Linear Actuators

www.thomsonlinear.com
Electrak 1
12 and 24 Vdc - load up to 75 lbf

Performance Specifications
Parameter Electrak 1
Maximum load, dynamic / static [lbf]
S • • -09A4 25 / 300
S • • -17A8 75 / 300

Speed, at no load / at maximum load [in/sec]


S • • -09A4 3.00 / 2.10
Standard Features and Benefits S • • -17A8 1.00 / 0.65
Available input voltages [Vdc] 12, 24
• Very compact and lightweight
• Integrated end of stroke limit switches Standard stroke lengths [in] 2, 4, 6

• Corrosion resistant housing Operating temperature limits [°F] -15 – +150


• Self-locking acme screw drive system Full load duty cycle @ 77 °F [%] 25
• Maintenance free End play, maximum [in] 0.036
• Ideal for replacement of comparable size pneumatic
Restraining torque [lbf-in] 20
and hydraulic cylinders
Lead cross section [AWG] 18
Lead length [in] 4.5
Protection class IP66
General Specifications
Parameter Electrak 1
Screw type acme
Internally restrained no
Manual override no
Dynamic braking no
Holding brake no, self-locking
End of stroke protection end of stroke limit switches
Mid stroke protection no
Motor protection auto reset thermal switch
Motor connection flying leads and connector
Motor connector Packard Electric Pack-Con male
8911773 with terminal 6294511.
Mating connector: 8911772 with
terminal 8911639 (p/n 9300-448-001)
Certificates CE optional*
Options none
* Contact customer support

2 www.thomsonlinear.com
Linear Actuators

Electrak 1
12 and 24 Vdc - load up to 75 lbf

S: stroke A2: red lead


A: retracted length A3: yellow lead
A1: installation must include at least this much coast beyond limit switch shut off

Ordering stroke [inch] 2 4 6


Actual stroke (S) [inch] 1.8 3.8 5.8
Retracted length (A) [inch] 6.3 8.3 10.3
Weight [lb] 1.2 1.4 1.5

Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load

Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed 25 lbf
F max: percent of maximum rated load 2: speed 75 lbf
1: all models
1: all models using the internal limit switches for end 3: current 25 lbf, 12 Vdc
of stroke 4: current 25 lbf, 24 Vdc
2: all models when end of stroke is controlled externally 5: current 75 lbf, 12 Vdc
6: current 75 lbf, 24 Vdc

www.thomsonlinear.com 3
Electrak 1
12 and 24 Vdc - load up to 75 lbf

Ordering Key
1 2 3

S24 - 09A4 - 06

1. Model and input voltage 2. Dynamic load capacity 3. Stroke


S12 - = Electrak 1, 12 Vdc 09A4 - = 25 lbf 02 = 2 inch
S24 - = Electrak 1, 24 Vdc 17A8 - = 75 lbf 04 = 4 inch
06 = 6 inch

Wiring Diagram
DPDT Switch
Retract
Off
Extend

(–)

Input
Voltage

(+)

Connect the red lead to positive and yellow to negative to


extend the actuator/rotate the output shaft in clockwise
direction. Change polarity to retract the actuator/rotate
the output shaft counterclockwise. Electrak 1 actuators
should be protected from overload conditions by a
customer provided fuse in the circuit (6 A for 12 Vdc and
3 A for 24 Vdc).

4 www.thomsonlinear.com
Linear Actuators

www.thomsonlinear.com 5
Electrak 1SP
12 and 24 Vdc - load up to 75 lbf

Performance Specifications
Parameter Electrak 1SP
Maximum load, dynamic / static [lbf]
SP • • -09A4 25 / 300
SP • • -17A8 75 / 300

Speed, at no load / at maximum load [in/sec]


SP • • -09A4 3.00 / 2.10
Standard Features and Benefits SP • • -17A8 1.00 / 0.65
Available input voltages [Vdc] 12, 24
• Very compact and lightweight
• Potentiometer feedback Standard stroke lengths [in] 2, 4, 6

• Corrosion resistant housing Operating temperature limits [°F] -15 – +150


• Self-locking acme screw drive system Full load duty cycle @ 77 °F [%] 25
• Maintenance free End play, maximum [in] 0.036
• Internally restrained extension tube
Restraining torque [lbf-in] 0
• Ideal for replacement of comparable size pneumatic
and hydraulic cylinders Lead cross section [AWG] 18
Lead length [in] 4.5
Protection class IP66
Potentiometer [kOhm] 10**
General Specifications
Parameter Electrak 1SP
Screw type acme
Internally restrained yes
Manual override no
Dynamic braking no
Holding brake no, self-locking
End of stroke protection no
Mid stroke protection no
Motor protection auto reset thermal switch
Motor connection flying leads and connector
Motor connector Packard Electric Pack-Con male
8911773 with terminal 6294511.
Mating connector: 8911772 with
terminal 8911639 (p/n 9300-448-001)
Certificates CE optional*
Options none
* Contact customer support

6 www.thomsonlinear.com
Linear Actuators

Electrak 1SP
12 and 24 Vdc - load up to 75 lbf

S: stroke A2: black lead for 12 Vdc units, white lead for 24 Vdc units
A: retracted length A3: yellow lead
A1: cable for potentiometer feedback, length = 25 inch

Ordering stroke [inch] 2 4 6


Actual stroke (S) [inch] 2.3 4.5 6.8
Retracted length (A) [inch] 7.8 10.0 12.2
Weight [lb] 1.2 1.4 1.5
Potentiometer resistance change [ohm/in] 2400 1200 800

Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load

Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed 25 lbf
F max: percent of maximum rated load 2: speed 75 lbf
1: all models
1: all models when end of stroke is controlled externally 3: current 25 lbf, 12 Vdc
4: current 25 lbf, 24 Vdc
5: current 75 lbf, 12 Vdc
6: current 75 lbf, 24 Vdc

www.thomsonlinear.com 7
Electrak 1SP
12 and 24 Vdc - load up to 75 lbf

Ordering Key
1 2 3

SP24 - 09A4 - 06

1. Model and input voltage 2. Dynamic load capacity 3. Stroke


SP12 - = Electrak 1SP, 12 Vdc 09A4 - = 25 lbf 02 = 2 inch
SP24 - = Electrak 1SP, 24 Vdc 17A8 - = 75 lbf 04 = 4 inch
06 = 6 inch

Electrak 1SP
DPDT Switch
Retract
Off
Extend

(–)

Actuator
Input
Voltage Yellow

(+)

Black*

White
Potentiometer
Output Red

* Black for 12 Vdc supply voltage Black


White for 24 Vdc supply voltage

Connect the black or white* lead to positive and yellow


to negative to extend the actuator. Change polarity
to retract the actuator. The potentiometer output has
0 ohm between white and red when the actuator is
fully retracted. The actuator should be protected from
overload conditions by a customer provided fuse in the
circuit (6 A for 12 Vdc and 3 A for 24 Vdc).

8 www.thomsonlinear.com
Linear Actuators

www.thomsonlinear.com 9
Electrak 050
12, 24 and 36 Vdc - load up to 112 lbf

Performance Specifications
Parameter Electrak 050
Maximum load, dynamic / static [lbf]
DE • • • 17W41 112 / 224
DE • • • 17W42 60 / 120
DE • • • 17W44 30 / 60

Speed, at no load / at maximum load [in/sec]


Standard Features and Benefits DE • • - 17W41 0.48 / 0.37
DE • • - 17W42 0.95 / 0.72
• Designed for office or medical applications DE • • - 17W44 1.90 / 1.45
DE24Q17W41 0.36 / 0.30
• Small, quiet and lightweight DE24Q17W42 0.70 / 0.55
• Very short retracted length DE24Q17W44 1.50 / 1.20
• Low cost Available input voltages [Vdc] 12, 24, 36
• Durable and corrosion free plastic housing
Standard stroke lengths [in] 2, 4, 6, 8
• Color molded into the plastic, no painting required
• End of stroke limit switches with dynamic braking Operating temperature limits [°F] -30 – +180
• Maintenance free Full load duty cycle @ 70 °F [%] 25
• Internally restrained extension tube End play, maximum [in] 0.06
• Estimated life is minimum 40000 cycles
Restraining torque [lbf-in] 0
• Q-version for noise sensitive applications (24 Vdc only)
Lead cross section [AWG] 18
Lead length [in] 6
General Specifications
Protection class
Parameter Electrak 050 standard version IP66
Q-version IP51
Screw type worm
Potentiometer resistance change [ohm/in]
Internally restrained yes
DE • • • 17W41 560
Manual override no DE • • • 17W42 556
DE • • • 17W44 540
Dynamic braking yes, at end of stroke
Holding brake no, self-locking
End of stroke protection internal limit switches
Mid stroke protection overload clutch
Motor protection auto reset thermal switch
Motor connection flying leads and connector
Motor connector Packard Electric Pack-Con male
8911773 with terminal 6294511
Mating connector: 8911772 with
terminal 12040508
CE optional* Non pot versions are
Certificates
RoHS compliant
Options • potentiometer 10 kOhm**
• cross holes rotated 90°
• white housing
* Contact customer support
** See performance specification table for resistance change per inch of travel.
10 www.thomsonlinear.com
Linear Actuators

Electrak 050
12, 24 and 36 Vdc - load up to 112 lbf

S: stroke A2: red lead


A: retracted length A3: yellow lead
A1: Ø 0.254 ± 0.003 mounting cross holes (2 ×) in standard position A4: vent tube Ø 0.125 inch

Stroke (S) [inch] 2 4 6 8


Retracted length (A) [inch] 5.5 7.5 9.5 11.5
Retracted length, with potentiometer (A) [inch] 6.75 8.75 10.75 –
Weight [lb] 1.4 1.6 1.8 2.0
Weight with potentiometer [lb] 1.6 1.8 2.0 –

Performance Diagrams
050, standard version 050, Q-version
Speed and Current vs. Load Speed and Current vs. Load
V: speed I: current F: load
1: speed 112 lbf
2: speed 60 lbf
3: speed 30 lbf
4: current 12 Vdc, 112 lbf *
5: current 24 Vdc, 112 lbf
6: current 12 Vdc, 60 lbf *
7: current 24 Vdc, 60 lbf
8: current 12 Vdc, 30 lbf *
9: current 24 Vdc, 30 lbf

* 12 Vdc not possible for Q-version.

www.thomsonlinear.com 11
Electrak 050
12, 24 and 36 Vdc - load up to 112 lbf

Ordering Key
1 2 3 4 5 6

DE24 - 17W44 - 06 FN HH N

1. Model and input voltage 3. Stroke 5. Rear and front mounting


DE12 - = Electrak 050, 12 Vdc 02 = 2 inch HH = standard crosshole in both ends
DE24 - = Electrak 050, 24 Vdc 04 = 4 inch MH = crossholes rotated 90°
DE36 - = Electrak 050, 36 Vdc 06 = 6 inch
DE24Q = Electrak 050, 24 Vdc, Q-version 08 = 8 inch 6. Color
N = black housing
2. Dynamic load capacity 4. End of stroke limit switches and potentiometer W = white housing
17W41 - = 112 lbf FN = limit switches and no potentiometer
17W42 - = 60 lbf FP = limit switches and potentiometer1 1
Not possible in combination with 8 inch stroke.
17W44 - = 30 lbf

Electrak 050
DPDT Switch
Retract
Off
Extend

(–)

Actuator
Input
Voltage Red

(+)

Yellow

Red
Optional
Potentiometer White
Output
Blue

Connect the yellow lead to positive and red to negative to


extend the actuator. Change polarity to retract the
actuator. The potentiometer output has 0 ohm between
white and red when the actuator is fully retracted.

