Open navigation menu
Close suggestions
Search
Search
en
Change Language
Upload
Sign in
Sign in
Download free for days
0 ratings
0% found this document useful (0 votes)
35 views
PSA2-TestNo 2
Power System Analysis
Uploaded by
Doba
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save PSA2-TestNo.2 For Later
Download
Save
Save PSA2-TestNo.2 For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
0 ratings
0% found this document useful (0 votes)
35 views
PSA2-TestNo 2
Power System Analysis
Uploaded by
Doba
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save PSA2-TestNo.2 For Later
Carousel Previous
Carousel Next
Save
Save PSA2-TestNo.2 For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
Download now
Download
You are on page 1
/ 38
Search
Fullscreen
Question 5 Correct Mark 1.00 out of 1.00 Y Flag question A 500 MW, 21 KV, 50 Hz, 3-phase, 2- pole synchronous generator having arated p.f. =0.9 has a moment of inertia of 27.5 x 10° kg-m*. The inertia constant (H) will be a. 488s b. 5.42s Coe 7is d. 244s Ss Your answer is correct. The correct answer is: 2.44 s7 2 GH H=? Ee Rot _ 10x50 mn o us E RDELO = Booo?P o ge Pf 24 “4 Z 025» 24-54 18x Gooor MO”, 24 x2tlbe) jos Za 5ooe q = a 0 7Question 6 Correct Mark 1.00 out of 1.00 Y Flag question The inertia constant of a 100 MVA, 50 Hz, 4-pole generator is, 10 MJ/MVA. If the mechanical input to the machine is suddenly raised from 50 MW to 75 MW, the rotor acceleration will be equal to a. 225 electrical degree/s*¥yv b. 125 electrical degree/s? c. 12.5 electrical degree/s* d. 22.5 electrical degree/s* Your answer is correct. The correct answer is: 225 electrical degree/s2fae ch ds = IBof gee 8 1 dS 2 Ralbed _ axe Bor’ _ 225 cle dope bt oP ee los «A generator A is rated at 50 Hz, 60 MW, 75 MVA, 1500 rpm and has an inertia constant H = 7 MJ/MVA. The corresponding data for another generator B is 50 Hz, 120 MW, 133.3 MVA, 3000 rpm, and 4 MJ/MVA. (a) If these two generators operate in parallel in a power station, calculate H for the equivalent generator on a base of 100 MVA. (b) If the power station is connected to another power station which has two of each type of generator, calculate H, for the equivalent generator connected to an infinite bus bar. (a) H= 10 32 MJ/MVA ” < (b)He= | 7.05 ~ )/MVA a> Your answer is correct. The correct answer is: (a) H = — 10.582 MJ/MVA, (b) He = = 7.055 MJ/MVAGes Ha E476 + H9 189-3 = Jo-5RR My/MvA loo a y= TCE Hels 2 OR loo y= 2-4 MT/MvA he KH. «Ar = 44, =lo- ey ea . = 10-582 Jo-5gax riley oy oan bee eae VT ospgn + 211+Question 11 Correct Mark 1.00 out of 1.00 Y Flag question A synchronous generator with a synchronous reactance of 1.3 puis connected to an infinite bus whose voltage is 1 pu, through an equivalent reactance of 0.2 pu. For maximum output of 1.2 pu, the alternator emf must be a. 1.56 pu b. 1.8 pugy c. 2.5 pu d. 1.5 pu Your answer is correct. The correct answer is: 1.8 puQuestion 19 Correct Mark 1.00 out of 1.00 Y Flag question The inertia constant of a 100 MVA, 11 kV water-wheel generator is 4. The energy stored in the rotor at the synchronous speed is a. 400kJ b. 25kJ c. 400M vv d. 25MJ Your answer is correct. The correct answer is: 400 MJaa ) 0 7 a CG = 6Question 