DRAIN TO 50 GALLON
1'-7"

HOLD DOWN
PERFORATED PVC
PLANTER ABOVE 7'-11" 8'-10" 3.5" SILL 8'-4" DRAINAGE BARREL OR
AROUND CHIMNEY
(9'-0" wall) BASIN, FILL ALL AROUND
AND 12" BELOW WITH

min 3'X3'
BOTTOM OF FOOTING @ 4'-0" BELOW GRADE

min as
6"
1"

1"

1"

reqd
HOLD TREATED SILL 11'-7" GRAVEL. TYP.
HOLD FOUNDATION PLATE 5/8" BACK FROM
WALL 1" BACK FACE OF FOUNDATION (11'-5" wall)
FROM EXTERIOR WALL, TYPICAL.
WALL ABOVE. 19'-9"
(19'-11" wall) HOLD FOUNDATION
HOLD DOWN ATTACHMENTS WALL 1" BACK 25'-1"
AT CORNERS, SEE FROM EXTERIOR (25'-3" wall)
GENERAL NOTES WALL ABOVE.
HOLD FOUNDATION

917-608-8169
516-570-6711

[email protected]
BARRY M. BASHKER, R.A.

11023
233 East Shore Rd, Suite 206
AND DETAILS FOR

ARCHITECTURE/PLANNING

bmbarchitecture.com
SPECIFICATION. TYP. WALL 1" BACK
FROM EXTERIOR
T/ FOUNDATION WALL
WALL ABOVE.
@ 16" BELOW T/ FIN. FIRST FLOOR
7'-0"

10'-0"
(S.Y.)

Great Neck, New York


(S.Y.)

POST AS
INDICATED T/ GARAGE BRICK SHELF
NOTE- HEADER SCHEDULE INDICATES
@ 23" BELOW T/ FIN. 1ST FL MINIMUM HEADER SIZES
4X4- 12 GA, (REVERSE BRICK SHELF 6" WIDE X 7" DEEP)
4 SIDED GALV. PROPOSED CELLAR OPEN-FINISHED ROOM
POST ANCHOR
SHALL COMPLY WITH R303.1.2 FOR REQUIRED

Website:
Phone:

Email:
LIGHT AND VENTILATION= 775 S.F. EXCLUDES

Cell:
AREAS: MECH. ROOM, AND BATHROOM
WITH SEPARATE FAN.

ARCHITECTURE PLLC
VENTILATION:
775 S.F. X 8 FT = 6,200 CU.FT
6,200 X .35 CHANGES/HR= 2,170 C.F/HR
TYPICAL HEADER NOTE-
2,170 C.F./HOUR/60= MINIMUM 36 CFM.
1'-0"

PROVIDE (2)X12 HEADER AT ALL NEW WINDOWS AND DOORS.


WHERE SPACE OR CONDITIONS DO NOT PERMIT, FOLLOW THE 80 CFM PROVIDED> 36 CFM (OK).
MINIMUM HEADER SIZES PER ABOVE. @ LOAD BEARING AND
#4 X 3'-0" @ 18" O.C. NON-LOAD BEARING WALLS- UNLESS OTHERWISE NOTED ON LIGHT:
1'-0"

(3) #4 @ BOT. DRAWINGS FOR LARGER HEADER/POSTS. SHALL BE SUFFICIENT TO PROVIDE


3" MIN.

1'-0" AVERAGE ILLUMINATION OF 6 FOOTCANDLES


(65 LUX) OVER THE AREA OF THE ROOM AT
CONCRETE FOOTING
SPACE TEMP. REINF.
A HEIGHT OF 30 INCHES ABOVE THE FLOOR.
AS INDICATED ON
DRAWINGS BARS @ 6" O.C. X SLAB HAUNCH DETAIL OK.
3'-0" AT POSTS.
24" AS INDIC. N.T.S.

POST FOOTING DETAIL


N.T.S.
W15 W16 W17 W18 W19
6" 30" X 72" CSMT. 30" X 72" CSMT. 24" X 54" CSMT.
53'-10" (2) 30" X 72" CSMT. 86" X 21" AWN. (HIGH)
CASEMENT CASEMENT

8"
5'-0" MATERIAL CHANGE 2'-6" 6'-2" 2'-6" 2'-0" EGR. WDW. 5'-0" EGR. WDW. 7'-0"
CASEMENT
EGR. WDW.
CASEMENT
WDW. WALL/GENERAL LEGEND

1'-10 1/2"
CASEMENT
EGR. WDW.
3'-0"

GFI

GFI

GFI

GFI
3 1/2" OPEN TO

3'-9 1/2"
36" X 24" HIGH.
TYP. EQ. EQ. BELOW
BEDROOM 3- 103 S.F. 9'-0" CLG.

4'-11"

8"+/-
REQ'D LIGHT 8.2 S.F. ACTUAL 30 S.F.
3'-8 1/2" 2'-0" REQ'D AIR 4.1 S.F. ACTUAL 15 S.F.

EQ.
BATH 3
13'-5" PROVIDE 3 COAT CEMENTITIOUS STUCCO
10'-9"

10'-1" 10'-0"
11'-11 1/2"
7'-0"

10'-4"
3'-6"
4 1/2"

6'-2" SHEATING. PROVIDE DRAINING J-CHANNEL

10'-4"
86" X 24" HIGH.

AT BOTTOM OF WALL.
- SEE ELEVATIONS FOR 3/4" X 3/4" ST.STL.
BATH 2 8" REVEAL CHANNELS.
W7 GFI 3'-0" 2'-0"

BEDROOM 2- 140 S.F. 9'-0" CLG. SD SD PROVIDE SPECIFIED WOOD SIDING PER MFR.
MASTER BDRM (4) - 213 S.F.
1'-10 1/2"

CO CO RECOMMENDATIONS. PROVIDE REVEAL


11.2 S.F. ACTUAL 30 S.F.

GFI
REQ'D LIGHT REQ'D LIGHT 17 S.F. ACTUAL 92 S.F. D3 CHANNEL BWN. FINISH MATERIALS AS SHOWN.

GFI
REQ'D AIR 5.6 S.F. ACTUAL 15 S.F. REQ'D AIR 8.5 S.F. ACTUAL 58 S.F.

RECESSED DRAIN- SEE DETAILS


WITH 8'-2" X 1'-9" AWN. TRANSOM
8'-2" X 8'-0" SLIDING GLASS DRS
NEW INTERIOR WOOD FRAMED WALL.
2 X 4 WOOD STUDS @ 16" O.C, W/ 5/8" TYPE X

25'-0"
8"

9'-0" CLG.
9"

8'-2"
6'-6"
W20
5" 2'-6" 1'-4 1/2"

3'-6"

17'-9"
30" X 72" CSMT.

SD SD
HALL

3'-6"

3'-6"
CO CO
- USE 2 X 3 WOOD STUDS @ 16" O.C. ON FLAT
CENTER ON
FRONT DR.

TEMPERED SLIDING
EGR. WDW.
CASEMENT

13'-5" 3'-2 1/2" 11'-2 1/2" WHERE INDICATED TO BE 2.5" THICK.


2'-6"

SD

GLASS DOORS
CO

BEDROOM 1- 180 S.F. 9'-0" CLG. (12'-0" TO JSTS)


STAIR 11'-4" CLG.

3'-0"
REQ'D LIGHT 14.4 S.F. ACTUAL 45 S.F.
REQ'D AIR 7.2 S.F. ACTUAL 22.5 S.F. DN.
10'-2" CLG.
13'-5 1/2"

PITCH

GFI

GFI

GFI

GFI
14'-3"

@ 1/4"/FT.

4'-0"
11'-7" +/-
CUSTOM TEMPERED GLAZED UNIT
AS SHOWN ON ELEVATIONS
7" (FIXED WITH AWNING TRANSOM)

8'-0"
7"

4'-0"
6'-0" 5'-8"

EQ.
W23

2'-0"
24" X 36" FIXED.
4'-8" SILL HT.
3'-0" 5'-4"
8"

5'-6"
6'-6"
TEMPERED 5" 2'-10"
8" W24

4'-0"
6'-6"
GARAGE INSULATION NOTE- OPEN TO
PROVIDE MINIMUM R-19 INSUL. BELOW
CASEMENT CASEMENT AT GARAGE CEILING BELOW
EGR. WDW. EGR. WDW.
CONDITIONED SPACE ABOVE.
POST/COLUMN LEGEND:

OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,


TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY

RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED


PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY

FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE


PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
TYP. BUILT-UP POST OF 1.5" X 3.5" OR

C 2021
3'-0"

8"
2'-0" 1.5" X 5.5" PSL'S POST- AS SHOWN.
1'-8" EQ. 2'-6" 6'-10" 2'-6" EQ. W25 24" X 54" CSMT. RUN IN DIRECTION OF WALL (U.O.N.)
30" X 72" CSMT.
PITCH 30" X 72" CSMT. 0"
8'-4" 4'-3" 3.5" X 5.5" PSL POST-
2'-9"
W21
1/4" = 1'-0" W22
11'-5" 7'-11" 9'-0" 2' X 4' ALUM.
THIN BRICK AT PULL DOWN RUN IN DIRECTION OF WALL (U.O.N.)
CHIMNEY. 25'-3" ACCESS STR.
1'-8"

17'-2" 5.5" X 5.5" PSL POST

OR FOR COMPLETION OF THIS PROJECT BY OTHERS.


