7 NO'S OF 12 MM Ø BEAM SCHEDULE

ANCHO R BAR
8 MM Ø STIRRUPS @ 300 MM C/C 7 NO'S OF 12 MM Ø BAR PROVIDED BEAM
BEAM NO BEAM SIZE (B X D) NO. OF BARS MAIN BAR DIA. STIRRUPS
REINFORCEMENT
7 NO'S OF 12 MM Ø
ANCHOR BAR
8 MM Ø 450
STIRRUPS
8 MM Ø 8 MM Ø @ 300 MM
B1 300 X 450 MM STIRRUPS 7 12 MM Ø
C/C
7 NO'S OF 12 MM Ø
MAIN BAR 4.23 7 NO'S OF 12 MM Ø
MAIN BAR

C/S OF BEAM 400 DETAILS OF BEAM (B 1) 400

FOOTING SCHEDULE
EFFECTIVE DEPTH OVERALL DEPTH - FOOTING REINFORCEMENT
FOOTING TYPE LENGTH - L (MM) WIDTH - B (MM) NO OF BARS
- d (MM) D (MM)
AST 1 AST 2
100 2100 100 16 MM Ø @ 170 MM 16 MM Ø @ 170
F8 2100 2100 450 500 6 C/C MM C/C

100
400

400
COLUMN SCHEDULE

2100
COLUMN SIZE COLUMN
COLUMN NO (B X D) NO. OF BARS MAIN BAR DIA. LATERAL TIES
REINFORCEMENT
400

100
6 MM Ø @ 250 MM
C8 400 X 400 MM 8 16 MM Ø

400
C/C

PLAN OF COLUMN AND FOOTING

GENERAL NOTES:-
• FOUNDATION UP TO HARD STRATA, MIN DEPTH OF EXCAVATION IN STRATA = 300 MM
• CONCRETE MIX TO 1:1.5:3 (M-20) {UNLESS SPECIFIED}.
• Ø DENOTES TOR STEEL BARS. {IS-1786}
6 MM Ø LATERAL TIES
@ 250 MM C/C
• # DENOTES MILD STEEL BARS GRADE 1 {IS-432}.
• LAPS FOR BEAM = 60 X D AND FOR COLUMNS = 50 X D, D = DIAMETER OF BAR.
PLINTH / TI E BEAM 8 NO'S OF 16 MM Ø
LONGI TUDINAL STEEL
• MINIMUM CONCRETE COVERING = 50 MM, COLUMNS = 40 MM AND BEAMS = 25 MM.
• THIS DRAWING IS TO BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTS DRAWINGS.
FLOORING • DO NO SCALE THE DRAWING.
• CONCRETE MIX QUALITY, SHUTTERING, CURING IS CONTRACTOR'S RESPONSIBILITY.
0.10 M THK P.C.C
• WHILE WORKING ON THE SITE ABUTTING TO ADJUSTMENT BUILDING SHALL BE DONE PROPERLY BY CONTRACTOR
0.3 M RUBBLE SOLING AND FOR ANY DAMAGE DUE TO SAME WE SHALL NOT BE HELD RESPONSIBLE.
• DESHUTTERING PERIOD SHALL NOT BE LESS THAN SPECIFIED BELOW -
0.15 M MURUM FILLING 1. BEAMS
A. SPANNING UP TO 6 M = 14 DAYS.
40 MM COVER TO COLUMN B. SPANNING OVER 6 M = 21 DAYS.
2. VERTICAL FACES OF COLUMNS, BEAMS AND R.C.C WALLS = 16 - 24 HOURS.

400 MM 400 MM 16 MM Ø @ 170 MM C/C IN


BOTH X AND Y DIRECTION
50 MM CLEAR COVER
TO FOOTING JALI 0.26 M ( DEPTH OF FOOTING)
DESIGN OF BEAM, COLUMN AND FOOTING
0.15 M THK P.C.C (1:3:5)

100 2100 100 NAME :-


SHEET NO :- 02 ROLL NO :-
SECTION THROUGH FOOTING
DATE OF PERFORMANCE :- DATE OF SUBMISSION :-

DETAILS OF COLUMN (C16) AND FOOTING MARKS :- SIGN :-


COLLEGE :- K. K. WAGH POLYTECHNIC, NASHIK.