0% found this document useful (0 votes)
11 views

360 Latest Error Code

360 error code

Uploaded by

NAMELESS ASHEN
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views

360 Latest Error Code

360 error code

Uploaded by

NAMELESS ASHEN
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 25

Errors

Jump to navigationJump to search

Errors

When if an error occurs on the Xbox 360, some segments of


the Ring of Light on the RF Board will be solid or flashing red.
Examining the LED pattern is used to determine the type of
error.

Contents
 1Failure Modes
o 1.1Xbox 360 (Original)
o 1.2Xbox 360 S and E
 2Error Behavior
o 2.1EC_BOOT
o 2.2EC_FATAL
o 2.3EC_THERMAL
o 2.4EC_XSS
 3UEM
 4Secondary Error Codes
o 4.1Instructions
o 4.2Xbox 360 (Original)
o 4.3Xbox 360 S
o 4.4Xbox 360 E
o 4.5SMC Errors
o 4.6XSS Errors
o 4.7XSS UEM Errors

Failure Modes
The general nature of the failure can be determined by
observing the red light lit on the front of the console. In order to
get the exact error, see Secondary Error Codes.
Xbox 360 (Original)
On the Original Xbox 360, the outer segments of the Ring of
Light flash red to indicate the failure mode.

Front Panel
Failure Mode
(Flashing)

AV Not Connected (Does not appear on HDMI consoles)

Thermal Overload

Core Digital/System Component Failure

Universal Error Message (UEM)

Xbox 360 S and E


On the Xbox 360 S and Xbox 360 E, the outer segments of
the Ring of Light can no longer turn red. Instead, the failure
mode is indicated by either a solid red or flashing red power
LED.

Front Panel Failure Mode


Solid:
Core Digital/System Component Failure
Universal Error Message (UEM)

Flashing:
Thermal Overload

Error Behavior
EC_BOOT
EC_BOOT is triggered when an error is detected by
the SMC which causes the console to not be able to continue
booting.
When an EC_BOOT error occurs, the SMC will reset and try
again up to 5 times. If the 5th attempt is not successful, the
console will remain in EC_BOOT.
The front panel indicates a Core Digital/System Component
Failure. The Secondary Error Code will reflect the error.
The console powered in this state indefinitely until a power off
event occurs, where the console will return to standby.
EC_FATAL
EC_FATAL is triggered by the SMC whenever a voltage
PWRGD (Power Good) signal is absent, or the temperature
data cannot be read from the ANA/HANA.
In either case, the console may be dangerous to operate. As a
result, when the SMC enters EC_FATAL, all devices will
immediately be shut down and all controllable voltages will be
turned off. The SMC does NOT wait for the DVD tray to close
so that the system powers down as quickly as possible.
During EC_FATAL, the front panel indicates a Core
Digital/System Component Failure. The Secondary Error
Code will reflect the error.
The console remains in this state indefinitely until a power off
event occurs, where the console will return to standby.
EC_THERMAL
EC_THERMAL is triggered when the CPU, GPU, or eDRAM
thermal diode exceeds its Thermal Trip Temperature. All
devices will immediately be shut down and all controllable
voltages except V_12P0 (which powers the fans) will be turned
off. The SMC does NOT wait for the DVD tray to close so that
the system powers down as quickly as possible.
The fans will run at full speed and power off events will be
ignored.
The console will wait in this state for any of the following to
occur:
 All thermal diodes reach safe levels
 Two minutes has passed
 A thermal diode continues to indicate overload for
more than 5 seconds
 An EC_FATAL error occurs
When any of the above occur, V_12P0 will be turned off. The
console will remain in this state indefinitely until a power off
event occurs, where the console will return to standby.
EC_XSS
EC_XSS is triggered when an error detected by the XSS is
reported to the SMC.
If the error occurs before the SMC and XSS handshake, the
SMC will reset and try again up to 5 times. If the 5th attempt is
not successful, the console will remain in EC_XSS.
If the error occurs after the handshake, the SMC will not retry
and remain in EC_XSS.
The front panel indicates a Core Digital/System Component
Failure or a Universal Error Message. The Secondary Error
Code will reflect the error. For some codes, a Universal Error
Message will be displayed on screen.
The console powered in this state indefinitely until a power off
event occurs, where the console will return to standby.