DOUBLE PSL POST- SIZE AS INDICATED-
CONNECT TRIPLE JST WHERE SHOWN BELOW A HEADER OR
2'-3" TO RIM JOIST W/
54'-4" NOT CONTINUOUS BEAM, INSTALL AS
16 GA. JST. HNGR.
TYP. JACK AND KING STUDS.
W8
CEILING AT 3'-6" W9 3'-6" W10
24" X 48" CSMT. 2'-0" 15'-1 1/2" (2) 2x12 LVL + 2X12 BEAM, 1'-0" POST NOTE-
CONTINUOUS BATHROOM SEE DETAIL VERIFY PROPER BEARING- ON SILL,
2'-4" 42" X 86" FIXED 42" X 86" FIXED
8"

(2) 2x12 RIM JOIST 8'-6" JST/BM CONTINUOUS (TEMPERED). CONTINUOUS (TEMPERED).
HNGR. (2) 2x12 RIM JOIST W/ 42" X 21" AWN. (2) 2x12 RIM JOIST W/ 42" X 21" AWN. BEAM, FOUNDATION, -VIF,
TRANSOM TRANSOM
AND REPORT TO ARCHITECT
1'-10 1/2"

1'-2"

STUDY/GST- 113 S.F. 9'-6" CLG.

2'-0"
FLITCH BEAM-
GFI

GFI

GFI
REQ'D LIGHT 9 S.F. ACTUAL 45 S.F. 7" FULL BEARING.
(5.5")
REQ'D AIR 4.5 S.F. ACTUAL 22.5 S.F.
4'-11"
JOISTS
11'-2" PWDR. RM.
3'-6"

ABOVE 3'-7 1/2" CONNECT TRIPLE JST


8" TO (SINGLE) RIM JOIST.

+ (2) 2 X 7 1/4" LVL- CONTINUOUS


EQ.

TRIPLE JST- 4" BEARING.


WITH 84" X 21" AWNING TRANSOM

CASEMENT
10'-9"

(2) 42" X 86" CSMT. (TEMPERED)

EGR. WDW. TOILET ABOVE- CONNECT W/ 16 GA.


16'-9"

7'-10"
7'-0"

GFI

GFI

SPACE JOISTS JST. HNGR.

23'-4" X 9'-0" CUSTOM SLIDING DOORS, WITH 6 EQUAL UNITS,


TO CENTER.
GFI
(1) 2X12 RIM JOIST

(2) FIXED, AND 4 SLIDING AS SHOWN. (TEMPERED) WITH


(2) 2X12 LVL CEILING MTD. (U.O.N.) EXHAUST FAN-
FLUSH IN FLOOR

CL OPEN KITCHEN, DINING 655 S.F.


10'-2"

WHISPER QUIET BY PANASONIC, VARIABLE


CL

AND LIVING ROOMS


(1) 2X12 LVL +

(2) 2X12 LVL W/ 3/8" X 11" STL. PL. FLITCH BM.

SPEED 80 OR 110 CFM.

OVHD. MOTOR, REMOTE, & EXTERIOR KEYPAD.


3'-6"

REQ'D LIGHT 52.4 S.F. ACTUAL 398 S.F.


9'-9 1/2"

5" FLEXIBLE DUCT TO EXTERIOR, AND PROVIDE

(1) 2X12 LVL


W7

REQ'D AIR 26.2 S.F. ACTUAL 176.6 S.F.

917-608-8169
516-570-6711

[email protected]
BARRY M. BASHKER, R.A.

11023
PROPER OPERABLE GAVITY DAMPER OR

233 East Shore Rd, Suite 206


ARCHITECTURE/PLANNING
3'-6"

bmbarchitecture.com
SD
OPEN KITCHEN SIMILAR TYPE DAMPER.
EQ.

CO
SOFFIT- 2'-2" 3'-1"
3'-3"

TEMPERED SLIDING
9'-6" CLG.
@ 8'-4"
3'-6"

(2) 2" X 16" LVL W/ 3/4" X 15" STL. PL. FLITCH BM.
(2 FIXED, 4 OPP.)
1'-10 1/2"

GLASS DOORS-
CANTILEVER 2 X 12 LVL @ INSIDE, SURFACE MTD. LIGHT FIXTURE:
JOISTS OVER WALL CONCEALED GUTTER - PROVIDE HIGH-EFF. L.E.D. BULBS, TYP.
@ OUTSIDE-
25'-0"

(2) 2x12
17'-2"

RECESSED LIGHT FIXTURE:

Great Neck, New York


(2) 2X12 LVL W/ 3/4" X 11" STL. PL. FLITCH BM.
(2) 2x12 D1 SEE DETAILS.
(FLUSH AT BOT.)

- PROVIDE HIGH-EFF. L.E.D. BULBS, TYP.


EQ.

TOILET ABOVE-
- SIZE AND TRIM AS SELECTED BY OWNER.

25'-0"
1'-0" VERIFY JOISTS
5'-0"
3'-11"

3'-11"

20'-1"

23'-4"
23'-8"

SD 15'-9 1/2"
A/C AIR HANDLER ABOVE, TYPE AS NOTED

(FLUSH @ BOT.)
CO
HD
11'-4" SIZE/TONS AS INDICATED, ZONING OF EX'G
6'-0"

(2) 2X12

3'-6" AH-#,
# TONS AND NEW A/C UNITS TO BE COORDINATED
LOW

D2 STAIR
WITH OWNER AND ARCHITECT IN FIELD.

Website:
2" SOLID- DN.

Phone:
INSULATED DR

Email:
8" W/ WOOD FINISH.

Cell:
5'-6"
2'-0"

3'-0" 9'-0" SMOKE DETECTORS


STAIR
3'-1"

(2) 2x12 UP SD HARD WIRED COMBINATION SMOKE DETECTOR


JST/BM 10" TREADS JST/BM CO AND CARBON MONOXIDE DETECTOR:
1'-8"

HNGR. 17R @ 7.5" +/- HNGR.

ARCHITECTURE PLLC
R-18 (2) 2X12 LVL SD HARD WIRED SMOKE DETECTOR (ONLY)
JST/BM SD - USE PHOTOELECTIC TYPEIN KITCHEN:
SOFFIT-
8"
GFI
GFI

HNGR. CO
3 1/2"

10"

@ 8'-4"
CONTINUOUS

HD
8" HARD WIRED COMBINATION FIXED AND RATE OF RISE
(3) 2X12 LVL

CUSTOM TEMPERED GLAZED UNIT


8"

AS SHOWN ON ELEVATIONS (FIXED)


W11 HEAT DETECTOR WITH SMART AUDIBLE ALARM:
7" 7" CONNECT (2) LVL ALL DETECTORS SHALL BE HARD WIRED AND
DBL JST.
SOLID BLOCKING OVER WALL

BEAM TO FLITCH
INTERCONNECTED SO THAT ACTIVATION OF ONE
6'-6"

GARAGE WITH 16 GA. JST.


(1) 2x12 RIM JST

TOILET ABOVE-
DUCT FROM ALARM SHALL ACTIVATE ALL ALARMS.
2'-9" SPACE JOISTS HANGER.
3'-6"

11'-1" CLG. 23'-6 1/2"


11"+/-

BELOW
(3) 2x12 LVL

TO CENTER. - WHEN COMBINATION ALARMS ARE INSTALLED,


7'-11"

GARAGE NOTE-
11'-3"

10'-0"

W/ 42" X 21" AWN.

5/8" TYPE X GWB. GARAGE SLAB THE ALARM SHALL DISTINGUISH BETWEEN A
7'-6"
42" X 86" FIXED

7'-6" SMOKE OR CARBON MONOXIDE ALARM.


(TEMPERED).

AT CEILING. 1 HR. 4" THK 1'-6"


9'-6"

6" 3'-6"
TRANSOM

FR. WALLS. 3'-6" (2) 2x12


SHALL COMPLY WITH CURRENT RESIDENTIAL
8"

CODE STANDARDS, SECTION R314 OR LATEST:


1'-4"

JST/BM HD
CO
W12

HNGR. LINE OF SOLID BLOCKING - PROVIDE MIN. ONE PER FLOOR IN HALL AS
INDICATED AND MIN. ONE IN EACH BEDROOM.
6" 42" X 86" FIXED
(TEMPERED).
42" X 86" FIXED
(TEMPERED). - PROVIDE ANY ADDITIONAL AS INDICATED ON PLANS.
8"
5.25"

W/ 42" X 21" AWN. W/ 42" X 21" AWN. - POWER- HARDWIRE AS ABOVE W/ BATTERY BACKUP.
3'-0"

(2) 2x12 RIM JOIST


GFI
GFI

TRANSOM FLITCH BEAM- TRANSOM


18'-8" FULL BEARING. (2) LVL
1'-8"

W13 W14
(5.5")
SOLID BLOCKING OVER WALL GAS-FIRED FIREPLACE
7'-11"
THIN BRICK AT
9'-0" 8'-4" 4'-3" - SEALED TEMPERED GLASS.
CHIMNEY.
- UL LISTING UL307B, ANSI Z21.88b-2008
2
x1

6"
)2
(2

10'-4" FIREPLACE SHALL BE:


(1) 2x12 LVL SUPERIOR 54 INCH DIRECT VENT
BEAM WITH CANTILEVER CONTEMPORARY LINEAR GAS FIREPLACE
MODEL DRL6554 OR EQUAL.
17'-2" - 4.5"/7" DIRECT VENT PER MFR. 66" FRAMING,
19'-11" 11'-5" 25'-3" 54" VIEWING AREA, INSTALL PER MFR. REQ'S,
PROVIDE ACCESS TO GAS VALVE.
25'-0"

1'-8"
9"
2'-6"

2'-9"
PITCH
1/4" = 1'-0"
+6"
+6"

PITCH
+6"

3/8" = 1'-0"

+4.5"
+1.5"

0"
0"

1'-8"
+6"

3'-0" 6'-6"
3/8" = 1'-0"
11'-5" PITCH

6'-6"
0"

9'-0"

25'-3"
CHIMNEY WALL.
UNIT TO INSIDE OF
(2) WALL MOUNT A/C
3/8" = 1'-0"
PITCH
+ 7.5"

SEE PLANS, SECTIONS, AND ELEVATIONS


FOR ROOF DETAILS AND CONFIGURATION.
PITCH

BELOW
BELOW

@ 1/4"/FT.

