Legacy Linear Actuators CTEN
Legacy Linear Actuators CTEN
www.thomsonlinear.com
Electrak 1
12 and 24 Vdc - load up to 75 lbf
Performance Specifications
Parameter Electrak 1
Maximum load, dynamic / static [lbf]
S • • -09A4 25 / 300
S • • -17A8 75 / 300
2 www.thomsonlinear.com
Linear Actuators
Electrak 1
12 and 24 Vdc - load up to 75 lbf
Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load
Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed 25 lbf
F max: percent of maximum rated load 2: speed 75 lbf
1: all models
1: all models using the internal limit switches for end 3: current 25 lbf, 12 Vdc
of stroke 4: current 25 lbf, 24 Vdc
2: all models when end of stroke is controlled externally 5: current 75 lbf, 12 Vdc
6: current 75 lbf, 24 Vdc
www.thomsonlinear.com 3
Electrak 1
12 and 24 Vdc - load up to 75 lbf
Ordering Key
1 2 3
S24 - 09A4 - 06
Wiring Diagram
DPDT Switch
Retract
Off
Extend
(–)
Input
Voltage
(+)
4 www.thomsonlinear.com
Linear Actuators
www.thomsonlinear.com 5
Electrak 1SP
12 and 24 Vdc - load up to 75 lbf
Performance Specifications
Parameter Electrak 1SP
Maximum load, dynamic / static [lbf]
SP • • -09A4 25 / 300
SP • • -17A8 75 / 300
6 www.thomsonlinear.com
Linear Actuators
Electrak 1SP
12 and 24 Vdc - load up to 75 lbf
S: stroke A2: black lead for 12 Vdc units, white lead for 24 Vdc units
A: retracted length A3: yellow lead
A1: cable for potentiometer feedback, length = 25 inch
Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load
Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed 25 lbf
F max: percent of maximum rated load 2: speed 75 lbf
1: all models
1: all models when end of stroke is controlled externally 3: current 25 lbf, 12 Vdc
4: current 25 lbf, 24 Vdc
5: current 75 lbf, 12 Vdc
6: current 75 lbf, 24 Vdc
www.thomsonlinear.com 7
Electrak 1SP
12 and 24 Vdc - load up to 75 lbf
Ordering Key
1 2 3
SP24 - 09A4 - 06
Electrak 1SP
DPDT Switch
Retract
Off
Extend
(–)
Actuator
Input
Voltage Yellow
(+)
Black*
White
Potentiometer
Output Red
8 www.thomsonlinear.com
Linear Actuators
www.thomsonlinear.com 9
Electrak 050
12, 24 and 36 Vdc - load up to 112 lbf
Performance Specifications
Parameter Electrak 050
Maximum load, dynamic / static [lbf]
DE • • • 17W41 112 / 224
DE • • • 17W42 60 / 120
DE • • • 17W44 30 / 60
Electrak 050
12, 24 and 36 Vdc - load up to 112 lbf
Performance Diagrams
050, standard version 050, Q-version
Speed and Current vs. Load Speed and Current vs. Load
V: speed I: current F: load
1: speed 112 lbf
2: speed 60 lbf
3: speed 30 lbf
4: current 12 Vdc, 112 lbf *
5: current 24 Vdc, 112 lbf
6: current 12 Vdc, 60 lbf *
7: current 24 Vdc, 60 lbf
8: current 12 Vdc, 30 lbf *
9: current 24 Vdc, 30 lbf
www.thomsonlinear.com 11
Electrak 050