12 www.thomsonlinear.com
Linear Actuators

www.thomsonlinear.com 13
Electrak 2
12 Vdc - load up to 250 lbf

Performance Specifications
Parameter Electrak 2
Maximum load, dynamic / static [lbf] 250 / 1000
Speed, at no load / at maximum load [in/sec]
D12-10A5 (high speed) 1.20 / 1.00
D12-20A5 (standard speed) 0.61 / 0.55

Standard Features and Benefits Available input voltages [Vdc] 12


Standard stroke lengths [in] 4, 8, 12,
• Economical and robust actuator for medium loads 18*, 24*
• Stainless steel extension tube Operating temperature limits [°F] -15 – +150
• Self-locking acme screw drive system Full load duty cycle @ 77 °F [%] 25
• Overload clutch for mid and end of stroke protection End play, maximum [in] 0.08
• Motor with thermal switch
Restraining torque [lbf-in] 65
• Maintenance free
Lead cross section [AWG] 14
Lead length [in] 7.5
Protection class IP66
General Specifications * Contact customer support

Parameter Electrak 2
Screw type acme
Internally restrained no
Manual override no, optional
Dynamic braking no
Holding brake no, self-locking
End of stroke protection overload clutch
Mid stroke protection overload clutch
Motor protection auto reset thermal switch
Motor connection flying leads and connector
Motor connector Packard Electric 56 series 2984883
with terminal 2962987. Mating
connector: 2973781 with terminal
2962573 (p/n 9100-448-001)
Certificates CE optional*
Options • potentiometer*
• manual override*
• limit switches*
* Contact customer support

14 www.thomsonlinear.com
Linear Actuators

Electrak 2
12 Vdc - load up to 250 lbf

S: stroke
A: retracted length
A1: yellow lead
A2: red lead

Stroke (S) [inch] 4 8 12


Retracted length (A) [inch] 10.3 14.3 18.3
Weight [lb] 10.0 10.7 11.4

Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load

Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed high speed model
F max: percent of maximum rated load 1: standard speed model 2: speed standard speed model
1: all models using the clutch at the end of stroke 2: high speed model 3: current high speed model
2: standard speed model, 12 inch stroke 4: current standard speed model
3: standard speed model, 8 inch stroke
4: high speed model, 12 inch stroke
5: high speed model, 8 inch stroke and
standard speed model, 4 inch stroke
6: high speed model, 4 inch stroke

www.thomsonlinear.com 15
Electrak 2
12 Vdc - load up to 250 lbf

Ordering Key
1 2 3 4

D12 - 20A5 - 12 D

1. Input voltage 3. Stroke1 4. Shipment version2


D12 - = 12 Vdc 04 = 4 inch D = distributor version
08 = 8 inch
2. Dynamic load capacity and speed 12 = 12 inch 1
Contact customer service for other stroke
10A5 - = 250 lbf, high speed lengths.
20A5 - = 250 lbf, standard speed
Contact customer support for OEM version.
2

Wiring Diagram
DPDT Switch
Retract
Off
Extend

(–)

Actuator
Input
Voltage Yellow

(+)

Red

Connect the red lead to positive and yellow to negative to


extend the actuator/rotate the output shaft in clockwise
direction. Change polarity to retract the actuator/rotate
the output shaft counterclockwise.

16 www.thomsonlinear.com
Linear Actuators

www.thomsonlinear.com 17
Electrak 10
12, 24 and 36 Vdc - load up to 1500 lbf

Performance Specifications
Parameter Electrak 10
Maximum load, dynamic / static [lbf]
D • • -05B5 500 / 3000
D • • -10(20)B5 1000 / 3000
Contact customer support 1500 / 3000

Speed, at no load / at maximum load [in/sec]


Standard Features and Benefits D • • -05B5 2.40 / 1.40
D • • -10B5 (high speed) 1.30 / 0.80
• Robust, strong and reliable D • • -20B5 (standard speed) 0.60 / 0.45
• Withstands very harsh environments Available input voltages [Vdc] 12, 24, 36
• Stainless steel extension tube Standard stroke lengths [in] 4, 8, 12,
• Highly efficient ball screw drive system 18*, 24*
• Overload clutch for mid and end of stroke protection Operating temperature limits [°F] -15 – +150
• Motor with thermal switch
Full load duty cycle @ 77 °F [%] 25
• Maintenance free
End play, maximum [in] 0.04
Restraining torque [lbf-in] 100

General Specifications Lead cross section [AWG] 14


Lead length [in] 7.5
Parameter Electrak 10
Protection class IP66
Screw type ball
* Contact customer support
Internally restrained no
Manual override no, optional
Dynamic braking no
Holding brake yes
End of stroke protection overload clutch
Mid stroke protection overload clutch
Motor protection auto reset thermal switch
Motor connection flying leads and connector
Motor connector Packard Electric 56 series 2984883
with terminal 2962987. Mating
connector: 2973781 with terminal
2962573 (p/n 9100-448-001)
Certificates CE optional*
Options • potentiometer*
• manual override*
• limit switches*
* Contact customer support