UEM
When a non-critical EC_XSS error occurs,
the Universal Error Message is shown on screen.
The message contains instructions to contact Xbox Support
and the Secondary Error Code will be displayed converted
from base-4 into decimal, with an E in front of it. For example,
the 1022 error will display "E 74".

The E 74 Universal Error Message

Secondary Error Codes


In addition to the nature of the failure, the console also
generates a Secondary Error Code which can be viewed on
the front panel Ring of Light.

0020 · 0021 · 0022 · 0023 · 0030 · 0031 · 0032 · 0033

1001 · 1002 · 1003 · 1010 · 1011 · 1012 · 1013 · 1020 · 1021 · 1022 · 1023 · 1030 · 1031 · 1032 · 1033 · 1100 · 1101 · 1102

71 · E 72 · E 73 · E 74 · E 75 · E 76 · E 77 · E 78 · E 79 · E 80 · E 81 · E 82

Instructions
Once the console enters a failure mode and the red lights are
displayed, the error code can be accessed via the following
procedure. Be sure to reference the table below to reliably
determine each value of the error code.
1. While holding sync, press the eject button once.
The first value of the error code is displayed.
2. Continuing to hold sync, press the eject button
again. The second value of the error code is
displayed.
3. Keep holding sync and press the eject button a
third time. The third value of the error code is
displayed.
4. While still holding sync, press the eject button a
fourth time. The fourth and final value of the error
code is displayed.
5. Holding sync and pressing the eject button a fifth
time causes display to return to the failure mode.
6. Look up the code in the database below.
Notes
 The value of the code may not change between
presses. For example, if the code is 0001, then
0, 0, 0, 1 will be displayed. It is important to take
note of the value on every eject button press.
 Confirming that the error code sequence exits
back to the failure mode with the fifth press of
eject while holding sync is useful to confirm all 4
values of the error code have been retrieved.
 For some reason in early 2006, Microsoft
changed the full ring of the secondary code to
mean 4 instead of 0, but we're going to keep the
meaning as 0 as this makes it easier to
understand. Microsoft appeared to continue
using 0 internally as well.
Xbox 360 (Original)
When retrieving the error code using the procedure above,
the values are displayed by the outer segments of the Ring
of Light rapidly flashing red.

Front
Panel
(Flashing)

Value 0 1 2 3

Xbox 360 S
When retrieving the error code using the procedure above,
the values are displayed by the outer segments of the Ring
of Light rapidly flashing green, as the outer segments can
no longer turn red.
Front
Panel
(Flashing)

Value 0 1 2 3

Xbox 360 E
The outer ring of the Ring of Light on the Xbox 360 E can
no longer light up in segments. When retrieving the error
code using the procedure above, the values are displayed
via the number of blinks. For example, if the ring blinks 2
times, and then pauses, and then blinks 2 times again, the
value is 2.

Front Panel
(Flashing)
1 blink 2 blinks 3 blinks 4 blinks

Value 1 2 3 0

SMC Errors
These errors are generated by the SMC.
0001
ANA_V12P0_PWRGD is driven high by
the ANA (later HANA) as long as the V_12P0 rail is within
tolerance. If V_12P0 ever drops out of tolerance, the signal
is de-asserted, causing the SMC to enter EC_FATAL and
the 0001 code to be displayed on the front panel.

Cod Common Repair


Hex Name Description Type
e Cause Guide

Bad
ERROR_V_12P ANA_V12P0_PWRGD Repair
0001 0x01 EC_FATAL power
0 negated unexpectedly Actions/0001
supply
0002
VREG_CPU_PWRGD is driven high by the V_CPUCORE
controller as long as the rail is within tolerance. If
V_CPUCORE ever drops out of tolerance, the signal is de-
asserted, causing the SMC to enter EC_FATAL and the
0002 code to be displayed on the front panel.

Cod Commo Repair


Hex Name Description Type
e n Cause Guide

VREG_CPU_PWRG Repair
0x0 ERROR_V_CPUCOR EC_FATA Bad
0002 D negated Actions/000
2 E L capacitor
unexpectedly 2

0003
Original Xbox 360:
VREG_GPU_PWRGD is driven high by the V_GPUCORE
controller as long as the rail is within tolerance. If
V_GPUCORE ever drops out of tolerance, the signal is de-
asserted, causing the SMC to enter EC_FATAL and the
0003 code to be displayed on the front panel.

