VNX5300 Parts Location Guide
VNX5300 Parts Location Guide
VNX5300™
This guide describes one of five models available in the VNX Series, the EMC®
VNX5300™. This guide is a parts location guide and provides illustrations of the part
number label locations of orderable parts for the EMC VNX5300 platform. Included in this
parts location guide are also tables describing the individual VNX5300 parts or
components and how these components are identified as either customer replaceable
units (CRUs) or field replaceable units (FRUs).
Topics include:
◆ VNX5300 Block and File platform stackup ................................................................. 4
◆ VNX5300 components .............................................................................................. 7
◆ Standby power supply (SPS) ..................................................................................... 7
◆ Disk processor enclosure (DPE) ................................................................................. 8
◆ SP power supply/cooling module ............................................................................ 12
◆ SP........................................................................................................................... 13
◆ Control Station........................................................................................................ 15
◆ Data Mover enclosure ............................................................................................. 16
◆ Data Mover Power supply/cooling fan module......................................................... 17
◆ Data Mover CPU module.......................................................................................... 18
◆ Management module .............................................................................................. 21
◆ I/O modules............................................................................................................ 21
◆ Small form-factor pluggable (SFP) ........................................................................... 32
◆ DIMMs .................................................................................................................... 35
◆ Disk-array enclosure (DAE) ...................................................................................... 39
Product software and hardware release revisions
IMPORTANT
The part numbers listed in this guide are for reference only. Part numbers can change over
time, and this document does not keep pace with those changes. The EMC parts inventory
system will automatically substitute for the latest part numbers as required.
Contact your EMC representative if a product does not function properly or does not
function as described in this document.
Note: This document was accurate at publication time. New versions of this document
might be released on the EMC online support website. Check the EMC online support
website to ensure that you are using the latest version of this document.
Revision history
The following table presents the revision history of this document:
Technical support — For technical support, go to EMC online support and select Support.
On the Support page, you will see several options, including one to create a service
request. Note that to open a service request, you must have a valid support agreement.
Contact your EMC sales representative for details about obtaining a valid support
agreement or with questions about your account.
Title Description
“VNX5300 Block and File Describes and shows the front and rear views of a typical
platform stackup” on page 4 VNX5300.
“Standby power supply (SPS)” Describes and illustrates the part number label locations of the
on page 7 SPS.
“Disk processor enclosure Describes and illustrates the part number label locations of the
(DPE)” on page 8 DPE and the components that comprise the DPE.
“Control Station” on page 15 Describes and illustrates the part number label locations of the
CS.
“Data Mover enclosure” on Describes and illustrates the part number label locations of the
page 16 DME and the management module.
“I/O modules” on page 21 Describes and illustrates the part number label locations of the
I/O modules that comprise the DPE and the DME.
“Small form-factor pluggable Describes and illustrates the part number label locations of the
(SFP)” on page 32 SFP transceiver modules used in the DME.
“DIMMs” on page 35 Describes and illustrates the part number label locations of the
memory module or dual-inline memory modules (DIMMs) used
in the DPE and the DME.
“Disk-array enclosure (DAE)” on Describes and illustrates the part number label locations of the
page 39 two types of DAEs available for the VNX5300.
Related documentation
EMC provides the ability to create step-by-step planning, installation, and maintenance
instructions tailored to your environment. To create VNX customized documentation, go
to: https://mydocs.emc.com/VNX/.
◆ For server-related tasks, go to the Server tasks for the VNX5300, VNX5500, VNX5700,
and VNX7500 section, and then select the appropriate heading. For example, to
download a PDF copy of Adding or replacing hardware, go to Add or replace hardware
and follow the steps in the wizard.
Note: Throughout this guide, figure references are placed in the Part number label location
heading of tables because some of the tables have part number locations, as described in
Table 4 on page 11 and some do not, as described in Table 1 on page 8, for example. This
format is used throughout this guide.
Front view
On the front, viewing from top to bottom, a Block and File VNX5300 platform includes the
following hardware:
◆ One 2U Data Mover enclosure with one to two Data Movers
◆ One to two 1U Control Stations
◆ One 3U DPE chassis with either a:
• 15 (3.5-inch) disk drives (hot-swappable)
or,
• 25 (2.5-inch) disk drives (hot-swappable)
◆ One dual 1U standby power supply (SPS)
Figure 1 shows an example of the front of a Block and File VNX5300 platform with a 3U, 15
(3.5-inch) DPE.
