MSZ-GS12NA & MUZ-GS12NA

12,000 BTU/H WALL-MOUNTED INDOOR UNIT


12,000 BTU/H HEAT PUMP OUTDOOR UNIT

Job Name:
System Reference: Date:

Indoor Unit MSZ-GS12NA

Outdoor Unit MUZ-GS12NA

INDOOR UNIT FEATURES


• Slim wall-mounted indoor units provide zone comfort control
• Dual Barrier Coating applied to the heat exchanger, vanes and fan to prevent hydrophilic and hydrophobic dirt build-up
• Optional Microparticle Filter designed to capture PM2.5
• The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns
• Quiet operation
• Smart Set: recalls a preferred preset temperature setting at the touch of a button
• Built-in backup/auxiliary heater control available
• Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto
• Multiple control options available:
○ Back-lit screen handheld remote controller (provided with the unit)
○ kumo cloud® smart device app for remote access
○ Third-party interface options
○ Wired or wireless controllers

OUTDOOR UNIT FEATURES


• INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance
• Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life
○ Rated for 2,000 hours spraying time per ASTM B117 Standard

Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
SPECIFICATIONS: MSZ-GS12NA & MUZ-GS12NA
test

Maximum Capacity BTU/H 13,600


Rated Capacity BTU/H 12,000
Minimum Capacity BTU/H 1,500
Maximum Power Input W 1,450
Cooling at 95°F1
Rated Power Input W 920
Moisture Removal Pints/h 2.5
Sensible Heat Factor 0.77
Power Factor [208V / 230V] % 95.0 / 95.0
Maximum Capacity BTU/H 18,100
Rated Capacity BTU/H 14,400
Minimum Capacity BTU/H 2,000
Heating at 47°F2
Maximum Power Input W 1,750
Rated Power Input W 1,100
Power Factor [208V / 230V] % 97.0 / 97.0
Maximum Capacity BTU/H 12,000
Rated Capacity BTU/H 9,000
Heating at 17°F3
Maximum Power Input W 1,670
Rated Power Input W 1,000
Maximum Capacity BTU/H 9,540
Heating at 5°F4
Maximum Power Input W 1,540
SEER | SEER2 23.1 | 25.6
EER1 | EER21 13.05 | 13.05
HSPF [IV] | HSPF2 [IV] 13.2 | 10.7
Efficiency COP at 47°F2 3.84
COP at 17°F at Maximum Capacity3 2.11
COP at 5°F at Maximum Capacity4 1.82
ENERGY STAR® Certified Yes
Voltage, Phase, Frequency 208/230, 1, 60
Guaranteed Voltage Range V AC 187 - 253
Voltage: Indoor - Outdoor, S1-S2 V AC 208/230
Voltage: Indoor - Outdoor, S2-S3 V DC 24
Electrical
Short-circuit Current Rating [SCCR] kA 5
Recommended Fuse/Breaker Size (Outdoor) A 15
Recommended Wire Size [Indoor - Outdoor] AWG 14
Power Supply Indoor unit is powered by the outdoor unit
MCA A 1.0
Fan Motor Full Load Amperage A 0.75
Fan Motor Output W 30
Airflow Rate at Cooling, Dry CFM 134–160–222–307–381
Airflow Rate at Cooling, Wet CFM 121–144–200–276–343
Airflow Rate at Heating, Dry CFM 134–160–222–307–390
Sound Pressure Level [Cooling] dB[A] 19–22–30–37–45
Indoor Unit Sound Pressure Level [Heating] dB[A] 19–22–30–37–43
Drain Pipe Size In. [mm] 5/8 [15.88]
Coating on Heat Exchanger Dual Barrier Coating
External Finish Color Munsell 1.0Y 9.2/0.2
Unit Dimensions W x D x H: In. [mm] 31-7/16 x 9-1/8 x 11-5/8 [798 x 232 x 295]
Package Dimensions W x D x H: In. [mm] 33-1/2 x 12 x 14 [850 x 300 x 350]
Unit Weight Lbs. [kg] 23 [10.4]
Package Weight Lbs. [kg] 26 [11.5]
Indoor Unit Operating Temperature Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 73 WB / 67 DB, 57 WB
Range Heating Intake Air Temp [Maximum / Minimum] °F 80 DB / 70 DB

NOTES:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a fixed compressor speed) 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB

Conditions 4
Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
5
Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB
7
Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB

*Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
• Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.

**Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
SPECIFICATIONS: MSZ-GS12NA & MUZ-GS12NA
test

MCA A 10.0
MOCP A 15
Fan Motor Full Load Amperage A 0.5
Fan Motor Output W 55
Refrigerant Control Linear expansion valve
Defrost Method N/A
Sound Pressure Level, Cooling1 dB(A) 49
Sound Pressure Level, Heating2 dB(A) 51
Compressor Type DC inverter driven Twin Rotary
Outdoor Unit
Compressor Model SNB092FQAMT
Compressor Rated Load Amps A 6.72
Compressor Locked Rotor Amps A 8.4
External Finish Color Munsell 3Y 7.8/1/1
Base Pan Heater Optional
Unit Dimensions W x D x H: In. [mm] 31-1/2 x 11-1/4 x 21-5/8 [800 x 285 x 550]
Package Dimensions W x D x H: In. [mm] 37 x 15 x 24-1/2 [980 x 380 x 630]
Unit Weight Lbs. [kg] 79 [35.8]
Package Weight Lbs. [kg] 87 [39.2]
Cooling Air Temp [Maximum / Minimum]* °F 115 DB / 14 DB
Outdoor Unit Operating Temperature Cooling Thermal Lock-out / Re-start Temperatures** °F -4 / 0
Range Heating Air Temp [Maximum / Minimum] °F 75 DB, 65 WB / -4 DB, -5 WB
Heating Thermal Lock-out / Re-start Temperatures** °F -14 / -4
Type R410A
Pre-Charged Refrigerant Amount Lbs, oz 2.0, 9.0
Refrigerant
Maximum Pre-Charged Piping Length Ft. [m] 25.0 [7.5]
Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 1.08 [20]
Gas Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52]
Liquid Pipe Size O.D. [Flared] In.[mm] 1/4 [6.35]
Piping Maximum Piping Length Ft. [m] 65 [20]
Maximum Height Difference Ft. [m] 40 [12]
Maximum Number of Bends 10

