L&T Electrical & Automation (E&A) Final Distribution Products

E&A’s range of modular devices offer MCB, RCCB, Isolator & DB for final distribution of electrical power.
E&A’s products are better known for reliability, functionality & ease of use.

E&A products conform to relevant


E&A Final Distribution Products global standards viz. IEC, EN.
spell world class They also have BIS, marking,
CB and certification.

Contents

MCB - Miniature Circuit Breaker 2

Isolators 6

RCCB - Residual Current Circuit Breaker 7

Other Protection & Control Devices 8

Distribution Boards 10

Industrial Plugs & Sockets 16

Note:
[Grey colour : HSN code]
Current GST 18%, subject to changes
as per Govt. notification EN
E&A Final Distribution Products - the assurance of absolute safety

Safety re-defined
Finger proof terminals eliminate chances of accidental contact with live part.
You can install, operate and maintain modular device with total confidence.

Energy limiting class - 3


If fault occurs, the Rapid Arc Quenching mechanism in modular device operates
and extinguishes the arc quickly (within 3-5 msec), ensuring lowest possible
energy flow through the circuit. This minimize risk of fire and maximizes life of
your equipment.

Safety meets superior aesthetics


Ergonomically designed, profiled for superior cooling and manufactured with
fire retardant material. Modular device is brought to you keeping in mind utmost
user safety.

Key Benefits

True contact indication


E&A modular device range enhances safety through true contact indication even
from a distance regardless of its mounting and knob position. Red and Green
indication tags provided below the knob positively identify the electrical ON/OFF
status, reflecting actual contact status.

Integrated label holder


E&A MCBs are equipped with label holder for easy identification of circuit during
operation as well as in maintenance.

Innovatively profiled breathing channels


When two or more poles are placed adjacent to each other, the breathing
channels are so profiled that the air circulates around individual pole, resulting in
cooler operation.

Large terminal size and Biconnect


Exora MCB’s can easily accommodate cables of up to 35 sq.mm. Biconnect
terminals offer convenience of connecting both cable and bus bar.

Two position DIN rail clip


Installation on a DIN rail is further simplified with a two-position DIN rail clip as a
standard feature. E&A MCB range makes mounting on a standard DIN rail more
convenient .

Non-welding contacts
Silver Graphite contact tips ensure higher life and maximum safety against
contact welding due to its superior anti-welding properties, enhancing safety
and life of the system.

Combihead screw
E&A modular devices with combihead screws, allow you to use standard as well
as Philips head screw drivers. E&A modular device range addresses your
undefined needs.

Lauritz Knudsen, 01.05.2024 1


Miniature Circuit Breaker (MCB) [8536]

Range Highlights
› True contact indication for individual pole › Available in B, C & D curves
› Label holder facility for all configurations › Low watt loss - almost 50% of the values prescribed by IS/IEC 60898
› Conforms to IS/IEC 60898 - 10kA › Trip free mechanism
› Design based on advanced current limiting hammer trip mechanism
› Conforms to IEC 60947 - 2 › No Line-Load bias
» 15kA C-curve till 40 A › Bi connect feature on both side
» 10kA C-curve for 50A, 63A › Suitable for accessory fitment

Modules M.R.P. M.R.P. M.R.P.


Rating B-Curve C-Curve D-Curve
1 Mod = (`) (`) (`)
Cat. No. Cat. No. Cat. No.
17.5 mm Per Unit Per Unit Per Unit

Single Pole (SP)

0.5A 1 - - BB10E50C 455 BB10E50D 460


1A 1 - - BB10010C 455 BB10010D 460
2A 1 - - BB10020C 455 BB10020D 460
3A 1 - - BB10030C 455 BB10030D 460
4A 1 - - BB10040C 455 BB10040D 460
6A 1 BB10060B 280 BB10060C 280 BB10060D 385
10A 1 BB10100B 280 BB10100C 280 BB10100D 385
16A 1 BB10160B 280 BB10160C 280 BB10160D 385
20A 1 BB10200B 280 BB10200C 280 BB10200D 385
25A 1 BB10250B 280 BB10250C 280 BB10250D 385
32A 1 BB10320B 280 BB10320C 280 BB10320D 385
40A 1 BB10400B 645 BB10400C 645 BB10400D 695
50A 1 BB10500B 645 BB10500C 645 BB10500D* 695
63A 1 BB10630B 645 BB10630C 645 BB10630D* 695

Double Pole (DP)

0.5A 2 - - BB20E50C 1270 BB20E50D 1290


1A 2 - - BB20010C 1270 BB20010D 1290
2A 2 - - BB20020C 1270 BB20020D 1290
3A 2 - - BB20030C 1270 BB20030D 1290
4A 2 - - BB20040C 1270 BB20040D 1290
6A 2 BB20060B 910 BB20060C 910 BB20060D 940
10A 2 BB20100B 910 BB20100C 910 BB20100D 940
16A 2 BB20160B 910 BB20160C 910 BB20160D 940
20A 2 BB20200B 910 BB20200C 910 BB20200D 940
25A 2 BB20250B 910 BB20250C 910 BB20250D 940
32A 2 BB20320B 910 BB20320C 910 BB20320D 940
40A 2 BB20400B 1470 BB20400C 1470 BB20400D 1535
50A 2 BB20500B 1470 BB20500C 1470 BB20500D* 1535
63A 2 BB20630B 1470 BB20630C 1470 BB20630D* 1535

Three Pole (TP)

0.5A 3 - - BB30E50C 1865 BB30E50D 1895


1A 3 - - BB30010C 1865 BB30010D 1895
2A 3 - - BB30020C 1865 BB30020D 1895
3A 3 - - BB30030C 1865 BB30030D 1895
4A 3 - - BB30040C 1865 BB30040D 1895
6A 3 BB30060B 1450 BB30060C 1450 BB30060D 1510
10A 3 BB30100B 1450 BB30100C 1450 BB30100D 1510
16A 3 BB30160B 1450 BB30160C 1450 BB30160D 1510
20A 3 BB30200B 1450 BB30200C 1450 BB30200D 1510
25A 3 BB30250B 1450 BB30250C 1450 BB30250D 1510
32A 3 BB30320B 1450 BB30320C 1450 BB30320D 1510
40A 3 BB30400B 2235 BB30400C 2235 BB30400D 2340
50A 3 BB30500B 2235 BB30500C 2235 BB30500D* 2340
63A 3 BB30630B 2235 BB30630C 2235 BB30630D* 2340

Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.
* For details, please contact nearest branch office

Lauritz Knudsen, 01.05.2024 2


Miniature Circuit Breaker (MCB) [8536]

Modules M.R.P. M.R.P. M.R.P.


Rating B-Curve C-Curve D-Curve
1 Mod = (`) (`) (`)
Cat. No. Cat. No. Cat. No.
17.5 mm Per Unit Per Unit Per Unit
Four Pole (FP)
0.5A 4 - - BB40E50C 2345 BB40E50D 2350
1A 4 - - BB40010C 2345 BB40010D 2350
2A 4 - - BB40020C 2345 BB40020D 2350
3A 4 - - BB40030C 2345 BB40030D 2350
4A 4 - - BB40040C 2345 BB40040D 2350
6A 4 BB40060B 1980 BB40060C 1980 BB40060D 2030
10A 4 BB40100B 1980 BB40100C 1980 BB40100D 2030
16A 4 BB40160B 1980 BB40160C 1980 BB40160D 2030
20A 4 BB40200B 1980 BB40200C 1980 BB40200D 2030
25A 4 BB40250B 1980 BB40250C 1980 BB40250D 2030
32A 4 BB40320B 1980 BB40320C 1980 BB40320D 2030
40A 4 BB40400B 2805 BB40400C 2805 BB40400D 3010
50A 4 BB40500B 2805 BB40500C 2805 BB40500D* 3010
63A 4 BB40630B 2805 BB40630C 2805 BB40630D* 3010

Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP- 4 Nos., FP - 3 Nos.

MCBs (Miniature Circuit Breakers) : 80A-125A [8536]


Range Highlights
› Short circuit Breaking Capacity - 15kA (IEC 60947-2, EN 60947-2) › Suitable for Isolation
› C & D Characteristics › Protection Degree - IP 20
› Available in SP, DP, TP and FP › Availability of wide Range of Site Mountable Accessories

C Curve M.R.P. D Curve M.R.P.


