1 General functional description Page 2/17

File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany

Table of contents
1. General functional description........................................................................ 3
1.1 General program description ............................................................... 3
1.2 New program functions........................................................................ 3
1.2.1 Display of the preset value in case of overflow.................................... 3
1.2.2 Control for dispenser ........................................................................... 3
1.2.3 Volume totalizer................................................................................... 4
1.2.4 Comma setting with parameter 23 ....................................................... 4
1.2.5 Indication of wrong programmed basic parameters............................. 5
2. Installation and starting ................................................................................... 6
2.1 Requirements for starting .................................................................... 6
2.1.1 Fundamental proceeding ..................................................................... 6
3. Programming .................................................................................................... 7
3.1 P00 Country version ............................................................................ 7
3.1.1 Summary of the country versions ........................................................ 7
3.2 P01 Different mode of operation.......................................................... 8
3.3 P02 Type of pump ............................................................................... 9
3.4 P03 Pump number for remote control ............................................... 11
3.5 P04 Base Price Adjustment ............................................................... 12
3.6 P05 Error statistic not deletable......................................................... 13
3.7 P22 Adjust the volume totalizer ......................................................... 14
3.8 P23 Focusing the decimal places ...................................................... 14
3.9 Overview register 26 .......................................................................... 15
3.10 P28 Deleting of error statistic................................................................ 17
1 General functional description Page 3/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany

1 General functional description


1.1 General program description
The program X2003-6/8 is used for the calculator hardware X2003 and for single
DUO-6/3 and DUO-8/4 functions. It is possible to use either the DART- or the
current-loop- interface. For the DART-interface it is possible to have the fuel and
the standard mode. The standard mode is configured for connections to other
systems. The different interfaces are prepared for all countries.
1.2 New program functions
1.2.1 Display of the preset value in case of overflow.
While filling with preset or with payment terminals it is possible, that the pump
does not stop at the exact preset value. If you set the parameter 26-41 to 1 the
overflow value will be shown at the display and transmitted to the Marketer
System. That function only works, if the overflow is not to high. If there is a
damaged magnetic valve it would not work.
1.2.2 Control for dispenser
In some countries there is a check-up after switching the main pump, if the pipes
are leak-proofed. For that function the main pump should run about 5 seconds
and the main valve should be switched on. That function will be activated with the
parameter 26-43 (put in 1).
To get a lead time about 5 seconds the parameter 26-7 has to be changed from
450 (750 ms) to 1000 (1.667 sec.). The display test runs 5 seconds and the main
pump runs 5 seconds before the opening of the magnetic valve.
1 General functional description Page 4/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany
1.2.3 Volume totalizer
The totalizer stores for every pulser a 10 digit wide memory. The first 8 digits are
shown at the display by using a magnetic stick or the programming box. The
calculator, which is configured for DUO mode, has a ‘side 1’ and a ‘side 2’. Letters
from A to E show the order of the pulser. The read-out of the values is possible
with one call for both sides. Every five seconds another value will automatically be
shown at the display. After showing the last value the read-out will stop and the
display will show the last value.
That function is automatically activated after a ‘cold-start’. With parameter
26-39 = 0 it is possible to switch off that function. When that function is activated,
the totalizer has to be set in the parameter 22. It is necessary to set the parameter
22! The value for 22 could be zero or a another value in case of exchange of the
calculator. The co-ordination of the pulser is from 1 to 8.
After the data announcement to the totalizer the display shows the following :
X= Produc A-E
Y= Side 1-2
1.2.4 Comma setting with parameter 23
Independent of the country codes that function allows the setting of the decimal
places. So it is possible to react fast to currency changes. While changing the
decimals the arithmetic is also changed automatically. It is necessary to set a new
unit price for the calculator in the standalone mode. The decimal places have to
be fed into the computer at the right place with ENTER.
XY 1 2
345678
1 General functional description Page 5/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany
1.2.5 Indication of wrong programmed basic parameters
After a cold-start it often happens locally, that the main parameters will not be put
at the right place. Therefore the computer does not permit any fuelling. The
computer version D recognises a wrong parameter and indicates this with blining.
Xx corresponds at 02: parameter for pump type not adjusted
03: pump number is lacking for data communication
04: basic purchase price not adjusted in the self-sufficiency use
22: totalizer start value not adjusted
Only a recognised wrong parameter can be indicated. If there are more than one
parameters adjusted in a wrong way, only the first - recognised as a wrong one
will be shown. After the abatement of the first nuisance the next wrong number of
parameter will be advised.
P-xx
2 Installation and starting Page 6/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany

2 Installation and starting


2.1 Requirements for starting
2.1.1 Fundamental proceeding
1 Correct connection of all pump components and peripheral devices.
Attention: during this phase SWITCH OFF POWER !
2 Turn the switch at the loop-print in position OFF !
3 Connect the programming box.
4 SWITCH POWER ON and COLD-START with simultaneous pressing
the keys 1 and 7.
5 Programming of the pump computer :
3.1 Has to be programmed by connection with the Marketer
(Serial connection ):
Register : P00, P01, P02 , P03 and P22.
3.2 Has to be programmed in standalone mode:
Register : P00, P01, P02, P04 and P22.
3.3 Has to be programmed by connection of an impulse interface:
Register : P24.
6 Disconnect programming box.
7 Turn the switch on the loop-print in position ON.
8 Carry out the check of all pump functions.
If you are not sure that the computer has done the cold-start, please program in
the register 00 the value 4 and control after the cold-start, if the value has
changed from 4 to 1.
3 Programming Page 7/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany

3 Programming
3.1 P00 Country-Version
This register is loaded with the base adjustment country 1. With alteration of this
parameter the relevant parameters will be adjusted. By leaving this function the
main program will initialize the correct parameters of the selected country.
Programming :
Input : 0 and afterwards ENTER
Display : P00 X X = 1 to 9
Input : press ENTER until the correct country is shown.
Input : press CLEAR key in order to store the last shown country
and leave the register.
Display : P—
3.1.1 Summary of the Country Versions
Reg.: Land: Decimal places
a, v, bp
1 Germany 2, 2, 1
2 Switzerland 2, 2, 1
3 Netherlands 2, 2, 3
4 Belgium 1, 2, 2
5 Austria, Czech Republic, Slovakia, 1, 2, 2
Russia, Ukraine (x1000)
6 Hungary 1, 1 decimal place in the amount 1, 2, 1
7 Hungary 2 (Shell), no decimal place in the amount 0, 2, 1
8 Poland, Croatia 2, 2,2
9 Bulgaria 1, 2, 1
10 Romania, Italy 0, 2, 0
11 Portugal 1, 3 decimal places vol. 0, 3, 1
12 Portugal 2; Spain, no decimal place in the amount 0, 2, 1
a = amount, v = volume, bp = basic price
3 Programming Page 8/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany

3.2 P01 Different mode of operation


There are two different modes of operation:
1: Connection to the Marketer System.
2: Standalone mode (autark).
Programming:
Display: P—
Input: 1 and ENTER
Display: P01 1 current adjustment (flashing)
Input: press ENTER until the correct adjustment will be displayed.
Input: press CLEAR in order to store the selected adjustment.
Display: P--
3 Programming Page 9/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany

3.3 P02 Type of pump


With this function the type of pump will be programmed. The following description
shows the different possibilities.
Type : Product : Capacity :
1 SINGLE 1 Product 1 0 = Standard pump (Slow rate BP x 0,6)
1 = Highspeed pump (Slow rate BP x 0,9)
5 = Highspeed pump (50 l, Slow rate
BP x 0,9)
2 DUO 1 Product 1 0 = Standard pump (Slow rate BP x 0,6)
1 = Highspeed pump (Slow rate BP x 0,9)
5 = Highspeed pump (50 l Slow rate
BP x 0,9)
3 DUO 3 Multiproduct pump (up to 2 x 3 products)
0 = Standard pump (Slow rate BP x 0,6)
1 = Highspeed pump (Slow rate BP x 0,9)
4 DUO 4 Multiproduct pump (up to 2 x 4 products)
0 = Standard pump (Slow rate BP x 0,6)
1 = Highspeed pump (Slow rate BP x 0,9)
5 SINGLE 5 Multiproduct pump (up to 5 products)
0 = Standard pump (Slow rate BP x 0,6)
1 = Highspeed pump (Slow rate BP x 0,9)
3 Programming Page 10/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany
Programming:
Display : P—
Input : 2 and afterwards ENTER
Display : Example for a DUO-computer, X2003-6 (multiproduct)
Display-Position A Display-Position B
Computer Type P 0 2 3 Blank
Nozzle 1 to 3 1 2 3 Blank
Capacity 60l/min CAP 0 Blank
Display : Example for a DUO-computer, X2003-8 (multiproduct)
Display-Position A Display-Position B
Computer Type P 0 2 4 Blank
Nozzle 1 to 4 1 2 3 4 Blank
Capacity 60l/min CAP 0 Blank
Display : Example for a SINGLE-computer (one product)
Display-Position A
Computer Type P 0 2 1
Nozzle 1 Code 1
Capacity 60l/min CAP 0
During the input of the products (nozzle 1 - 5) it is possible to decide, which nozzle
should deliver which product.
If a pump is operated with the Marketer System the products should be assigned
at the Marketer System.
General comments :
The relevant parameter, which has to be changed, is flashing.
If the parameter should be changed put the key in the new value and
confirm with ENTER.
If the function should be exit, please confirm with CLEAR.
If the parameter should not be changed but switched to the next parameter,
please only press ENTER.
3 Programming Page 11/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany

3.4 P03 Pump number for REMOTE CONTROL


Each computer must be named with the corresponding pump number.
Only the values 01 to 16 (for DART 24) will be accepted!
If the input for the pump number is higher than 16 (24) the value will be ignored
and the computer keeps the old value for the pump number.
Programming:
Display : P—
Input : 3 and ENTER
Display : P03
1 old pump number (flashing)
Input : 1 and 6 new pump number (e.g. 16)
Input : ENTER - store value
Display : P03
16 new pump number (flashing)
Input : CLEAR - exit function
Display : P—
Remark:
For a DUO-function the position A will be programmed at first and secondly the
position B.
The value for the position A is shown on the display on the side A.
The value for the position B is shown on the display on the side B.
3 Programming Page 12/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany
3.5 P04 Base Price Adjustment
If the pump is operated in the standalone mode the base price must be adjusted
locally at the pump.
SINGLE computer. max. 5 base prices per fuelling position (P04 / 01-05)
DUO computer: max. 4 base prices per fuelling position (P04 / 01-04 Side A)
(P04 / 06-09 Side B)
Programming:
1 Display: P--
2 Input: 4 and then ENTER
3 Display: P04 01 Product display (flashing)
1,029 current base price (flashing)
1,029 current base price (constant)
The base price should be changed: go to item 4
The old price should be kept: go to item 5
4 Input: Key in the new base price (e.g. 98,9 price/litre)
Input: 0 and then ENTER
Input: 989 and then ENTER (price)
Display: P04 01 Product (flashing)
0,989 current base price (flashing)
102,9 old base price (constant)
5 Input: ENTER
Store the base price and switch to the next item:
no further changing of the base price: go to item 6
change the next base price: go to item 3
6 Input: CLEAR (in order to exit the register).
7 Display: P--
3 Programming Page 13/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany

3.6 P05 Error statistic not deletable


In this register block 26 registers could be chosen, which record a meaningful
error statistic for service purposes.
Register: Description:
1 number of CPU-Resets
2 number of electricity-breakdowns
3 number of distance transmission errors
4 number of RAM errors
5 number of EPROM errors
6 number of impulse sequence errors IG 1
7 number of impulse sequence errors IG 2
8 number of impulse sequence errors IG 3
9 number of impulse sequence errors IG 4
10 number of impulse sequence errors IG 5
11 number of impulse sequence errors IG 6
12 number of impulse sequence errors IG 7
13 number of impulse sequence errors IG 8
14 number of IG.-current errors IG 1
15 number of IG.-current errors IG 2
16 number of IG.-current errors IG 3
17 number of IG.-current errors IG 4
18 number of IG.-current errors IG 5
19 number of IG.-current errors IG 6
20 number of IG.-current errors IG 7
21 number of IG.-current errors IG 8
22 number of IG.-voltage errors
23 number of display errors DISP1
24 number of display errors DISP2
25 number of time-out errors in the distance transmission
26 number of buffer overflow errors at DART
How to list the error statistic:
1 Display: P—
2 Input: 5 and ENTER
3 Display: P05 01<- register or number of error
XXX <- content of register
next register: see item 4
get out of register block: see item 5
4 Input: ENTER
5 Input: CLEAR (to get out of the register block)
6 Display: P—
3 Programming Page 14/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany

3.7 P22 Adjust the volume totalizer


Programming
Display : P—
Input : 22 and ENTER
Display : xx yy old value (xx assignment to the pulser e.g. 1)
yyyyyy yy totalizer value accurate for litre)
Input : press ENTER until the requested totalizer is shown
Input : Input of the start up value ( up to 8 digits )
Display : x yy
yyyyyy new value of the totalizer
Input : ENTER-key in order to select the next totalizer
Input : CLEAR-key finishes and stores the last input.
3.8 P23 Focusing the decimal places
Display: P—
Input: 23 and ENTER
Display: P23 x (blinking) up to date value of amount decimal place (0-3)
Input: ENTER
Display: P23 x
y (blinking) up to date value of volume decimal place (0-3)
Input: ENTER
Display: P23 x
y
z (blinking) up to date value of basic price decimal place (0-3)
3 Programming Page 15/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany

3.9 Overview Register 26 / 16


Register number Funktion Basic setting
Reg. 26 Reg. 16
01 time between two fuellings (3012)
02 maximum impulse sequence error (3)
03 external release (0)
04 maximum amount (litres) (990)
05 decimal places for DFU (3)
06 CRC-check for DFU (always 1)
07 display testing time (750ms each test) (450)
08 display suppress (imp.) (2)
09 DFU-kind (current-loop, DART) (0)
10 baud-rate (is not used) (0)
11 preset function (0)
12 preset function (selectable/obligatory) (0)
13 value of preset button 1 (0)
14 value of preset button 2 (0)
15 value of preset button 3 (0)
16 local setting for product A (52)
17 local setting for product B (52)
18 display test automatically (1)
19 3 minutes time circle, with 65353 no function (54180)
20 Product advised on display (0)
21 display operating (1=no zero-placement) (0)
22 delivery side A 60 l/min = 0,15 l/min = 1 (0)
23 delivery side B 60 l/min = 0,15 l/min = 1 (0)
24 reserved for Italy (0)
25 reserved for Italy (0)
3 Programming Page 16/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany
Register number Funktion Basic setting
26 01 hose watching for Italy (0)
27 02 BT-business (0)
28 03 display time of the preset values (0)
29 04 suppressing of impulse with hose extending (0)
30 05 display of filling rate (0)
31 06 zero fuelling at automatically use (0)
32
07
controls at RMI-business
(1=end of fuelling at end of barriereopening)
(0)
33 08 RMI-side (1, 2, 3) (0)
34 09 RMI-impulse form (0=standard, 1=BICA) (0)
35 10 RMI-impulse side standard (420)
36 11 RMI-impulse side BICA (840)
37 12 release 0- or 1 active (0)
38 13 reserved for DEBUG-function (0)
39 14 totalizer switched off = 0 (1)
40 15 flag for Austria at Austria = 1 (0)
41 16 overflow suppressing at preset (0)
42 17 DUO_12_6 for ELF (0)
43
18
equipment provided with pressure motor
5 seconds before magnet valve
(0)
44 19
45 20
46 21
47 22
48
49
50
3 Programming Page 17/17
File: BX268E02.doc
Abridged Description for Programming Revision : 1.0/18.12.1997
X2003-6/8 Computer Author : Wayne Germany