OPEN TO
OPEN TO

4'-3"

RECESSED DRAIN- SEE DETAILS

25'-0"

BARRY M. BASHKER, R.A. THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY
BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
ARCHITECTURE/PLANNING FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY
PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
233 East Shore Rd, Suite 206 DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
Great Neck, New York 11023 RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED
TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
Phone: 516-570-6711 FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE
Cell: 917-608-8169 PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,
Email: [email protected] OR FOR COMPLETION OF THIS PROJECT BY OTHERS.
ARCHITECTURE PLLC Website: bmbarchitecture.com C 2021
AT PROJECTED EAVES:
CHIMNEY APPROVED
5" X 5" SQ. SMOOTH/
TYPE VENT

2'-0"
ALUMINUM CLADDING OVER
PLYWOOD AT HORIZONTAL
HEAVY DUTY/
ALUMINUM LEADER

1'-2"
FASCIA SURFACE.
- ALUMINUM SNAP ON COPING TO MATCH GUTTERS
AT TOP- SLOPE AT 1/2" PER FT. AND OVERHANGS.
TO EXTERIOR, DRIP EDGE,
PER DETAIL.

2'-0"
- SOLID AZEK SOFFITS, COLOR

3'-5"
1'-10"
AS SELECTED BY OWNER

6'-4"
WINDOW NOTE:

2'-0"

1'-1"
ALL WINDOWS SHOWN SHALL
1'-10" 1'-10"
3'-6"
BE ENERGY STAR, INSULATED PARAPET BEYOND
DOUBLE GLAZED WINDOWS BY
ANDERSON, A SERIES (COMP. 4'-3"
OVER WOOD) OR 400 SERIES
1'-1"

(VINYL OVER WOOD) AS


SELECTED BY OWNER. 1'-10" WOOD SIDING-
STAIN PER OWNER'S

1'-9"
WIDTH AND HEIGHT AS INDICATED
ON PLANS AND ELEVATIONS. SELECTION.
- TEMPERED GLASS IN SHOWERS,

12'-0"
@ SILLS LESS THAN 18", NEAR
STAIRS AS SHOWN, AND AS INDIC.

4'-6"
ON PLANS. TEMPERED GLASS,

6'-0"
9'-0"

STAINLESS STEEL
PROVIDE COPPER FLASHING RAIL AND POSTS.

7'-0"
(12" UP) OVER ICE SHIELD
FLASHING (24" UP) ALL WALL
SURFACES ADJACENT TO

3'-2"

3'-3"
LOWER FLAT ROOFS, TYP.

1'-8"
2'-0"

1'-2"
1'-2"

TURN CONCEALED

1'-9"
SOLID AZEK SOFFITS, COLOR GUTTER AROUND
AS SELECTED BY OWNER CORNER AS SHOWN.
1'-10"
4'-3 1/2"

9'-6"
REVEAL

OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,


TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY

RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED


PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY

FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE


PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
7'-0"
3 COAT CEMENTITIOUS

C 2021
T/ FOUNDATION WALL
@ 16" BELOW T/ FIN. FIRST FLOOR STUCCO, COLOR AND
FINISH PER OWNER'S
SELECTION
4"

OR FOR COMPLETION OF THIS PROJECT BY OTHERS.


1'-10"

1'-10"
1'-7"

T/GAR.
4"
1'-11"

REVERSE BRICK SHELF FOR GARAGE SLAB


(6" WIDE X 7" DEEP) (8'-3" FROM BTM.
4'-0"

3'-6"
STEP GARAGE FOOTING DOWN PLANTER-BEHIND OF CELLAR JSTS.

FIN. HDRM.
THIN BRICK VENEER

8'-1"

8'-1"
AT 1 VERT. TO 2 HORIZ. BACK TO TOP OF SLAB)
TO HOUSE, TYPICAL. BELOW WINDOW
EL. 46.83'

1'-6"
BEYOND-

3'-7"
6'-4"

2'-0"
3'-6"

T/PLTFM.

917-608-8169
516-570-6711

[email protected]
BARRY M. BASHKER, R.A.

11023
233 East Shore Rd, Suite 206
ARCHITECTURE/PLANNING

bmbarchitecture.com
1'-1"

1'-10" 1'-10" 1'-10"


2ND CLG.
WOOD SIDING-

Great Neck, New York


STAIN PER OWNER'S DOOR NOTE-
LEADER
2'-0"

SELECTION. TEMPERED-DOUBLE GLASS,


BEYOND TEMPERED
PROVIDE COPPER FLASHING INSULATED FIBERGLASS
(12" UP) OVER ICE SHIELD FRONT DOOR BY OWNER. PLANTER NOTE-
6'-0"
9'-0"

FLASHING (24" UP) ALL WALL - CUSTOM INSULATED-DOUBLE PLANTER PART OF LANDSCAPING,
SURFACES ADJACENT TO GLAZED GLASS SIDE LITES AND PROVIDE 24" DEEP, TAPERED

Website:
3 COAT CEMENTITIOUS LOWER FLAT ROOFS, TYP. TRANSOM, MINIMAL MULLIONS,

Phone:
FOUNDATION AT RETAINING WALLS,

Email:
STUCCO, COLOR AND

Cell:
BY GLAZER. 8" WIDE AT BOTTOM, REINFORCED
29'-10"

FINISH PER OWNER'S - MATCHING FINISH INSULATED CONCRETE WITH #3 @ 8" O.C. BOTH
SELECTION FIBERGLASS GARAGE DOOR, WAYS ALL AROUND.
1'-8"

BRUSHED STEEL FINISH HARD. MATCHING BRICK TO BLDG. VENEER.

ARCHITECTURE PLLC
T/2ND FL.
2'-0"
1'-2"

1ST CLG.
1'-10"
1'-9"

GARAGE INSULATION NOTE-


1'-10" PROVIDE MINIMUM R-19 INSUL.
AT GARAGE CEILING BELOW
CONDITIONED SPACE ABOVE.

REVEAL
FILL ABOVE GARAGE
DOOR, ALUM. FINISH
9'-6"

2'-0"
THIN BRICK
7'-0"

TEMPERED TEMPERED EXTERIOR TYPE,


8'-1"

VENEER ANODIZED ALUMINUM UP AND


DOWN LIGHT BY OWNER. 8"

GRADE ELEVATION= 17.75'


4"

T/1ST FL. T/1ST FL. (EL. 19.66')


AVERAGE CENTERLINE OF GRADE OF
1'-7"
1'-10"

1'-10"

STREET @ FRONT OF PROPERTY=


2'-8"

T/GAR. (16.45' + 17.53')/2 = 17.0' EL.

1'-10 1/2" 7'-0" 1'-10 1/2" 6'-0" 1'-8" 7'-11" 1'-8"


1'-10"

5" X 5" SQ. SMOOTH/


HEAVY DUTY/

2'-0"
ALUMINUM LEADER
TO MATCH GUTTERS

3'-6"
AND OVERHANGS. 5'-0" MATERIAL CHANGE

2'-0"
1'-1"

1'-10"

3'-5"
MASTER
BDRM. CLG. T/PLTFM.

1'-1"
ALIGN TOPS 1'-10"

1'-9"
3'-0" 2ND CLG.
(ALIGN WITH DOOR
TRANSOM AS POSSIBLE)

2'-0"
12'-0"

TEMPERED

4'-6"
10'-2"

6'-0"

6'-0"
EQ. EQ.

8'-0"

5'-8"
3'-2"
3'-3"

1'-8"

1'-8"
T/2ND FL.
1'-2"

1ST CLG.

1'-9"
REVEAL

VERIFY DIRECTION OF
CASEMENT WINDOW SWINGS
WITH OWNER. PROVIDE SHOP

4'-0"
4'-3" DRAWINGS FOR OWNERS
9'-6"

APPROVAL PRIOR TO CONSTR.

OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,


TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY

RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED


PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY

FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE


PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
9'-0"

TYPICAL

7'-6"
7'-0"

C 2021
TREATED

3'-6"
WOOD DECK
4"

T/1ST FL.

