VEGA ENG MANUAL BASIC AND SETTING LCD59X Rev.3-2
VEGA ENG MANUAL BASIC AND SETTING LCD59X Rev.3-2
PARALLEL
Rev. n.3 Firmware: V1.2
DISPLAY CODES
(*): available with yellow digits and arrows for LCD599-A-G model
KIT
CODE DESCRIPTION
- N.2 magnetic sensors NO
KIT-AUTONOMO-NO - N.2 sensor supports
- Guide/ bracket L.25 cm
MAGNETE-150 - 15 cm Magnet
CODE DESCRIPTION
VG003 Chrome frame kit
VG004 Gold frame kit
VG007 Gunmetal frame kit
VG008 Satin nickel frame kit
KIT FL174 X79-1.2 Flush mounting kit (Thk. 1,2 mm)
KIT FL174 X79-2 Flush mounting kit (Thk. 2 mm)
LCD 59X
ENT SEL
1
LCD 59X
VCOM
OVL
13
14
OS
V
OVERLOAD
OU T O F SERVICE / GO NG
INPUT 13
INPUT 14
Floor N°
+V GND
Power supply
12/24 VDC
Higher
Lower Impulsor A
Impulsor B
MAGNETIC
IMPULSORS
Floor 1
D:
Min=
40mm FIRST FLOOR (1)
2D
MAGNETS
NOTE: AO= Normally open
AC= Normally closed
§ 4. (M2) WORKING MODE
2D
Min=
80mm Rephasing floor (0)
It s possible to change the
Floor 0
rephasing floor on the menu:
§ 4. (M4) FIRST FLOOR REPHASING
FLOOR (0)
2D
2D
FIRST
3.2.1 SPECIFICATIONS: UNDERGROUND
-Minimum distance between floor: 40cm FLOOR (-1)
2D
Min= - Minimum distance between sensors: D
Floor -1 (min=40mm);
80mm
- Minimum magnet length: 2D
(min=80mm);
-Minimum speed: Vmin =0.4 m/s;
-Maximum speed: VMAX =2 m/s;
- Re-phasing: After 5 seconds at the re
phasing floor.
2
LCD 59X
[4] MENU’
ENTER/SW2 SELECT/SW1
Click!! Click!!
Save/OK button Access the menu/Scroll values
x 5 sec.
ENT
Reset DEFAULT Normal
Programming
SEL
SYMBOLS
Select the Choose the ENT Choose the
-1..9
Choose the coding mode of the floors B- : Binary with (-) symbol
DE: Demo;
AO: Magnetic sensors normally open;
SEL AC: Magnetic sensors normally closed.
ENT ENT
display backlight shutdown
99= 99 minutes.
ME
SEL
FIRST FLOOR
Choose the first floor value. ENT First floor selection: ENT
M4
ME
-1
Buzzer volume:
VOLUME ENT 0 = disabled; ENT
15
M8
Enable/Disable the courtesy light 0: Backlight ON, normal mode;
1: Turn ON all display s segments and
ME
icons.
SEL
Floor adress setting:
NEXT DIRECTION ARROWS 0: First floor;
ENT 1: Second floor; ENT
32
20 = 1s.
SEL
FS;
OUT OF SERVICE SYMBOL HS;
ENT ENT
FS
OS;
MB Choose the Out of Service symbol
AB; ME
--;
XX.
SEL
By choosing a N floor, it will be added a new
floor with the symbol -- before it.
ADD A FLOOR
To change the symbol of the added floor use ENT
ENT
ME
-9
MC the M1 menu.
Example: 0, R, 1, 2, 3
Ex: MC=1 0, --, 1, 2, 3,
M1 -- = R
SEL 0, R, 1, 2, 3, ...
MD Example: 0, 2, 3
Nmax floors
Display Mode Description
[default range]
1P 1 Pole per floor Each input is associated with one floor. [§ 5.1] 14 [-1, 12]
B Binary The first five inputs [1,..., 5] are used for coding the floor number in binary. [§ 5.2] 32 [-1, 30]
Bn Inverse binary The first five inputs [1,…, 5] are used for coding the floor number in inverse binary [§ 32 [-1, 30]
5.2]
BC BCD The first four inputs [1,...,4] are used for coding the floor number in inverse binary, 29 [-9, 19]
while 5 is used for the tens and I6 for the minus sign (-). [§ 5.4]
GR Gray 5 The first five inputs [1,…, 5] are used for coding the floor number in Gray. [§ 5.3] 32 [-1, 30]
B- Binary with (-) The first five inputs [1,..., 5] are used for coding the floor number in binary. The I6 32 [-1, 30]
symbol input is used to show (-) symbol.
7S 7Segments Each input is associated with one digit segment, while I12 is used for the tens and 11 109 [-9, 99]
for the minus sign (-). [§ 5.5]
NO Stand-Alone AO Magnetic sensors Normally Open. 64 [-9, 54]
NC Stand-Alone AC Magnetic sensors Normally Closed. 64 [-9, 54]
DE Demo Simulation mode: you can view floors, arrows and alarm icons.
NOTE: With M2=B- the I6 input if active enables the (-) symbol for the floors from -1 to -9 (the other follow Binary codification.)