18 www.thomsonlinear.com
Linear Actuators

Electrak 10
12, 24 and 36 Vdc - load up to 1500 lbf

S: stroke
A: retracted length
A1: yellow lead
A2: red lead

Stroke (S) [inch] 4 8 12


Retracted length (A) [inch] 11.9 15.9 19.9
Weight [lb] 11.3 12.0 12.7

Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load

Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed 500 lbf
F max: percent of maximum rated load 1: 1000 lbf, standard speed 2: speed 1000 lbf, standard speed
1: all models using the clutch at the end of stroke 2: 500 lbf 3: speed 1000 lbf, high speed
2: 1000 lbf, 12 inch stroke 4: current 500 lbf, 12 Vdc
3: 1000 lbf, 8 inch stroke 5: current 500 lbf, 24 Vdc
4: 500 lbf, 12 inch stroke 6: current 1000 lbf, 12 Vdc, standard speed
5: 1000 lbf, 4 inch stroke 7: current 1000 lbf, 24 Vdc, standard speed
6: 500 lbf, 8 inch stroke 8: current 1000 lbf, 12 Vdc, high speed
7: 500 lbf, 4 inch stroke 9: current 1000 lbf, 24 Vdc, high speed

www.thomsonlinear.com 19
Electrak 10
12, 24 and 36 Vdc - load up to 1500 lbf

Ordering Key
1 2 3

D12 - 20B5 - 04

1. Input voltage 2. Dynamic load capacity and speed 3. Stroke


D12 - = 12 Vdc 05B5 - = 500 lbf 04 = 4 inch
D24 - = 24 Vdc 10B5 - = 1000 lbf, high speed 08 = 8 inch
D36 - = 36 Vdc 20B5 - = 1000 lbf, standard speed 12 = 12 inch

Wiring Diagram
DPDT Switch
Retract
Off
Extend

(–)

Actuator
Input
Voltage Yellow

(+)

Red

Connect the red lead to positive and yellow to negative to


extend the actuator/rotate the output shaft in clockwise
direction. Change polarity to retract the actuator/rotate
the output shaft counterclockwise.

20 www.thomsonlinear.com
Linear Actuators

www.thomsonlinear.com 21
Electrak PPA-AC
115 and 230 Vac - load up to 1500 lbf

Performance Specifications
Parameter PPA-AC
Maximum load, dynamic / static [lbf]
PPA • • -18B65 500 / 3000
PPA • • -58B65 1500 / 3000

Speed, at no load / at maximum load [in/sec]


PPA11-18B65 0.63 / 0.60
Standard Features and Benefits PPA22-18B65 0.55 / 0.50
PPA • • -58B65 0.17 / 0.17
• Strong and versatile heavy duty actuator Available input voltages [Vac]
• High duty cycle Single phase 115, 230
• Highly efficient ball screw drive system
Input frequency [Hz]
• Overload clutch for mid and end of stroke protection 1 × 115 Vac model 50/60
• Stroke lengths up to 36 inch 1 × 230 Vac model 50/60
• Motor with thermal switch Standard stroke lengths [in] 4, 8, 12,
• Maintenance free 18, 24, 36
• Large range of options Operating temperature limits [°F] -15 – +150
Full load duty cycle @ 77 °F [%] 30
End play, maximum [in] 0.040

General Specifications Restraining torque [lbf-in]


PPA • • -18B65 100
Parameter Electrak PPA-AC PPA • • -58B65 200

Screw type ball Lead cross section [AWG] 18


Internally restrained no Lead length [in] 19.5
Manual override no, optional Protection class IP22
Dynamic braking no
Holding brake yes
End of stroke protection overload clutch
Mid stroke protection overload clutch
Motor protection auto reset thermal switch
Motor connection flying leads
Motor connector no
Certificates RoHS compliant
Options • end of stroke limit switches
• potentiometer
• encoder
• protective bellows
• anti-coast brake *
• electrical brake **
• manual override***
* External capacitor, which is supplied with the actuator, is required to run
actuators with anti-coast brake option. See page 47 for capacitor dimensions.
** Only possible on 115 Vac models *** Contact customer support

22 www.thomsonlinear.com
Linear Actuators

Electrak PPA-AC
115 and 230 Vac - load up to 1500 lbf

S: stroke C: motor length


A: retracted length A1: housing dimensions for limit switch, encoder or potentiometer options
B: retracted length to trunnions

Stroke (S) [inch] 4 8 12 18 24 36


Retracted length (A) without options [inch] 13.7 17.7 21.7 29.7 35.7 47.7
Retracted length (A) with limit switch, [inch]
15.7 19.7 23.7 31.7 37.7 49.7
encoder or potentiometer
Retracted length (B) [inch] 8.8 12.8 16.8 24.8 30.8 42.8
Motor length (C) without brake [inch] 9.5 9.5 9.5 9.5 9.5 9.5
Motor length (C) with anti-coast brake [inch] 7.5 7.5 7.5 7.5 7.5 7.5
Motor length (C) with electrical brake [inch] 11.0 11.0 11.0 11.0 11.0 11.0
Weight [lb] 13.2 14.8 16.5 19.1 21.6 27.0
Weight with electrical brake [lb] 14.6 16.2 17.9 20.5 23.0 28.4
Add on weight for limit switch, [lb]
1.7 1.7 1.7 1.7 1.7 1.7
encoder or potentiometer

Performance Diagrams
Speed and Current vs. Load

V: speed I: current F: load


1: speed 500 lbf, 115 Vac
2: speed 500 lbf, 230 Vac
3: speed 1500 lbf
4: current 500 lbf, 115 Vac
5: current 500 lbf, 230 Vac
6: current 1500 lbf, 115 Vac
7: current 1500 lbf, 230 Vac

www.thomsonlinear.com 23
Electrak PPA-AC
115 and 230 Vac - load up to 1500 lbf

Ordering Key
1 2 3 4 5 6

PPA22 - 18B65 - 18 SB XX C

1. Model and input voltage 3. Stroke 5. Feedback option


PPA11 - = Electrak PPA-AC, 1 × 115 Vac 04 = 4 inch XX = no feedback option
PPA22 - = Electrak PPA-AC, 1 × 230 Vac 08 = 8 inch LS = end of stroke limit switches
12 = 12 inch PO = potentiometer3
2. Dynamic load capacity 18 = 18 inch HS = encoder
18B65 - = 500 lbf 24 = 24 inch HL = encoder + end of stroke limit switches
58B65 - = 1500 lbf 36 = 36 inch
6. Bellows option
4. Brake option1 X = no bellows
N - = no brake option C = bellows4
SB = anti coast brake
EB = electrical brake2 1
See “Brake” in the Glossary section on page 57
for more information.
2
Only possible for 1 × 115 Vac models.
3
Not available with limit switches.
4
Only possible on 12 inch stroke or longer.

