Catsloge
Catsloge
5 YEAR WARRANTY
Provided by Perfect Infraengineers on manufacturing defects
The HTS Panel harnesses the sun’s energy by reflecting the light on parabolic mirrored
concentrators. The light is focused on the copper pipes that are coated with specialized
absorption paint.
Based on the solar thermal intensity, refrigerant temperature and internal load, the advanced
microprocessor decides the modulation of the parabolic reflectors to ensure only adequate
heat is added at the most optimum operational point
This further heated refrigerant gas is returned from the panel outlet into the HVAC units
condenser
Due to the heat, the compressor needs to do less work in the next cycle, hence it slows down.
The reduction in RPM of the compressor correlates with the heat added by the HTS Panel
Hence, by adding heat using the HTS Panel, Perfect can reduce the electricity consumption
of any Inverter AC by 25-40%
Collector Case/Frame 100% Aluminium enclosure; 8011-H14 Aluminium; Size - 8ft x 4ft
Capacity One HTS Panel ideal for 7.5 tons / 10 HP / 90,000 BTU of cooling & heating
Weight / Dimensions Model no. PSP32, 86kg, 100" x 52" x 7"; Reflector area: 8ft x 4ft
Absorbers Copper tube: 5/8", 1-1/8"; Black selective paint: absorptivity .92/.96
Sun Trackers Two shaded phototransistors and brushless stepper motor; 12 vcd, 1.5w
Mounting Provisions Adjustable stand provided; Recessed lip on frame for clamping
MANUFACTURER
PULSAR
AERO - XRT - U524 24 27 - 33 ft | 8.2 - 10 m 137 1.65 28000 sq.ft. | 2602sq.m. 190 ft | 58 m
AERO - XRT - V520 20 27 - 33 ft | 8.2 - 10 m 130 1.555 21000 sq.ft. | 1951sq.m. 164 ft | 50 m
AERO - XRT - V518 18 24 - 30 ft | 7.3 - 9.1 m 127 1.094 16000 sq.ft. | 1486sq.m. 144 ft | 44 m
AERO - XRT - X516 16 24 - 30 ft | 7.3 - 9.1 m 120 1.525 16000 sq.ft. | 1486sq.m. 144 ft | 44 m
AERO - XRT - X512 12 24 - 30 ft | 7.3 - 9.1 m 99 0.749 8500 sq.ft. | 789sq.m. 104 ft | 32 m
STAR
AERO - XSG - S525 25 24 - 30 ft | 7.3 - 9.1 m 118 1.5 17500 sq.ft. | 1626sq.m. 150 ft | 46 m
AERO - XSG - S524 24 24 - 30 ft | 7.3 - 9.1 m 117 1.007 16000 sq.ft. | 1486sq.m. 144 ft | 44 m
AERO - XSG - T520 20 24 - 30 ft | 7.3 - 9.1 m 112 0.904 12000 sq.ft. | 1115sq.m. 124 ft | 38 m
AERO - XSG - T518 18 21 - 27 ft | 6.4 - 8.2 m 110 0.466 8500 sq.ft. | 789sq.m. 104 ft | 32 m
AERO - XSG - U516 16 21 - 27 ft | 6.4 - 8.2 m 104 0.661 8500 sq.ft. | 789sq.m. 104 ft | 32 m
AERO - XSG - V512 12 18 - 24 ft | 5.4 - 7.3 m 86 0.577 5500 sq.ft. | 511sq.m. 84 ft | 26 m
AERO - XSG - V510 10 18 - 24 ft | 5.4 - 7.3 m 83 0.4 2000 sq.ft. | 185sq.m. 52 ft | 16 m
* in every direction of unobstructed floor level ** recommended installation height
All data given above are under certain test conditions. Refer to Data sheet for more information.
HYDROFLOW
SUSTAINABLE CLEAN WATER TREATMENT TECHNOLOGY
Before After
GET IN TOUCH
J & J ENGINEERS
AHMEDABAD
Phone: +91-9033212414
Whatsapp: +91-9408391903
Mail: info@jandjengineers
Website: www.jandjengineers.in