V1.

45 as from April 2004 Aquilion16_Software_Specifics_PC, 2 April 2004


For the PC based systems

Software
• Specifics

© Toshiba Medical Systems Corporation 2004 1


Specifics
• Structure
• Features

© Toshiba Medical Systems Corporation 2004 2


Structure
Application CD 2

Program
Windows API
CT applications

Exceed

MKS Toolkit

Windows 2000

BASE System CD 1
Drivers included in BASE System

© Toshiba Medical Systems Corporation 2004 3


Mortice Kern Systems - MKS

Structure
• Windows 2000 Professional Service Pack 4
• MKS Toolkit
UNIX emulation function - “Nutcracker”
Telnet
FTP
• Hummingbird Exceed
Handling of interactive windows and image display

• CT Applications
CT control program
File management program
Three-dimensional image generation program
• Windows API
Application Programming Interface
allows the program to talk to the operating system
© Toshiba Medical Systems Corporation 2004 4
Structure - Partitions
A Floppy Disk Diskette - Option Licence
C LocalDisk Operating system
D Runtime MKS Tool - Exceed - Drivers
E Image Image data - Raw data directory*
F IAPSWAP 3D application work area
G Spool Temporary files - cleared at power off
H Pagefile “Swap” area for Windows*
O Compact Disk CD Rewrite-able - Master software
P Removable Disk Only D-console - MOD
S Service Service work area - InnerVision - 1.2GB
V Virtual CD - VCD Archive to CD-R - Both consoles
DICOM Media Option for Anet only - V1.40
X Root CT application

System disk 80GB - ATA/IDE


*E and H on Image disk 73GB - SCSI
© Toshiba Medical Systems Corporation 2004 5
Structure - Partitions

© Toshiba Medical Systems Corporation 2004 6


Features
• Single click software - V2.0 series feature
• V1.45 for Aquilion16 PC based on V1.41 for Asteion Super4
• Channel replacement program - calibration may be required
• Measurement of focus program does not work - no meaning!
• X-ray tube front-back alignment:
Registration by quitting the program if calculated value within tolerance -
Value is not used by software - not backed up either
• DCA proper wedge selection

© Toshiba Medical Systems Corporation 2004 7


Calibration - V1.45 for Aquilion16 PC based

• Similar to Aquilion16
• NRA acquisition includes Air data for 0.75s only
Separate Air data acquisition is necessary - select ALL
• Counter is shown - space for 400
• Delete button - individual stages deletion

[x:/] cd /ct/KBProj/develop/bin/multi/tools/
CalBackupToHDD for backup to CALIB on E:
CalBackupToHDD G:/CALIB/ for backup to CALIB on G:
Not enough space! example only

© Toshiba Medical Systems Corporation 2004 8


Calibrations
• Long waiting times upon starting
calibrations

Automatic air calibration


• Scheduling possible for each day
of the week
• User-friendly interface

© Toshiba Medical Systems Corporation 2004 9


Special Configuration

Password to edit exam-plans


Default is OFF
Not supported for Aquilion16!

For one-PC systems only - Asteion Super4

Not supported for Aquilion16!

© Toshiba Medical Systems Corporation 2004 10


EPpreset password Op...
• Initial: password
Can be changed by the operator
• Master password: Kingbird
Always access with Kingbird
• In case of user memory problems:
Kingbird can set new user password

© Toshiba Medical Systems Corporation 2004 11