12, 24 and 36 Vdc - load up to 112 lbf
Ordering Key
1 2 3 4 5 6
DE24 - 17W44 - 06 FN HH N
Electrak 050
DPDT Switch
Retract
Off
Extend
(–)
Actuator
Input
Voltage Red
(+)
Yellow
Red
Optional
Potentiometer White
Output
Blue
12 www.thomsonlinear.com
Linear Actuators
www.thomsonlinear.com 13
Electrak 2
12 Vdc - load up to 250 lbf
Performance Specifications
Parameter Electrak 2
Maximum load, dynamic / static [lbf] 250 / 1000
Speed, at no load / at maximum load [in/sec]
D12-10A5 (high speed) 1.20 / 1.00
D12-20A5 (standard speed) 0.61 / 0.55
Parameter Electrak 2
Screw type acme
Internally restrained no
Manual override no, optional
Dynamic braking no
Holding brake no, self-locking
End of stroke protection overload clutch
Mid stroke protection overload clutch
Motor protection auto reset thermal switch
Motor connection flying leads and connector
Motor connector Packard Electric 56 series 2984883
with terminal 2962987. Mating
connector: 2973781 with terminal
2962573 (p/n 9100-448-001)
Certificates CE optional*
Options • potentiometer*
• manual override*
• limit switches*
* Contact customer support
14 www.thomsonlinear.com
Linear Actuators
Electrak 2
12 Vdc - load up to 250 lbf
S: stroke
A: retracted length
A1: yellow lead
A2: red lead
Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load
Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed high speed model
F max: percent of maximum rated load 1: standard speed model 2: speed standard speed model
1: all models using the clutch at the end of stroke 2: high speed model 3: current high speed model
2: standard speed model, 12 inch stroke 4: current standard speed model
3: standard speed model, 8 inch stroke
4: high speed model, 12 inch stroke
5: high speed model, 8 inch stroke and
standard speed model, 4 inch stroke
6: high speed model, 4 inch stroke
www.thomsonlinear.com 15
Electrak 2
12 Vdc - load up to 250 lbf
Ordering Key
1 2 3 4
D12 - 20A5 - 12 D
Wiring Diagram
DPDT Switch
Retract
Off
Extend
(–)
Actuator
Input
Voltage Yellow
(+)
Red
16 www.thomsonlinear.com
Linear Actuators
www.thomsonlinear.com 17
Electrak 10
12, 24 and 36 Vdc - load up to 1500 lbf
Performance Specifications
Parameter Electrak 10
Maximum load, dynamic / static [lbf]
D • • -05B5 500 / 3000
D • • -10(20)B5 1000 / 3000
Contact customer support 1500 / 3000
18 www.thomsonlinear.com
Linear Actuators
Electrak 10
12, 24 and 36 Vdc - load up to 1500 lbf
S: stroke
A: retracted length
A1: yellow lead
A2: red lead
Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load
Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed 500 lbf
F max: percent of maximum rated load 1: 1000 lbf, standard speed 2: speed 1000 lbf, standard speed
1: all models using the clutch at the end of stroke 2: 500 lbf 3: speed 1000 lbf, high speed
