LIST OF ITEMS CONTROLLED BY CORE (ELECTRICAL) FOR VENDOR DEVELOPMENT

S.N. ITEM DETAILS Specification No. /Drg. No.


(A) Items Under MP Section
1.0 Fabricated &Galvanized Steel Structures for OHE and TSS Relevant RDSO drawing No., IS:2062 (2011), IS:800
2.0 Fabricated & Galvanized Small Parts Steel (SPS) for OHE and TSS Relevant RDSO drawing No., IS:2062 (2011), IS:800
2.1 Fabricated & Galvanised Small Parts Steel (SPS) for OHE only Relevant RDSO drawing No., IS:2062 (2011), IS:800
3.0 Rerolled Angles, Cheenals & Masts
3.1 Column Section (BFB 6”x6” or SC-150) IS:2062 (2011), IS:808 (1989)
3.2 Wide flange beam/joist (RSJ 8”x6” or WB-200) IS:2062 (2011), IS:808 (1989)
3.3 Channel Section (sizes from MC-100 to MC-250) IS:2062 (2011), IS:808 (1989)
3.4 Angle Section (sizes from 50x50x6 to 90x90x8) IS:2062 (2011), IS:808 (1989)
4.0 Copper & Cd Copper Conductors
4.1 5/7 mm. Round Copper Dropper Wire IS:282:1982
RDSO Specification. No.: ETI/ OHE/3(2/94) with A&C Slip No.
4.2 50/105/160 sq.mm. Annealed Copper Stranded Jumper Wires
1
RDSO Specification. No.: ETI/OHE/50 (6/97) with A&C Slip
4.3 20/130 sq.mm. Stranded Cadmium Copper wire
No. 1,2,3,4 &5
4.4 150 sq.mm. Hard Drawn Stranded Copper cross feeder wire RDSO Specification. No.: TI/SPC/OHE/HDCSCF/0030
5.0 19/2.50 mm Galvanized Steel Anti-creep wire RDSO Specification. No.: ETI/OHE/36(12/73) with A&C Slip 1
6.0 Power & control cables (DELETED)
7.0 Gas Chromatograph RDSO specification No. ETI/PSI/105 (7/93)
8.0 Lightning Arrestors (LA)
8.1 42 kV Metal Oxide gapless LA RDSO specification No. TI/SPC/PSI/MOGTLA/0101 (02/2015)
8.2 60 kV Metal Oxide gapless LA
8.3 96 kV Metal Oxide gapless LA RDSO specification No. ETI/PSI/137(8/89) with A&C slip no. 1
8.4 120 kV Metal Oxide gapless LA to 7
8.5 198 kV Metal Oxide gapless LA
9.0 Auxiliary Transformers (AT)
9.1 5 kVA, 25 kV/240 V Single Phase, oil filled AT
9.2 10 kVA, 25 kV/240 V Single Phase, oil filled AT
RDSO specification no. ETI/PSI/15(8/03)
9.3 25 kVA, 25 kV/240 V Single Phase, oil filled AT
9.4 50 kVA, 25 kV/240 V Single Phase, oil filled AT
RDSO specification no. ETI/PSI/15A(7/82) pt-1 with A&C Slip
9.5 100 kVA, 25 kV/240 V Single Phase, oil filled AT
No. 1
10.0 Current Transformers (CT)
10.1 25 kV CT ratio 1500-750/5 A
10.2 25 kV CT ratio 1000-500/5 A
10.3 25 kV CT ratio 200-100/5 A
10.4 25 kV NCT ratio 2/1 and 5/1 A RDSO specification no. ETI/PSI/90(6/95)A&C slip 1to 8
10.5 25 kV CT 2-Core PS class ratio 3000-1500/5 A
10.6 25 kV CT 2-Core PS class ratio 1500-750/5 A
10.7 25 kV CT single Core PS class ratio 1500-750/5A
10.8 66 kV CT ratio 800-400/5 A
10.9 110 kV CT ratio 400-200/5 A
10.10 132 kV CT ratio 400-200/5 A RDSO specification no. ETI/PSI/117(7/88) A&C slip 1 to 9
10.11 132 kV CT ratio 1200-800-400/5-5-5 A Class 5P/0.2/PS
10.12 220 kV CT ratio 200-100/5 A
11.0 Potential Transformer (PT)
11.1 25 kV PT Type-I
11.2 25 kV PT Type-II
11.3 66 kV / 110/√3 V PT
RDSO specification no. TI/SPC/PSI/PTs/0990 with A&C Slip
11.4 110/√3 kV⁄ 110 V PT
No. 1 to 5
11.5 100-110/√3 kV / 110/√3- 110/√3 V PT (used in Mumbai Suburban area)
11.6 132/√3 kV⁄ 110 V PT
11.7 220 kV / 110/√3 V PT

(B) Items Under OHE Section


1.0 25kV AC SP/DP Isolators with/Without Earth Switch
1.1 25 kV AC, 1250 A SP Isolators with/without earth switch
1.2 25 kV AC, 1250 A DP Isolators with/without earth switch
ETI/OHE/16 (1/94) Rev2 (Mar-04) and RDSO’s letter No.
1.3 25 kV AC, 1600 A SP Isolators with/without earth switch
TI/PSI/ 25/ ISOL /POLICY /99 dt 3.6.99
1.4 25 kV AC, 1600 A DP Isolators with/without earth switch
LIST OF ITEMS CONTROLLED BY CORE (ELECTRICAL) FOR VENDOR DEVELOPMENT

S.N. ITEM DETAILS Specification No. /Drg. No.