OR FOR COMPLETION OF THIS PROJECT BY OTHERS.


1'-10"

CLR. CLG.

2'-8"
1'-10"

FIN. HDRM.
8'-1"
(8'-3" FROM BTM.
OF CELLAR JSTS.

1'-0"
TO TOP OF SLAB)

2'-0"
LED SOFFIT LIGHTS-
CENTER IN SOFFIT

917-608-8169
516-570-6711

[email protected]
BARRY M. BASHKER, R.A.

11023
233 East Shore Rd, Suite 206
ARCHITECTURE/PLANNING

bmbarchitecture.com
1'-10"
5"

MASTER
1'-10"
1'-9"

BDRM. CLG.

Great Neck, New York


1'-9" OPERABLE
TRANSOM
WINDOW NOTES:
8'-0" HIGH
TEMPERED SLIDING TEMPERED 1) ALL WINDOWS SHOWN SHALL BE ENERGY STAR,
REVEAL IN ALUMINUM
10'-2"

GLASS DOORS.
PANEL- ALIGN WITH INSULATED DOUBLE GLAZED WINDOWS BY:

Website:
TOP OF DOOR. ANDERSON, A SERIES (COMP. OVER WOOD) OR

Phone:

Email:
8'-0"

400 SERIES (VINYL OVER WOOD)

Cell:
AS SELECTED BY OWNER.

2) WIDTH AND HEIGHT AS INDICATED ON PLANS


3'-3"

AND ELEVATIONS.

ARCHITECTURE PLLC
- TEMPERED GLASS IN SHOWERS,
T/2ND FL. - TEMPERED GLASS AT ALL DOORS,
- TEMPERED GLASS AT ALL SILLS
1'-2"

LESS THAN 18",


- TEMPERED GLASS AT STAIRS AS
1ST CLG.
6"

6" ABOVE DOORS +/- SHOWN AND AS INDICATED.


CHIMNEY BEYOND

AS REQ'D FOR DOOR


MOTOR, VERIFY W/ 3) ALL WINDOWS INDICATED TO BE EGRESS SHALL
GARAGE BEYOND

MFR. BE CERTIFIED EGRESS WINDOWS (BY MFR.)


9'-0" HIGH (+/-)
TREATED
WITH APP'D TYPE HARDWARE, OPENABLE
TEMPERED SLIDING WITHOUT A KEY.
WOOD DECK
GLASS DOORS.
9'-6"

4) CONTRACTOR TO PROVIDE SHOP DRAWINGS TO


9'-0"

ARCHITECT FOR APPROVAL PRIOR TO FABRICATION.


TEMPERED
5) DOOR AND WINDOW SUPPLIER/VENDOR SHALL BE
RESPONSIBLE TO VERIFY THAT ALL EGRESS AND
PLANTER BEYOND WINDOWS REQUIRED TO BE TEMPERED SHALL MEET
CODE REQUIREMENTS. SEE EGRESS WINDOW NOTES.
T/1ST FL.
6) SEE DRAWINGS AND RES-CHECK FOR MINIMUM INSUL.
VALUE OF WINDOWS AND DOORS.
STAIR NOTE-
2'-0"

R311.5.1 - MIN. WIDTH = 36"


3'-3"

R311.5.2 - MIN. HEADROOM = 6'-8"


1'-2" 1'-2" 1'-1"

OF A 4" SPHERE., TYPICAL.


8'-1" 9'-6" 9'-0"

R311.5.3.2 - MIN. TREAD DEPTH = 9"


6'-4"

R311.5.6 - AT LEAST ONE HANDRAIL AT


R311.5.3.1 - MAX. RISER HEIGHT = 8 1/4"

SHALL NOT PERMIT THE PASSAGE


R312 - STAIR AND GUARDRAIL BALUSTERS
STAIRS WITH 4 OR MORE RISERS
6"

4'-3"

STAIRWAY SHALL COMPLY WITH THE FOLLOWING:


SEE PLAN
4'-3"

SHOWN
RISER AS

FLOOR CONSTRUCTION
TREAD
AS SHOWN
3'-6"

4" MAX.
2'-10"
11'-2"

EQ.
1'-2"
7'-0"

AT TOP) PER CODE.


IN LIEU OF BALUSTERS,
10'-2"

WOOD TOP RAIL CONNECTED TO


OF TEMPERED/LAMINATED SAFETY
GUARDRAIL MAY BE CONSTRUCTED

BALUSTERS, PER MFR. AS REQUIRED


TO COMPLY W/LATERAL LOAD (200 LB.
PER GLASS PANEL, PROVIDE METAL OR
GLASS PER R308.4.4, MIN. 3 BALUSTERS
2'-0"

3'-6" 3'-6"

EQ.
1'-10"

3'-0"

2'-8" 3'-0" 3'-0"

2'-0"
2'-8"

3'-0"

7'-0"

1'-8" 6'-0" 1'-4" +/-

1'-2"

1'-4"
1'-0"

1'-2"
1'-0"
1'-10"

6"
2'
-4
"

12" 2'-0"
3"
1'-0"

11"
GLUE

1'-10"

11"

9'-0"
(16.45' + 17.53')/2 = 17.0' EL.

1'-2" 1'-1" 3'-6"


EL. 17.0'

5"

2'-8"
STREET @ FRONT OF PROPERTY=
AVERAGE CENTERLINE OF GRADE OF

1'-0"

29'-10"

11"

BARRY M. BASHKER, R.A. THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY
BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
ARCHITECTURE/PLANNING FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY
PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
233 East Shore Rd, Suite 206 DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
Great Neck, New York 11023 RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED
TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
Phone: 516-570-6711 FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE
Cell: 917-608-8169 PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,
Email: [email protected] OR FOR COMPLETION OF THIS PROJECT BY OTHERS.
ARCHITECTURE PLLC Website: bmbarchitecture.com C 2021
3'-6"
6'-4"

2'-0"
3'-6"
1'-1"

1'-8"

1'-10"

10'-2"
9'-0"

9'-0"
1'-5"
1'-2"
9'-6"

FLOOR JOISTS PER PLANS

8'-1"

CELLAR PARTITION NOTE-

ALL PARTITIONS WITHIN CELLAR SHALL


BE 1-5/8" X 3-5/8 20GA GALVANIZED
METAL STUDS AT 16" O.C. ON HEAVY
GAUGE GALVANIZED METAL TRACK
SECURED TO SLAB WITH POWDER
ACTUATED FASTNERS (PROVIDE SLIP
SHEET BELOW ALL TRACKS).

MAINTAIN 2" AIR SPACE BETWEEN


STUD WALLS AND FOUNDATION, U.O.N.

MOLD AND MOISTURE RESISTANT GYP.


PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS WALL BOARD AT ALL WALLS. ALL
NAILING SCHEDULE PER WFCM TABLE 3.1 TO COMPLY WITH N.Y.S. 2020 ENERGY CODE, TABLE 402.1.2 WALL BOARD TO BE 5/8" FIRE-RATED
TYPE X.

USE 5/8" CEMENT BOARD AT BOTTOM


4" OF ALL PARTITIONS. VERIFY BASE
HEIGHT WITH OWNER.

SPECIFIED FINISHED FLOOR OVER


3
4" THICK PLYWOOD SUBFLOOR 5/8" DIA. ANCHOR BOLTS AT 10" LONG @ 32" O.C.
SPACING WITHIN 12" OF CORNERS FASTENED WITH
FLOOR JOISTS PER PLANS 1/2" x 3" BEARING PLATE & SQUARE THREADED BOLT

DOUBLE TREATED WOOD SILL PLATE


OVER COPPER OR OTHER APPROVED
METAL TERMITE SHIELD.

(2) HORIZ. REBAR @ TOP


& BOTTOM,
PITCHTYPICAL
AWAY @ 1/4"
PER FOOT MINIMUM-
SOUND INSULATION: U.O.N.
UNFACED, FIREPROOF MINERAL WOOL
GRADE
SOUND INSLUATION THROUGHOUT @
EACH FLOOR, THICKNESS PER OWNER,
USE IC RATED RECESSED LIGHTING,
TYPICAL.

R15 BATTS INSULATION FROM 4"


ABOVE SLAB TO CEILING

FOUNDATION WATERPROOFING:
PROVIDE ADHERED BITUM. WATERPROOFING
MEMBRANE BITUTHENE 3000 OR EQUAL, FROM TOP
OF FOUNDATION WALL DOWN TO TOP OF FOOTING.
3"
- PROTECT WITH 2" RIGID INSULATION PRIOR TO
BACKFILLING, R10 7"
12" THK 4000 PSI CONC. FOUNDATION WALL
#4 REBAR @ 12" O.C. BOTH WAYS-
VERTICALLY AND HORIZONTALLY

24" WIDE X 12" H 3500 PSI CONC. FTG.


(3) #4 REBAR CONTINUOUS AT BOTTOM-
#4 @ 18" O.C. OTHER WAY FLASH JOINT BTWN WALL
& FTG. WITH MEMBRANE,
BLUESKIN OR EQ.
NEW 5" SLAB ON GRADE WITH WWM 6-6/6X6
ON 15 MIL WATERPROOFING MEMBRANE
OVER 6" GRAVEL OR WELL DRAINING SOIL/SAND. USE WELL DRAINING
SOIL BACKFILL, typ.