2: 1000 lbf, 12 inch stroke 4: current 500 lbf, 12 Vdc
3: 1000 lbf, 8 inch stroke 5: current 500 lbf, 24 Vdc
4: 500 lbf, 12 inch stroke 6: current 1000 lbf, 12 Vdc, standard speed
5: 1000 lbf, 4 inch stroke 7: current 1000 lbf, 24 Vdc, standard speed
6: 500 lbf, 8 inch stroke 8: current 1000 lbf, 12 Vdc, high speed
7: 500 lbf, 4 inch stroke 9: current 1000 lbf, 24 Vdc, high speed
www.thomsonlinear.com 19
Electrak 10
12, 24 and 36 Vdc - load up to 1500 lbf
Ordering Key
1 2 3
D12 - 20B5 - 04
Wiring Diagram
DPDT Switch
Retract
Off
Extend
(–)
Actuator
Input
Voltage Yellow
(+)
Red
20 www.thomsonlinear.com
Linear Actuators
www.thomsonlinear.com 21
Electrak PPA-AC
115 and 230 Vac - load up to 1500 lbf
Performance Specifications
Parameter PPA-AC
Maximum load, dynamic / static [lbf]
PPA • • -18B65 500 / 3000
PPA • • -58B65 1500 / 3000
22 www.thomsonlinear.com
Linear Actuators
Electrak PPA-AC
115 and 230 Vac - load up to 1500 lbf
Performance Diagrams
Speed and Current vs. Load
www.thomsonlinear.com 23
Electrak PPA-AC
115 and 230 Vac - load up to 1500 lbf
Ordering Key
1 2 3 4 5 6
PPA22 - 18B65 - 18 SB XX C
24 www.thomsonlinear.com
Linear Actuators
Electrak PPA-AC
115 and 230 Vac - load up to 1500 lbf
Wiring Diagram
Without brake or with electrical brake (dotted wiring)
DPDT Switch
Retract
Off Actuator
Extend
Capacitor*
Black
L1
Red
Input
Voltage
Brake**
L2 Fuse****
White
PE
Green
Red
Input
Voltage
Brake
Black
L2 Fuse**** Black
Yellow
PE
Green
www.thomsonlinear.com 25
Electrak 5
115 and 230 Vac - load up to 1500 lbf
Performance Specifications
Parameter Electrak 5
Maximum load, dynamic / static [lbf]
A • • -05B5 500 / 2500
A • • -10B5 1000 / 2500
Contact customer support 1500 / 2500
26 www.thomsonlinear.com
Linear Actuators
Electrak 5
115 and 230 Vac - load up to 1500 lbf
S: stroke
A: retracted length
A1: cable
Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load
Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed 500 lbf
F max: percent of maximum rated load 1: 50 Hz input frequency 2: speed 1000 lbf
1: all models using the clutch at the end of stroke 2: 60 Hz input frequency 3: current 500 lbf, 115 Vac
2: all models using the anti-coast brake at the 4: current 1000 lbf, 115 Vac
end of stroke only 5: current 500 lbf, 230 Vac
6: current 1000 lbf, 230 Vac
www.thomsonlinear.com 27
Electrak 5
115 and 230 Vac - load up to 1500 lbf
Ordering Key
1 2 3 4
A12 - 05B5 - 04 D
1. Model and input voltage 2. Dynamic load capacity 3. Stroke 4. Shipment version1
A12 - = Electrak 5, 1 × 115 Vac 05B5 - = 500 lbf 04 = 4 inch D = distributor version
A22 - = Electrak 5, 1 × 230 Vac 10B5 - = 1000 lbf 08 = 8 inch
12 = 12 inch 1
Leave position blank for OEM
18 = 18 inch version.