Rating Module (`) (`)
Cat. No. Per Unit Cat. No. Per Unit
Single Pole (SP)
80A 1.5 AU15S10803C 2550 AU15S10803D 2900
100A 1.5 AU15S11003C 2855 AU15S11003D 3245
125A 1.5 AU15S11253C 3070 AU15S11253D 3510
Double Pole (DP)
80A 3 AU15S20803C 5650 AU15S20803D 6430
100A 3 AU15S21003C 6025 AU15S21003D 6855
125A 3 AU15S21253C 6630 AU15S21253D 7540
Three Pole (TP)
80A 4.5 AU15S30803C 8915 AU15S30803D 10150
100A 4.5 AU15S31003C 9505 AU15S31003D 10805
125A 4.5 AU15S31253C 10545 AU15S31253D 11985
Four Pole (FP)
80A 6 AU15S40803C 11640 AU15S40803D 13215
100A 6 AU15S41003C 12105 AU15S41003D 13775
125A 6 AU15S41253C 13710 AU15S41253D 15585

Lauritz Knudsen, 01.05.2024 3


Customer Interaction Center (CIC)
Phone no: 022 6932 7800
Web: www.LK-EA.com | e-mail: [email protected]
Miniature Circuit Breaker (MCB) [8536]

DC MCBs as per IEC 60947-2 [8536]


Rated Voltage: Rated Voltage:
Breaking capacity of 6 kA - BB Series DC MCBs Breaking capacity of 10 kA - BJ Series DC MCBs

130V DC SP MCB 250V DC SP MCB


Modules M.R.P. Modules M.R.P.
Rating 1 Mod = Cat. No. (`) Rating 1 Mod = Cat. No. (`)
17.5mm Per Unit 17.5mm Per Unit
Single Pole (SP) Single Pole (SP)
0.5A 1 BB10E5DC 660 0.5A 1 BJ10E5DC 810
1A 1 BB1001DC 660 1A 1 BJ1001DC 810
2A 1 BB1002DC 660 2A 1 BJ1002DC 810
3A 1 BB1003DC 660 3A 1 BJ1003DC 810
4A 1 BB1004DC 660 4A 1 BJ1004DC 810
6A 1 BB1006DC 570 6A 1 BJ1006DC 660
10A 1 BB1010DC 570 10A 1 BJ1010DC 660
16A 1 BB1016DC 570 16A 1 BJ1016DC 660
20A 1 BB1020DC 570 20A 1 BJ1020DC 660
25A 1 BB1025DC 570 25A 1 BJ1025DC 660
32A 1 BB1032DC 570 32A 1 BJ1032DC 660
40A 1 BB1040DC 750 40A 1 BJ1040DC 915
50A 1 BB1050DC 750 50A 1 BJ1050DC 915
63A 1 BB1063DC 750 63A 1 BJ1063DC 915

250V DC DP MCB 500V DC DP MCB


0.5A 2 BB20E5DC 1410 0.5A 2 BJ20E5DC 1690
1A 2 BB2001DC 1410 1A 2 BJ2001DC 1690
2A 2 BB2002DC 1410 2A 2 BJ2002DC 1690
3A 2 BB2003DC 1410 3A 2 BJ2003DC 1690
4A 2 BB2004DC 1410 4A 2 BJ2004DC 1690
6A 2 BB2006DC 1240 6A 2 BJ2006DC 1430
10A 2 BB2010DC 1240 10A 2 BJ2010DC 1430
16A 2 BB2016DC 1240 16A 2 BJ2016DC 1430
20A 2 BB2020DC 1240 20A 2 BJ2020DC 1430
25A 2 BB2025DC 1240 25A 2 BJ2025DC 1430
32A 2 BB2032DC 1240 32A 2 BJ2032DC 1430
40A 2 BB2040DC 1680 40A 2 BJ2040DC 1820
50A 2 BB2050DC 1680 50A 2 BJ2050DC 1820
New 63A 2 BB2063DC 1680
New 63A 2 BJ2063DC 1820

Note Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos.


1000V DC MCBs [8536]
Rated Voltage:1000V DC
with breaking capacity of 6 kA - BK Series DC MCBs
New Description
Modules M.R.P. (`)
1 Mod = 17.5mm Cat. No. Per Unit
DP 6A 1000V DC 6kA MCB 4 BK2006DC 2245
DP 10A 1000V DC 6kA MCB 4 BK2010DC 2245
DP 16A 1000V DC 6kA MCB 4 BK2016DC 2245
DP 20A 1000V DC 6kA MCB 4 BK2020DC 2245
DP 25A 1000V DC 6kA MCB 4 BK2025DC 2245
DP 32A 1000V DC 6kA MCB 4 BK2032DC 2245
DP 40A 1000V DC 6kA MCB 4 BK2040DC 2725
DP 50A 1000V DC 6kA MCB 4 BK2050DC 2725
DP 63A 1000V DC 6kA MCB 4 BK2063DC 2725

Solar Combo MCBs [8536] (AC MCB + DC MCB)


Modules M.R.P. (`)
Description 1 Mod = 17.5mm Cat. No. Per Unit
1 AC 16A DP MCB^ + 1 DC 16A DP 500V MCB 2+2 SC221616 1805
1 AC 25A DP MCB^ + 1 DC 16A DP 500V MCB 2+2 SC222516 1805
1 AC 32A DP MCB^ + 1 DC 16A DP 500V MCB 2+2 SC223216 1805
1 AC 32A DP MCB^ + 1 DC 32A DP 500V MCB 2+2 SC223232 1805
^AC MCB with C-Curve
Lauritz Knudsen, 01.05.2024 5
Isolators [8536]

Range Highlights
› Conforms to IEC 60947-3
› Utilization category AC-22A
› Available in DP, TP and FP versions in 40A, 63A, 80A & 100A ratings

M.R.P. M.R.P. M.R.P.


Rating Modules Modules Modules
Cat. No. (`) Cat. No. (`) Cat. No. (`)
1 Mod = 17.5 mm 1 Mod = 17.5 mm 1 Mod = 17.5 mm
Per Unit Per Unit Per Unit
Double Pole (DP) Three Pole (TP) Four Pole (FP)
40A 2 BF204000 555 3 BF304000 965 4 BF404000 1250
63A 2 BF206300 715 3 BF306300 1125 4 BF406300 1305
80A 2 BF208000 910 3 BF308000 1235 4 BF408000 1465
100A 2 BF210000 950 3 BF310000 1315 4 BF410000 1580

Note: Standard Pack Quantity for Isolator : DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.

RCCB (Residual Current Circuit Breaker ) [8536]

Range Highlights
› Conforms to IS 12640 (Part 1) / IEC 61008-1 › Truly current operated - operation even at nominal
voltage
› RCCBs are available in DP and FP versions from › Operates on Core Balance Current Transformer
25 to 100A ratings with 30 mA, 100 mA and 300mA (CBCT) principle
sensitivity
› Advanced neutral mechanism
M.R.P. M.R.P.
Rating Sensitivity Modules Rating Sensitivity Modules
Cat. No. (`) Cat. No. (`)
1 Mod =17.5 mm 1 Mod =17.5 mm
Per Unit Per Unit
Double Pole (DP) Four Pole (FP)
30 mA 2 BG202503 3205 30 mA 4 BG402503 4235
25A 100 mA 2 BG202510 3330 25A 100 mA 4 BG402510 4345
300 mA 2 BG202530 3330 300 mA 4 BG402530 4345
30 mA 2 BG204003 3595 30 mA 4 BG404003 4275
40A 100 mA 2 BG204010 3805 40A 100 mA 4 BG404010 4420
300 mA 2 BG204030 3805 300 mA 4 BG404030 4420
30 mA 2 BG206303 4485 30 mA 4 BG406303 4835
63A 100 mA 2 BG206310 4595 63A 100 mA 4 BG406310 5070
300 mA 2 BG206330 4595 300 mA 4 BG406330 5070
30 mA 2 BG210003 7825 30 mA 4 BG410003 8345
100A 100 mA 2 BG210010 7925 100A 100 mA 4 BG410010 8490
300 mA 2 BG210030 7925 300 mA 4 BG410030 8490

RCCBs (Residual Current Circuit Breakers) : Type-Adi (with Added immunity)[8536]

Range Highlights
› Wide Range of Current Ratings - 25A to 100A
› Precise Sensitivities for variety of applications - from 30mA to 300mA
› 2P & 4P versions
› Suitable for Isolation
› Protection Degree - IP 20
› Availability of wide Range of Site Mountable Accessories
› Type Adi: Suitable for AC + Pulsating DC (Type A) + Harmonics
M.R.P. Rating Sensitivity M.R.P. (`)
Rating Sensitivity CAT Nos. Module CAT Nos.
Module (`) Per Unit
Per Unit
4P Adi
2P Adi
30mA 4 AURAD402503 6200
30mA 2 AURAD202503 5130
25A 100mA 4 AURAD402510 6320
25A 100mA 2 AURAD202510 5360
300mA 4 AURAD402530 6320
300mA 2 AURAD202530 5360
30mA 4 AURAD404003 6440
30mA 2 AURAD204003 5445
40A 100mA 4 AURAD404010 6540
40A 100mA 2 AURAD204010 5530
300mA 4 AURAD404030 6540
300mA 2 AURAD204030 5530
30mA 4 AURAD406303 7010
30mA 2 AURAD206303 6365
63A 100mA 4 AURAD406310 7155
63A 100mA 2 AURAD206310 6485
300mA 4 AURAD406330 7155
300mA 2 AURAD206330 6485
30mA 4 AURAD410003 11165
100A 30mA 2 AURAD210003 9405 100A
300mA 4 AURAD410030 11165

