K8 K7 K6 K5

OCB

Optional OCB-8

CA8500 – 8 Reader Access Control Board Relay


Rev.
Normal

Optional Pre- Pre- Pre- Pre-

2 3 45678
Alert Alert Alert Alert
pre-alert outputs 8 7 6 5 Pre-alert
connect to CONTROL 3 outputs if
using

O1
N
GND
external
12V
sound
Pre- Pre- Pre- Pre- EXT alert
Alert
Alert
1
Alert
2 3
Alert
4
J1
device.
ACU

Pre-alert warns when the door is


held open beyond the half interval
of the combined Door Relay Unlock
Time and the Door Held Open LED ON =
Relay
Time. Pre-alert relay is also K1 K2 K3 K4
Energized

activated on an “alarm tripped”.


Reader cable K-PROX2
18 or 22 AWG See reverse OCB
K8 K7 K6 K5

shielded cable side for Optional OCB-8


500 ft (152.4 m) termination.
maximum Relay
Rev.
Normal
KEYSCAN KEYSCAN KEYSCAN
Global Global Global Global
Optional

2 3 45678
Output Output Output Output
global outputs 8 7 6 5
connect to CONTROL 5
Shield

O1
N
GND

Optional – Pre-alert
Optional – Pre-alert

Optional – Pre-alert
Tape back Global Global Global Global
12V
EXT
shields at Output Output Output Output J1
3 4
readers. 1 2 ACU

DPS-15 Power Supply


Dual linear DC outputs: Global Outputs 1 – 8 connect
- ACU output 12 VDC @ 1.2 Amperes to 3rd party devices such as
Shield
- AUX/RDR output 12 VDC @ 1.2 Amperes alarm panel, CCTV etc. LED ON =
Relay
The total current draw on each output should not exceed 1 Amp K1 K2 K3 K4
Energized

with 200 mA in reserve for accommodating peak current OCB -8 - J 1 Relay Power
operating demands. OCB-8 powered through ribbon cable with J1 K8 K7 K6 K5
set to ACU. OCB

Optional OCB-8s may require a separate


Connect reader shields to ACU enclosure ground lug. power supply if current demand exceeds Relay
DPS-15- ACU maximum. Set J1 on EXT and Rev.
connect to separate power source. Normal

ACU Enclosure Aux Aux Aux Aux

2 3 45678
Ground Lug Auxiliary outputs connect Output Output Output Output
8 7 6 5
to
READER 8 READER 7 READER 6 READER 5 READER 4 READER 3 READER 2 READER 1
CONTROL 2

O1
N
GND

p/n CAS6105 S3 OCB-8


S2
Cold Water

O 1 2 3 4 5 6 7 8 9 10 11 12
12V
Aux Aux
Ground PSC1
Immediately after the Aux Aux EXT

CONTROL 3
CARD Output Output Output Output J1

Connect to PSC1 READER PWR


BITS control board is powered 1 2 3 4 ACU

sockets on CA8500B - 10s 1s up for the first time, press


& DPS-15 + S1, wait 5 seconds, then

N
FAIL
- press S3 within 10 S1 Aux Outputs 1 – 8 connect
+
seconds to load factory to 3rd party devices such as
FAIL
ACU PWR defaults. alarm panel, CCTV or door LED ON =
locks without readers. Relay

CONTROL 2
CONTROL 5
S4 Energized
K1 K2 K3 K4
O1 2

SYSTEM STATUS COMMUNICATION STATUS


N

AC AC - + FAIL - + - + FAIL AC AC
AUX/RDR BATT AUX/RDR EGND ACU ACU TD1 RD1 TD2 RD2 TD3 RD3 TD4 RD4
PSC1 Optional OCB-8 OCB
K8 K7 K6 K5

Enlarged view of
reader terminal

CONTROL 1
CONTROL 4
Relay

Operating Temperature READER X


Rev.
Normal
DPS15
TP1 32°F to 120°F C1
LED
D1 D0 PWR GND
(0°C to 49°C) (Beep) WHT GRN RED BLK Optional HC HC HC HC

2 3 45678
Dual Power Supply TP2
Output Output Output Output
TP3 Humidity HC outputs 8 7 6 5
+
TP4 0% to 90% R.H., - connect to CONTROL 4
TAMPER (TB3)

O1
non-condensing

N
TP5 SWITCH GND
GND CTS
DTR
AC AC DCD
12V
AUX/RDR ACU RD
TD HC HC HC HC EXT
GND Output Output Output Output J1
RS-232 (COM4) 1 2 3 4 ACU
Either two - 16V 40VA or Credentials with Accessibility or
16.5V 37VA transformers mounted Extended Entry designations pulse
externally. ACU Protective Cover IOCB (COM1)
the HC output. System monitors
RX
TX Tamper Switch door
on ACU
Control Board Current – 130 mA Enclosure
contact for Accessibility/Extended LED ON =
Relay
ETHERNET M1
Primary Entry Door Held Open time. K1 K2 K3 K4
Energized