AC AC AC AC
Data Mover
Enclosure 0
DVD
Control Station 1
(optional)
DVD
Control Station 0
3U, 15 (3.5-inch)
disk processor
enclosure (DPE)
SPS
VNX-000562
Figure 1 Example of the Block and File VNX5300 platform with a 3U, 15 (3.5-inch) DPE (front view)
Figure 2 shows an example of the front of a Block and File VNX5300 platform with a 3U, 25
(2.5-inch) DPE.
AC AC AC AC
Data Mover
enclosure 0
DVD
Control Station 1
(optional)
DVD
Control Station 0
0 24
3U, 25 (2.5-inch)
disk processor
enclosure (DPE)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
SPS
VNX-000612
Figure 2 Example of the Block and File VNX5300 platform with a 3U, 25 (2.5-inch) DPE (front view)
Note: A Block and File VNX5300 platform has one 2U Data Mover enclosure, one 1U
Control Station, one 3U DPE, and one dual 1U SPS. In the following sections, the
illustrations and corresponding tables describe these individual components. These
descriptions are for illustrative purposes only.
Rear view
On the rear, viewing from top to bottom, a Block and File VNX5300 platform includes the
following hardware components:
◆ One 2U Data Mover enclosure with two Data Movers
◆ One to two 1U Control Stations
◆ One 3U DPE with two storage processors (SP A and B); each SP has one CPU module
and one power supply/cooling module
◆ One dual 1U SPS
Figure 3 shows an example of the rear of a Block and File VNX5300 platform.
3
3
3
3
3
3
3
3
2 Data Mover
2
2
2
2
2
2
2
Enclosure 0
1
1
1
1
1
0
0
0
0
CS B MGMT
Control Station 1
A
(optional)
CS B MGMT
Control Station 0
A
3
3
2
2
2
2
Disk
1
1
1
1
B A processor
0
0
0
0
2 3 4 5
8Gb 6Gb
fibre SAS 1 X4
2 3 4 5
8Gb 6Gb
fibre SAS 1 X4 enclosure
SPS
VNX-000563
VNX5300 components
Viewing from the bottom to the top, the Block and File VNX5300 platform includes several
components. The following sections discuss each component in an illustration and table.
The illustration will show or point out the location of the part number label on the
component. The table will list the part number, describe the component or part, and tell
you if it is a FRU or CRU or both.
◆ Dual 1U standby power supply (SPS)
◆ 3U Disk processor enclosure (DPE)
• 3U, 15 (3.5-inch) disk drive
• 3U, 25 (2.5-inch) disk drive
• Storage processor (SP) power supply/cooling module
• Storage processor
◆ 1U Control Station (CS)
◆ 2U Data Mover enclosure (DME)
• DME power supply/cooling module
• DME CPU module
• Management module
◆ I/O modules
• SP I/O modules
• DME I/O modules
◆ Small form-factor pluggable (SFP) transceiver modules
◆ Dual in-line memory modules (DIMMs)
• SP DIMMs
• DME DIMMs
◆ 2U or 3U Disk-array enclosures (DAEs)
• 3U, 15 (3.5-inch) disk drive
• 2U, 25 (2.5-inch) disk drive
S/N S/N
900-XXX-0014 0082 900-XXX-0014 0082
Table 5 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Front view
The 3U DPE supports two types of disk drive carriers:
◆ 3U, 15 (3.5-inch) disk drives
◆ 3U, 25 (2.5-inch) disk drives
Note: You can visually distinguish disk module kinds by their type, capacity, and speed
labels, and by the design of the latch and handle on each disk module (Figure 5 on
page 9).
VNX-000607
Figure 5 Example of the DPE 3U, 15 (3.5-inch) disk drive (front view)
Note: Figure 5 is for illustrative purposes only. The front of the disk modules may be a little
different than the ones in your particular cabinet.
Table 2 is an example of the parts available for the 3U, 15 (3.5-inch) DPE and lists the part
number label location, part number, description, and whether it is a FRU or CRU.
IMPORTANT
Due to the extensive variety of disk module types, Table 2 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.
Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).
Note: You can visually distinguish disk module kinds by their type, capacity, and speed
labels, and by the design of the latch and handle on each disk module (Figure 6).
