Spinnerflex Topfit Jumper SF 1/2"-50-Pe SF 1/2"-50-Fr and SF 1/2"-50-Cpr
Spinnerflex Topfit Jumper SF 1/2"-50-Pe SF 1/2"-50-Fr and SF 1/2"-50-Cpr
Electrical Specification
Impedance 50 Ω
IM3 (2 x 20 W) 1) ≤ -160 dBc / typ. -165 dBc
1) Jumper cables with improved IM3 values are available on request.
960 MHz 2,200 MHz 2,700 MHz 3,800 MHz 5,825 MHz
Insertion loss, 11.56 dB/100m 18.64 dB/100m 21.06 dB/100m 25.90 dB/100m 33.79 dB/100m
nominal
(20 °C cable temperature values
without connectors, typ. connector
attenuation is ≤ 0.01 dB)
Template TD-00006B
Mechanical Specification
Minimum bending radius Single / repeated bending radius 25 mm / 32 mm
Crush resistance 20.4 N/mm
Recommended clamp spacing 800 mm
Cable jacket PE black (grey jacket available on request)
Nominal outer jacket diameter 13.7 mm
Connector Material Surface
Inner conductor Cu-alloy Ag-plated
Outer conductor Cu-alloy Ag-plated or CuSnZn-plated
Other metal parts Cu-alloy Ni-plated
Insulation PTFE, PE
Sealing Silicone rubber
Installation instruction M30804
Length definition
> 0.5 - > 1.0 - > 1.5 - > 2.5 - > 4.0 - > 6.0 - > 10.0 - > 15.0 -
Length [m]
1.0 1.5 2.5 4.0 6.0 10.0 15.0 20.0
Tolerances [mm] ± 10 ± 15 ± 25 ± 40 ± 60 ± 100 ± 150 ± 200
Environmental Specification
Degree of protection IP 68 (0.1 bar / 6 hours / unmated)
IP 68 (1 bar / 1 hour / mated)
Recommended temperature
range Storage Installation Operation
SF 1/2”-50-PE -70 °C to +85 °C -40 °C to +60 °C -55 °C to +85 °C
SF 1/2”-50-FR -30 °C to +80 °C -25 °C to +60 °C -30 °C to +80 °C
SF 1/2”-50-CPR -30 °C to +80 °C -15 °C to +60 °C -30 °C to +80 °C
Cable jacket
All jacket types (PE, FR and CPR) Halogen free acc. to IEC 60754-1 and IEC 60754-2
SF 1/2”-50-FR Fire retardant acc. to IEC 60332-1, IEC 60332-3.C, IEC 61034 and UL 1581-1991
SF 1/2”-50-CPR Fire class: B2ca, s1a, d0, a1 acc. to CPR: EN 50575
RoHS compliant to directive 2011/65/EU and amendment (EU) 2015/863
Template TD-00006B
Figure shows low PIM measurement jumpers with 4.3-10 male screw type and 7-16 interfaces.
Template TD-00006B
Dimensions in mm, values above are maximum dimensions and can vary slightly dependent on the cable clamp used.
Dimensions in mm, values above are maximum dimensions and can vary slightly dependent on the cable clamp used.
Template TD-00006B
Dimensions in mm, values above are maximum dimensions and can vary slightly dependent on the cable clamp used.
Template TD-00006B