Lauritz Knudsen, 01.05.2024 6


RCBOs (Residual Current Breaker with Overcurrent Protection) [8536]

Range Highlights*
› Conforms to IEC 61009-1, IS 12640-2, EN 61009-1 › Availability of wide Range of
› Short circuit Breaking Capacity - 10kA Site Mountable Accessories
› Precise Sensitivities for a variety of applications › Available in
» from 10mA to 300mA » Type AC: For standard AC installations
› Suitable for Isolation » Type Adi: Suitable for AC +
Pulsating DC (Type A) + Harmonics
Type-AC Type-Adi
Rating Sensitivity M.R.P. (`) Rating Sensitivity M.R.P. (`)
Module CAT Nos. Module CAT Nos.
Per Unit Per Unit
2P AC 2P Adi
10mA 2 AUF3C200601 4745 30mA 2 AUF3D200603 6285
30mA 2 AUF3C200603 4745 6A 100mA 2 AUF3D200610 6920
6A
100mA 2 AUF3C200610 4845 300mA 2 AUF3D200630 7180
300mA 2 AUF3C200630 4900 30mA 2 AUF3D201003 6285
10mA 2 AUF3C201001 4745 10A 100mA 2 AUF3D201010 6920
30mA 2 AUF3C201003 4745 300mA 2 AUF3D201030 7180
10A
100mA 2 AUF3C201010 4845 30mA 2 AUF3D201603 6285
300mA 2 AUF3C201030 4900 16A 100mA 2 AUF3D201610 6920
10mA 2 AUF3C201601 4745 300mA 2 AUF3D201630 7180
30mA 2 AUF3C201603 4745 30mA 2 AUF3D202003 6285
16A
100mA 2 AUF3C201610 4845 20A 100mA 2 AUF3D202010 6920
300mA 2 AUF3C201630 4900 300mA 2 AUF3D202030 7180
30mA 2 AUF3C202003 4745 30mA 2 AUF3D202503 6285
20A 100mA 2 AUF3C202010 4845 25A 100mA 2 AUF3D202510 6920
300mA 2 AUF3C202030 4900 300mA 2 AUF3D202530 7180
30mA 2 AUF3C202503 4745 30mA 2 AUF3D203203 6285
25A 100mA 2 AUF3C202510 4845 32A 100mA 2 AUF3D203210 6920
300mA 2 AUF3C202530 4900 300mA 2 AUF3D203230 7180
30mA 2 AUF3C203203 4745 30mA 2 AUF3D204003 6285
32A 100mA 2 AUF3C203210 4845 40A 100mA 2 AUF3D204010 6920
300mA 2 AUF3C203230 4900 300mA 2 AUF3D204030 7180
30mA 2 AUF3C204003 4745 30mA 4 AUF3D206303 7665
40A 100mA 2 AUF3C204010 4845 63A 100mA 4 AUF3D206310 8110
300mA 2 AUF3C204030 4900 300mA 4 AUF3D206330 8180
30mA 4 AUF3C206303 5940 4P Adi
63A 100mA 4 AUF3C206310 6300 30mA 7.5 AUF3D401603 6925
300mA 4 AUF3C206330 6350 16A 100mA 7.5 AUF3D401610 7705
4P AC 300mA 7.5 AUF3D401630 7860
30mA 7.5 AUF3C401603 5370 30mA 7.5 AUF3D402003 6925
16A 100mA 7.5 AUF3C401610 5980 20A 100mA 7.5 AUF3D402010 7705
300mA 7.5 AUF3C401630 6100 300mA 7.5 AUF3D402030 7860
30mA 7.5 AUF3C402003 5370 30mA 7.5 AUF3D402503 6925
20A 100mA 7.5 AUF3C402010 5980 25A 100mA 7.5 AUF3D402510 7705
300mA 7.5 AUF3C402030 6100 300mA 7.5 AUF3D402530 7860
30mA 7.5 AUF3C402503 5370 30mA 7.5 AUF3D403203 7150
25A 100mA 7.5 AUF3C402510 5980 32A 100mA 7.5 AUF3D403210 7710
300mA 7.5 AUF3C402530 6100 300mA 7.5 AUF3D403230 7870
30mA 7.5 AUF3C403203 5545 30mA 7.5 AUF3D404003 7255
32A 100mA 7.5 AUF3C403210 5985 40A 100mA 7.5 AUF3D404010 7710
300mA 7.5 AUF3C403230 6115 300mA 7.5 AUF3D404030 7905
30mA 7.5 AUF3C404003 5635 30mA 7.5 AUF3D406303 8695
40A 100mA 7.5 AUF3C404010 5985 63A 100mA 7.5 AUF3D406310 8870
300mA 7.5 AUF3C404030 6135 300mA 7.5 AUF3D406330 8870
30mA 7.5 AUF3C406303 6750 30mA 12 AUF3D408003 25685
63A 100mA 7.5 AUF3C406310 6875 80A 100mA 12 AUF3D408010 26260
300mA 7.5 AUF3C406330 6875 300mA 12 AUF3D408030 26260
30mA 12 AUF3C408003 25685 30mA 12 AUF3D410003 27460
80A 100mA 12 AUF3C408010 26260 100A 100mA 12 AUF3D410010 28115
300mA 12 AUF3C408030 26260 300mA 12 AUF3D410030 28115
30mA 12 AUF3C410003 27460 * For technical details, please contact nearest branch office
100A 100mA 12 AUF3C410010 28115
300mA 12 AUF3C410030 28115
Lauritz Knudsen, 01.05.2024 8
SPDs (Surge Protection Devices) [8536]

Range Highlights
› Conforms to IEC 61643-11
› Available in Type 2 and Type 1+2 800V Solar Application
› Type 2 : Protection against indirect M.R.P.
lightning and switching surges Voltage
Description Configuration Module Cat. No. (`)
(Uc)
» Maximum Discharge Current - Per Unit
Imax up to 70kA Type 2,
Iimp 12.5kA 3P 4 1500 AUSP023P40-1500 12500
› Type 1+2 : Protection against direct and
indirect lightning surges
Type 1+2,
» Maximum Discharge Current - 3P 5 1360 AUSP123P50-1360 41430
Iimp 12.5kA
Imax up to 100kA
Type 1+2,
Iimp 12.5kA 3P 4 880 AUSP123P50-880 30000

440V Application
Extend SPD life with
Spare Cartridges
Description Imax Configuration Module M.R.P. (`)
Cat. No.
Per Unit
Description M.R.P. (`)
1P+N 2 AUSP121PN50 10045 Cat. No.
Type 1+2, Per Unit
50kA
Iimp 12.5kA 3P+N 4 AUSP123PN50 19235
Cartridge for AUSP021PN15 AUSC021PN15 2515
1P+N 1 AUSP021PN40 6275
Type 2 40kA Cartridge for AUSP021PN40 AUSC021PN40 3135
3P+N 2 AUSP023PN40 12545
Cartridge for
1P+N 1 AUSP021PN15 5020 AUSC021PN70 3350
Type 2 15kA AUSP021PN70 / AUSP023PN70
3P+N 2 AUSP023PN15 9875 Cartridge for AUSP023PN15 AUSC023PN15 3290
Type 1+2, 1P+N 2 AUSP121PN100 9030 Cartridge for AUSP023PN40 AUSC023PN40 4185
100kA
Iimp 8kA 3P+N 4 AUSP123PN100 17740 Cartridge for
AUSC121PN100 5020
1P+N 2 AUSP021PN70 9855 AUSP121PN100 / AUSP123PN100
Type 2 70kA
3P+N 4 AUSP023PN70 16420 Cartridge for
AUSP121PN50 / AUSP123PN50 AUSC121PN50 5420

Changeover Switches (Automatic Changeover with Current Limiter, CO) [8536]