Cod Commo Repair


Hex Name Description Type
e n Cause Guide

VREG_GPU_PWRG Repair
0x0 ERROR_V_GPUCOR EC_FATA Bad
0003 D negated Actions/000
3 E L capacitor
unexpectedly 3

Xbox 360 S and E:


VREG_V3P3_PWRGD is driven high by the V_3P3
controller as long as the rail is within tolerance. If V_3P3
ever drops out of tolerance, the signal is de-asserted,
causing the SMC to enter EC_FATAL and the 0003 code to
be displayed on the front panel.

Common Repair
Code Hex Name Description Type
Cause Guide

0003 0x03 ERROR_V_3P VREG_V3P3_PWRGD EC_FATAL Bad Repair


3 negated unexpectedly regulator Actions/0003

0010
The SMC communicates with the ANA/HANA via
the SMBus. If communication is lost, the SMC
enters EC_FATAL and the 0010 code is displayed on the
front panel.

Cod Common Repair


Hex Name Description Type
e Cause Guide

ANA/HANA is
ERROR_NO_ANA EC_FATA Bad Repair
0010 0x04 not responding to
ERROR_NO_HANA L ANA/HANA Actions/0010
reads or writes

0011
The SMC monitors the CPU thermal diode as reported by
the ANA/HANA. If the CPU temperature exceeds the Trip
Temperature defined in the SMC Config, the SMC
enters EC_THERMAL and the 0011 code is displayed on
the front panel.

Cod Descriptio Commo


Hex Name Type Repair Guide
e n n Cause

CPU Bad Repair


0x0 ERROR_THERMAL_CP EC_THERMA
0011 thermal thermal Actions/Therma
5 U L
overload paste l

0012
The SMC monitors the GPU thermal diode as reported by
the ANA/HANA. If the GPU temperature exceeds the Trip
Temperature defined in the SMC Config, the SMC
enters EC_THERMAL and the 0012 code is displayed on
the front panel.

Cod Descriptio Commo


Hex Name Type Repair Guide
e n n Cause

0012 0x0 ERROR_THERMAL_GP GPU EC_THERMA Bad Repair


thermal thermal Actions/Therma
6 U L
overload paste l

0013
The SMC monitors the eDRAM thermal diode as reported
by the ANA/HANA. If the eDRAM temperature exceeds
the Trip Temperature defined in the SMC Config, the SMC
enters EC_THERMAL and the 0013 code is displayed on
the front panel.

Cod Descriptio Commo


Hex Name Type Repair Guide
e n n Cause

eDRAM Bad Repair


0x0 ERROR_THERMAL_EDR EC_THERMA
0013 thermal thermal Actions/Therm
7 AM L
overload paste al

0020
After GPU power and clocking are available,
the SMC starts seqUnReset which releases the GPU from
reset. It then waits for the GPU to assert
GPU_RST_DONE. If the GPU_RST_DONE signal is not
asserted in the time allotted, EC_BOOT will be reported.
The SMC will retry 4 more times. If on the final attempt,
GPU_RST_DONE is still not asserted, the SMC remains in
EC_BOOT and the 0020 code is displayed on the front
panel.

Cod Commo Repair


Hex Name Description Type
e n Cause Guide

GPU_RST_DON
E signal not Repair
0x0 ERROR_GPU_RST_DON EC_BOO Bad
0020 asserted after Actions/002
8 E T GPU
seqUnReset time 0
passed

0021
After receiving GPU_RST_DONE during seqUnReset,
the SMC monitors the PCIe L0 status and waits for the link
to enter the L0 state. If the link does not enter the L0 state
in the time allotted, EC_BOOT will be reported. The SMC
will retry 4 more times. If on the final attempt, the link still
does not enter L0 state, the SMC remains in EC_BOOT
and the 0021 code is displayed on the front panel.

Cod Common
Hex Name Description Type Repair Guide
e Cause

PCIe link did not


enter L0 after Repair
0021 0x09 ERROR_NO_PCIE EC_BOOT Bad GPU
seqUnReset time Actions/0021
passed

0022
After the PCIe link has entered the L0 state
during seqUnReset, the SMC releases the CPU from reset.
The CPU will run the Bootloaders and start the XSS. When
the XSS starts, it will attempt to retrieve the power up
cause from the SMC. If the SMC does not receive
GetPowerUpCause in the time allotted, EC_BOOT will be
reported. The SMC will retry 4 more times. If on the final
attempt, GetPowerUpCause is still not received, the SMC
remains in EC_BOOT and the 0022 code is displayed on
the front panel.

