DELTA VF MD Drive MANUAL For Encoder
DELTA VF MD Drive MANUAL For Encoder
Door feedback signals: Door close limit signal-RC1 (com), RB1 (NC), RA1
(no), Door open limit signal-RC2 (com), RA2 (no)
Drive program:
User parameters:
Basic parameters:
Motor auto tuning –put 0-12-0, then press run command for auto tuning.
After this check motor direction by press run command door should close
.if direction reverse interchange two motor wires and repeat motor tuning
again
3-00 -6, 3-01-20, 3-02 -20, 3-03 -90, 3-04-6.0, 3-05-95, 3-06-4.0, 3-12-20,
3`-17-999.9
Door close control parameters:
4-00 -18.0, 4-01-15.0, 4-02 -6.0, 4-03 -5.0, 4-04-4.0, 4-15-20, 4-22-999.9
Door width tuning process: 1.put door in half position ,after this enter
parameter 0-12-0, 2-23-1 then give run command ( in this time the door
open and close completely ) if tuning complete successfully ok .go to step3.
Note: for reset the drive put parameter 0-02-09 (for restore the parameters
into default values.)