24 www.thomsonlinear.com
Linear Actuators

Electrak PPA-AC
115 and 230 Vac - load up to 1500 lbf

Wiring Diagram
Without brake or with electrical brake (dotted wiring)

DPDT Switch
Retract
Off Actuator
Extend
Capacitor*
Black
L1

Red
Input
Voltage

Brake**
L2 Fuse****
White
PE
Green

With anti coast brake


DPDT Switch
Retract
Off Actuator
Extend
Blue
L1
Capacitor***

Red
Input
Voltage
Brake
Black

L2 Fuse**** Black

Yellow
PE
Green

* The actuator comes with prewired capacitor from factory.


** Electrical brake only possible on 115 Vac models.
*** The capacitor is supplied with the actuator but needs to be fitted by the customer externally.
**** Supplied by customer.

For versions without brake or with electrical brake,


connect the red lead to L1 and yellow to L2 to extend the
actuator. Change L1 from red to black lead to retract the
actuator. If the actuator is equipped with an electrical
brake the internal wiring automatically lifts the brake
when the motor is energized. For versions with anti
coast brake, connect the red lead to L1 and yellow to L2
to extend the actuator. Change L1 from red to blue lead
to retract the actuator. Release the anti-coast brake by
connecting black leads to L1 and L2.

www.thomsonlinear.com 25
Electrak 5
115 and 230 Vac - load up to 1500 lbf

Performance Specifications
Parameter Electrak 5
Maximum load, dynamic / static [lbf]
A • • -05B5 500 / 2500
A • • -10B5 1000 / 2500
Contact customer support 1500 / 2500

Speed, at no load / at maximum load [in/sec]


Standard Features and Benefits A • • -05B5 2.10 / 1.70
A • • -10B5 1.10 / 1.00
• Robust, strong and reliable Available input voltages** [Vac]
• Stainless steel extension tube Single phase 115, 230
• Highly efficient ball screw drive system
Input frequency [Hz]
• Overload clutch for mid and end of stroke protection 1 × 120 Vac model 60
• Heavy duty motor with thermal switch 1 × 230 Vac model 50/60
• Anti-coast brake for repeatable positioning Standard stroke lengths [in] 4, 8, 12,
• Maintenance free 18, 24
Operating temperature limits [°F] -15 – +150
Full load duty cycle @ 77 °F [%] 25
Maximum on time [sec] 45
General Specifications
End play, maximum [in] 0.04
Parameter Electrak 5
Restraining torque [lbf-in] 100
Screw type ball
Lead cross section [AWG] 18
Internally restrained no
Cable length [in] 23
Manual override no, optional
Protection class IP55
Dynamic braking no ** Capacitor required to run the actuator. 115 Vac = 35 µF, p/n 9200-448-002,
230 Vac = 10 µF, p/n 9200-448-003.
Holding brake yes
End of stroke protection overload clutch
Mid stroke protection overload clutch
Motor protection auto reset thermal switch
Motor connection flying leads
Certificates UL, CSA, CE optional*
Options • potentiometer*
• manual override*
• limit switches*
* Contact customer support

26 www.thomsonlinear.com
Linear Actuators

Electrak 5
115 and 230 Vac - load up to 1500 lbf

S: stroke
A: retracted length
A1: cable

Stroke (S) [inch] 4 8 12 18 24


Retracted length (A) [inch] 15.0 19.0 23.0 29.0 35.0
Weight [lb] 14.4 15.2 16.1 17.3 18.6

Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load

Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed 500 lbf
F max: percent of maximum rated load 1: 50 Hz input frequency 2: speed 1000 lbf
1: all models using the clutch at the end of stroke 2: 60 Hz input frequency 3: current 500 lbf, 115 Vac
2: all models using the anti-coast brake at the 4: current 1000 lbf, 115 Vac
end of stroke only 5: current 500 lbf, 230 Vac
6: current 1000 lbf, 230 Vac

www.thomsonlinear.com 27
Electrak 5
115 and 230 Vac - load up to 1500 lbf

Ordering Key
1 2 3 4

A12 - 05B5 - 04 D

1. Model and input voltage 2. Dynamic load capacity 3. Stroke 4. Shipment version1
A12 - = Electrak 5, 1 × 115 Vac 05B5 - = 500 lbf 04 = 4 inch D = distributor version
A22 - = Electrak 5, 1 × 230 Vac 10B5 - = 1000 lbf 08 = 8 inch
12 = 12 inch 1
Leave position blank for OEM
18 = 18 inch version.
24 = 24 inch

Electrak 5
DPDT Switch
Retract
Off Actuator
Capacitor*
Extend
Black
L1

Red
Input
Voltage
Brake**
Orange

L2 Fuse***
White

Ground
Green

* Capacitor required to run the actuator. 115 Vac = 35 µF, p/n 9200-448-002,
230 Vac = 10 µF, p/n 9200-448-003.
** Anti coast brake.
*** Supplied by customer.

