Mathcad - Column C-1
Mathcad - Column C-1
CONTENTS
A. B. C. D. INPUT DATA DESIGN LOADS ANALYSIS RESULTS SUMMARY
Page 1 of 7
LNT4 - Dec.2011
COLUMN := "C1"
A.2
COLUMN DIMENSIONS
Dimension parallel to x-axis Dimension parallel to y-axis b := 200mm t := 400mm
A.3
0 0 0
1 0 0
2 8 50
T
3 10 100
4 12 127
5 16 200
6 20 300
T
7 22 387
2
8 25 500
9 28 616
10 30 700
No := No
A.4
COLUMN REINFORCEMENTS
Diameter of main reinforcements Bar designation no. Bar diameter Area of one (1) bar Diameter of ties Tie bar designation no. Tie diameter Area of one (1) tie bar
3 5
Page 2 of 7
LNT4 - Dec.2011
A.5
SKETCH PLAN
CROSS SECTION
X-axis
Y-axis
A.6
Ag = 80000 mm
Page 3 of 7
LNT4 - Dec.2011
Ast Ag
B.
DESIGN LOADS
From STAAD Analysis and Design Output
STAAD_File := "2-Storey Residential.std" Member := 53
Case Considered
Load_Casecol = 206 Axial Force Moment about X-axis Moment about Y-axis Shear along X-axis Shear along Y-axis Pucol = 86.44 kN Muzcol = 33.13 kN m Muycol = 0.53kN m Vuzcol = 0.23 kN Vuycol = 12.84kN
Page 4 of 7
LNT4 - Dec.2011
INTERACTION DIAGRAMS
X-Axis Interaction Diagram
Pnx (kN) 1215.61 972.48 972.48 863.22 758.03 666.76 517.87 168.00 0.00 -297.00
Mnx (kN-m) ey (mm) 0.00 0.00 38.34 49.93 58.32 64.01 71.14 58.65 0.00 0.00 0.00 39.43 57.84 76.93 96.00 137.37 349.13 0.00 0% 25% 50% 100%
Comments Nom. max. compression = Po Allowable Pn (max) = 0.8*Po Min. eccentricity rebar tension = 0.0 MPa rebar tension = 68.8 MPa rebar tension = 137.5 MPa rebar tension = 275.0 MPa Pn = 0.1*f c'*A g Pure moment capacity Pure axial tension capacity
Pnx (kN)
500
47.56 (infinity)
1.5 10
Pny (kN) 1215.61 972.48 972.48 711.26 620.37 541.04 392.56 168.00 0.00 -297.00
Mny (kN-m) ex (mm) 0.00 0.00 17.65 28.46 30.57 31.94 33.06 25.10 0.00 0.00 0.00 18.15 40.01 49.27 59.04 84.23 149.43 0.00 0% 25% 50% 100%
Comments Nom. max. compression = Po Allowable Pn (max) = 0.8*Po Min. eccentricity rebar tension = 0.0 MPa rebar tension = 68.8 MPa rebar tension = 137.5 MPa rebar tension = 275.0 MPa Pn = 0.1*f c'*A g Pure moment capacity Pure axial tension capacity
Pny (kN)
500
22.00 (infinity)
Page 5 of 7
LNT4 - Dec.2011
Member Uniaxial Capacity at Design Eccentricity, ex: Axial Moment Eccentricity Pny = 972.485kN Mny = 22.002kN m ex = 6.131 mm
Biaxial Capacity and Stress Ratio for P u 0.1fc' Ag 1 1 1 1 = + P rxy P rx Pry Po Factored Axial Resistance on the basis that only eccentricity ey is present Factored Axial Resistance on the basis that only eccentricity ex is present
P rx := Pnx
P rx = 152.643kN
P ry := Pny
P ry = 972.485kN
P o = 0.85fc' ( Ag Ast) + fy Ast Factored Maximum Axial Resistance Factored Axial Resistance in Biaxial Flexure Po := c P o P rxy :=
1 P rx
Stress Ratio
, "Not Applicable"
Mutcol Mrx
1.15
Mulcol Mry
1.15
LNT4 - Dec.2011
Muzcol Mrx
1.15
Muycol Mry
1.15
, "Not Applicable"
SR = 0.534
D.
SUMMARY
COLUMN = "C1"
COLUMN DIMENSIONS Dimension parallel to x-axis Dimension parallel to y-axis VERTICAL REINFORCEMENTS b = 200 mm t = 400 mm
VERTICAL_BARS = "6 - 16mm bars" TRANSVERSE REINFORCEMENT Hoop/Stirrups Size Spacing of hoops ties = 10mm Spchoops := min ( 16 bar , 48 ties , b , t) Spchoops = 200 mm
Page 7 of 7
LNT4 - Dec.2011