Cod Commo Repair


Hex Name Description Type
e n Cause Guide

CPU did not send Bad Repair


0x0 ERROR_NO_HANDSHAK EC_BOO
0022 GetPowerUpCaus nand Actions/002
A E T
e to SMC image 2

0023
Xenon Original Xbox 360:
The SMC communicates with the Backup Clock
Generator via the SMBus. If communication is lost, the
SMC enters EC_FATAL and the 0023 code is displayed on
the front panel.

Cod Common Repair


Hex Name Description Type
e Cause Guide
Clock chip is
not
ERROR_NO_CLOCKCHI Bad clock Repair
0023 0x0B responding to EC_FATAL
P chip Actions/0023
reads or
writes

Xbox 360 S and E:


VREG_VEDRAM_PWRGD is driven high by the
V_CPUEDRAM controller as long as the rail is within
tolerance. If V_CPUEDRAM ever drops out of tolerance,
the signal is de-asserted, causing the SMC to
enter EC_FATAL and the 0023 code to be displayed on the
front panel.

Cod Commo Repair


Hex Name Description Type
e n Cause Guide

VREG_VEDRAM_PWR Bad Repair


002 0x0 ERROR_V_CPUEDR EC_FATA
GD negated capacito Actions/00
3 B AM L
unexpectedly r 23

0030
The SMC communicates with the ANA/HANA via
the SMBus. If the thermal registers read as zero, the SMC
enters EC_FATAL and the 0030 code is displayed on the
front panel.

Cod Common Repair


Hex Name Description Type
e Cause Guide

ANA/
HANA Bad Repair
0x0 ERROR_NO_TEMPERATUR EC_FATA
0030 temperature ANA/HAN Actions/003
C ES L
registers A 0
read as zero

0031
Original Xbox 360 (except Xenon):
VREG_V5P0_VMEM_PWRGD is driven high by the
V_5P0/V_MEM controller as long as the rail is within
tolerance. If V_5P0 or V_MEM ever drops out of tolerance,
the signal is de-asserted, causing the SMC to
enter EC_FATAL and the 0031 code to be displayed on the
front panel.

Comm
Cod Repair
Hex Name Description Type on
e Guide
Cause

Bad Repair
003 0x0 ERROR_V_5P0_V_ VREG_V5P0_VMEM_PW EC_FAT
regulato Actions/00
1 D MEM RGD negated unexpectedly AL
r 31

Xbox 360 S and E:


VREG_V5P0_PWRGD is driven high by the V_5P0
controller as long as the rail is within tolerance. If V_5P0
ever drops out of tolerance, the signal is de-asserted,
causing the SMC to enter EC_FATAL and the 0031 code to
be displayed on the front panel.

Cod Common Repair


Hex Name Description Type
e Cause Guide

ERROR_V_5P VREG_V5P0_PWRGD Bad Repair


0031 0x0D EC_FATAL
0 negated unexpectedly regulator Actions/0031

0032
Xbox 360 S and E:
VREG_CPUCORE_VCS_PWRGD is driven high by the
V_CPUVCS controller as long as the rail is within
tolerance. If V_CPUVCS ever drops out of tolerance, the
signal is de-asserted, causing the SMC to
enter EC_FATAL and the 0032 code to be displayed on the
front panel.

Commo
Cod Repair
Hex Name Description Type n
e Guide
Cause

003 0x0 ERROR_V_CPU VREG_CPUCORE_VCS_PW EC_FAT Bad Repair


2 E VCS RGD negated unexpectedly AL resistor Actions/00
32

0033
Xbox 360 S and E:
VREG_VMEM_PWRGD is driven high by the V_MEM
controller as long as the rail is within tolerance. If V_MEM
ever drops out of tolerance, the signal is de-asserted,
causing the SMC to enter EC_FATAL and the 0033 code to
be displayed on the front panel.

Cod Commo Repair


Hex Name Description Type
e n Cause Guide

Repair
0x0 ERROR_V_ME VREG_VMEM_PWRG EC_FATA Bad
0033 Actions/003
F M D negated unexpectedly L capacitor
3

XSS Errors
These errors are generated by the XSS and reported to
the SMC.
0100
The 2BL tries to retrieve the vendor ID from each memory
chip. If any of the IDs cannot be read or
mismatch, EC_XSS will be reported. The SMC will retry 4
more times. If on the final attempt, the IDs still cannot be
read or mismatch, the SMC remains in EC_XSS and the
0100 code is displayed on the front panel.