Single Phase ACCL Three Phase ACCL


Range Highlights Range Highlights
› Conforms to IEC 60947-6, IEC 60947-3 › Settable overload current limit at DG side
› Wide Range of Current Ratings › Separate power consumption monitoring for
» (Generator side) - 1A to 30A Mains & Genset
» (Electricity Board side) - 30A › Settable overvoltage & undervoltage protection
› RoHS compliant › Settable TPN or SPN mode at DG side
Description M.R.P. (`) › Protection against single phasing
Module CAT Nos.
EB/DG Per Unit
Description (AC-1) M.R.P. (`)
30A/1A 4 AUCL01030001 2410 Cat. No.
EB/DG Per Unit
30A/1.5A 4 AUCL010301E5 2410 32A / 32A AUCL03032032 10165
30A/2A 4 AUCL01030002 2410 40A / 32A AUCL03040032 10475
30A/2.5A 4 AUCL010302E5 2410 40A / 40A AUCL03040040 11340
30A/3A 4 AUCL01030003 2410 50A / 50A AUCL03050050 16155
30A/4A 4 AUCL01030004 2410 63A / 50A AUCL03063050 17830
30A/5A 4 AUCL01030005 2410 63A / 63A AUCL03063063 20195
30A/6A 4 AUCL01030006 2410 80A / 80A AUCL03080080 30780
30A/8A 4 AUCL01030008 2410 125A / 125A AUCL03125125 51815
30A/10A 4 AUCL01030010 2410
30A/12A 4 AUCL01030012 2410 For 3 Phase ACCL programming video
30A/15A 4 AUCL01030015 2410 please scan the QR code or click here

30A/20A 4 AUCL01030020 2410


30A/30A 4 AUCL01030030* 2410 Range Highlights
* Non-current limiting variant › Conforms to IEC 60947-3 and IS/IEC 60947-3
› Available in 3 positions (I-O-II) with centre off position
Changeover Switches › Utilization category AC-22A
Rating M.R.P. (`)
Module Cat. No. M.R.P. (`)
Per Unit Rating Module Cat. No.
Per Unit
Double Pole
Four Pole
25A 2 AUC00202500 1630
40A 4 AUC00404000 4290
40A 2 AUC00204000 2490
63A 6 AUC00406300 4865
63A 3 AUC00206300 2900

Lauritz Knudsen, 01.05.2024 9


Control & Monitoring Devices

Modular Contactors [8536]


Range Highlights
› Wide Range of Current Ratings: M.R.P. (`)
» 25A, 40A and 63A Description (AC-1) Module Cat. No.
Per Unit
› Conforms to : 25A-1NO 1 AUMC1002501 1810
» IEC 61095, EN 61095 25A-2NO 1 AUMC2002501 2265
» IEC 60947-4-1, EN 60947-4-1 40A-2NO 3 AUMC2004003 3880
» IEC 60947-5-1
40A-3NO 3 AUMC3004003 5560
› Protection Degree IP 20
40A-4NO 3 AUMC4004003 6525
63A-2NO+2NC 3 AUMC2206303 6895
63A-3NO 3 AUMC3006303 7065
63A-4NO 3 AUMC4006303 7780
Time Switches [9107]
Accessory [8538]
Auxiliary Contact, 2NO 0.5 AUMCAUX240 1740

Energy Meters [9030]


Range Highlights
› Communication with additional RS485
Description Module Cat. No.
M.R.P. (`) › Class 1 accuracy
Per Unit
Analog time switch 1 AUTS01ANA00* 4645
› Direct current operated meter
Analog time switch 3 AUTS03ANA00* 5650 › Reverse current indication for three-phase meter
Digital time switch 2 AUTS02DIG00* 3595
Description M.R.P. (`)
Astro time switch 2 AUTS02AST00* 6040 Module Cat. No.
Per Unit
Digital time switch 2 67DDT0* 2355 Single Phase - 60A 2 WD401010OOOO 2630
Astro time switch 2 T2DDT7* 4410 Three Phase - 80A 5 WD402010OOOO 5975
*Available till stocks last Single Phase - 60A (RS485) 2 WD401011OOOO 4200
Three Phase - 80A (Rs485) 5 WD402011OOOO 8605

Accessories

Accessories [8538]
All Half Module and One Module Indicating Lights [8531]
Accessories are common for
80A-125A MCBs, RCBOs and
Adi RCCBs

Description Configuration Module Voltage CAT Nos.


Auxiliary Contact 1NO+1NC 0.5 240V AC, 24V DC AUAXAC240 940
AUX/TAC* 1NO+1NC 0.5 240V AC, 24V DC AUATAC240 Description M.R.P. (`)
1105 Module Cat. No.
Per Unit
HR AUX/TAC* 1NO+1NC 0.5 240V AC, 24V DC AUATAC240HR 1105 RED 1 AUIL01RED00 1035
Undervoltage - 1 240V AC AUUVAC240 2225 YELLOW 1 AUIL01YEL00 1035
Release - 1 24V DC AUUVDC024 2225 BLUE 1 AUIL01BLU00 1035
Overvoltage Release - 1 240V AC AUOVAC240 2750 GREEN 1 AUIL01GRE00 1035
- 1 240V AC AUSRAC240 2550 RED-YELLOW-BLUE 1 AUIL01RYB00 1255
Shunt Release
- 1 24V DC AUSRDC024 2550
Suitable for 1Pole=1Mod devices: RCCBs,
Padlock-Suitable AUPD01 505
for Lock Hasp RCBOs, Changeover Switches up to 40A
3.5 - 5 mm dia. Suitable for 1Pole-1.5Mod devices:
max AUPD02 570
MCBs 80A-125A, Changeover Switch 63A

Note: Standard Pack Quantity for Padlock - 2 Nos.

Auxiliary & Accessories for Exora MCBs [8538]


Description Cat. No. M.R.P. (`) Per Unit
Auxiliary Contact - 6A , 240V AC, (1NO+1NC), 0.5 Mod BZA11006 885
Shunt Release - 240V AC, 1 Mod BZS00240 2425
Trip Alarm Contact - 6A, 240V AC, (1NO+1NC), 0.5 Mod BZT11006 1040

Lauritz Knudsen, 01.05.2024 10


EXORA DBs

Distribution Board suitable for


Aluminum shuttering (Mivan) Construction

To experience Scan or click

DBs suitable for Aluminum Shuttering Construction [8537]


SPN DBs TPN DBs
Highlights Highlights
› Available in CRCA sheet steel, RAL9003, powder coated › Available in CRCA sheet steel, RAL 9003, powder coated
› Ready to use DBs - Provided with 100A insulated phase bus-bar | › Ready to use DBs - Provided with 100A insulated phase bus-bars
neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement |neutral bar/s with shroud/s | earth bar/s | sticking saddles |
spill protector | color-coded interconnecting wire set | cable ties | cementspill protector | color-coded interconnecting wire set | cable
blanking plates and circuit identification label ties |blanking plates and circuit identification labels
› With provision for DP MCB/Isolator/RCCB/RCBO as incomer and SP › With provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP
MCBs as outgoings MCBs as outgoings

No. of Modules M.R.P. No. of Modules M.R.P.


Description Cat. Nos. (`) Description Cat. Nos. (`)
Incomer + Outgoing Per Unit Incomer + Outgoing Per Unit
IP 43 - Metal Door IP 43 - Metal Door

4 way 2 2 LTSD04M * 4 way 8 4+4+4 LTTD04M *


6 way 2 4 LTSD06M * 6 way 8 6+6+6 LTTD06M *
8 way 2 6 LTSD08M * 8 way 8 8+8+8 LTTD08M *
12 way 2 10 LTSD12M *
* For details, please contact nearest branch office
16 way 2 14 LTSD16M *
New SPN DB [8537] New TPN DB [8537]

Highlights Highlights
› Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 › Conforms to IS 8623-1 & 3, IEC 61439-1 & 3
› IK 08-for single door DBs, IK 09-for double door Dbs › IK 08-for single door DBs, IK 09-for double door Dbs
› Available in CRCA sheet steel, RAL9003, powder coated › Available in CRCA sheet steel, RAL 9003, powder coated
› Ready to use DBs - Provided with 100A insulated phase bus-bar | › Ready to use DBs - Provided with 100A insulated phase bus-bars |
neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement
spill protector | color-coded interconnecting wire set | cable ties | spill protector | color-coded interconnecting wire set | cable ties |
blanking plates and circuit identification label blanking plates and circuit identification labels
› With provision for DP MCB/Isolator/RCCB/RCBO as incomer and SP › With provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP
MCBs as outgoings MCBs as outgoings

No. of Modules M.R.P. No. of Modules M.R.P.


