Company Profile

www.tcreng.com 2009
Chemical Analysis - Instrumentation

Model/ Type/ Range/ Date of Calibration Traceability


Name of Equipment Make & IN Accuracy calibration Due on
SERVICE
Automatic Carbon Sulphur Determinator LECO/CS244 ±0.005 C
Daily - -
USA 1990 ±0.005 S
Automatic Carbon Sulphur Determinator LECO/CS400 ±0.005 C
Daily - -
USA 1997 ±0.005 S
Atomic Absorption Spectrometer (OES) ParkinElmer ±1% of
Daily - -
Analyst 2006 Concentration
Optical emission Spectrometer ARL QUANTRIS/ ±1% of
Daily - -
Switzer.JUNE 2006 Concentration
ICP Spectrometer Leeman Labs Inc PRODIGY SPEC ±1% of
Daily - -
Sr No 5003JUNE 2005 Concentration
Glow Discharge Spectrometer (GDS) LECO ±1% of
Daily - -
GDS 500A Concentration
Electronic Weighing
Machine – Metler/ Swiss/Japan/Italy ±0.1mg 13/11/2008 22/11/2009 -NPL
Shimatzu / Gibratini

Inspection - Positive Material Identification (PMI), RoHS, Feritscope, Portable Hardness

Model/ Type/ Range/ Date of Calibration Traceability


Name of Equipment Make & IN Accuracy calibration Due on
SERVICE
X –MET 3000 TX -
Finland ±5% Daily -
X –MET 3000 T -
Finland ±5% Daily -
Metal Master 2000 Finland ±5% Daily - -
Niton XLT 898 USA ±5% Daily - 3 Nos
Innov-X Alpha 4000
Netherlands ±5% Daily - -
(ROHS Test)
Feritscope (MP30E-S)
Fischer / USA - -
Sr. No. – 106-23060A
Portable Hardness Tester TH-130/ HL- 200 -
5% Daily -
China

Wet Chemical Analysis

Model/ Type/ Make & IN Range/ Accuracy Traceability


Name of Equipment SERVICE
Muffle Furnace TCR/WAO/EQP/09 0-1000°C/ NPL
Muffle Furnace TCR/WAO/EQP-010 0-1000°C NPL
Oven Lab Hosar/ 0-300°C/
NPL
TCR/WAO/EQP-016
Oven EXPO/TCR/WAO/EQP-014 0-100°C NPL
Oven TEMPO/Sr.no.4121O4 0-300°C NPL
Glass Thermometer KWALITY/ -100-+50°C/
NPL
TCR/MEC/EQP/22 ± 2°C
Glass Thermometer JRM/ -50 - +50°C
NPL
TCR/MEC/EQP/31 ± 1°C
Glass Thermometer JRM/ -10 - 360°C/
NPL
TCR/MEC/EQP/3129 ± 1°C
Analog DC Ammeter 0-10 A
LCC/TCR/WAO/EQP/018 -
± 1% FSD
Analog DC Voltmeter LEE/ 0-15 V
-
TCR/WAO/EQP/DCV 018 ± 1% FSD
Electronic Digital Balance Mettler,
0-51 gm
Model- AB 54-s NPL
±0.1 mg
TCR/wao/eqp/011

Revised Date: 10/13/2009 Creation Date: 12/13/07


BY: TCR Engineering Services PAGE 30