3
4 " STONE / GRAVEL

4" PERFORATED HEAVY GUAGE


(GREEN) PVC PIPING WITH HEAVY
2" RIGID INSULATION GUAGE FILTER FABRIC ALL AROUND PIPE.
BELOW SLAB
MINIMUM 24" ALL AROUND FRENCH DRAIN AT INTERIOR, TYPICAL:
EXTERIOR PERIMETER.
SUMP PUMPS AS
INDICATED ON PLAN.

BARRY M. BASHKER, R.A. THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY
BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
ARCHITECTURE/PLANNING FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY
PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
233 East Shore Rd, Suite 206 DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
Great Neck, New York 11023 RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED
TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
Phone: 516-570-6711 FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE
Cell: 917-608-8169 PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,
Email: [email protected] OR FOR COMPLETION OF THIS PROJECT BY OTHERS.
ARCHITECTURE PLLC Website: bmbarchitecture.com C 2021
STEP FOOTING DETAIL

THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY


BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY
PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED
TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE
PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,
OR FOR COMPLETION OF THIS PROJECT BY OTHERS. C 2019
THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY
BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY
PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED
TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE
PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,
OR FOR COMPLETION OF THIS PROJECT BY OTHERS. C 2019
PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS
TO COMPLY WITH N.Y.S. ENERGY CODE, TABLE 402.1.2
SECTION 402 BUILDING THERMAL ENVELOPE: SECTION 403 SYSTEMS (MANDATORY)
1. ALL JOINTS, SEAMS AND PENETRATIONS. PER 402.4.2.1 TESTING . OPTION. BUILDING ENVELOPE TIGHTNESS AND
2. SITE-BUILT WINDOWS, DOORS AND SKYLIGHTS. INSULATION
THE BUILDING INSTALLATION
OR DWELLING SHALL BESHALL
UNIT CONSIDERED ACCEPTABLE
BE TESTED WHEN
AND VERIFIED 403.1 CONTROLS. AT LEAST ONE THERMOSTAT SHALL BE PROVIDED FOR EACH
PER 402.1 BUILDING THERMAL ENVELOPE SHALL MEET NYSECCC PRESCRIPTIVE TESTED AIR AN
LEAKAGE IS LESSRATE
THANNOTSEVEN AIR CHANGES SEPARATE HEATING AND COOLING SYSTEM.
3. OPENINGS BETWEEN WINDOW AND DOOR AS HAVING AIR LEAKAGE EXCEEDING THREEPER AIR HOUR
REQUIREMENTS.
ASSEMBLIES AND THEIR RESPECTIVE JAMBS AND
(ACH)
CHANGESWHENPER TESTED
HOUR.WITH A BLOWER
TESTING SHALLDOOR AT A PRESSURE
BE CONDUCTED IN OF 1.0 PSF PER 403.1.1 PROGRAMMABLE THERMOSTAT, EACH DWELLING UNIT SHALL
FRAMING.
(50 PA) AS VERIFIED
ACCORDANCE WITH USING
ASTM E INSTRUMENTS
779 OR ASTM AND PROCEDURES
E 1827 SPECIFIED
AND REPORTED HAVE AT LEAST ONE THERMOSTAT CAPABLE OF AUTOMATICALLY ADJUSTING
PER 402.1.1 CLIMATE ZONE 4 REQUIREMENTS SHALL BE MET.
AT ASHRAE/ASTM
IN A PRESSURE OF 0.2 E779.
INCHTW.G.
HE TEST SHALL BEWHERE
(50 PASCALS). CONDUCTED BY A
REQUIRED THE SPACE TEMPERATURE SET POINT OF THE LARGEST HEATING OR
4. UTILITY PENETRATIONS.
PER TABLE 402.1.1 INSULATION AND FENESTRATION COMPONENTS QUALIFIED
BY THE CODEPERSON , WHOTESTING
OFFICIAL, SHALL DEMONSTRATE COMPETENCE
SHALL BE CONDUCTED TO THE
BY AN COOLING ZONE AND CAPABLE OF CONTROLLING THE HEATING AND COOLING
SHALL MEET TABLE REQUIREMENTS FOR CLIMATE ZONE 4.
5. DROPPED CEILINGS OR CHASES ADJACENT TO SATISFACTION OF THE CODEAENFORCEMENT OFFICIAL SYSTEM ON A DAILY SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SET
APPROVED THIRD PARTY. WRITTEN REPORT OF FOR
THE THE CONDUCT
RESULTS
THE THERMAL ENVELOPE. . FORBE , ACH50THE POINTS AT DIFFERENT TIMES OF THE DAY. THIS THERMOSTAT SHALL
SEE ATTACHED TABLE. OF
OF SUCH TESTS
THE TEST SHALL THE PURPOSE
SIGNED OF THIS
BY THE PARTYSECTION
CONDUCTING SHALL
6. KNEE WALLS. MEAN AIR PROVIDED
TEST AND CHANGES PER HOUR
TO THE OF OFFICIAL.
CODE INFILTRATION INTO A
TESTING HOUSE
SHALL BE AS
INCLUDE THE CAPABILITY TO SET BACK OR TEMPORARILY OPERATE THE
PER 402.1.2 USE MANUFACTURER’S R-VALUE FOR ALL INSULATION. 7. WALLS AND CEILINGS SEPARATING A GARAGE MEASURED WITH A BLOWER AT 50 PASCALS
DOOR CREATING PRESSURE, IN
SYSTEM TO MAINTAIN ZONE TEMPERATURES DOWN TO 55°F (13°C) OR UP
PERFORMED AT ANY TIME AFTER OF ALLOFPENETRATIONS
COMPUTED R-VALUES DOES NOT INCLUDE R-VALUE FOR TO 85°F (29°C). THE THERMOSTAT SHALL INITIALLY BE PROGRAMMED WITH
FROM CONDITIONED SPACES. ACCORDANCE
OF THE BUILDING ASHRAE/ASTM
WITHTHERMAL ENVELOPE. E779. TESTING SHALL OCCUR
OTHER BUILDING MATERIALS OR AIR FILMS. A HEATING TEMPERATURE SET POINT NO HIGHER THAN 70°F (21°C) AND A
8. BEHIND TUBS AND SHOWERS ON EXTERIOR AFTER ROUGH IN AND AFTER INSTALLATION OF PENETRATIONS OF THE
COOLING TEMPERATURE SET POINT NO LOWER THAN 78°F (26°C).
402.1.3 N/A, U-FACTOR ALTERNATIVE NOT USED. WALLS. BUILDING ENVELOPE, INCLUDING PENETRATIONS FOR UTILITIES,
PLUMBING, ELECTRICAL, VENTILATION PER 403.1.2 HEAT PUMP SUPPLEMENTARY HEAT, HEAT PUMPS HAVING
9. COMMON WALLS BETWEEN DWELLING UNITS. SUPPLEMENTARY ELECTRIC-RESISTANCE HEAT SHALL HAVE CONTROLS THAT,
402.1.4 N/A, TOTAL UA ALTERNATIVE NOT USED. AND COMBUSTION APPLIANCES.
10. ATTIC ACCESS OPENINGS. EXCEPT DURING DEFROST, PREVENT SUPPLEMENTAL HEAT OPERATION WHEN
402.1.5 N/A, EXTERIOR SIDING NOT PROPOSED. 11. RIM JOIST JUNCTIONS. THE HEAT PUMP COMPRESSOR CAN MEET THE HEATING LOAD.
N.Y.S. ENERGY CONSERVATION CODE
DURING TESTING:
12. SILL PLATES AND HEADERS. FOAM PLASTIC 1. EXTERIOR WINDOWS AND DOORS, FIREPLACE AND STOVE
GENERAL REQUIREMENTS
402.2 SPECIFIC INSULATION REQUIREMENTS (PRESCRIPTIVE). (SPRAY FOAM INSULATION) SHALL BE PERMITTED 403.2 DUCTS.
DOORS SHALL BE CLOSED, BUT NOT SEALED; 403.3
TO BE SPRAY APPLIED TO A SILL PLATE, HEADER, 1. ALL WORK SHALL CONFORM TO N.Y.S. ENERGY CONSERVATION CONSTRUCTION CODE PUBLISHED
402.2.1 N/A, PROVIDE R-49
R-38 IN ALL CEILINGS INCLUDING CATHEDRAL CEILINGS, 2. DAMPERS SHALL BE CLOSED, BUT NOT SEALED, INCLUDING 2020 AND SHALL MEET BUT NOT BE LIMITED TO CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY
AND RIM JOISTS WITHOUT THE THERMAL BARRIER PER 403.3.1
403.2.1 INSULATION, SUPPLY DUCTS IN ATTICS SHALL BE INSULATED TO A
EXTEND OVER THE WALL TOP PLATE AT THE EAVES. EXHAUST, INTAKE, MAKEUP AIR, BACKDRAFT AND FLUE BY THERMAL ENVELOPE PRESCRIPTIVE FORMULA.
AS SPECIFIED IN THE RESIDENTIAL CODE OF MINIMUM OF R-8. ALL OTHER DUCTS SHALL BE INSULATED TO A MINIMUM OF R-6.
DAMPERS; EXCEPTION: DUCTS OR PORTIONS THEREOF LOCATED COMPLETELY INSIDE THE 2. DESIGN VALUES: 4910 HEATING DEGREE DAYS (NASSAU COUNTY, ZONE 4A)- ZONE 4
402.2.1.1 N/A, ALL ATTIC ASSEMBLIES TO BE VENTED UNLESS THE UNVENTED NEW YORK STATE, SECTION 314.4 SUBJECT TO 3. INTERIOR DOORS SHALL BE OPEN; 13d F WINTER DESIGN DRY BULB TEMPERATURE
BUILDING THERMAL ENVELOPE.
ATTIC SPACE IS COMPLETELY CONTAINED WITHIN THE BUILDING ALL OF THE FOLLOWING: 4. EXTERIOR OPENINGS FOR CONTINUOUS VENTILATION
89d F. SUMMER DESIGN DRY BULB TEMPERATURE