Connect the red lead to L1 and white to L2 to extend the


actuator. Change L1 from red to black lead to retract the
actuator. Release the anti coast brake by connecting
orange lead to L1.

28 www.thomsonlinear.com
Linear Actuators

www.thomsonlinear.com 29
Electrak 205
115 and 230 Vac - load up to 1500 lbf

Performance Specifications
Parameter Electrak 205
Maximum load, dynamic [lbf]
ALP • • -05 500
ALP • • -10 1000
Contact customer support 1500
Maximum load, static tension [lbf]
Standard Features and Benefits ALP • • - • • 4000
Maximum load, static compression [lbf]
• Robust, strong and reliable ALP • • - • • (stroke under 24 inch) 4000
• Stainless steel extension tube ALP • • - • • (24 inch stroke) 2500
• Highly efficient ball screw drive system Speed, at no load / at maximum load [in/sec]
• Electrical brake for accurate positioning ALP • • -05 2.05 / 1.75
• Motor with thermal switch ALP • • -10 1.10 / 0.90

• Adjustable end of stroke limit switches Available input voltages* [Vac]


• Potentiometer Single phase 115, 230
• Universal mounting clamp for tube mounting available Input frequency [Hz]
• Maintenance free 1 × 120 Vac model 60
1 × 230 Vac model 50/60
Standard stroke lengths [in] 4, 8, 12,
18, 24
Operating temperature limits [°F] -15 – +150
General Specifications Full load duty cycle @ 77 °F [%] 25
Parameter Electrak 205 End play, maximum [in] 0.035
Screw type ball Restraining torque [lbf-in] 100
Internally restrained no Max. terminal strip lead cross section [AWG] 14
Manual override no Protection class IP55
Dynamic braking no Potentiometer [kOhm] 10
Holding brake yes Potentiometer resistance change [ohm/in] 385
End of stroke protection adjustable limit switches * Capacitor required to run the actuator. 115 Vac = 35 µF, p/n 9200-448-002,
230 Vac = 10 µF, p/n 9200-448-003.
Mid stroke protection no Universal mounting kit. 9200-448-006

Motor protection auto reset thermal switch


Motor connection terminal strip in the housing
Cable entrance 1/2” NPT
Certificates none
Options none

30 www.thomsonlinear.com
Linear Actuators

Electrak 205
115 and 230 Vac - load up to 1500 lbf

S: stroke A2: grease fitting


A: retracted length A3: limit switch adjustment
A1: universal mounting clamp

Stroke (S) [inch] 4 8 12 18 24


Retracted length (A) [inch] 22.2 26.2 30.2 36.2 42.2
Weight [lb] 25.5 27.5 29.5 32.5 35.5

Performance Diagrams
Life vs. Load Duty Cycle vs. Load Speed and Current vs. Load

Ncycle: life in number of cycles ED: duty cycle in percent at 77° F V: speed I: current F: load
(one cycle = extend and retract) F max: percent of maximum rated load 1: speed 500 lbf
F max: percent of maximum rated load 1: 50 Hz input frequency 2: speed 1000 lbf
1: 1000 lbf, 24 inch stroke 2: 60 Hz input frequency 3: current 500 lbf, 115 Vac
2: 1000 lbf, 18 inch stroke 4: current for 1000 lbf, 115 Vac
3: 1000 lbf, 12 inch stroke 5: current 500 lbf, 230 Vac
4: 1000 lbf, 8 inch stroke 6: current 1000 lbf, 230 Vac
5: 1000 lbf, 4 inch stroke

www.thomsonlinear.com 31
Electrak 205
115 and 230 Vac - load up to 1500 lbf

Ordering Key
1 2 3 4

ALP22 - 10B5 - 04

1. Model and input voltage 2. Dynamic load capacity 3. Stroke 4. Shipment version1
ALP12 - = Electrak 205, 1 × 115 Vac 05B5 - = 500 lbf 04 = 4 inch D = distributor version
ALP22 - = Electrak 205, 1 × 230 Vac 10B5 - = 1000 lbf 08 = 8 inch
12 = 12 inch 1
Leave position blank for OEM
18 = 18 inch version.
24 = 24 inch

Electrak 205
Actuator

DPDT Switch
Retract Potentiometer
Off Output
Extend

L1 Capacitor*

LSR**

Input
Voltage
LSE**

L2

Ground Brake***

* Capacitor required to run the actuator. 115 Vac = 35 µF, p/n 9200-448-002,
230 Vac = 10 µF, p/n 9200-448-003.
** LSR = end of stroke limit switch in retracted position,
LSE = end of stroke limit switch in extended position.
*** Electrical brake.

The terminal strip is accessed by opening the rear


cover of the actuator housing. Connect terminal 8 to L1
and terminal 2 to L2 to extend the actuator. Change L1
from terminal 8 to 13 to retract the actuator. Release
the anti coast brake by connecting terminal 1 to L1. The
potentiometer output is connected to terminals 14, 15 and
16.

32 www.thomsonlinear.com
Linear Actuators

www.thomsonlinear.com 33
Electrak Non-driven Actuator PPA-M
Load up to 1500 lbf

Performance Specifications
Parameter PPA-M
Maximum load, dynamic / static [lbf] 1500 / 3000
Maximum speed at max. load [in/sec] 0.33
Maximum input torque [lbf-in] 80
Maximum input speed [rpm] 100
Standard Features and Benefits Standard stroke lengths [in] 4, 8, 12, 18,
24, 36
• Actuator with double input shafts to which a customer
supplied motor or/and an intermediate shaft can be Operating temperature limits [°F] -15 – +150
mounted End play, maximum [in] 0.04
• Can be operated manually Restraining torque [lbf-in] 200
• Robust and versatile
• Withstands very harsh environments
• Highly efficient ball screw drive system
• Holding brake prevents back driving
• Trunnion to clevis mounting
• Maintenance free

General Specifications
Parameter Electrak PPA-M
Screw type ball
Internally restrained no
Manual override no*
Holding brake yes
End of stroke protection no
Mid stroke protection no
Certificates –
Options protective bellows
* Either of the two input shafts can be used for manual operation if both shafts
are not connected to a motor or an intermediate shaft.