22 Correct Mark 1.00 out of 1.00 Y Flag question A round rotor generator with internal voltage E1=2.0 p.u. and X=1.1 p.u. is connected to a round rotor synchronous motor with internal voltage E2=1.3 p.u. and X=1.2 p.u. Th e reactance of the line connecting the generator to the motor is 0.5 p.u. When the generator supplies 0.5 p.u. power, the rotor angle difference between the machines will be a. 122.58° b. 57.42° C. 32.589 yw ie Your answer is correct. The correct answer is: 32.58°ae Quint tho Ea 13 R= °-5pa, X= L[bo54h 2a 2-Be-4 Coe es = > 6m5 1-3 &QQuestion 23 Correct Mark 1.00 out of 1.00 Y Flag question If a generator of 250 MVA rating has an inertia constant of 6 MJ/MVA, its inertia constant on 100 MVA base is a. 2.5 pu b. 6MJ/MVA c. 15MJ/MVA ey d. 10.5 MJ/MVA Your answer is correct. The correct answer is: 15 MJ/MVA6 e 250 [ao 15 My /MvaQuestion 24 Correct Mark 1.00 out of 1.00 Y Flag question Two synchronous machines of equal rating have internal voltages of 1.1 + j0.5 and 0.8 — j0.4 per unit voltages respectively. The machines are connected by a line of 50 km length having only reactance and the second machine receives power of 0.9 per unit. Then, the reactance of the line per km length. Assume that there is no internal reactance for simplification. a. 0.8986 p.u b. 0.02986 p.u c. 1.594 p.u d. 0.0186 pugy Your answer is correct. The correct answer is: 0.0186 p.u— Gs 455g f pS Ok-onys + 30 km-> : Pe o-Tp-u ‘Es 1-208 24.’ : bE on apy [26 = CMe goss x Xa 1RoB xo-38T4 Pe EIS asin = A a Ra Sin AA-Aay ~ Cre.5ds5) ooo ae 0-983 = 0.01866 py X perm = EG ——Question 25 Correct Mark 1.00 out of 1.00 Y Flag question An alternator having induced emf. of 1.6 p.u. is connected to an infinite bus of 1.0 p.u. If the busbar has reactance of 0.6 p.u. and alternator has reactance of 0.2 p.u., the maximum power that can be transferred is given by a 2plieys b. 2.67 p.u. 5.0 p.u. d. 8p.u. Your answer is correct. The correct answer is: 2 p.u.AF oQ 06 vel FG at6 Qn ENV [-6%*] = 2 PY “K e8 yQuestion 29 Correct Mark 1.00 out of 1.00 Y Flag question An 800 kV transmission line has a maximum power transfer capacity on the operated at 400 kV with the series reactance unchanged, the new maximum power transfer capacity is approximately a. 2P b. P P/4yp d. P/2 Your answer is correct. The correct answer is: P/4ae Q Prax & V BoM Bh estA generator with constant 1.0 p.u. terminal voltage supplies power through a step-up transformer of 0.12 p.u. reactance and a double- circuit line to an infinite bus has as shown in figure. Th e infinite bus voltage is maintained at 1.0 p.u. Neglecting the resistances and susceptances of the system, the steady state stability power limit of the system is 6.25 p.u. If one of the double circuits is tripped, the resulting steady state stability power limit in p.u. will be ® a. 10.0p.u b. 12.5 p.u c. 5.0 ply d. 3.125 p.u Your answer is correct. The correct answer is: 5.0 p.u® io a x Vy = Tpey x, P= “2% J AIX Il | Be ~o I = oof S X=0-08py at rh one of Parahel lines is +i pped 318 0-08 eee | i 2-12 0-08 ae arQuestion 35 Correct Mark 1.00 out of 1.00 Y Flag question A power station with 4 generators each 80 MVA, 8 MJ/MVA is in proximity with another power station