Sample Inspection Report Date:
12/03/2024
Document
00000000
Customer: GREE Contact: ------------- Telephone:
Description: CABO DE LIGAÇÃO 3X2,50mm² 2,0m PRETO B400205401 Application: AR CONDICIONADO
P/N Customer: B400205401 P/N I-Sheng: ----------------------- Sample size: 05 pcs
PLUG DESCRIPTION RAW CABLE DESCRIPTION CONSTRUCTION CABLE
STRAIN RELIEF / CONNECTOR
CURRENT/ TENSION (N°/mm)
(INMETRO) 005330/2017 (UL BR) OCP-0029 I-SHENG BRIS 3X2.50mm² 300/500V FABRICADO NO BRASIL 247 NM PRODUCT
53-C5 CABO FLEXIVEL CIRCULAR ABNT NBR NM247-5 (UL BR) H05VV-F 60227 IEC 53 IEC 60227-5 CB PP 3X2.50mm² NBR NM247-5 WEIGHT
N.A N.A
44/0.254 (kg/pc)
1) USED MATERIAL
DECISION
0,312kg
N° MATERIALS REFERENCE STANDARD SUPPLIER
NG G
01 CB 3X2,50MM2 300/500V FLEX CIRCULAR PRETO BRIS H05VV-F FTALATO FREE NBR NM247-5 / IEC60227 I-SHENG BRIS - OK
2) DRAWING
3) DIMENSIONAL
FOUND INSTRUMEN DECISION
N° SPECIFICATION (mm)
#1 #2 #3 #4 #5 #6 #7 #8 #9 #10 T NG G
01 L1 - 2000 + 50 mm 2005 2004 2005 2003 2005 - - - - - Sacale - OK
02 L2 - 100 + 10 mm 102 101 102 102 101 - - - - - Sacale - OK
03 L3 - 100 + 10 mm 100 102 102 101 102 - - - - - Sacale - OK
4) ELECTRICAL TEST
N° PARAMETER TEST EQUIPAMENT #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 TEST MARKING DECISION
ELECTRICAL
TEST
CONTINUIDA
01 - - - - - - - - - - NA NA
DE (Voltage
4kV Corrent
3mA / 2 Seg.)
5) CRIMPING TEST
TERMINAL CRIMP
Conductor Crimp Height (mm) Terminal Extraction Force (N)
N°
Cable Wire
Component Found Found Machine / Equipament Components / Cross Section
Construction Specification Specification
Crimp Height Extraction
(mm) #1 #2 #3 Force (N) #1 #2 #3
NA - - -
3G 2.50mm²
01 NA NA - - - NA NA
(44/0.254)
NA - - -
6) CHECKUP VISUAL
N° EVENTS METODOLOGIA CONCLUSION RESULT
01 Cable lengths must meet Customer's drawing dimensions. VISUAL MEETS SPECIFICATION OK
02 There must be no cables with damaged insulation. VISUAL NOT FOUND OK
03 All materials must meet customer recommendations. VISUAL MEETS SPECIFICATION OK
04 Terminal crimps must meet the Client specification. VISUAL MEETS SPECIFICATION OK
05 The cable section must meet customer specification VISUAL MEETS SPECIFICATION OK
06 There should be no plastic injection flaws in the power cord plug and connector. VISUAL NOT FOUND OK
07 There must be no reversal of the wires when connecting the terminals to the housing. VISUAL NOT FOUND OK
PASS APPROVE BY CHECK BY MADE BY
DATE: 12/03/2024
FAIL ANNE SANTOS ANNE SANTOS MOSES NOGUEIRA
F-PG05-04-A