0 24
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
VNX-000603
Figure 6 Example of the DPE 3U, 25 (2.5-inch) disk drive (front view)
Note: Figure 6 is for illustrative purposes only. The front of the disk modules may be a little
different than the ones in your particular cabinet.
Table 3 is an example of the parts available for the 3U, 25 (2.5-inch) DPE and lists the part
number label location, part number, description, and whether it is a FRU or CRU.
IMPORTANT
Due to the extensive variety of disk module types, Table 3 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.
Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).
Rear view
Figure 7 shows the rear view of the 3U disk processor enclosure (DPE) with two storage
processors (SP A and B).
1 2 3 4
3
3
3
3
2
2
2
2
1
1
1
1
B A
0
0
0
0
8Gb 6Gb 8Gb 6Gb
fibre SAS 1 X4 fibre SAS 1 X4
2 3 4 5 2 3 4 5
SP B SP A
VNX-000614
Table 4 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
1. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 21 on
page 24.
2. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 22 on
page 25.
3. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 23 on
page 26.
4. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 24 on
page 27.
VNX-000608
Table 5 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
SP
Figure 9 shows the part number label location on the SP.
3
3
2
2
1
1
0
0
8Gb 6Gb
fibre SAS 1
2 3 4 5 X4
6Gb SAS
0 X4
VNX-000613
Figure 9 Example of an SP
Table 6 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
To view the part number label of the SP CPU, the power supply/cooling fan module must
be removed from the SP unit.
To access the SP CPU, you must first remove the SP unit from the DPE (Figure 10 on
page 14). Then, you remove the power supply/cooling fan module from the SP unit
(Figure 11 on page 14).
Figure 10 shows the SP unit partially removed from the front of the DPE.
CL4594
Figure 11 shows the power supply/cooling module being removed from the SP unit.
CL4595
Figure 11 Example of removing the SP power supply/cooling module from the SP unit
The part number labels for the SP unit and the SP CPU module in Figure 12 are listed in
Table 6 on page 13. The SP CPU part number label is located on the motherboard of the SP
CPU (Figure 12).
SP SP CPU
part number (P/N) label part number (P/N) label
VNX-000665
Figure 12 Example of the SP CPU with power supply/cooling module set aside
Control Station
Figure 13 shows the part number label location on the front of the 1U Control Station.
SN: FNM000XXX000XX
NSXXX 0000 XXX 000
CNS-001544
Table 7 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Front view
AC AC AC AC
2 CNS-001723
Table 8 provides the part number label location, part number, description, and whether it
is a FRU or CRU.
Note: The part number label is located on the lower half of the pull handle.
AC AC
CNS-001682
Table 9 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
2
1
2
1
CL3972
Figure 16 Example of the Data Mover power supply/cooling fan module removal
Figure 17 on page 19 shows the Data Mover CPU module partially removed from the front
of the Data Mover enclosure with the two power supply/cooling fan modules set aside.
The part number label for the Data Mover CPU module in Figure 17 on page 19 is listed in
Table 10 on page 19.
Note: The DM CPU part numbers are located on the DM CPU sheet metal. You must remove
the DM from the DM enclosure (Figure 17 on page 19). You can also find the DM CPU part
number label located inside the DM CPU by looking through the blue plastic DIMM cover.
The part number label is located on the motherboard.
Power/cooling modules
1
2
2
2
Data Mover CPU CNS-001683
Figure 17 Example of the Data Mover CPU being removed from a Data Mover enclosure
Rear view
Figure 18 shows the part number label location on the rear of a Data Mover enclosure.
1 2 3 4 5
3
3
3
3
3
3
2
2
2
2
2
2
1
1
1
1
0
0
0
0
CNS-001724
Table 11 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Management module
Figure 19 shows the part number label location on the rear of the Data Mover enclosure
management module used in the Data Mover enclosure.
2
1
CNS-001684
Table 12 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
I/O modules
In the Block and File VNX5300 platform, I/O modules are used in the disk processor
enclosure (DPE) storage processors (SP A and B) and in the Data Movers of the Data Mover
enclosure.
Each I/O module is identified by a part number, type of ports (copper or optical), latch
handle label, and color label on top of the latch handle. For ease of identification,
Table 13 on page 22 describes each I/O module type in the VNX5300.