THERMAL ENVELOPE. A. THE MAXIMUM THICKNESS OF THE FOAM PER 403.3.2


403.2.2 SEALING, ALL DUCTS, AIR HANDLERS, FILTER BOXES AND BUILDING 3. INSULATION SHALL BE INSTALLED IN A MANNER THAT PROVIDES CONTINUITY OF INSULATION AT
SYSTEMS AND HEAT RECOVERY VENTILATORS SHALL BE
1 CAVITIES USED AS DUCTS SHALL BE SEALED. JOINTS AND SEAMS SHALL COMPLY
PLASTIC SHALL BE 3 /4 INCHES (83 CLOSED AND SEALED; PLATE LINES, SILL LINES & CORNERS.
TABLE 402.2.1.1 INSULATION FOR CONDENSATION CONTROL MM).
WITH SECTION M1601.3.1 OF THE RESIDENTIAL CODE OF NEW YORK STATE,
5. HEATING AND COOLING SYSTEM(S) SHALL BE TURNED OFF; OR, IN NEW YORK CITY, THE NEW YORK CITY CONSTRUCTION CODES. DUCT
4. ALL INSULATION WHICH IS CAPABLE OF ABSORBING WATER SHALL BE PROTECTED BY A VAPOR
MINIMUM RIGID BOARD OR B. THE DENSITY OF THE FOAM PLASTIC 6. HVAC DUCTS SHALL NOT BE SEALED; AND BARRIER LOCATED ON THE WINTER WARM SIDE OF THE INSULATION.
TIGHTNESS SHALL BE VERIFIED BY EITHER OF THE FOLLOWING:
AIR-IMPERMEABLE SHALL BE IN THE RANGE OF 0.5 TO 2.0 7. SUPPLY AND RETURN REGISTERS SHALL NOT BE SEALED. 5. RECESSED LIGHT FIXTURES SHALL MEET THE BASIC REQUIREMENTS OF NYS ECCC, AND COMPLY
A
CLIMATE ZONE INSULATION R-VALUE POUNDS PER CUBIC FOOT (8 TO 32 WITH SECT. 402.4.3 AND ALL APPLICABLE SEALING METHODS.
3
KG/M ). 1. POST CONSTRUCTION TEST: LEAKAGE TO OUTDOORS SHALL
4 R-15 TEST RESULTS SHALL BE PROVIDED TO THE CODE
BE LESS THAN OR EQUAL TO 8 CFM (226.5 L/MIN) PER 100 6. EXTERIOR JOINTS AROUND THE WINDOWS & EXTERIOR DOOR FRAMES, OPENINGS BETWEEN WALLS
. T
C HE FOAM PLASTIC SHALL HAVE A FLAME ENFORCEMENT OFFICIAL AND SHALL INCLUDE: 2 2 AND ROOF/ CEILLINGS AND BETWEEN WALL PANELS, OPENINGS AT PENETRATIONS OF UTILITY
FT (9.29 M ) OF CONDITIONED FLOOR AREA OR A TOTAL
SPREAD INDEX OF 25 OR LESS AND AN A. NAME AND PLACE OF BUSINESS OF THE TESTER; SERVICES THROUGH WALLS FLOORS AND ROOFS AND ALL OTHER SUCH OPENINGS IN BUILDING
LEAKAGE LESS THAN OR EQUAL TO 12 CFM (12 L/MIN) PER
ACCOMPANYING SMOKE DEVELOPED B. ADDRESS OF THE BUILDING WHICH WAS TESTED; 100 FT2 (9.29 M2) OF CONDITIONED FLOOR AREA WHEN PERIMETER SHALL BE CAULKED, GASKETED, WEATHERSTRIPPED OR OTHERWISE SEALED.
INDEX OF 450 OR LESS WHEN TESTED C. CONDITIONED FLOOR AREA OF DWELLING, CALCULATED IN TESTED AT A PRESSURE DIFFERENTIAL OF 0.1 INCHES W .G. 7. ALL EXTERIOR DOORS AND WINDOWS SHALL BE DESIGNED TO LIMIT AIR LEAKAGE INTO OR OUT
IN ACCORDANCE WITH ASTM E 84. ACCORDANCE WITH ANSI Z65-1996, EXCEPT THAT (25 PA) ACROSS THE ENTIRE SYSTEM, INCLUDING THE
402.2.2 N/A, THERE ARE NO EXISTING CEILING/ROOF ASSEMBLIES WITHOUT OF THE BUILDING. FOR DOORS, THERMAL TRANSMITTANCE MAY NOT EXCEED U OF 35;
13. OTHER SOURCES OF INFILTRATION CONDITIONED FLOOR AREA SHALL INCLUDE AREAS WHERE MANUFACTURER’S AIR HANDLER ENCLOSURE. ALL REGISTER
ATTIC SPACES (INCLUDES CATHEDRAL CEILINGS). INFILTRATION LOSS FOR ENTRANCE DOORS SHALL NOT EXCEED (A) FOR SWINGING DOORS
THE CEILING HEIGHT IS LESS THAN 5 FEET (1524 MM); BOOTS SHALL BE TAPED OR OTHERWISE SEALED DURING THE
0.5 CFM PER. SQ. FT. OF DOOR AREA (B) FOR SLIDING DOORS 0.3 CFM PER SQ. FT. OF DOOR
PER 402.2.3 ALL ACCESS HATCHES AND DOORS FROM CONDITIONED SPACES 402.4.2 COMPIANCE DEMONSTRATION. TEST.
D. MEASUREMENT OF ACH50; AND
8. DOMESTIC HOT WATER SHALL COMPLY WITH REQUIREMENTS OF CLASS ONE WATER HEATERS AND
TO UNCONDITIONED SPACES SHALL BE WEATHERSTRIPPED AND E. CERTIFICATION OF ACCURACY OF TEST RESULTS AND
THE BUILDING DUCT AND PLENUM SYSTEM SHALL MEET THE REQUIREMENTS WATER TEMPERATURE SHALL BE 140d F. STORAGE TANK TO BE INSULATED WITH MIN. R-2
INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE PER 402.4.2 BUILDING ENVELOPE AIR TIGHTNESS AND INSULATION INSTALLATION SIGNATURE OF TESTER. ABOVE AS VERIFIED USING INSTRUMENTS AND PROCEDURES SPECIFIED IN
SURROUNDING SURFACES. SHALL BE DEMONSTRATED TO COMPLY WITH ONE OF THE FOLLOWING
ANSI/ASHRAE 152 AND ASTM E1554 TEST METHOD A. TESTS AT OTHER 9. HVAC EQUIPMENT SHALL MEET THE FOLLOWING REQUIREMENTS:
OPTIONS GIVEN BY SECTION 402.4.2.1 OR 402.4.2.2: (OWNER SHALL PER 402.4.2
402.4.2.2FIREPLACES.
VISUAL INSPECTION
NEW OPTION, BUILDINGFIREPLACES
WOOD-BURNING SHALL HAVE
ENVELOPE TIGHTNESS TEST PRESSURES ARE PERMITTED TO BE USED IF THEY ARE CONVERTED TO A) HVAC EQUIPMENT PERFOMANCE SHALL BE CERTIFIED BY THE MANUFACTURER FOR
402.2.4 N/A, NO MASS WALLS PROPOSED. RETAIN QUALIFIED INSPECTOR TO INSPECT OR TEST INSTALLED TIGHT-FITTING FLUE DAMPERS OR DOORS,
AND INSULATION INSTALLATION SHALL BE AND OUTDOOR
CONSIDERED COMBUSTION
ACCEPTABLE EQUIVALENT LEAKAGE AT 25 PASCALS (PA) OF PRESSURE, AND SUCH CONFORMANCE WITH CHAPTER 4 OF N.Y.S. ENERGY CONSERVATION CODE.
COMPONENTS.) AIR. WHERE USING TIGHT-FITTING DOORS ON FACTORY-BUILT FIREPLACES
WHEN THE ITEMS LISTED IN TABLE 402.4.2, APPLICABLE TO THE METHOD EQUIVALENCE IS DEMONSTRATED TO THE SATISFACTION OF THE CODE 10. ALL WATER DISTRIBUTION AND SANITARY DRAINAGE PIPING INSTALLED IN UNHEATED
PER 402.2.8 SLAB-ON-GRADE FLOORS. SLAB-ON-GRADE FLOORS WITH A FLOOR LISTED AND LABELED IN ACCORDANCE WITH UL 127, THE DOORS SHALL BE
ENFORCEMENT OFFICIAL. THE TEST SHALL BE CONDUCTED BY A QUALIFIED
TESTED AND LISTED FOR THE FIREPLACE. WHERE USING TIGHT-FITTING SPACES WITHIN THE BUILDING SHALL BE THERMALLY INSULTED IN ACCORDANCE WITH CHAPTER 4.
SURFACE LESS THAN 12 INCHES (305 MM) BELOW GRADE SHALL DOORSFON MASONRYAIR FIREPLACES, THE DOORS SHALL BEAND