110 VAC Accessibility HC output


OCB -8 connects to motorized
The PC109x control board emits an Current – 230 mA door hardware on door
- 12 VDC intermittant beep if: CA 8500B Relays – Form C #2.
H2 H1
Battery A) a back-up battery is not connected contacts
7 to 8 AH K8 K7 K6 K5
+ B) two (2) transformers are not DOOR INPUTS - A COMMON
1 2 3 4 5 6 7 8
RTE INPUTS - B
1 2 3 4 5 6 7 8
COMMON AUX INPUTS - C COMMON
1 2 3 4 5 6 7 8
AUX INPUTS - D COMMON
9 10 11 1213 14 15 16
AUX INPUTS - E
17 18 19 20 2122 23 24 – 5 A / 30 VDC OCB

connected – 10 A / 24 VAC
Relay
Rev.
Run Mode Fire Contact
Normal
Connect ribbon cable from Door outputs breaks on alarm
Door Door Door Door
connect to

2 3 45678
Common
HDR1 terminal on CIM to Output Output Output Output
H2 CONTROL 1 8 7 6 5

terminal on control board. N.C.


Door Contact

O1
N
Door # 1 CIM with Network or Serial GND

N.C. Connection
(CIM 0) 12V

Jumper ON J4
Door Door Door Door EXT +
Common Output Output Output Output J1

PC with
Program Mode
To program NETCOM
1 2 3 4 ACU
+ DC
Communication - Supply
Connect all common cables to COMMON terminals on control board

Door Contact 2P/6P


Door # 2 Manager -
when plugged into CIM,
N.C. place a jumper ON J12.
to After programming, remove LED ON =
Relay
Common network jumper from J12 to reset K1 K2 K3 K4
Energized

(TCP/IP) CIM board for Run mode.


to
N.O. network J7
V+ CAN2 -

Door # 1 Exit Push Button


(TCP/IP) (+12 V)
J8 Door Strike
Ethernet
GND HDR1
CAN2
+ Maglock
COM1 CAN1
J5
J6
EGND
(Fail Safe) (Fail Secure)
GND
Common N.O. TD1
-
CAN1 Door Output # 1 Door Output # 2
+
RD1
PIR - +
RTS
+
½ second pulse CTS RESET Diode
COM1
DC CIM
COM2
J1 CIM 0 1N4004
GND GND
Door # 2 Exit Device Supply Serial RS-232 TD2
Jumper ON J4 -
TD1
Green

Connection RD2 J4 J10 J11


J9
Black

J3
RD1 RTS
NETCOM2P or
CTS
NETCOM6P
Red

B3B2B1B0 Diag Power


to RTS Good
Fault
J12
Door Lock Cable 18 AWG
1 2 1 2 1 2 1 2 J2
Common ground Rx-COMCAN COMCAN-Tx (Flashing)

White & lug CTS


Aux Input
Aux Input Brown not
used.
CIM to CIM
N.C.
N.C. Shield* - CAT 5
- 2 twisted pairs
Tape 5 conductor Bit Rate / Distance - maximum cable distance first CIM to last CIM - 3280 ft (1000 m)
back 22 AWG shielded Bit CAN Bus RS-232
shield. @ 9600 baud
Door contacts, exit devices, or PIRs - 22 AWG cable 9600 3280' (999.7m) 49.2' (14.9 m) CIM with network or serial connection
N.C. = Normally Closed 19200* 3280' (999.7m) 49.2' (14.9 m) = CIM 0 – jumper ON J4
* Insulate shield with
N.O. = Normally Open 57600984' (299.9m) 26.2' (7.9 m) See over for more on CIM to CIM CAN Bus connections and
PVC tubing such as
115200* 262' (80 m) 9.84' (3 m)
Green

Black
Red

Alpha (p/n PVC10516 jumper settings


16 AWG) or * not applicable for reverse network communication .
to
comparable insulator. Also refer to the CIM
PC
– Setup Guide.

CA8500 Control Board – Serial # _________ (Communication address) / NETCOM Device – IP Address ___________________________ Subnet Mask ____________________________
Name
Door # 1 ___________________________ Reader # / Direction ______________ Name
Door # 2 ___________________________ Reader # / Direction ______________ AI/SI # 1 _______________________ AI/SI # 9 ______________________
Door # 3 ___________________________ Reader # / Direction ______________ AI/SI # 2 _______________________ AI/SI # 10 ______________________
Door # 4 ___________________________ Reader # / Direction ______________ AI/SI # 3 _______________________ AI/SI # 11 ______________________
Door # 5 ___________________________ Reader # / Direction ______________ AI/SI # 4 _______________________ AI/SI # 12 ______________________
Door # 6 ___________________________ Reader # / Direction ______________ AI/SI # 5 _______________________ AI/SI # 13 ______________________
Door # 7 ___________________________ Reader # / Direction ______________ AI/SI # 6 _______________________ AI/SI # 14 ______________________
Door # 8 ___________________________ Reader # / Direction ______________ AI/SI # 7 _______________________ AI/SI # 15 ______________________
AI/SI # 8 _______________________ AI/SI # 16 ______________________

CA8500 – 8 Reader Access Control Board – Rev. PC109x 10.15 – Document # KD10011-E