Description Cat. Nos. (`) Description Cat. Nos. (`)
Incomer + Outgoing Per Unit Incomer Outgoing Per Unit
IP 30 - Single Door IP 30 - Single Door

4 way 2 2 DESPN004SDS 1510 4 way 4 4+4+4 DETPE004SDS 3940

6 way 2 4 DESPN006SDS 1585 6 way 4 6+6+6 DETPE006SDS 4840

8 way 2 6 DESPN008SDS 1830 4 way 8 4+4+4 DETPN004SDS 4135

12 way 2 10 DESPN012SDS 2165 6 way 8 6+6+6 DETPN006SDS 5095

16 way 2 14 DESPN016SDS 2685 8 way 8 8+8+8 DETPN008SDS 6010

18 way 2 16 DESPN018SDS 3115 12 way 8 12+12+12 DETPN012SDS 8655

IP 43 - Metal Door 16 way 8 16+16+16 DETPN016SDS 10650

4 way 2 2 DESPN004DDS 1960 IP 43 - Metal Door

6 way 2 4 DESPN006DDS 2260 4 way 4 4+4+4 DETPE004DDS 4610

8 way 2 6 DESPN008DDS 2410 6 way 4 6+6+6 DETPE006DDS 5730

12 way 2 10 DESPN012DDS 2890 4 way 8 4+4+4 DETPN004DDS 4825

16 way 2 14 DESPN016DDS 3655 6 way 8 6+6+6 DETPN006DDS 6010

18 way 2 16 DESPN018DDS 3860 8 way 8 8+8+8 DETPN008DDS 7215

IP 43 - Glazed Door 12 way 8 12+12+12 DETPN012DDS 10760

4 way 2 2 DESPN004GDS 2625 16 way 8 16+16+16 DETPN016DDS 13350

6 way 2 4 DESPN006GDS 2795 IP 43 - Glazed Door


8 way 2 6 DESPN008GDS 3040 4 way 4 4+4+4 DETPE004GDS 6265

12 way 2 10 DESPN012GDS 3700 6 way 4 6+6+6 DETPE006GDS 7525

16 way 2 14 DESPN016GDS 4595 4 way 8 4+4+4 DETPN004GDS 6515

18 way 2 16 DESPN018GDS 4890 6 way 8 6+6+6 DETPN006GDS 7880

IP 54 - Metal Door 8 way 8 8+8+8 DETPN008GDS 9365

4 way 2 2 DESPN00454S 6910 12 way 8 12+12+12 DETPN012GDS 14365

6 way 2 4 DESPN00654S 7705 16 way 8 16+16+16 DETPN016GDS 17265

8 way 2 6 DESPN00854S 8195 IP 54 - Metal Door

12 way 2 10 DESPN01254S 9410 4 way 4 4+4+4 DETPE00454S 15645

16 way 2 14 DESPN01654S 10480 6 way 4 6+6+6 DETPE00654S 18285

18 way 2 16 DESPN01854S 10710 4 way 8 4+4+4 DETPN00454S 16615

6 way 8 6+6+6 DETPN00654S 20005

8 way 8 8+8+8 DETPN00854S 21870

12 way 8 12+12+12 DETPN01254S 30825

16 way 8 16+16+16 DETPN01654S 36995

For ordering old DBs, replace Cat no with “DB” instead of “DE”. Lauritz Knudsen, 01.05.2024 12
Eg. - New DB Cat no for SPN 12W DD - DESPN012DDS, Old DB Cat no for same will be DBSPN012DDS. Old DBs are available till stock last.
New PPI DB [8537] New TPN Phase Segregated DB [8537]

Highlights Highlights
› Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 › Conforms to IS 8623-1 & 3, IEC 61439-1 & 3
› IK 09-for double door DBs › IK 09-for double door DBs
› Available in CRCA sheet steel, RAL 9003, powder coated › Available in CRCA sheet steel, RAL 9003, powder coated
› Ready to use DBs - Provided with 100A insulated phase bus-bars | › Ready to use DBs - Provided with 100A insulated phase bus-bars |
neutral bar/s with shroud/s | earth bar/s | sticking saddles | neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement
cement spill protector | color-coded interconnecting wire set | spill protector | color-coded interconnecting wire set | cable ties |
cable ties | blanking plates and circuit identification labels blanking plates and circuit identification labels
› With provision for FP MCB / Isolator / RCCB / RCBO as incomer, › With provision for
DP RCCB/RCBO as sub-incomer and SP MCBs as outgoings » Modular Incomer - FP MCB/Isolator/RCCB/RCBO as incomer, DP
RCCB/RCBO as sub-incomer and SP MCBs as outgoings
» MCCB Incomer - MCCB* as incomer, DP RCCB/RCBO as sub-
incomer and SP MCBs as outgoings

Horizontal PPI DBs With Modular Incomer

IP 43 - Metal Door

No. of Modules M.R.P. No. of Modules M.R.P.


Description Cat. Nos. (`) Description Cat. Nos. (`)
Incomer Sub- Outgoing Incomer Sub- Outgoing
Incomer Per Unit Incomer Per Unit
IP 43 - Metal Door IP 43 - Metal Door

4 way 8 2+2+2 4+4+4 DEHPI004DD 8515 4 way 8 4+4+4 4+4+4 DEPSG004DD 12775

6 way 8 2+2+2 6+6+6 DEHPI006DD 10085 6 way 8 4+4+4 6+6+6 DEPSG006DD 14405

8 way 8 2+2+2 8+8+8 DEHPI008DD 12095 8 way 8 4+4+4 8+8+8 DEPSG008DD 16070
12 way 8 2+2+2 12+12+12 DEHPI012DD 16660 12 way 8 4+4+4 12+12+12 DEPSG012DD 19935
16 way 8 2+2+2 16+16+16 DEHPI016DD 19985

Tier PPI DBs With MCCB Incomer

No. of Modules M.R.P. No. of Modules M.R.P.


Description Cat. Nos. (`) Description Cat. Nos. (`)
Incomer Sub- Outgoing Incomer* Sub- Outgoing
Incomer Per Unit Incomer Per Unit
IP 43 - Metal Door IP 43 - Metal Door

6 way 8 2+2+2 6+6+6 DETPI006DD 10460 4 way MCCB 4+4+4 4+4+4 DEPGL004DD 17570

8 way 8 2+2+2 8+8+8 DETPI008DD 13115 6 way MCCB 4+4+4 6+6+6 DEPGL006DD 20095

10 way 8 2+2+2 10+10+10 DETPI010DD 13750 8 way MCCB 4+4+4 8+8+8 DEPGL008DD 23240

12 way 8 2+2+2 12+12+12 DETPI012DD 14565 12 way MCCB 4+4+4 12+12+12 DEPGL012DD 26210

16 way 8 2+2+2 16+16+16 DETPI016DD 16610 * Suitable for 3 Pole & 4 Pole DU100H, DU100D, DN0-100D &
DN0-100C MCCB as incomer
12 way MCCB* 2+2+2 12+12+12 DETPL012DD 15580

* Suitable for 3 Pole & 4 Pole DU100H, DU100D, DN0-100D &


DN0-100C MCCB as incomer

For ordering old DBs, replace Cat no with “DB” instead of “DE”.
Eg. - New DB Cat no for SPN 12W DD - DESPN012DDS, Old DB Cat no for same will be DBSPN012DDS. Old DBs are available till stock last. Lauritz Knudsen, 01.05.2024 13
New TPN Phase Selector DB [8537] New Flexi/Row DB [8537]

Highlights Highlights
› Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 › Conforms to IS 8623-1 & 3, IEC 61439-1 & 3
› IK 09-for double door Dbs › IK 09-for double door Dbs
› Available in CRCA sheet steel, RAL 9003, powder coated › Available in CRCA sheet steel, RAL 9003, powder coated
› Ready to use DBs - Provided with 3 nos. of 63A E&A rotary switches | › Ready to use DBs - neutral bar/s with shroud/s | earth bar/s | sticking
3 nos. of rocker switches for phase identification | 100A insulated saddles | cement spill protector | cable ties | circuit identification
phase bus-bars | neutral bar/s with shroud/s | earth bar/s | sticking labels
saddles | color-coded interconnecting wire set | cable ties | blanking › With provision to mount modular devices as per requirement
plates and circuit identification labels
› With provision for - FP MCB/Isolator/RCCB/RCBO as incomer and SP
MCBs as outgoings

No. of Modules M.R.P. M.R.P.


Description Description No. of Modules
Cat. Nos. (`) Cat. Nos. (`)
Incomer Outgoing Per Row
Per Unit Per Unit
IP 43 - Metal Door IP 43 - Metal Door

4 way 8 4+4+4 DEPSR004DD 15765 2 Row 28 Module 14 DEROW228DD 6225

6 way 8 6+6+6 DEPSR006DD 16015 3 Row 42 Module 14 DEROW342DD 7465

8 way 8 8+8+8 DEPSR008DD 17155 4 Row 56 Module 14 DEROW456DD 8115

10 way 8 10+10+10 DEPSR010DD 18330 4 Row 64 Module 16 DEROW464DD 9440

12 way 8 12+12+12 DEPSR012DD 19325

Vertical TPN DB with Modular Incomer [8537] Vertical TPN DB with MCCB Incomer [8537]

Highlights Highlights
› Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 › Conforms to IS 8623-1 & 3, IEC 61439-1 & 3
› IK 09-for double door Dbs › IK 09-for double door Dbs
› Available in CRCA sheet steel, RAL 9003, powder coated › Available in CRCA sheet steel, RAL 9003, powder coated
› Ready to use DBs - Provided with insulated vertical phase bus-bars | › Ready to use DBs - Provided with insulated vertical phase bus-bars |
neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement
spill protector | color-coded interconnecting wire set | cable ties | spill protector | color-coded interconnecting wire set | cable ties |
blanking plates and circuit identification labels blanking plates and circuit identification labels
› With provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/ › With provision for 3 pole and 4 Pole MCCB* as incomer and SP/TP
TP MCBs as outgoings MCBs as outgoings

Up to 125A MCCB Incomer

No. of Modules M.R.P.