34 www.thomsonlinear.com
Linear Actuators

Electrak Non-driven Actuator PPA-M


Load up to 1500 lbf

S: stroke
A: retracted length
B: retracted length to trunnions

Stroke (S) [inch] 4 8 12 18 24 36


Retracted length (A) [inch] 14.8 18.8 22.8 30.8 36.8 48.8
Retracted length to trunnions (B) [inch] 8.8 12.8 16.8 24.8 30.8 42.8
Weight [lb] 7.6 9.2 10.6 13.5 16.0 21.4

Synchronous Operation

Two or more PPA-M actuators can easily be mechanically linked for synchronous operation. They can either
be driven directly by motor (1) or by the PPA synchronous operation kit (2). Intermediate shafts, couplings
and motors (white details) are supplied by the customer. For more information about the PPA synchronous
operation kit, see Accessories and Spare Parts on page 46.

1. With motor 2. With PPA synchronous operation kit

www.thomsonlinear.com 35
Electrak Non-driven Actuator PPA-M
Load up to 1500 lbf

Ordering Key
1 2 3 4

PPA00 - 01B65 - 24 N-XXX

1. Model 2. Dynamic load capacity 3. Stroke 4. Bellows option


PPA00 - = Electrak PPA-M 01B65 - = 1500 lbf 04 = 4 inch N-XXX = no bellows
06 = 6 inch N-XXC = bellows
08 = 8 inch
12 = 12 inch
18 = 18 inch
24 = 24 inch
36 = 36 inch

36 www.thomsonlinear.com
Linear Actuators

www.thomsonlinear.com 37
Rotary Actuator DGB
12, 24 and 36 Vdc - load torque up to 100 lbf-in

Performance Specifications
Parameter DGB
Maximum load torque [lbf-in] 100
Speed, at no load / at maximum load [rpm]
D • • -21GB 200 / 80
D • • -30GB1 140 / 75

Standard Features and Benefits Available input voltages [Vdc] 12, 24, 36
Weight [lb]
• Rotary actuators for industrial and outdoor use D • • - • • • • - XXCL 7.7
• Easy and fast clevis mounting D • • - • • • • - XXMO 7.7
D • • - • • • • - XXDS 7.7
• Overload clutch
• Thermal protected motor Operating temperature limits [°F] -15 – +150
• Manual override or dual output shafts as option Full load duty cycle @ 77 °F [%] 25
Lead cross section [AWG] 14
Lead length [in] 7.0
Protection class IP56
General Specifications
Parameter DGB
Manual override no
Dynamic braking no
Holding brake yes
Overload protection overload clutch
Motor protection auto reset thermal switch
Motor connection flying leads and connector
Motor connector Packard Electric 56 series 2984883
with terminal 2962987. Mating
connector: 2973781 with terminal
2962573 (p/n 9100-448-001)
Certificates CE optional*
Options • manual override
• dual output shafts
• other speeds*
* Contact customer support

38 www.thomsonlinear.com
Linear Actuators

Rotary Actuator DGB


12, 24 and 36 Vdc - load torque up to 100 lbf-in
D • • - 21GB-XXCL, D • • - 30GBXXCL (clevis mount) D • • - 21GBXXMO (manual override)

D • • - 21GB-XXDS (dual output shafts)

A1: output shaft A3: first output shaft


A2: shaft for manual override A4: second ouput shaft

Performance Diagrams
Speed and Current vs. Load

V: speed I: current F: load


1: speed D12-21GB
2: speed D12-30GB
3: current D12-21GB
4: current D12-30GB

Contact customer support for data on 24 and 36 Vdc models (D • • -30GB is not available for 36 Vdc).
www.thomsonlinear.com 39
Rotary Actuator DGB
12, 24 and 36 Vdc - load torque up to 100 lbf-in

Ordering Key
1 2 3

D36 - 21GB - XXCL

1. Input voltage 2. Load torque capacity and no load speed 3. Version


D12 - = 12 Vdc 21GB - = 100 lbf-in, 200 rpm XXCL = one output shaft + clevis mount
D24 - = 24 Vdc 30GB - = 100 lbf-in, 140 rpm1 XXMO = one output shaft + manual override
D36 - = 36 Vdc XXDS = dual output shafts

Not possible with 36 Vdc input voltage.


1

Wiring Diagram
DPDT Switch
Retract
Off
Extend

(–)

Actuator
Input
Voltage Yellow

(+)

Red

Connect the red lead to positive and yellow to negative to


extend the actuator/rotate the output shaft in clockwise
direction. Change polarity to retract the actuator/rotate
the output shaft counterclockwise.

40 www.thomsonlinear.com
Linear Actuators

www.thomsonlinear.com 41
Actuator Controls
Switches

DPDT Switch

Specifications
Parameter DPDT Switch
Maximum voltage [Vac] 270
Maximum current [A] 15
Part number 830-8004-016

• Robust switch
• Double pole, double throw (DPDT) Actuator Compatibility
• 15 A rating at 270 Vac
• Center “off” Electrak 1, Electrak 1SP, Electrak 050, Electrak 2, Electrak
PPA-DC, Electrak 10, Electrak Pro, Electrak PPA-AC, Electrak
• Two momentary contacts
5, Electrak 205, DGB
• Wiring diagram on label

Wiring Diagram
Dimensions

42 www.thomsonlinear.com
Linear Actuators

Actuator Controls
Switches

DPDT Switch Box

Specifications
Parameter DPDT Box
Maximum voltage [Vac] 270
Maximum current [A] 15
Protection class NEMA 1
Part number 6932-101-054

Actuator Compatibility
• Robust rocker switch mounted in an enclosure Electrak 1, Electrak 1SP, Electrak 050, Electrak 2, Electrak
• Double pole, double throw (DPDT) PPA-DC, Electrak 10, Electrak Pro, Electrak PPA-AC, Electrak
• 15 A rating at 270 Vac 5, Electrak 205, TC16, DMD, DMA, LM80-H, LM80-V, DGB
• Center “off”
• Two momentary contacts
• Mounting bracket included Wiring Diagram
• Wiring diagram on label

Dimensions

! Note: some AC actuators require a capacitor in the wiring to run.