1.5 25 kV AC 3150 A SP Isolators with/without earth switch
1.6 25 kV AC 3150 A DP Isolators with/without earth switch
2.0 66/132/220kV DP/TP Isolators with/without earth switch
2.1 66 kV AC, 1250 Amp D.P/TP Isolators
2.2 132/145 kV AC, 1250 Amp DP Isolators
ETI/PSI/122(3/89) Rev.1. (April-90)
2.3 132/145 kV AC, 1250 Amp TP Isolators
2.4 245 kV AC, 1250 Amp DP Isolators
2.5 245 kV AC, 1250 Amp TP Isolators
3.0 Automatic Changeover Control Panel for Colour Light Signalling
3.1 Automatic changeover Control panel for Colour Light Signaling 30 Amps

3.2 Automatic changeover Control panel for Colour Light Signaling 60Amps
TI/SPC/PSI/CLS/0020(12/02) (with A&Cslip No1 to 4 )
3.3 Automatic changeover Control panel for Colour Light Signaling 150 Amps

3.4 Automatic changeover Control panel for Colour Light Signaling 300 Amps
4.0 25kV DO fuses
4.1 25 kV DO fuse Switch Assembly
4.2 25 kV DO fuse link , 1Amp
ETI/PSI/14(1/86) Rev 1 (Apr-87)
4.3 25 kV DO fuse link, 5Amp
4.4 Operating Pole for 25 kV DO fuse
5.1 Discharge rod/Earthing pole Assembly of 25 AC Traction ETI/OHE/51(9/87) Rev. 1. (Oct-92)
Retro-reflective Structure Number Plates/Caution Boards on Al- alloy
6.1 ETI/OHE/33A (12/97), Rev-8 (11/2012)
board.
6.2 Vitreous Enameled steel structural number plates/ Boards ETI/OHE/33 (8/85)
7.0 Stainliss Steel Fasteners
High-tensile bolts & nuts, studs, bolts, screws-bolts, pins of various
7.1
sizes, used for OHE fittings
TI/SPC/OHE/Fasteners/0120 (Mar 2013)
7.2 Spring washers
7.3 Flat round washer of various sizes
8.0 GI Fasteners
Bolts, and nuts including U bolt development J-bolt, snap headed
8.1
pins/rivet of all sizes used for OHE fittings TI/SPC/OHE/Fasteners/0120 (Mar 2013)
8.2 Flat/round washers/Spring Washers
IS:740-1977, IS:2907-1988, IS: 549-2005 (See Annexure - I for
9.0 Non-Ferrous Fasteners (Split Pin, Rivets, Washers etc)
Details)
10.1 230 Volt AC & 110 Volt DC/Distribution Panel ETI/PSI/29 (12/79) Rev-1 (Feb'93)
11.0 Variuos Types of OHE fittings
TI/SPC/OHE/Fittings/0130 (10/13) (See Annexure A of Vendor
11.1 Aluminium Bronze / Tin Bronze fittings
directory for Details)
TI/SPC/OHE/Fittings/0130(10/13) (See Annexure B of Vendor
11.2 Copper fittings
directory for Details)
TI/SPC/OHE/Fittings/0130(10/13)& ETI/OHE/13 (4/84) with
11.3 (a) MCI fittings (Retained as MCI Fittings)
A&C – 1 to 3 (See Annexure C of Vendor directory for Details)

TI/SPC/OHE/Fittings/0130(10/13)& ETI/OHE/13 (4/84) with


11.3 (b) MCI fittings (Converted in to forged fittings)
A&C – 1 to 3 (See Annexure C of Vendor directory for Details)
TI/SPC/OHE/Fittings/0130(10/13)& ETI/OHE/21 (9/74) (See
11.4 Aluminium - Alloy Fittings, Extruded Tubes & Sections
Annexure D of Vendor directory for Details)
IS : 2004 – 1991, ETI/OHE/13 (4/84) with A&C – 1 to 3 (See
11.5 Forged Steel fittings
Annexure E for Details)\
TI/SPC/OHE/Fittings/0130(10/13)& ETI/OHE/13 (4/84) with
11.6 Steel Galvanised Fittings
A&C – 1 to 3 (See Annexure F of Vendor directory for Details)
11.7 Copper Strip 25mm ×3mm and Copper Bar 18mm dia IS 191/1981 & IS:613/ 1984
TI/SPC/OHE/Fittings/0130(10/13)& ETI/OHE/13 (4/84) with
11.8 SGCI Fittings
A&C – 1 to 3 (See Annexure J of Vendor directory for Details)
IS : 210 – 2005 (Grade FG-150) (See Annexure G of Vendor
12 Cast Iron Counter Weights
directory for Details)
ETI/OHE/11(5/89), IS:1239 (25 mm) NB Light Class, ETI/OHE/13
13 Galvanised ERW steel tubes & Counter Weight Guide Tube (4/84) with A&C Slip No. 1, 2 & 3, Drawing No. ETI/OHE/5060-2
Rev-C (See Annexure - H of Vendor directory for Details)