M.R.P. Description Cat. Nos. (`)
No. of Modules
Description Cat. Nos. (`) Incomer* Outgoing Per Unit
Incomer Outgoing Per Unit
IP 43 - Metal Door
IP 43 - Metal Door
4 way MCCB 4+4+4 DEVTL004DD 14120
4 way 8 4+4+4 DEVTM004DD 11940
6 way MCCB 6+6+6 DEVTL006DD 16050
6 way 8 6+6+6 DEVTM006DD 13365
8 way MCCB 8+8+8 DEVTL008DD 17670
8 way 8 8+8+8 DEVTM008DD 15510
12 way MCCB 12+12+12 DEVTL012DD 24040
12 way 8 12+12+12 DEVTM012DD 21025
16 way MCCB 16+16+16 DEVTL016DD 28675
16 way 8 16+16+16 DEVTM016DD 24850
IP 54 - Metal Door
IP 54 - Metal Door
4 way MCCB 4+4+4 DEVTL00454 29250
4 way 8 4+4+4 DEVTM00454 25245
6 way MCCB 6+6+6 DEVTL00654 33355
6 way 8 6+6+6 DEVTM00654 27670
8 way MCCB 8+8+8 DEVTL00854 36110
8 way 8 8+8+8 DEVTM00854 30550
* Suitable for 3 Pole & 4 Pole DU100H, DU100D, DU125D, DU125H &
DN0 MCCB as incomer
For ordering old DBs, replace Cat no with “DB” instead of “DE”.
Eg. - New DB Cat no for SPN 12W DD - DESPN012DDS, Old DB Cat no for same will be DBSPN012DDS. Old DBs are available till stock last. Lauritz Knudsen, 01.05.2024 14
New Vertical TPN DB with MCCB Incomer [8537] New Plug & Socket DB [8537]

Up to 250A MCCB Incomer Highlights


› Conforms to IS 8623-1 & 3, IEC 61439-1 & 3
› Suitable for Surface and Flush mounting
› Available in CRCA sheet steel, RAL9003, powder coated
› Loose Metal Plugs & Sockets conforms to IS 8804; available in
Single Phase & Three Phase

No. of Modules M.R.P.


Description Cat. Nos. (`)
*
Incomer Outgoing Per Unit
IP 43 - Metal Door

4 way MCCB 4+4+4 DEVTH004DD 18180


Metal Plug & Socket Plastic Plug & Socket
6 way MCCB 6+6+6 DEVTH006DD 20360

8 way MCCB 8+8+8 DEVTH008DD 22390 M.R.P.


Description No. of
No. of Pins Cat. Nos. (`)
Modules
12 way MCCB 12+12+12 DEVTH012DD 27350 Per Unit

16 way MCCB 16+16+16 DEVTH016DD 36420 Metal Plug & Sockets

IP 54 - Metal Door 10 A, 2 Pin + SC^ P+N 1 DEMPS110SD 1925

4 way MCCB 4+4+4 DEVTH00454 33570 20 A, 2 Pin + SC^ P+N 1 DEMPS120SD 2070

6 way MCCB 6+6+6 DEVTH00654 36655 20 A, 2 Pin + SC^ P+N 2 DEMPS220SD 2245

8 way MCCB 8+8+8 DEVTH00854 37910 20 A, 3 Pin + SC^ 3P 3 DEMPS320SD 3805

* Suitable for 3 pole and 4 pole DU250, DU250C & DN1 MCCB as incomer 32 A, 3 Pin + SC^ 3P 3 DEMPS332SD 4500

32 A, 3 Pin + SC^ 3P 4 DEMPS432SD 4790

63 A, 5 Pin + SC^ 3P+N+E 4 DEMPS463SD 16225


Plastic Plug & Sockets
New Enclosure [8537]
16 A, 3 Pin P+N+E 2 DEPPS316SD 3150

Highlights 32 A, 3 Pin P+N+E 4 DEPPS332SD 3400


› Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 32 A, 5 Pin 3P+N+E 8 DEPPS532SD 5680
› Suitable for Surface and Flush mounting 63 A, 5 Pin 3P+N+E 8 DEPPS563SD 14220
› Available in CRCA sheet steel, RAL9003, powder coated
› With provision to mount MCB/Isolator/RCCB/RCBO and
other modular devices
Metal Plug [8536]

M.R.P.
Description No. of Pins Cat. Nos. (`)
IP 30 - Metal Door Per Unit
10 A, 2 Pin + SC^ P+N MPS210P 185

20 A, 2 Pin + SC^ P+N MPS220P 195

20 A, 3 Pin + SC^ 3P MPS320P 255

M.R.P. 32 A, 3 Pin + SC^ 3P MPS332P 490


Description No. of Modules Cat. Nos. (`)
Note: Standard pack quantity - 20 nos.
Per Unit
IP 30 - Metal Door

2 way 2 DEENC002SD 775

3 way 3 DEENC003SD 775 Metal Socket [8536]


4 way 4 DEENC004SD 775

6 way 6 DEENC006SD 1180 M.R.P.


Description No. of Pins Cat. Nos. (`)
Per Unit
10 A, 2 Pin + SC^ P+N MPS210S 190

20 A, 2 Pin + SC^ P+N MPS220S 210

20 A, 3 Pin + SC^ 3P MPS320S 290

32 A, 3 Pin + SC^ 3P MPS332S 490

^ SC-Scraping Earth
Note: Standard pack quantity - 20 nos.

For ordering old DBs, replace Cat no with “DB” instead of “DE”.
Eg. - New DB Cat no for SPN 12W DD - DESPN012DDS, Old DB Cat no for same will be DBSPN012DDS. Old DBs are available till stock last. Lauritz Knudsen, 01.05.2024 15
New Dbs with provision for TV / Telephone splitters [8537]

Highlights
› Distribution Boards equipped with provisions to mount TV / Telephone
splitters
› Available in SPN & TPN Dbs
No. of Modules M.R.P.
DB Type Description Cat. Nos. (`)
Incomer + Outgoing Per Unit
IP 43 - Metal Door

6 way 2 4 DESPN006DDTV 4295

8 way 2 6 DESPN008DDTV 4615

SPN 12 way 2 10 DESPN012DDTV 5680

16 way 2 14 DESPN016DDTV 6585

18 way 2 16 DESPN018DDTV 7790

4 way 8 4+4+4 DETPN004DDTV 8440

TPN 6 way 8 6+6+6 DETPN006DDTV 9745

8 way 8 8+8+8 DETPN008DDTV 11620


Cable End Boxes [8537]

Highlights DB Accessories
› Available in CRCA sheet steel, RAL9003,
powder coated
› Can be either at the top or bottom of the Busbar - Fork Type [8538]
distribution board
Highlights
Description M.R.P. (`) › Available in Single Pole, Double
Cat. Nos.
Per Unit Pole, Three Pole and Four Pole
CEB for SPN DBs versions
› Material : Copper
CEB-SPN Double Door, 4 way DESPN004CBS 845

CEB-SPN Double Door, 6 way DESPN006CBS 905


Description Cat. Nos.. M.R.P. (`) Std. Pack
CEB-SPN Double Door, 8 way DESPN008CBS 1015 Per Unit Qty.

CEB-SPN Double Door, 12 way DESPN012CBS 1130 SP 13 Mod BSP13 375 5


CEB-SPN Double Door, 16 way DESPN016CBS 1590 SP 56 Mod BSP56 1540 5
CEB-SPN Double Door, 18 way DESPN018CBS 1645 DP 12 Mod BDP12 670 5
CEB for TPN DBs TP 12 Mod BTP12 720 5
CEB-TPE Double Door, 4 way DETPE004CBS 1090 FP 12 Mod BFP12 1430 5
CEB-TPE Double Door, 6 way DETPE006CBS 1550 End Caps for SP ECP01 25 10
CEB-TPN Double Door, 4 way DETPN004CBS 1140 End Caps for DP/TP ECP03 50 10
CEB-TPN Double Door, 6 way DETPN006CBS 1600 End Caps for FP ECP04 85 10
CEB-TPN Double Door, 8 way DETPN008CBS 2015

CEB-TPN Double Door, 12 way DETPN012CBS 3345

CEB-TPN Double Door, 16 way DETPN016CBS 3375


Blanking Plates [8538]
Highlights
CEB for Horizontal PPI DBs
› Available in One module and Half module
CEB-Horz. PPI Double Door, 4 way DEHPI004CB 1690

CEB-Horz. PPI Double Door, 6 way DEHPI006CB 2105

CEB-Horz. PPI Double Door, 8 way DEHPI008CB 2645


Description M.R.P. (`) Std.Pack
Cat. Nos.
CEB-Horz. PPI Double Door, 12 way DEHPI012CB 3315 Per Unit Qty.