having 3 generators each 200 MVA, 3.5 MJ/MVA. then, the inertia constant of a single equivalent machine for use in stability studies is. Assume a base value of 100 MVA. a. 180 MJ/MVA b. 3.78 MJ/MVA Cc. 46.6 MJ/MVAgye d. 65 MJ/MVA Your answer is correct. The correct answer is: 46.6 MJ/MVA35— H= Hit GEE + Has Srache Hi bGracky + Ha Grech ee G system Eyam +2 = 80% BFA tRoO*B543 = HG my /mvn looQuestion 39 Correct Mark 1.00 out of 1.00 Y Flag question The moment of inertia of a 4 pole, 100 MVA, 11 kV, 3-phase, 0.8 power factor, 50 Hz turbo alternator is 10000 kg:m?. Then, the value of H and and M are H | 1.2337 MJ/MVA
Your answer is correct. The correct answer is: H = - 1.2337 MJ/MVA, M = = 0.0137 MJ.s /electrical degreew= Roxso _ IBeoxpm = LE = GH= Ly or 5H = 2s hoon (ior Bice aS ? Deb haa3y loo He! 2334 my Java Me GH = toon |-233% ; ; igo d ee ela mys [clectrial degreeQuestion 41 Correct Mark 1.00 out of 1.00 Y Flag question If the inertia constant H of a machine of 200 MVA is 2 p.u. its value corresponding to 400 MVA will be: a. 0.5p.u b. 2p.u 4p.u d. 1.0 PU Your answer is correct. The correct answer is: 1.0 p.uA 50 Hz, 4 pole, turbo alternator tated 100 MVA, 11 kV has an inertia constant of 8 MJ/MVA. Then, 1. The energy stored in the rotor at synchronous speed is . 2. The rotor acceleration if the mechanical input is suddenly raised to 80 MW for an electric load of 50 MWis....... (Neglect mechanical and electrical losses). Acceleration | 337.5 Electrical degree/s x 800 MJ Choose... The energy stored in the 800 MJ rotor at synchronous o speed = Your answer is partially correct. You have correctly selected 1. The correct answer is: Acceleration = = 100 MJ, 800 MJ — 1200, The energy stored in the rotor at synchronous speed = — 800 MJI- €-E = Gta Baloo = Boa Ny 2 Gl gis poe | des IBo#d leo Ga” o> Ge = (ee -bode 2d : d*s = 334-5 cleo. clegree [s% d®Question 45 Incorrect Mark 0.00 out of 1.00 Y Flag question The power angle characteristic of machine-infinite bus system is P, =2 sin 6 pu It is operating at 6 = 30°. Which one of the following is the synchronising power coefficient at the operating point ? a. 1/v3 b. 2.0 c. v3 d. 10, Your answer is incorrect. The correct answer is: V34B oe + syrohroniting Poorer is dedineal as the change in “the sgnchronous Power P torts respect the Chensg. Poors. load ang S$. Pag = af = EY 458 >t in 8S Feat R=2sn5 = fy. = 2 O38 Pap { = 2¢ G20 = Re 1 = pu S=30 IQuestion 46 Correct Mark 1.00 out of 1.00 Y Flag question A synchronous generator having a reactance of 1 p.u is connected to an infinite bus (V=1z 0°) through a transmission line. The line reactance is 0.5 p.u. Th e machine has an inertia constant of 4 MW - sec/MVA. Under no load conditions, the generated emf is 1.1 p.u. The system frequency is 50 Hz. Then, the frequency of natural oscillations is --- aaa _ if the generator is loaded to 75% of its maximum power limit. a. 1.0535 Hz b. 0.7212 Hz c. 0.1132 Hz d. 1.845 HzRasy @ss ’ Pe © FSP ax > G@ss= o Pe Ix)-1 1-5 oe fh = 0-55 me Flee sv ose = o-45 Puy = fesse pa bly oth = 55 pa alee We 50H 035 oy: hy t walls Q= yOQuestion 48 Correct Mark 1.00 out of 1.00 ¥ Flag question Two generators rated 200 MVA and 150 MVA are having