Cod Descriptio Commo Repair


Hex Name Type
e n n Cause Guide

Memory
vendor ID
Repair
0x1 ERROR_NBINIT_MEM_VENDOR_ read failed EC_XS Bad
0100 Actions/010
0 ID or S GPU
0
mismatche
d

0101
During 2BL memory initialization, if data cannot be written
for read strobe training, EC_XSS will be reported. The
SMC will retry 4 more times. If on the final attempt, data still
cannot be written, the SMC remains in EC_XSS and the
0101 code is displayed on the front panel.

Comm
Co He Descript Repair
Name Type on
de x ion Guide
Cause

Unable
to write
Repair
010 0x1 ERROR_NBINIT_MEM_READ_STROBE_D data for EC_X Bad
Actions/0
1 1 ATA_WRITE read SS GPU
101
strobe
training

0102
During 2BL memory initialization, if read strobe delay
training fails, EC_XSS will be reported. The SMC will retry
4 more times. If on the final attempt, training still fails, the
SMC remains in EC_XSS and the 0102 code is displayed
on the front panel.

Comm
Co He Descript Repair
Name Type on
de x ion Guide
Cause

Memory
read
Repair
010 0x ERROR_NBINIT_MEM_READ_STROBE_DE strobe EC_X Bad
Actions/0
2 12 LAY_TRAINING delay SS GPU
102
training
failed

0103
During 2BL memory initialization, if write strobe delay
training fails, EC_XSS will be reported. The SMC will retry
4 more times. If on the final attempt, training still fails, the
SMC remains in EC_XSS and the 0103 code is displayed
on the front panel.

Co He Name Descript Type Comm Repair


on
de x ion Guide
Cause

Memory
write
Repair
010 0x ERROR_NBINIT_MEM_WRITE_STROBE_DE strobe EC_X Bad
Actions/0
3 13 LAY_TRAINING delay SS GPU
103
training
failed

0110
During 2BL memory initialization, if a memory addressing
line fails, EC_XSS will be reported. The SMC will retry 4
more times. If on the final attempt, a memory addressing
line still fails, the SMC remains in EC_XSS and the 0110
code is displayed on the front panel.

Cod Commo Repair


Hex Name Description Type
e n Cause Guide

Memory
address line Repair
0x1 ERROR_MEMORY_ADDRESSIN EC_XS Bad
0110 failed or Actions/011
4 G S GPU
unresponsiv 0
e

0111
During 2BL memory initialization, if a memory data line
fails, EC_XSS will be reported. The SMC will retry 4 more
times. If on the final attempt, a memory data line still fails,
the SMC remains in EC_XSS and the 0111 code is
displayed on the front panel.

Cod Common Repair


Hex Name Description Type
e Cause Guide

Memory data
EC_XS Repair
0111 0x15 ERROR_MEMORY_DATA line failed or Bad GPU
S Actions/0111
unresponsive
XSS UEM Errors
These errors are generated by the XSS and reported to
the SMC. If possible, the UEM is displayed.
1000
Occurs if kernel communications to the DVD drive time out.
The SMC enters EC_XSS, the E 64 UEM will be displayed,
and the 1000 code is displayed on the front panel.

Comm
Cod He UE Repair
Name Description Type on
e x M Guide
Cause

Kernel DVD
Bad Repair
100 0x4 ERROR_XSS_CDROM_TIME drive EC_X
E 64 DVD Actions/10
0 0 D_OUT communicati SS
drive 00
ons timed out

1001
Occurs if the kernel cannot configure the DVD drive for
Direct Memory Access mode. The SMC enters EC_XSS,
the E 65 UEM will be displayed, and the 1001 code is
displayed on the front panel.

Comm
Co He UE Descript Repair
Name Type on
de x M ion Guide
Cause

Kernel
could not
configur Bad Repair
100 0x4 E ERROR_XSS_CDROM_NOT_DMA_C EC_X
e DVD DVD Actions/1
1 1 65 ONFIGURED SS
drive for drive 001
DMA
mode

1002
Occurs if the kernel cannot create a device instance for
the DVD drive. The SMC enters EC_XSS, the E
66 UEM will be displayed, and the 1002 code is displayed
on the front panel.