CEB-Horz. PPI Double Door, 16 way DEHPI016CB 3605 One Module BKP10 25 10
CEB for VTPN DBs Half Module BKP05 25 10
CEB-VTPN Double Door,
Modular Incomer DEVTMXXXCB 1130
Padlock [8301]
CEB-VTPN Double Door,
MCCB Incomer DEVTXXXXCB 3985
Highlights
CEB for Phase Segregated DBs › Version with standard lock and a common
PDK02 key
CEB-PSG Double Door, 4 way DEPSG004CB 2955

CEB-PSG Double Door, 6 way DEPSG006CB 3525 M.R.P. Std.


Description Cat. Nos. (`) Pack
CEB-PSG Double Door, 8 way DEPSG008CB 3895 Per Unit Qty.
CEB-PSG Double Door, 12 way DEPSG012CB 4335 Lock and Key Kit PDK02 655 5

For ordering old DBs, replace Cat no with “DB” instead of “DE”.
Eg. - New DB Cat no for SPN 12W DD - DESPN012DDS, Old DB Cat no for same will be DBSPN012DDS. Old DBs are available till stock last. Lauritz Knudsen, 01.05.2024 16
New Industrial Plugs & Sockets [8536]

Plugs Socket
Highlights Highlights
› Conforms to IEC 60309 -1&2 › Conforms to IEC 60309 -1&2
› Mechanical Impact - IK08 › Mechanical Impact - IK08
› Ingress Protection - IP44 & IP67 › Ingress Protection - IP44 & IP67
› Fire Resistance - 850oC as per IEC 60695-2-11 › Fire Resistance - 850oC as per IEC 60695-2-11
› Easy Screw connection with same orientation › Easy Screw connection with same orientation
of clamp screws of clamp screws

M.R.P.
Description Cat NO (`) M.R.P.
Description Cat NO (`)
Per Unit
Per Unit
Plug - IP44
Socket - IP44
16A, 2P+E PSKPM30164 590
16A, 2P+E PSKSM30164 820
32A, 2P+E PSKPM30324 930
32A, 2P+E PSKSM30324 1125
16A, 3P+E PSKPM40164 745
16A, 3P+E PSKSM40164 945
32A, 3P+E PSKPM40324 1080
16A, 3P + N + E PSKSM50164 1030
16A, 3P+N+E PSKPM50164 780
32A, 3P + N + E PSKSM50324 1375
32A, 3P+N+E PSKPM50324 1065
Socket - IP67
Plug - IP67
16A, 2P+E PSKSM30167 1515
16A, 2P + E PSKPM30167 1290
32A, 2P+E PSKSM30327 2080
32A, 2P + E PSKPM30327 1825
63A, 2P+E PSKSM30637 5635
63A, 2P + E PSKPM30637 5175
16A, 3P+E PSKSM40167 1900
16A, 3P + E PSKPM40167 1455
63A, 3P+E PSKSM40637 5685
32A, 3P + E PSKPM40327 2305
16A, 3P + N + E PSKSM50167 1985
63A, 3P + E PSKPM40637 4930
32A, 3P + N + E PSKSM50327 2325
16A, 3P + N + F PSKPM50167 1560
63A, 3P + N + E PSKSM50637 5775
32A, 3P + N + E PSKPM50327 1985
125A, 3P + N + E PSKSM51257 18135
63A, 3P + N + E PSKPM50637 4940

125A, 3P + N + E PSKPM51257 15085

Socket Angled Socket Straight


Highlights Highlights
› Conforms to IEC 60309 -1&2 › Conforms to IEC 60309 -1&2
› Mechanical Impact - IK08 › Mechanical Impact - IK08
› Ingress Protection - IP44 & IP67 › Ingress Protection - IP44 & IP67
› Fire Resistance - 850oC as per IEC 60695-2-11 › Fire Resistance - 850oC as per IEC 60695-2-11
› Easy Screw connection with same orientation › Easy Screw connection with same orientation
of clamp screws of clamp screws

M.R.P. M.R.P.
Description Cat NO (`) Description Cat NO (`)
Per Unit Per Unit
Socket Angled - IP44 Socket Straight- IP44

16A, 2P+E PSKSA30164 635 16A, 2P+E PSKSS30164 715

32A, 2P+E PSKSA30324 1125 32A, 2P+E PSKSS30324 1135

16A, 3P+E PSKSA40164 945 32A, 3P+N+E PSKSS50324 1420

32A, 3P+E PSKSA40324 1305 Socket Straight- IP67


16A, 3P+N+E PSKSA50164 1005 16A, 2P+E PSKSS30167 1200
32A, 3P+N+E PSKSA50324 1300 63A, 2P+E PSKSS30637 6155
Socket Angled - IP67 63A, 3P+E PSKSS40637 5145

16A, 2P+E PSKSA30167 1190 63A, 3P+N+E PSKSS50637 5145

32A, 2P+E PSKSA30327 1550 125A, 3P+N+E PSKSS51257 17245

63A, 2P+E PSKSA30637 5085

32A, 3P+E PSKSA40327 2305

63A, 3P+E PSKSA40637 5095

32A, 3P+N+E PSKSA50327 1840

63A, 3P+N+E PSKSA50637 5195

125A, 3P+N+E PSKSA51257 17245 Lauritz Knudsen, 01.05.2024 17


General All prices are on Maximum retail price basis inclusive of
all duties, GST & any other tax as applicable.
Terms

All products listed in the price list are covered by a warranty


against manufacturing defects for a period of 18* months from
the date of purchase. For Lauritz Knudsen MCBs & Isolators
mounted inside Lauritz Knudsen Distribution Boards, an extended
warranty of 5 years is provided.
Warranty In the event of a defect due to faulty workmanship or other
associated reasons, we will, at our discretion, remedy the defect
Policy or replace the faulty parts or the entire product as soon as
possible, free of cost.
However, the warranty is subject to proper usage, efficient
maintenance, and does not cover defects arising from fire,
accidents, inefficient maintenance, faulty operation, or deliberate
or accidental damage. It also does not cover damage to power
electronic components such as thyristors & IGBTs, which
primarily fail due to overtemperature & over-voltage. Users need
to take adequate precautions to eliminate these conditions.
Manufacturer shall not be responsible & liable for any special,
incidental, social or consequential (including lost profits) loss,
consequential damages, injury or damages (punitive) of any
kind solely attributable to defect or failure of its products.
Manufacturer shall not be liable in any manner for the issue of
or failure in the performance of other equipment the product is
attached to.
Note: We are committed to maintaining our product warranty in
line with our standard terms for both the Lauritz Knudsen Brand
and the L&T Switchgear brand. The change in brand will not alter
our standard warranty terms or any applicable extended warranty
terms.
Furthermore, we will ensure that spares and after-sales support
remain available throughout the entire product life cycle,
regardless of whether the products are under the L&T Switchgear
brand or the Lauritz Knudsen Brand

Lauritz Knudsen Electrical & Automation has over seven decades


of experience in providing after sales service for low voltage
distribution system in every type of industry & commercial
complex in India

Comprehensive Lauritz Knudsen Electrical & Automation offers the following


services, partnering you in your maintenance of low voltage
Service Support distribution products:
› Regular Maintenance
› Preventive Maintenance Programme
› On Call
› Annual Maintenance Contract
› Product Support for Managing Obsolescence-

Please visit www.LK-EA.com for latest update on our products & prices.
Switchgear Training Centres

Pune Lucknow Delhi


Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation
Switchgear Training Centre Switchgear Training Centre Switchgear Training Centre
T-156 / 157, MIDC, C-6 & 7, UPSIDC, A-25, Imperia Complex, First Floor
Bhosari, Pune - 411 026 P. O. Sarojininagar, Mohan Cooperative Industrial Estate
Tel: 020-2712 0037 / 2712 0653 Lucknow - 226 008 Near Sarita Vihar / Mohan Estate Metro Station
E-mail: [email protected] Tel: 97944 54455 Main Mathura Road, New Delhi - 110044
E-mail: [email protected] Tel: 9899020306 / 9720186726 / 9560845094
E-mail: [email protected]

Kolkata Vadodara Coonor


Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation
Switchgear Training Centre, Switchgear Training Centre Switchgear Training Centre
2nd Floor, Block BN3, Sector V, Behind L&T Knowledge City, Ooty-Coonoor Main Road
Salt Lake City, Near Village Ankhol, Yellanahalli P.O.,
Kolkata - 700091, West Bengal Vadodara - 390019 The Nilgiris - 643 243
Tel: 7738717893 / 7797795567 Tel: 0265 6147805 / 6147808 Tel: 0423 251 7107
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]