inertia constants 5 and 4 MJ/MVA respectively. Th e two machines are put in parallel and are swinging coherently. Then, the inertia constant of the equivalent machine on a base of 100 MVA, which represents the two machines is a. 5.89 MJ/MVA b. 120 MJ/MVA c. 16 MU/MVAgy d. 38 MJ/MVA Your answer is correct. The correct answer is: 16 MJ/MVAH¥Qvo +x Bo Oona loo = My ]MvAQuestion 50 Correct Mark 1.00 out of 1.00 Y Flag question A 50 Hz, four-pole turboalternator rated at 20 MVA, 13.2 kV has an inertia constant H = 4 kW sec/kVA. The K.E. stored in the rotor at synchronous speed is: a. 40 megajoules b. 20 megajoules c. 80 kilojoules d. 80 megajoulesyy Your answer is correct. The correct answer is: 80 megajoulesoo Do- cE=CH= Ro *4 = 80 My
You might also like
Tutorial 2 Stability
PDF
100% (2)
Tutorial 2 Stability
8 pages
4 Problems
PDF
77% (13)
4 Problems
17 pages
Power System Stability _ Practice Sheet 01(By Ajay Sir)
PDF
No ratings yet
Power System Stability _ Practice Sheet 01(By Ajay Sir)
5 pages
Power System Stability _ Practice Sheet 01 Discussion Notes(By Ajay Sir)
PDF
No ratings yet
Power System Stability _ Practice Sheet 01 Discussion Notes(By Ajay Sir)
38 pages
Power System Stability _ Practice Sheet-01
PDF
No ratings yet
Power System Stability _ Practice Sheet-01
4 pages
EE482 Tutorial 7 Stability PDF
PDF
No ratings yet
EE482 Tutorial 7 Stability PDF
9 pages
Gate Questions Bank EE Power System
PDF
No ratings yet
Gate Questions Bank EE Power System
6 pages
PSA U-4 Q
PDF
No ratings yet
PSA U-4 Q
7 pages
Sheet 1
PDF
0% (1)
Sheet 1
3 pages
Quiz - 1 M.E (Ee) Subject: Psoc: (C) 800MJ (D) 12.5MJ
PDF
No ratings yet
Quiz - 1 M.E (Ee) Subject: Psoc: (C) 800MJ (D) 12.5MJ
2 pages
1730948401
PDF
No ratings yet
1730948401
62 pages
UNIT 5 psa
PDF
No ratings yet
UNIT 5 psa
5 pages
Problem Set 5
PDF
No ratings yet
Problem Set 5
3 pages
Lecture 3_Swing Equestion B
PDF
No ratings yet
Lecture 3_Swing Equestion B
22 pages
Power System Question Series Part - With Anno 1717859165693
PDF
No ratings yet
Power System Question Series Part - With Anno 1717859165693
45 pages
Al-Balqa Applied University: Transient Stability
PDF
No ratings yet
Al-Balqa Applied University: Transient Stability
52 pages
Power Systems (Q Bank Ch4_Stability)
PDF
No ratings yet
Power Systems (Q Bank Ch4_Stability)
22 pages
E-Note_36623_Content_Document_20250518030804PM
PDF
No ratings yet
E-Note_36623_Content_Document_20250518030804PM
44 pages
Assignment 4 Power System Stability
PDF
100% (1)
Assignment 4 Power System Stability
3 pages
SR No. Questions: Darshan Institute of Engineering and Technology Electrical Engineering Department Tutorial - 8
PDF
No ratings yet
SR No. Questions: Darshan Institute of Engineering and Technology Electrical Engineering Department Tutorial - 8
1 page
All Soln
PDF
No ratings yet
All Soln
8 pages
11th & 12th Stability 412
PDF
No ratings yet
11th & 12th Stability 412
26 pages
Assignment PSE
PDF
No ratings yet
Assignment PSE
5 pages
Power System Stability: by A. Prof. Dr. Mohammed Jasim M
PDF
No ratings yet
Power System Stability: by A. Prof. Dr. Mohammed Jasim M
33 pages
ELG3311: Assignment 2: Problem 5-22
PDF
No ratings yet
ELG3311: Assignment 2: Problem 5-22
10 pages