Co He UE Name Descrip Type Com Repair


mon
de x M tion Guide
Cause

Kernel
could
not Bad Repair
100 0x E ERROR_XSS_CDROM_COULD_NOT_C EC_X
create DVD Actions/
2 42 66 REATE_DEVICE SS
DVD drive 1002
drive
instance

1003
Occurs if kernel communications to the hard drive time out.
The SMC enters EC_XSS, the E 67 UEM will be displayed,
and the 1003 code is displayed on the front panel.

Cod UE Commo Repair


Hex Name Description Type
e M n Cause Guide

Kernel HDD Bad Repair


100 0x4 ERROR_XSS_HDD_TIMED_ EC_XS
E 67 communicatio hard Actions/10
3 3 OUT S
ns timed out drive 03

1010
Occurs if the kernel cannot configure the hard drive for
Direct Memory Access mode. The SMC enters EC_XSS,
the E 68 UEM will be displayed, and the 1010 code is
displayed on the front panel.

Comm
Co He UE Descript Repair
Name Type on
de x M ion Guide
Cause

Kernel
could not
Bad Repair
101 0x4 E ERROR_XSS_HDD_NOT_DMA_CO configure EC_X
hard Actions/1
0 4 68 NFIGURED HDD for SS
drive 010
DMA
mode

1011
Occurs if the kernel cannot create a device instance for
the hard drive. The SMC enters EC_XSS, the E
69 UEM will be displayed, and the 1011 code is displayed
on the front panel.

Comm
Co He UE Descript Repair
Name Type on
de x M ion Guide
Cause

Kernel
could
Bad Repair
101 0x E ERROR_XSS_HDD_COULD_NOT_CR not EC_X
hard Actions/1
1 45 69 EATE_DEVICE create SS
drive 011
HDD
instance

1012
Occurs if a hard drive is detected, but the kernel cannot
find or access it. The SMC enters EC_XSS, the E
70 UEM will be displayed, and the 1012 code is displayed
on the front panel.

Cod UE Descriptio Commo Repair


Hex Name Type
e M n n Cause Guide

Kernel
Bad Repair
101 0x4 ERROR_XSS_HDD_NOT_FO couldn't EC_XS
E 70 hard Actions/10
2 6 UND find the S
drive 12
HDD

1013
Occurs if XAM cannot find a dashboard (dash.xex) to load
from the nand. The SMC enters EC_XSS, the E
71 UEM will be displayed, and the 1013 code is displayed
on the front panel.

Cod UE Descriptio Commo Repair


Hex Name Type
e M n n Cause Guide

1013 0x4 E 71 ERROR_XSS_XAM_NO_DA XAM EC_XS Bad Repair


7 SH could not S nand Actions/101
find a dash
to load 3

1020
Occurs if the SMC Config on the nand is missing or corrupt.
The SMC enters EC_XSS, the E 72 UEM will be displayed,
and the 1020 code is displayed on the front panel.

Comm
Cod He UE Descripti Repair
Name Type on
e x M on Guide
Cause

SMC
configurat Bad Repair
102 0x4 ERROR_SMC_FLASH_CONFIG_C EC_X
E 72 ion area in nand Actions/1
0 8 ORRUPT SS
the nand is image 020
corrupt

1021
Occurs if the HSIO training fails due to an unresponsive or
malfunctioning eDRAM. The SMC enters EC_XSS, the E
73 UEM will be displayed, and the 1021 code is displayed
on the front panel.

Cod UE Descripti Commo Repair


Hex Name Type
e M on n Cause Guide

GPU to
eDRAM
Repair
102 0x4 ERROR_HSIO_TRAINING_FAI High EC_XS Bad
E 73 Actions/HSI
1 9 LED Speed S GPU
O
Link
failed

1022
Original Xbox 360:
Occurs if the HSIO calibration fails due to an unresponsive
or malfunctioning eDRAM. The SMC enters EC_XSS, the E
74 UEM will be displayed, and the 1022 code is displayed
on the front panel.

Cod Hex UE Name Descripti Type Comm Repair


on
e M on Guide
Cause

GPU to
eDRAM
Repair
102 0x4 ERROR_HSIO_CALIBRATION_F High EC_X Bad
E 74 Actions/HS
2 A AILED Speed SS GPU
IO
Link
failed

1023
Occurs if the Southbridge can't communicate with
the Ethernet PHY, or the vendor ID of the PHY is incorrect.
The SMC enters EC_XSS, the E 75 UEM will be displayed,
and the 1023 code is displayed on the front panel.