Customer Interaction Center (CIC)


Phone no: 022 6932 7800
Web: www.LK-EA.com | e-mail: [email protected]
General All prices are on Maximum retail price basis inclusive of
all duties, GST & any other tax as applicable.
Terms

All products listed in the price list are covered by a warranty


against manufacturing defects for a period of 18* months from
the date of purchase. For Lauritz Knudsen MCBs & Isolators
mounted inside Lauritz Knudsen Distribution Boards, an extended
warranty of 5 years is provided.
Warranty In the event of a defect due to faulty workmanship or other
associated reasons, we will, at our discretion, remedy the defect
Policy or replace the faulty parts or the entire product as soon as
possible, free of cost.
However, the warranty is subject to proper usage, efficient
maintenance, and does not cover defects arising from fire,
accidents, inefficient maintenance, faulty operation, or deliberate
or accidental damage. It also does not cover damage to power
electronic components such as thyristors & IGBTs, which
primarily fail due to overtemperature & over-voltage. Users need
to take adequate precautions to eliminate these conditions.
Manufacturer shall not be responsible & liable for any special,
incidental, social or consequential (including lost profits) loss,
consequential damages, injury or damages (punitive) of any
kind solely attributable to defect or failure of its products.
Manufacturer shall not be liable in any manner for the issue of
or failure in the performance of other equipment the product is
attached to.
Note: We are committed to maintaining our product warranty in
line with our standard terms for both the Lauritz Knudsen Brand
and the L&T Switchgear brand. The change in brand will not alter
our standard warranty terms or any applicable extended warranty
terms.
Furthermore, we will ensure that spares and after-sales support
remain available throughout the entire product life cycle,
regardless of whether the products are under the L&T Switchgear
brand or the Lauritz Knudsen Brand

Lauritz Knudsen Electrical & Automation has over seven decades


of experience in providing after sales service for low voltage
distribution system in every type of industry & commercial
complex in India

Comprehensive Lauritz Knudsen Electrical & Automation offers the following


services, partnering you in your maintenance of low voltage
Service Support distribution products:
› Regular Maintenance
› Preventive Maintenance Programme
› On Call
› Annual Maintenance Contract
› Product Support for Managing Obsolescence-

Please visit www.LK-EA.com for latest update on our products & prices.
Electrical Standard
Products (ESP) Offices
HEAD OFFICE

Lauritz Knudsen Electrical & Automation, A/600, Shil-Mahape Road, TTC Industrial Area, MIDC Thane,Navi Mumbai, 400 710, Maharashtra.
Tel: 022-6722 6300 | Fax: 022-6705 1112 | e-mail: [email protected]

BRANCH OFFICES

Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation
C-201, The First Commercial Complex, Ground Floor, B-27, Biplab Rashbihari Sarani, Business Communication Centre A-25, 1st Floor, Imperia Complex,
B/S Keshavbaug Party Plot, Vastrapur, Sector 2A, Bidhan Nagar, 2nd Floor, Chiramel Chambers, Mohan Corporative Industrial Estate,
Ahmedabad - 380 015 Durgapur - 713 212 Kurisupally Road, Ravipuram, Near Sarita Vihar Metro Station,
Phone No: 022-6932 7800 Phone No: 022-6932 7800 Kochi - 682 015 Mathura Road,
e-mail: [email protected] e-mail: [email protected] Phone No: 022-6932 7800 New Delhi -110 044
e-mail: [email protected] Phone no: 022-6932 7800
e-mail: [email protected]

Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation
Wework Central, #36 Infantry Road, 6th Floor, Exotica Greens, A Block, 191, 2nd Floor, BN3, Salt Lake, Sector-V, A06/A07, Second Floor,
Bengaluru - 560 001 R G Baruah Road, Guwahati Central, Kolkata - 700 091 Grand Chandra Complex, Frazer Road
Phone No: 022-6932 7800 Guwahati - 781 005 Phone No: 022-6932 7800 Patna - 800 001
e-mail: [email protected] Phone No: 022-6932 7800 e-mail: [email protected] Phone No: 022-6932 7800
e-mail: [email protected] e-mail: [email protected]

Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation
Under O Launchpad, 4th Floor, Shri Daneshwari, 1st Floor, No.10, Fortuna Towers, 2nd Floor, UrbanWrk, 5th Floor, Sai Radhe,
Unit-434, Esplanade 1, Rasulgarh, Plot No. 17, 2nd Cross, Near Old Income Rana Pratap Marg, Near NBRI Raja Bahadur Mill Road, Behind Hotel
Bhubaneswar - 751 010 Tax Office Road, Vidyanagar, Lucknow - 226 001 Grand Sheraton, Sangamwadi
Phone No: 022-6932 7800 Hubballi - 580 021 Phone No: 022-6932 7800 Pune - 411 001
e-mail: [email protected] Phone No: 022-6932 7800 e-mail: [email protected] Phone No: 022-6932 7800
e-mail: [email protected] e-mail: [email protected]

Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation
4th Floor, SCO-54, 55 ,56, Sector-17A AWFIS Space Solutions, Prestige Phoenix, El Dorado Building, 3rd Floor, 6, Office No. 211 & 212, Pithalia Plaza,
Chandigarh - 160 017 4th floor, 1405, Umanagar, Begumpet, Venkatraman Street, Chinna Chokkikulam KK Road, Near Fafadih Chowk,
Phone No: 022-6932 7800 Hyderabad - 500 016 Madurai - 625 002 Raipur - 492 001, Chhattisgarh,
e-mail: [email protected] Phone No: 022-6932 7800 Phone No: 022-6932 7800 Phone No: 022-6932 7800
e-mail: [email protected] e-mail: [email protected] e-mail: [email protected]

Lauritz Knudsen Electrical & Automation, Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation
801 Word Level-8, No. 28, Workie, 214 - 2nd Floor, TC II, Tower B, PRIMA BAY Gate No. 5, 10th Floor, Titaanium Business,
SIDCO Industrial Estate, Guindy, Apollo Premier, PU-4, Saki Vihar Road Powai, Bhimrad Road, Althan
Chennai - 600 032, Tamil Nadu, Scheme No. 54, Vijay Nagar Square, Mumbai - 400 072 Surat - 395 017
Phone No: 022-6932 7800 Indore - 452 010 Phone No: 022-6932 7800 Phone No: 022-6932 7800
e-mail: [email protected] Phone No: 022-6932 7800 e-mail: [email protected] e-mail: [email protected]
e-mail: [email protected]

Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation
Playworkz Coworking Space Office No. 430, 4th Floor, Unnati Building, 2nd Floor, 11th Floor, Block-D, Notus IT Park,
43 & 44, 3rd Cross, Jaipur Electronic Market, Riddhi Siddhi, Automation Campus, A-600, TTC Industrial Sarabhai Campus, Bhailal Amin Marg,
Bharathy Colony, Peelamedu, Gopalpura Bypass, Area Shil-Mahape Road, Mahape Vadodara - 390 023
Coimbatore - 641 004 Jaipur - 302 018 Navi Mumbai - 400 710 Phone No: 022-6932 7800
Phone No: 022-6932 7800 Phone No: 022-6932 7800 Phone No: 022-6932 7800 e-mail: [email protected]
e-mail: [email protected] e-mail: [email protected] e-mail: [email protected]

Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation Lauritz Knudsen Electrical & Automation
3rd Floor, 1&2 Vijay Park, GDR Siddha, Ground Floor, N Road M1 & M2, Mezzanine Floor, Naga Chambers, 3rd Floor, D/No. 12-1-16,
Main Chakrata Road, Opp. Anandam, Bistupur, Opposite St. Mary's Church, Himalaya Excellency, Plot No. 49, Survey No. 1051, Waltair Main Road,
Near Ballupur chowk, Jamshedpur - 831 001 Plot No. C-47, Pratap Nagar Square, Visakhapatnam - 530 002, Andhra Pradesh,
Dehradun - 248 001 Phone No: 022-6932 7800 Nagpur - 440 022 Phone No: 022-6932 7800
Phone No: 022-6932 7800 e-mail: [email protected] Phone No: 022-6932 7800 e-mail: [email protected]
e-mail: [email protected] e-mail: [email protected]

Product improvement is a continuous process. For the latest information and special application,
please contact any of our offices listed here. Product photographs shown for representative purpose only.

Lauritz Knudsen Electrical & Automation, Electrical Standard Product


A/600, Shil-Mahape Road, TTC Industrial Area, MIDC Thane, Navi Mumbai, 400 710,
Maharashtra, Phone No: 022-6722 6300 | Web: www.LK-EA.com

Customer Interaction Center (CIC)


Phone no: 022-6932 7800
Web: www.LK-EA.com | e-mail: [email protected]

You might also like