LISTED AND PERSON, WHO SHALL DEMONSTRATE COMPETENCE TO THE SATISFACTION OF THE
BE INSULATED IN ACCORDANCE WITH TABLE 402.1.2.
402.1.1. THE PER 402.4.4 ENESTRATION LEAKAGE, W INDOWS , SKYLIGHTS SLIDING
CODE ENFORCEMENT OFFICIAL FOR THE CONDUCT OF SUCH TESTS. FOR THE 11. ALL ELECTRICAL EQUIPMENT AND LIGHTING EQUIPMENT SHALL COMPLY WITH SECT. 404.
LABELED IN ACCORDANCE WITH UL 907.
GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE THAN PURPOSE OF THIS SECTION CFM25 SHALL MEAN THE LEAKAGE FROM ALL DUCTS
INSULATION SHALL EXTEND DOWNWARD FROM THE TOP OF THE TABLE 402.4.1.1
TABLE 402.4.2 AIR BARRIER
AIR AND
BARRIER INSULATION
AND INSPECTION
INSULATION COMPONENT
INSPECTION CRITERIA
COMPONENT CRITERIA
SLAB ON THE OUTSIDE OR INSIDE OF THE FOUNDATION WALL.
PER 402.4.3
0.3 CFMFENESTRATION
PER SQUARE FOOTAIR L/S/M2), AND
(1.5LEAKAGE. WINDOWS,
SWINGINGSKYLIGHTS,
DOORS NO AND AND PLENUMS IN CUBIC FEET PER MINUTE MEASURED AT 25 PASCALS OF 12. THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PREPARED BY OR UNDER THE DIRECTION
INSULATION LOCATED BELOW GRADE SHALL BE EXTENDED THE
COMPONENT CRITERIA SLIDING GLASS
MORE THAN 0.5DOORS
CFM PER SHALL HAVEFOOT
SQUARE AN AIR L/S/M2), WHEN
(2.6INFILTRATION RATE OF NO
TESTED PRESSURE IN ACCORDANCE WITH ANSI/ASHRAE 152 OR ASTM E1554. TEST OF THE UNDERSIGNED AND TO THE BEST OF THE UNDERSIGNED'S KNOWLEDGE, INFORMATION
EXTERIOR THERMAL ENVELOPE INSULATION FOR FRAMED WALLS IS MORE THAN 0.3 CFM PER SQUARE FOOT (1.5 L/S/M²), AND SWINGING AND BELIEF MEET THE REQUIREMENTS OF THE N.Y.S. ENERGY CONSERVATION CODE 2020.
ACCORDING TO NFRC 400 CFM
THAN 0.5OR
AAMA/WDMA/CSA 101/I.S.2/A440 BY RESULTS SHALL BE PROVIDED TO THE CODE ENFORCEMENT OFFICIAL AND SHALL
DISTANCE PROVIDED IN TABLE 402.1.2
402.1.1 BY ANY COMBINATION OF INSTALLED IN SUBSTANTIAL CONTACT AND CONTINUOUS ALIGNMENT
DOORS NO MORE PER SQUARE FOOT (2.6 L/S/M²), WHEN
AN ACCREDITED
TESTED , INDEPENDENT
ACCORDING TO NFRC LABORATORY AND LISTED AND
400 OR AAMA/WDMA/CSA LABELED
101/I.S.2/A440 INCLUDE: 13. CONTRACTOR TO COORDINATE ALL REQUIRED INSPECTIONS WITH BUILDING DEPT AND ARCHITECT,
VERTICAL INSULATION, INSULATION EXTENDING UNDER THE SLAB AIR BARRIER AND THERMAL WITH BUILDING ENVELOPE AIR BARRIER. AND PROVIDE ALL REQUIRED TESTING RESULTS AND DOCUMENTATION TO THE BUILDING OFFICIAL,
BY
BY AN ACCREDITED, INDEPENDENT
THE LABORATORY AND LISTED AND .
MANUFACTURER
OR INSULATION EXTENDING OUT FROM THE BUILDING. BARRIER BREAKS OR JOINTS IN THE AIR BARRIER ARE FILLED OR REPAIRED. LABELED BY THE MANUFACTURER. 1. NAME AND PLACE OF BUSINESS OF THE TESTER;
AS REQUESTED.
EXCEPTION: SITE-BUILT WINDOWS, SKYLIGHTS AND DOORS.
PER 402.2.9 INSULATE FLOORS ABOVE CRAWL SPACES AS INDICATED AIR-PERMEABLE INSULATION IS NOT USED AS A SEALING MATERIAL. 2. ADDRESS OF THE BUILDING WHICH WAS TESTED;
AIR-PERMEABLE INSULATION IS INSIDE OF AN AIR BARRIER. 402.5 N/A FOR ZONE 4. (MANDATORY). CLASS I OR II VAPOR RETARDERS ARE 3. CONDITIONED FLOOR AREA OF DWELLING,
PER 402.2.10 INSULATION SHALL NOT BE REQUIRED ON THE HORIZONTAL AIR BARRIER IN ANY DROPPED CEILING/SOFFIT IS SUBSTANTIALLY REQUIRED ON THE INTERIOR SIDE OF FRAME WALLS IN ZONES 5 AND 6 CALCULATED IN ACCORDANCE WITH ANSI Z65,
EXCEPT THAT CONDITIONED FLOOR AREA SHALL ARCHITECT RESPONSIBLE FOR PLANS:
PORTION OF THE FOUNDATION THAT SUPPORTS A MASONRY ALIGNED WITH INSULATION AND ANY GAPS ARE SEALED. FOR ALL ABOVE GRADE FRAMED WALLS, AND FLOORS AND CEILINGS
CEILING/ATTIC INCLUDE AREAS WHERE THE CEILING HEIGHT IS LESS
VENEER. ATTIC ACCESS (EXCEPT UNVENTED ATTIC), KNEE WALL DOOR, OR WHERE THE FRAMED CAVITY IS NOT VENTILATED TO ALLOW MOISTURE TO BARRY M. BASHKER, R.A.
THAN 5 FEET (1524 MM); 233 EAST SHORE ROAD, SUITE 206 7/13/21
DROP DOWN STAIR IS SEALED. ESCAPE.
402.2.11 N/A, NO THERMALLY ISOLATED SUNROOMS PROPOSED. 4. MEASUREMENT OF CFM25; AND GREAT NECK, NY 11023 SIGNATURE
CORNERS AND HEADERS ARE INSULATED.
WALLS PER 402.5.3 MINIMUM CLEAR AIR SPACES AND VENTED OPENINGS FOR 5. CERTIFICATION OF ACCURACY OF TEST RESULTS AND LICENSE #026962
402.2.12 N/A, NO TENANT SEPARATION WALLS PROPOSED. JUNCTION OF FOUNDATION AND SILL PLATE IS SEALED.
VENTED CLADDING. FOR THE PURPOSES OF THIS SECTION, VENTED SIGNATURE OF TESTER.
WINDOWS AND DOORS SPACE BETWEEN WINDOW/DOOR JAMBS AND FRAMING IS SEALED. SEAL
RIM JOISTS RIM JOISTS ARE INSULATED AND INCLUDE AN AIR BARRIER. CLADDING SHALL INCLUDE THE FOLLOWING MINIMUM CLEAR AIR PER 403.3.3
403.2.3 BUILDING CAVITIES, BUILDING FRAMING CAVITIES SHALL NOT BE
402.3 FENESTRATION (PRESCRIPTIVE). SPACES OR VENTED SIDING: USED AS SUPPLY DUCTS.
FLOORS (INCLUDING ABOVE- INSULATION IS INSTALLED TO MAINTAIN PERMANENT CONTACT WITH
GARAGE AND UNDERSIDE OF SUBFLOOR DECKING. 1. STUCCO WITH A 3/8-INCH (9.52 MM) CLEAR AIRSPACE WITH 3/8- PER 403.4
403.3 MECHANICAL SYSTEM PIPING INSULATION, MECHANICAL SYSTEM
PER 402.3.1 AN AREA-WEIGHTED AVERAGE OF FENESTRATION PRODUCTS CANTILEVERED FLOORS) AIR BARRIER IS INSTALLED AT ANY EXPOSED EDGE OF INSULATION. INCH (9.52 MM) CONTINUOUS SLOT VENT OPENINGS AT THE TOP
PIPING CAPABLE OF CARRYING FLUIDS ABOVE 105°F (41°C) OR BELOW 55°F
SHALL BE PERMITTED TO SATISFY THE U-FACTOR REQUIREMENTS. INSULATION IS PERMANENTLY ATTACHED TO WALLS. AND BOTTOM OF EACH WALL. (13°C) SHALL BE INSULATED TO A MINIMUM OF R-3.
CRAWL SPACE WALLS EXPOSED EARTH IN UNVENTED CRAWL SPACES IS COVERED WITH 2. BRICK WITH A 2-INCH (51 MM) CLEAR AIRSPACE BEHIND THE