24 = 24 inch
Electrak 5
DPDT Switch
Retract
Off Actuator
Capacitor*
Extend
Black
L1
Red
Input
Voltage
Brake**
Orange
L2 Fuse***
White
Ground
Green
* Capacitor required to run the actuator. 115 Vac = 35 µF, p/n 9200-448-002,
230 Vac = 10 µF, p/n 9200-448-003.
** Anti coast brake.
*** Supplied by customer.
28 www.thomsonlinear.com
Linear Actuators
www.thomsonlinear.com 29
Electrak 205
115 and 230 Vac - load up to 1500 lbf
Performance Specifications
Parameter Electrak 205
Maximum load, dynamic [lbf]
ALP • • -05 500
ALP • • -10 1000
Contact customer support 1500
Maximum load, static tension [lbf]
Standard Features and Benefits ALP • • - • • 4000
Maximum load, static compression [lbf]
• Robust, strong and reliable ALP • • - • • (stroke under 24 inch) 4000
• Stainless steel extension tube ALP • • - • • (24 inch stroke) 2500
• Highly efficient ball screw drive system Speed, at no load / at maximum load [in/sec]
• Electrical brake for accurate positioning ALP • • -05 2.05 / 1.75
• Motor with thermal switch ALP • • -10 1.10 / 0.90
30 www.thomsonlinear.com
Linear Actuators
Electrak 205
115 and 230 Vac - load up to 1500 lbf
Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load
Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed 500 lbf
F max: percent of maximum rated load 1: 50 Hz input frequency 2: speed 1000 lbf
1: 1000 lbf, 24 inch stroke 2: 60 Hz input frequency 3: current 500 lbf, 115 Vac
2: 1000 lbf, 18 inch stroke 4: current for 1000 lbf, 115 Vac
3: 1000 lbf, 12 inch stroke 5: current 500 lbf, 230 Vac
4: 1000 lbf, 8 inch stroke 6: current 1000 lbf, 230 Vac
5: 1000 lbf, 4 inch stroke
www.thomsonlinear.com 31
Electrak 205
115 and 230 Vac - load up to 1500 lbf
Ordering Key
1 2 3 4
ALP22 - 10B5 - 04
1. Model and input voltage 2. Dynamic load capacity 3. Stroke 4. Shipment version1
ALP12 - = Electrak 205, 1 × 115 Vac 05B5 - = 500 lbf 04 = 4 inch D = distributor version
ALP22 - = Electrak 205, 1 × 230 Vac 10B5 - = 1000 lbf 08 = 8 inch
12 = 12 inch 1
Leave position blank for OEM
18 = 18 inch version.
24 = 24 inch
Electrak 205
Actuator
DPDT Switch
Retract Potentiometer
Off Output
Extend
L1 Capacitor*
LSR**
Input
Voltage
LSE**
L2
Ground Brake***
* Capacitor required to run the actuator. 115 Vac = 35 µF, p/n 9200-448-002,
230 Vac = 10 µF, p/n 9200-448-003.
** LSR = end of stroke limit switch in retracted position,
LSE = end of stroke limit switch in extended position.
*** Electrical brake.
32 www.thomsonlinear.com
Linear Actuators
www.thomsonlinear.com 33
Electrak Non-driven Actuator PPA-M
Load up to 1500 lbf
Performance Specifications
Parameter PPA-M
Maximum load, dynamic / static [lbf] 1500 / 3000
Maximum speed at max. load [in/sec] 0.33
Maximum input torque [lbf-in] 80
Maximum input speed [rpm] 100
Standard Features and Benefits Standard stroke lengths [in] 4, 8, 12, 18,
24, 36
• Actuator with double input shafts to which a customer
supplied motor or/and an intermediate shaft can be Operating temperature limits [°F] -15 – +150
mounted End play, maximum [in] 0.04
• Can be operated manually Restraining torque [lbf-in] 200
• Robust and versatile
• Withstands very harsh environments
• Highly efficient ball screw drive system
• Holding brake prevents back driving
• Trunnion to clevis mounting
• Maintenance free
General Specifications
Parameter Electrak PPA-M
Screw type ball
Internally restrained no
Manual override no*
Holding brake yes
End of stroke protection no
Mid stroke protection no
Certificates –
Options protective bellows
* Either of the two input shafts can be used for manual operation if both shafts
are not connected to a motor or an intermediate shaft.
34 www.thomsonlinear.com
Linear Actuators
S: stroke
A: retracted length
B: retracted length to trunnions
Synchronous Operation
Two or more PPA-M actuators can easily be mechanically linked for synchronous operation. They can either
be driven directly by motor (1) or by the PPA synchronous operation kit (2). Intermediate shafts, couplings
and motors (white details) are supplied by the customer. For more information about the PPA synchronous
operation kit, see Accessories and Spare Parts on page 46.