Lecture6 Islamer PS
PDF
No ratings yet
Lecture6 Islamer PS
31 pages
COMPLETION EXAM
PDF
No ratings yet
COMPLETION EXAM
4 pages
EEE 4126F 2023 Tut Instruction Sheet 4
PDF
No ratings yet
EEE 4126F 2023 Tut Instruction Sheet 4
3 pages
4 Problems
PDF
100% (1)
4 Problems
17 pages
EEU801 Power System Stability: "Education For Salvation of Soul''
PDF
No ratings yet
EEU801 Power System Stability: "Education For Salvation of Soul''
10 pages
Cabantugan Ee113 Lab Act 5
PDF
No ratings yet
Cabantugan Ee113 Lab Act 5
20 pages
Synchronous Solution) ) ) ) )
PDF
No ratings yet
Synchronous Solution) ) ) ) )
25 pages
บทที่11
PDF
No ratings yet
บทที่11
10 pages
230 Power System Stability PDF
PDF
100% (1)
230 Power System Stability PDF
31 pages
Lecture 2_Swing Equation A
PDF
No ratings yet
Lecture 2_Swing Equation A
20 pages
Unit-4 Stability
PDF
No ratings yet
Unit-4 Stability
16 pages
Sheet 4 stabilityf
PDF
No ratings yet
Sheet 4 stabilityf
2 pages
Exam 11
PDF
No ratings yet
Exam 11
9 pages
Tsgenco Eee Previous Paper 2015 3112e48d
PDF
No ratings yet
Tsgenco Eee Previous Paper 2015 3112e48d
18 pages
ExerciseSet6 01
PDF
100% (1)
ExerciseSet6 01
3 pages
Power System Stability: Page 1 of 2
PDF
No ratings yet
Power System Stability: Page 1 of 2
2 pages
Machines-1 Final
PDF
No ratings yet
Machines-1 Final
8 pages
Power System Stability Analysis: 500 MVA 11kV/400kV X 100
PDF
No ratings yet
Power System Stability Analysis: 500 MVA 11kV/400kV X 100
8 pages
EEE 315 ELECTRICAL MACHINES III Supplementary EXAM - 2017
PDF
No ratings yet
EEE 315 ELECTRICAL MACHINES III Supplementary EXAM - 2017
5 pages
4thpast Papers Batch 2015 and 2016
PDF
No ratings yet
4thpast Papers Batch 2015 and 2016
27 pages
911uf Ee Abcd Synchronus
PDF
No ratings yet
911uf Ee Abcd Synchronus
14 pages
Sheet 4
PDF
No ratings yet
Sheet 4
2 pages
ELK474E_Solved Problems 3.1X (2)
PDF
No ratings yet
ELK474E_Solved Problems 3.1X (2)
11 pages
5 - Swing equations - syn. coefficient
PDF
No ratings yet
5 - Swing equations - syn. coefficient
38 pages
EPS2 Unit 3 (1) - Merged
PDF
No ratings yet
EPS2 Unit 3 (1) - Merged
38 pages
Assignment-I (Power System Stability and Control EE16103)
PDF
50% (2)
Assignment-I (Power System Stability and Control EE16103)
2 pages
Qestions of Electrical Machines
PDF
No ratings yet
Qestions of Electrical Machines
5 pages
senapati2015
PDF
No ratings yet
senapati2015
5 pages
Doubly-Fed Induction Generator Modeling and Control in Digsilent Powerfactory
PDF
No ratings yet
Doubly-Fed Induction Generator Modeling and Control in Digsilent Powerfactory
7 pages
PSEDppt
PDF
No ratings yet
PSEDppt
30 pages
PSA2 - TestNo. 3
PDF
No ratings yet
PSA2 - TestNo. 3
13 pages
PSP MCQs
PDF
No ratings yet
PSP MCQs
10 pages
PSA1 Final Test - 2022 Solution
PDF
No ratings yet
PSA1 Final Test - 2022 Solution
19 pages
Power System Protection Lec 3
PDF
No ratings yet
Power System Protection Lec 3
16 pages
Active Vs Passive Transformations in Field Theories
PDF
No ratings yet
Active Vs Passive Transformations in Field Theories
6 pages
Stability Analysis of Smart Grid Managem
PDF
No ratings yet
Stability Analysis of Smart Grid Managem
10 pages
Hartani10.1007978 3 030 37207 1
PDF
No ratings yet
Hartani10.1007978 3 030 37207 1
10 pages