NOTES:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a fixed compressor speed) 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB

Conditions 4
Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
5
Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB
7
Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB

*Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
• Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.

**Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
INDOOR UNIT ACCESSORIES: MSZ-GS12NA

CN24 Relay Kit □ CN24RELAY-KIT-CM3


IT Extender □ PAC-WHS01IE-E
kumo station® for kumo cloud® □ PAC-WHS01HC-E
Procon BACnet® and Modbus® Interface □ PAC-UKPRC001-CN-1
Control Interface
System Control Interface □ MAC-334IF-E
Thermostat Interface □ PAC-US445CN-1
USNAP Adapter □ PAC-WHS01UP-E
Wireless Interface for kumo cloud® □ PAC-USWHS002-WF-2
Wired Remote Sensor □ M21EAA307
Remote Sensor
Wireless temperature and humidity sensor for kumo cloud® □ PAC-USWHS003-TH-1
Deluxe Wired MA Remote Controller† □ PAR-40MAAU
Simple Ductless Wired Remote Controller □ PAC-SDW01RC-1
Wired Remote Controller
Simple MA Remote Controller† □ PAC-YT53CRAU-J
Touch MA Controller† □ PAR-CT01MAU-SB
kumo touch™ RedLINK™ Wireless Controller □ MHK2
Wireless Remote Controller
Lockdown bracket for remote controller □ RCMKP1CB
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] □ X87-721
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor □ X87-835
Blue Diamond Alarm Extension Cable — 6.5 Ft. □ C13-192
Blue Diamond MultiTank — collection tank for use with multiple pumps □ C21-014
Blue Diamond Sensor Extension Cable — 15 Ft. □ C13-103
Condensate
Drain Pan Level Sensor/Control □ SS610E
Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit □ T18-016
Refco Condensate Pump (100-240 VAC) □ GOBI-II
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H □ COMBI
Sauermann Condensate Pump □ SI30-230
(30A/600V/UL) [fits 2” X 4” utility box] - Black □ TAZ-MS303
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - White □ TAZ-MS303W
Anti-allergy Enzyme Filter □ MAC-408FT-E
Filter
Microparticle (PM2.5) Filter □ MAC-EMF515FT-E

NOTES:

PAC-SF40RM-E (Unable to use with wireless remote controller)

Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
OUTDOOR UNIT ACCESSORIES: MUZ-GS12NA

Hail Guards Hail Guard □ HG-B4


15’ x 1/4” x 15’ / 3/8” Lineset (Twin-Tube Insulation) □ MLS143812T-15
30’ x 1/4” x 30’ / 3/8” Lineset (Twin-Tube Insulation) □ MLS143812T-30
Lineset
50’ x 1/4” x 50’ / 3/8” Lineset (Twin-Tube Insulation) □ MLS143812T-50
65’ x 1/4” x 65’ / 3/8” Lineset (Twin-Tube Insulation) □ MLS143812T-65
Condensing Unit Mounting Pad: 16” x 36” x 3” □ ULTRILITE1
Mounting Pad
Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic □ DSD-400P
Optional Defrost Heater Optional Defrost Heater □ MAC-640BH-U
18” Single Fan Stand □ QSMS1801M
24” Single Fan Stand □ QSMS2401M
Stand Condenser Wall Bracket □ QSWB2000M-1
Condenser Wall Bracket - Stainless Steel Finish □ QSWBSS
Outdoor Unit Stand — 12” High □ QSMS1201M

Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
INDOOR UNIT DIMENSIONS: MSZ-GS12NA

Unit: inch

2-3/8 3/4
7-5/8

Insulation ø1 - 9/16 O.D


Piping

Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4)


Gas line ø3/8 16 - 15/16
(Flared connection: ø3/8 (GS06/09/12NA), ø1/2 (GS15NA))
Wireless remote Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D
controller

Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
OUTDOOR UNIT DIMENSIONS: MUZ-GS12NA

Unit: inch

REQUIRED SPACE
*1 4 in. or more when

clear *1
front and sides of the unit are clear

ore
4 in orm
. or
4 in.
mo
re

(09/12/15 Btu/h)

*2 14
ore in.
rm or m
8i n. o ore

*2 When any 2 sides of left, right


and rear of the unit are clear

holes

Liquid refrigerant pipe joint


Refrigerant pipe (flared) Ø 1/4
Gas refrigerant pipe joint
Refrigerant pipe (flared) Ø 3/8 (09/12 KBTU/H)
Ø 1/2 (15 KBTU/H)

1340 Satellite Boulevard Suwanee, GA 30024


Toll Free: 800-433-4822 www.mehvac.com

FORM# MSZ-GS12NA & MUZ-GS12NA - 202311

Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.