www.thomsonlinear.com 35
Electrak Non-driven Actuator PPA-M
Load up to 1500 lbf
Ordering Key
1 2 3 4
36 www.thomsonlinear.com
Linear Actuators
www.thomsonlinear.com 37
Rotary Actuator DGB
12, 24 and 36 Vdc - load torque up to 100 lbf-in
Performance Specifications
Parameter DGB
Maximum load torque [lbf-in] 100
Speed, at no load / at maximum load [rpm]
D • • -21GB 200 / 80
D • • -30GB1 140 / 75
Standard Features and Benefits Available input voltages [Vdc] 12, 24, 36
Weight [lb]
• Rotary actuators for industrial and outdoor use D • • - • • • • - XXCL 7.7
• Easy and fast clevis mounting D • • - • • • • - XXMO 7.7
D • • - • • • • - XXDS 7.7
• Overload clutch
• Thermal protected motor Operating temperature limits [°F] -15 – +150
• Manual override or dual output shafts as option Full load duty cycle @ 77 °F [%] 25
Lead cross section [AWG] 14
Lead length [in] 7.0
Protection class IP56
General Specifications
Parameter DGB
Manual override no
Dynamic braking no
Holding brake yes
Overload protection overload clutch
Motor protection auto reset thermal switch
Motor connection flying leads and connector
Motor connector Packard Electric 56 series 2984883
with terminal 2962987. Mating
connector: 2973781 with terminal
2962573 (p/n 9100-448-001)
Certificates CE optional*
Options • manual override
• dual output shafts
• other speeds*
* Contact customer support
38 www.thomsonlinear.com
Linear Actuators
Performance Diagrams
Speed and Current vs. Load
Contact customer support for data on 24 and 36 Vdc models (D • • -30GB is not available for 36 Vdc).
www.thomsonlinear.com 39
Rotary Actuator DGB
12, 24 and 36 Vdc - load torque up to 100 lbf-in
Ordering Key
1 2 3
Wiring Diagram
DPDT Switch
Retract
Off
Extend
(–)
Actuator
Input
Voltage Yellow
(+)
Red
40 www.thomsonlinear.com
Linear Actuators
www.thomsonlinear.com 41
Actuator Controls
Switches
DPDT Switch
Specifications
Parameter DPDT Switch
Maximum voltage [Vac] 270
Maximum current [A] 15
Part number 830-8004-016
• Robust switch
• Double pole, double throw (DPDT) Actuator Compatibility
• 15 A rating at 270 Vac
• Center “off” Electrak 1, Electrak 1SP, Electrak 050, Electrak 2, Electrak
PPA-DC, Electrak 10, Electrak Pro, Electrak PPA-AC, Electrak
• Two momentary contacts
5, Electrak 205, DGB
• Wiring diagram on label
Wiring Diagram
Dimensions
42 www.thomsonlinear.com
Linear Actuators
Actuator Controls
Switches
Specifications
Parameter DPDT Box
Maximum voltage [Vac] 270
Maximum current [A] 15
Protection class NEMA 1
Part number 6932-101-054
Actuator Compatibility
• Robust rocker switch mounted in an enclosure Electrak 1, Electrak 1SP, Electrak 050, Electrak 2, Electrak
• Double pole, double throw (DPDT) PPA-DC, Electrak 10, Electrak Pro, Electrak PPA-AC, Electrak
• 15 A rating at 270 Vac 5, Electrak 205, TC16, DMD, DMA, LM80-H, LM80-V, DGB
• Center “off”
• Two momentary contacts
• Mounting bracket included Wiring Diagram
• Wiring diagram on label
Dimensions
www.thomsonlinear.com 43
Actuator Controls
Electronic Controls
Control MCS-2041
Specifications
Parameter MCS-2041
Input voltage [Vac] 1 × 115
Input frequency [Hz] 50/60
Output voltage [Vac] 1 × 115
Maximum output current [A] 15
Protection class NEMA 1
Part number 6932-448-010
• Robust and compact metal enclosure with a front panel
extend and retract rocker switch
• Prewired internal capacitor Actuator Compatibility
• Fuse protects actuator in case of stalling caused by
Electrak 5
overload
• “Power On” light illuminates whenever power applied
to the control
Wiring Diagram
• Terminal strip for easy electrical connection
• The switch controls both the actuator motor and its anti