This capacitor will not fit in this box due to space limitations.

www.thomsonlinear.com 43
Actuator Controls
Electronic Controls

Control MCS-2041

Specifications
Parameter MCS-2041
Input voltage [Vac] 1 × 115
Input frequency [Hz] 50/60
Output voltage [Vac] 1 × 115
Maximum output current [A] 15
Protection class NEMA 1
Part number 6932-448-010
• Robust and compact metal enclosure with a front panel
extend and retract rocker switch
• Prewired internal capacitor Actuator Compatibility
• Fuse protects actuator in case of stalling caused by
Electrak 5
overload
• “Power On” light illuminates whenever power applied
to the control
Wiring Diagram
• Terminal strip for easy electrical connection
• The switch controls both the actuator motor and its anti
coast brake to provide optimum performance

Input
Voltage
Dimensions

Actuator Motor

Black
Red
Orange
Brake
White
Green

44 www.thomsonlinear.com
Linear Actuators

Actuator Controls
Electronic Controls

Control MCS-2051

Specifications
Parameter MCS-2051
Input voltage [Vac] 1 × 115
Input frequency [Hz] 50/60
Output voltage [Vac] 1 × 115
Maximum actuator output current [A] 8
Analog output signal [mA] 4 - 20
Protection class NEMA1
• Control designed to operate an Electrak 205 actuator Part number 6932-448-015
• Robust metal enclosure with front cover mounted
membrane switches and LED indicator lights for
extend, retract, jog, run and remote control Actuator Compatibility
• Emergency stop/off pushbutton remains in position
Electrak 205
when activated
• LCD display shows the extension tube position
• Internal “Run” mode jumper which causes the actuator
Wiring Diagram
to reverse automatically upon reaching the extend end of
stroke limit switch. Reverse motion continues until
reaching the retract end of stroke limit switch J4, “Run” mode jumper*
• The control provides an analog output signal for an
external customer provided control/meter
• Inputs for external extend and retract switches
• Inputs for two external end of stroke limit switches
Input
• Dynamic braking Voltage
Analog
• Terminal strip for easy electrical connection Output
4 - 20 mA

Extend
Dimensions Retract

* Inserting jumper J4 causes the actuator to reverse automatically upon reaching the extend end of
stroke limit switch. Reverse motion continues until reaching the retract end of stroke limit switch.

A1: Cable entrance, 1/2 inch standard conduit (2 ×)

www.thomsonlinear.com 45
USA, CANADA and MEXICO ASIA
Thomson Asia Pacific
203A West Rock Road Thomson
Radford, VA 24141, USA E-mail: [email protected]
Phone: +1 540 633 3549
Fax: 1 540 633 0294 China
E-mail: [email protected] Thomson
Literature: literature.thomsonlinear.com Rm 805, Scitech Tower
22 Jianguomen Wai Street
EUROPE Beijing 100004
United Kingdom Phone: +86 400 606 1805
Thomson Fax: +86 10 6515 0263
Office 9, The Barns E-mail: [email protected]
Caddsdown Business Park
Bideford, Devon, EX39 3BT India
Phone: +44 1271 334 500 Thomson
E-mail: [email protected] c/o Portescap India Pvt Ltd
1 E, first floor, Arena House
Germany Road no 12, Marol Industrial Area,
Thomson Andheri (E), Mumbai 400093 India
Nürtinger Straße 70 E-mail: [email protected]
72649 Wolfschlugen
Phone: +49 7022 504 403 Japan
Fax: +49 7022 504 405 Thomson
E-mail: [email protected] Minami-Kaneden 2-12-23, Suita
Osaka 564-0044 Japan
France Phone: +81 6 6386 8001
Thomson Fax: +81 6 6386 5022
Phone: +33 243 50 03 30 E-mail: [email protected]
Fax: +33 243 50 03 39
E-mail: [email protected] South Korea
Thomson
Italy 3033 ASEM Tower (Samsung-dong)
Thomson 517 Yeongdong-daero
Via per Cinisello 95/97 Gangnam-gu, Seoul, South Korea (06164)
20834 Nova Milanese (MB) Phone: + 82 2 6001 3223 & 3244
Phone: +39 0362 366406 E-mail: [email protected]
Fax: +39 0362 276790
E-mail: [email protected] SOUTH AMERICA
Brasil
Spain Thomson
Thomson Av. João Paulo Ablas, 2970
E-mail: [email protected] Jardim da Glória - Cotia SP - CEP: 06711-250
Phone: +55 11 4615 6300
Sweden E-mail: [email protected]
Thomson
Estridsväg 10
29109 Kristianstad
Phone: +46 44 24 67 00
Fax: +46 44 24 40 85
E-mail: [email protected]

www.thomsonlinear.com
Linear_Actuators_CTEN-0005-07 | 20190508TJ
Specifications are subject to change without notice. It is the responsibility of the product user to determine the suitability of
this product for a specific application. All trademarks property of their respective owners. ©2019 Thomson Industries, Inc.