Binary Inverse Binary 1 (A) 2 (B) 3 (C) 4 (D) 5 (E) Floor number 1 (A) 2 (B) 3 (C) 4 (D) 5 (E)
0 31 OFF OFF OFF OFF OFF 0 OFF OFF OFF OFF OFF
1 30 ON OFF OFF OFF OFF 1 ON OFF OFF OFF OFF
2 29 OFF ON OFF OFF OFF 2 ON ON OFF OFF OFF
3 28 ON ON OFF OFF OFF 3 OFF ON OFF OFF OFF
4 27 OFF OFF ON OFF OFF 4 OFF ON ON OFF OFF
5 26 ON OFF ON OFF OFF 5 ON ON ON OFF OFF
6 25 OFF ON ON OFF OFF 6 ON OFF ON OFF OFF
7 24 ON ON ON OFF OFF 7 OFF OFF ON OFF OFF
8 23 OFF OFF OFF ON OFF 8 OFF OFF ON ON OFF
9 22 ON OFF OFF ON OFF 9 ON OFF ON ON OFF
10 21 OFF ON OFF ON OFF 10 ON ON ON ON OFF
11 20 ON ON OFF ON OFF 11 OFF ON ON ON OFF
12 19 OFF OFF ON ON OFF 12 OFF ON OFF ON OFF
13 18 ON OFF ON ON OFF 13 ON ON OFF ON OFF
14 17 OFF ON ON ON OFF 14 ON OFF OFF ON OFF
15 OFF OFF OFF ON OFF
15 16 ON ON ON ON OFF
16 OFF OFF OFF ON ON
16 15 OFF OFF OFF OFF ON
17 ON OFF OFF ON ON
17 14 ON OFF OFF OFF ON
18 ON ON OFF ON ON
18 13 OFF ON OFF OFF ON 19 OFF ON OFF ON ON
19 12 ON ON OFF OFF ON 20 OFF ON ON ON ON
20 11 OFF OFF ON OFF ON 21 ON ON ON ON ON
21 10 ON OFF ON OFF ON 22 ON OFF ON ON ON
22 9 OFF ON ON OFF ON 23 OFF OFF ON ON ON
23 8 ON ON ON OFF ON 24 OFF OFF ON OFF ON
24 7 OFF OFF OFF ON ON 25 ON OFF ON OFF ON
25 6 ON OFF OFF ON ON 26 ON ON ON OFF ON
26 5 OFF ON OFF ON ON 27 OFF ON ON OFF ON
27 4 ON ON OFF ON ON 28 OFF ON OFF OFF ON
28 3 OFF OFF ON ON ON 29 ON ON OFF OFF ON
29 2 ON OFF ON ON ON 30 ON OFF OFF OFF ON
30 1 OFF ON ON ON ON 31 OFF OFF OFF OFF ON
31 0 ON ON ON ON ON
4
LCD 59X
[5.4] BCD
Floor 5 (E) = Floor 5 (E) =
1 (A) 2 (B) 3 (C) 4(D) 1 (A) 2 (B) 3 (C) 4(D)
number DECINE number DECINE
0 ON ON ON ON OFF 10 ON ON ON ON ON
1 OFF ON ON ON OFF 11 OFF ON ON ON ON
2 ON OFF ON ON OFF 12 ON OFF ON ON ON
3 OFF OFF ON ON OFF 13 OFF OFF ON ON ON
4 ON ON OFF ON OFF 14 ON ON OFF ON ON
5 OFF ON OFF ON OFF 15 OFF ON OFF ON ON
6 ON OFF OFF ON OFF 16 ON OFF OFF ON ON
7 OFF OFF OFF ON OFF 17 OFF OFF OFF ON ON
8 ON ON ON OFF OFF 18 ON ON ON OFF ON
9 OFF ON ON OFF OFF 19 OFF ON ON OFF ON
NOTE: The input 6 is used for the sign "-". If 5 and 6 are both [ON], 6 has priority.
NOTE: The tables above refer to codes with the
[5.5] 7 SEGMENTS first floor set to "0" (MENU M4 = 0).
INPUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14
SEGMENT a1 b1 c1 d1 e1 Gong g1 a b c d e f g
DIGIT Tens/Sign "-" Unit
NOTE: To view the “f1” segment on the display using input 6, set M6=1. Gong is activated by signal on OS input.
a1 a
f1 b1 f b
g1 g
e1 c1 e c
d1 d
PROTECTION GLASS
PANEL
BLOKING TOOL
DISPLAY
5
LCD 59X
[7] DIMENSIONS
150
134,6
122
16,1
46,5
46,5
40,9
56
56
40,9
46,5
56
40,9
20
[9] CUTOUTS
144 120,2
6
LCD 59X
[10] TROUBLESHOOTING
SOLUTION
PROBLEM POSITIVE COMMON NEGATIVE COMMON
The display doesn’t turn on. Check the power supply between: Check the power supply between:
V = Negative, Vcom = positive 12÷24 Vdc V = positive, Vcom = negative 12÷24 Vdc
The display flashes or doesn’t
properly turn on. Make sure that the display is correctly powered. [§ 3.1]
A floor / an arrow / an alarm is Check the voltage between the input and VCOM.
not showed. Restore the default values by pressing and holding down the “SW2” button for 5 seconds.
In the Binary, Bn, BC and Gray
modes, when you switch from a Increase the inputs reading time:
floor to another, the display MENU MA = 04 200ms.
shows another floor number for
a short time.
The display does not light up, Increase the backlight shutdown (stand-by) time.
but it correctly shows floors and Backlight damaged, contact the technical support service.
arrows.
DIAGNOSTIC LED:
WORKING LED
FUNCTION
MODE (M2) ON
ST1 Any input is enabled.
1P
ST2 ERROR: two or more floor input are enabled at the same time.
ST1 One or more alarm/arrow inputs are enabled.
B / BN / BC /
One or more floor inputs are enabled.
GR / 7S ST2
Superior sensor enabled (closed if normally open or open if normally closed):
ST1
the input 13 is enabled.
AO / AC
Inferior sensor enabled (closed if normally open or open if normally closed).
ST2
the input 14 is enabled.