coast brake to provide optimum performance
Input
Voltage
Dimensions
Actuator Motor
Black
Red
Orange
Brake
White
Green
44 www.thomsonlinear.com
Linear Actuators
Actuator Controls
Electronic Controls
Control MCS-2051
Specifications
Parameter MCS-2051
Input voltage [Vac] 1 × 115
Input frequency [Hz] 50/60
Output voltage [Vac] 1 × 115
Maximum actuator output current [A] 8
Analog output signal [mA] 4 - 20
Protection class NEMA1
• Control designed to operate an Electrak 205 actuator Part number 6932-448-015
• Robust metal enclosure with front cover mounted
membrane switches and LED indicator lights for
extend, retract, jog, run and remote control Actuator Compatibility
• Emergency stop/off pushbutton remains in position
Electrak 205
when activated
• LCD display shows the extension tube position
• Internal “Run” mode jumper which causes the actuator
Wiring Diagram
to reverse automatically upon reaching the extend end of
stroke limit switch. Reverse motion continues until
reaching the retract end of stroke limit switch J4, “Run” mode jumper*
• The control provides an analog output signal for an
external customer provided control/meter
• Inputs for external extend and retract switches
• Inputs for two external end of stroke limit switches
Input
• Dynamic braking Voltage
Analog
• Terminal strip for easy electrical connection Output
4 - 20 mA
Extend
Dimensions Retract
* Inserting jumper J4 causes the actuator to reverse automatically upon reaching the extend end of
stroke limit switch. Reverse motion continues until reaching the retract end of stroke limit switch.
www.thomsonlinear.com 45
USA, CANADA and MEXICO ASIA
Thomson Asia Pacific
203A West Rock Road Thomson
Radford, VA 24141, USA E-mail: [email protected]
Phone: +1 540 633 3549
Fax: 1 540 633 0294 China
E-mail: [email protected] Thomson
Literature: literature.thomsonlinear.com Rm 805, Scitech Tower
22 Jianguomen Wai Street
EUROPE Beijing 100004
United Kingdom Phone: +86 400 606 1805
Thomson Fax: +86 10 6515 0263
Office 9, The Barns E-mail: [email protected]
Caddsdown Business Park
Bideford, Devon, EX39 3BT India
Phone: +44 1271 334 500 Thomson
E-mail: [email protected] c/o Portescap India Pvt Ltd
1 E, first floor, Arena House
Germany Road no 12, Marol Industrial Area,
Thomson Andheri (E), Mumbai 400093 India
Nürtinger Straße 70 E-mail: [email protected]
72649 Wolfschlugen
Phone: +49 7022 504 403 Japan
Fax: +49 7022 504 405 Thomson
E-mail: [email protected] Minami-Kaneden 2-12-23, Suita
Osaka 564-0044 Japan
France Phone: +81 6 6386 8001
Thomson Fax: +81 6 6386 5022
Phone: +33 243 50 03 30 E-mail: [email protected]
Fax: +33 243 50 03 39
E-mail: [email protected] South Korea
Thomson
Italy 3033 ASEM Tower (Samsung-dong)
Thomson 517 Yeongdong-daero
Via per Cinisello 95/97 Gangnam-gu, Seoul, South Korea (06164)
20834 Nova Milanese (MB) Phone: + 82 2 6001 3223 & 3244
Phone: +39 0362 366406 E-mail: [email protected]
Fax: +39 0362 276790
E-mail: [email protected] SOUTH AMERICA
Brasil
Spain Thomson
Thomson Av. João Paulo Ablas, 2970
E-mail: [email protected] Jardim da Glória - Cotia SP - CEP: 06711-250
Phone: +55 11 4615 6300
Sweden E-mail: [email protected]
Thomson
Estridsväg 10
29109 Kristianstad
Phone: +46 44 24 67 00
Fax: +46 44 24 40 85
E-mail: [email protected]
www.thomsonlinear.com
Linear_Actuators_CTEN-0005-07 | 20190508TJ
Specifications are subject to change without notice. It is the responsibility of the product user to determine the suitability of
this product for a specific application. All trademarks property of their respective owners. ©2019 Thomson Industries, Inc.