402.3.2 UP TO 15 SQUARE FEET (1.4 M2) OF GLAZED FENESTRATION PER
PER 402.3.3 PER 403.5
403.4 CIRCULATING HOT WATER SYSTEMS, ALL CIRCULATING SERVICE HOT
CLASS I VAPOR RETARDER WITH OVERLAPPING JOINTS TAPED. BRICK WITH VENTS AT BOTH THE TOP AND BOTTOM OF THE
DWELLING UNIT SHALL BE PERMITTED TO BE EXEMPT FROM U- 3 WATER PIPING SHALL BE INSULATED TO AT LEAST R-2. CIRCULATING HOT
DUCT SHAFTS, UTILITY PENETRATIONS, KNEE WALLS AND FLUE SHAFTS BRICK. THE VENTS SHALL BE /8 INCH × 2.5-INCH (9.52 MM ×
FACTOR REQUIREMENTS IN SECTION 402.1.1.
402.1.2 SHAFTS, PENETRATIONS WATER SYSTEMS SHALL INCLUDE AN AUTOMATIC OR READILY ACCESSIBLE
OPENING TO EXTERIOR OR UNCONDITIONED SPACE ARE SEALED. 63 MM) OPENINGS EVERY 3RD BRICK @ BOTH THE BOT. AND MANUAL SWITCH THAT CAN TURN OFF THE HOT WATER CIRCULATING PUMP
PER 402.3.4
402.3.3 ONE SIDE-HINGED OPAQUE DOOR ASSEMBLY UP TO 24 SQUARE BATTS IN NARROW CAVITIES ARE CUT TO FIT, OR NARROW CAVITIES TOP. WHEN THE SYSTEM IS NOT IN USE.
2 NARROW CAVITIES
FEET (2.22 M ) IN AREA IS EXEMPTED FROM THE U-FACTOR ARE FILLED BY SPRAYED/BLOWN INSULATION. 3. STONE OR MASONRY VENEER WITH A 2-INCH (51 MM) CLEAR
AIR SEALING IS PROVIDED BETWEEN THE GARAGE AND CONDITIONED PER 403.6
403.5 MECHANICAL VENTILATION, OUTDOOR AIR
INTAKES AND EXHAUSTS
REQUIREMENT IN SECTION 402.1.4.
402.1.1. GARAGE SEPARATION
AIRSPACE BEHIND THE STONE WITH VENTS AT THE TOP AND
SHALL HAVE AUTOMATIC OR GRAVITY DAMPERS THAT CLOSE WHEN THE
SPACES. BOTTOM. THE VENTS SHALL HAVE AT LEAST 1 SQUARE INCH OF
402.3.4 N/A, NO THERMALLY ISOLATED SUNROOM PROPOSED.
402.3.5 VENTILATION SYSTEM IS NOT OPERATING.
RECESSED LIGHT FIXTURES ARE AIR TIGHT, IC RATED, AND SEALED TO VENT AREA FOR EVERY 24 INCHES (610 MM) OF WALL.
RECESSED LIGHTING
PER 402.3.5 WHERE SOME OR ALL OF AN EXISTING FENESTRATION UNIT IS
DRYWALL. EXCEPTION—FIXTURES IN CONDITIONED SPACE. 4. PANEL SIDING WITH 3/8-INCH (9.52 MM) CLEAR AIRSPACE WITH PER 403.7
403.6 EQUIPMENT SIZING, HEATING AND COOLING EQUIPMENT SHALL BE
INSULATION IS PLACED BETWEEN OUTSIDE AND PIPES. 3
REPLACED WITH A NEW FENESTRATION PRODUCT, INCLUDING /8-INCH (9.52 MM) CONTINUOUS SLOT VENT OPENINGS AT SIZED IN
PLUMBING AND WIRING BATT INSULATION IS CUT TO FIT AROUND WIRING AND PLUMBING, OR BOTH THE TOP AND BOTTOM OF EACH WALL. ACCORDANCE WITH ACCA MANUAL J OR SIMILAR SECTION OF THE
SASH AND GLAZING, THE REPLACEMENT FENESTRATION UNIT RESIDENTIAL CODE OF NEW YORK STATE.
SPRAYED/BLOWN INSULATION EXTENDS BEHIND PIPING AND WIRING. 5. WOOD, WOOD BASED, OR FIBER CEMENT SIDING WITH EITHER A
SHALL MEET THE APPLICABLE REQUIREMENTS FOR U-FACTOR IN
SHOWER/TUB ON EXTERIOR SHOWERS AND TUBS ON EXTERIOR WALLS HAVE INSULATION AND AN 1
/4-INCH (6.35 MM) CLEAR AIRSPACE; OR ALTERNATIVELY A 1/4-
TABLE 402.1.2,
402.1.1, WHERE REQUIRED BY SECTION 101.4.3. WALL AIR BARRIER SEPARATING THEM FROM THE EXTERIOR WALL. 403.7 N/A, NO SYSTEMS SERVE MULTIPLE DWELLING UNITS.
403.8
INCH (6.35 MM) GAP BETWEEN THE HORIZONTAL SIDING LAPS.
402.4 AIR LEAKAGE (MANDATORY). ELECTRICAL/PHONE BOX ON AIR BARRIER EXTENDS BEHIND BOXES OR AIR SEALED-TYPE BOXES ARE 6. VINYL LAP SIDING APPLIED DIRECTLY TO A WEATHER RESISTIVE
EXTERIOR WALLS INSTALLED. SECTION 404 ELECTRICAL POWER AND LIGHTING SYSTEMS
BARRIER.
PER 402.4.1 TTHE AIR BARRIER IS INSTALLED IN COMMON WALL BETWEEN DWELLING
BUILDINGTHERMAL
HE BUILDING THERMAL ENVELOPE
ENVELOPE SHALL
SHALL COMPLYSEALED
BE DURABLY WITH TO COMMON WALL 7. MANUFACTURED STONE VENEER WITH A 3/8-INCH (9.52 MM) PER 404.1 LIGHTING EQUIPMENT (MANDATORY), A MINIMUM OF 50 PERCENT OF THE
LIMIT INFILTRATION . THE SEALING
SECTIONS R402.4.1.1 AND R402.4.1.2.
METHODS THEBETWEEN
SEALING METHODS
DISSIMILAR UNITS. 3 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY
CLEAR AIRSPACE WITH /8-INCH (9.52 MM) CONTINUOUS SLOT
BETWEEN
MATERIALS DISSIMILAR
SHALL ALLOW MATERIALS SHALL ALLOW
FOR DIFFERENTIAL FOR
EXPANSION AND HVAC REGISTER BOOTS THAT PENETRATE BUILDING ENVELOPE ARE LAMPS.
HVAC REGISTER BOOTS VENT OPENINGS AT BOTH THE TOP AND BOTTOM OF EACH WALL.
SEALED TO SUBFLOOR OR DRYWALL.
CONTRACTION . THE EXPANSION
DIFFERENTIAL FOLLOWING AND BE CAULKED, GASKETED,
CONTRACTION.
SHALL 8. OTHER APPROVED CLEAR AIR SPACES AND VENTED OPENINGS. 404.2 N/A ELECTRICAL ENERGY CONSUMPTION IN INDIVIDUAL DWELLING UNITS N/A.
WEATHERSTRIPPED OR OTHERWISE SEALED WITH AN AIR BARRIER
FIREPLACE FIREPLACE WALLS INCLUDE AN AIR BARRIER.
MATERIAL, SUITABLE FILM OR SOLID MATERIAL: PER 402.6 MAXIMUM FENESTRATION U-FACTOR. (MANDATORY). THE AREA SECTION 405 SIMULATED PERFORMANCE ALTERNATIVE
WEIGHTED AVERAGE MAXIMUM FENESTRATION U-FACTOR PERMITTED (Performance) N/A
USING TRADE OFFS FROM SECTION 402.1.4 OR SECTION 405 SHALL BE

THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY


BARRY M. BASHKER, R.A. FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE
FOR BARRY M. BASHKER, R.A. FOR USE SOLELY WITH RESPECT TO THIS
PROJECT AT THIS LOCATION, AND UNLESS OTHERWISE AND SPECIFICALLY
PROVIDED, BARRY M. BASHKER SHALL BE DEEMED THE AUTHOR OF THESE
DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER
RESERVED RIGHTS INCLUD'G COPYRIGHT. THE OWNER SHALL BE PERMITTED
TO RETAIN COPIES OF DRAW'GS, THE SPECIFICATIONS & OTHER DOCUMENTS
FOR THE PROJECT SOLELY FOR THE PURPOSE OF CONSTRUCTION OF THE
PROJECT AT THIS LOCATION. THE DRAWINGS SHALL NOT BE USED BY THE
OWNER OR OTHERS FOR ADDITIONS OR MODIFICATIONS TO THIS PROJECT,
OR FOR COMPLETION OF THIS PROJECT BY OTHERS. C 2019