Com
Co He UE Descripti Repair
Name Type mon
de x M on Guide
Cause

Southbrid
ge could
not
communi
Bad Repair
102 0x4 E ERROR_UNEXPECTED_ETHERNET_ cate with EC_X
ethern Actions/1
3 B 75 PHY_VENDOR Ethernet SS
et chip 023
PHY
over
MDIO/M
DC

1030
Occurs if the Ethernet PHY does not complete the reset
sequence properly. The SMC enters EC_XSS, the E
76 UEM will be displayed, and the 1030 code is displayed
on the front panel.

Comm
Cod UE Descripti Repair
Hex Name Type on
e M on Guide
Cause

103 0x4 E 76 ERROR_ETHERNET_PHY_RESE Ethernet EC_X Bad Repair


0 C T_FAIL PHY ethernet Actions/10
failed to
complete SS chip 30
reset

1031
Occurs if the Southbridge can't read from or write to
the Ethernet PHY. The SMC enters EC_XSS, the E
77 UEM will be displayed, and the 1031 code is displayed
on the front panel.

Comm
Co He UE Descript Repair
Name Type on
de x M ion Guide
Cause

Could
not read
Bad Repair
103 0x4 E ERROR_ETHERNET_PHY_READ_W from or EC_X
etherne Actions/1
1 D 77 RITE_FAIL write to SS
t chip 031
Ethernet
PHY

1032
Occurs if the GPU design revision is unsupported by
the kernel. The SMC enters EC_XSS, the E 78 UEM will be
displayed, and the 1032 code is displayed on the front
panel.

Cod UE Descriptio Commo Repair


Hex Name Type
e M n n Cause Guide

GPU is
wrong Repair
0x4 ERROR_UNSUPPORTED_G EC_XS Kernel
1032 E 78 revision Actions/103
E PU S too old
and not 2
supported

1033
Occurs if XAM cannot found on the nand.
The SMC enters EC_XSS, the E 79 UEM will be displayed,
and the 1033 code is displayed on the front panel.

Cod Hex UE Name Descriptio Type Commo Repair


e M n n Cause Guide

XAM
could not Repair
0x4 ERROR_XSS_FLASH_NO_X EC_XS Bad
1033 E 79 be found Actions/103
F AM S nand
on the 3
nand

1100
To be determined.
1101
Occurs if a write to the nand fails.
The SMC enters EC_XSS, the E 81 UEM will be displayed,
and the 1101 code is displayed on the front panel.

Cod Common Repair


Hex UEM Name Description Type
e Cause Guide

Unknow XeKeysSecuritySaveSettings Repair


1101 0x51 E 81 EC_XSS Bad nand
n failed Actions/1101

1102
Xbox 360 S and E:
Occurs if the HSIO calibration fails due to an unresponsive
or malfunctioning eDRAM. The SMC enters EC_XSS, the E
82 UEM will be displayed, and the 1102 code is displayed
on the front panel.

Comm
Cod He UE Descripti Repair
Name Type on
e x M on Guide
Cause

CGPU to
eDRAM
Repair
110 0x5 ERROR_HSIO_CALIBRATION_F High EC_X Bad
E 82 Actions/HS
2 2 AILED Speed SS GPU
IO
Link
failed
odes · Behavior · Secondary Codes) · Post Codes

PU Retrofit · No Power · Thermal Overload

Category:
 Articles using infobox templates with no data rows

Navigation menu
 Log in
 Page
 Discussion
 Read
 View source
 View history
Search
Search Go

Main page
 Recent changes
 Random page
 Donate to XenonLibrary
 About XenonLibrary
Tools
 What links here
 Related changes
 Special pages
 Printable version
 Permanent link
 Page information
Categories
 Consoles
 Console Components
 Motherboard Components
 Debug and Repair
 Software
Links
 ConsoleMods Wiki
 Josh's YouTube
 XenonLibrary on X
 XenonLibrary YouTube
 This page was last edited on 7 August 2024, at 16:19.
 Content is available under Creative Commons CC BY-NC-SA 4.0 unless otherwise noted.
 Privacy policy

 About XenonLibrary

 Disclaimers

You might also like