Latch
Latch handle handle
I/O module Part number Ports label label color
SP
Five types of I/O modules are supported in the SP:
◆ “Four-port 8-Gb/s Fibre Channel (FC) I/O module” on page 23
◆ “Four-port 1-Gb/s copper iSCSI I/O module” on page 24
◆ “Two-port 10-Gb/s optical (w/iSCSI protocol) I/O module” on page 25
◆ “Two-port 10-Gb/s Fibre Channel over Ethernet (FCoE) I/O module” on page 26
◆ “Two-port 10-Gb/s RJ-45 Base-T iSCSI/IP I/O module” on page 27
Data Mover
Seven types of I/O modules are supported in the Data Mover:
◆ “Four-port 8-Gb/s Fibre Channel (FC) I/O module” on page 23
◆ “Two-port 10-Gb/s Fibre Channel over Ethernet (FCoE) I/O module” on page 26
◆ “Two-port 10-Gb/s RJ-45 Base-T iSCSI/IP I/O module” on page 27
◆ “Two-port 1-Gb/s copper plus two-port 1-Gb/s optical I/O module” on page 28
◆ “Two-port 10-Gb/s optical I/O module” on page 29
◆ “Four-port 1-Gb/s copper I/O module” on page 30
◆ “Two-port 10-Gb/s optical I/O module” on page 31
The following sections describe these I/O modules and the part numbers. Refer to these
when determining which part number you need for either the SP or Data Mover that the
I/O module goes in.
CNS-001698
Table 14 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
CNS-001699
Table 15 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
CNS-001700
Figure 22 Example of the two-port 10-Gb/s optical (w/iSCSI protocol) I/O module
Table 16 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Table 16 Two-port 10-Gb-s optical (w/iSCSI protocol) I/O module part number
CNS-001700
Figure 23 Example of the two-port 10-Gb/s FCoE I/O module with SFPs1
Note: The 10-Gb/s FCoE I/O module requires VNX OE for File version 7.0.35.3 or later.
Table 17 shows the part number label location, part number, description, and whether it
is a FRU or CRU.
1. The FCoE I/O module can also use twinaxial (Twinax) cables. Twinax is a type of cable similar to coax, but with two inner conductors
instead of one. These cables will be supplied in lieu of SFPs when so ordered.
VNXe-000753
Figure 24 Example of the two-port 10-Gb/s RJ-45 Base-T iSCSI/IP I/O module
Note: The two-port 10-Gb/s RJ-45 Base-T iSCSI/IP I/O module requires VNX OE for File 7.1
or later.
Table 20 shows the part number label location, part number, description, and whether it
is a FRU or CRU.
Table 18 Two-port 10-Gb/s RJ-45 RJ-45 Base-T iSCSI/IP I/O module part number
CNS-001701
Figure 25 Example of the two-port 1-Gb/s copper plus two-port 1-Gb/s optical I/O module
Table 19 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Table 19 Two-port 1-Gb/s copper plus two-port 1-Gb/s optical I/O module part number
CNS-001700
Table 20 shows the part number label location, part number, description, and whether it
is a FRU or CRU.
CNS-001699
Table 21 shows the part number label location, part number, description, and whether it
is a FRU or CRU.
CNS-001700
Note: This two-port 10-Gb/s optical I/O module requires VNX OE for File version 7.1 or
later.
Table 22 shows the part number label location, part number, description, and whether it
is a FRU or CRU.
Note: The part number is visible only when the SFP or SFP + is removed from the I/O
module port.
The Block and File VNX5300 platform SFP or SFP+ modules are equipped with a Class 1
Laser, which emits invisible radiation. Do not stare into open optical ports. The following
warnings apply to the all SFP and SFP+ modules.
Class 1 laser product.
Because invisible laser radiation can be emitted from the aperture of the port when no
fiber is connected, avoid exposure to laser radiation and do not stare into open
apertures.
Laser radiation is present when the system is open and interlocks bypassed.
Only trained and qualified personnel should be allowed to install, replace, or service this
equipment.
IMPORTANT
Ensure that you correctly match the SFP or SFP+ module type with the I/O module type.
2. The 10 Gb/s module (labeled 10 GbE v3) can also use active twinaxial (Twinax) cables. Twinax is a
type of cable similar to coax, but with two inner conductors instead of one. These cables will be
supplied in lieu of SFPs when so ordered.
3. The FCoE I/O module can also use active twinaxial (Twinax) cables. Twinax is a type of cable
similar to coax, but with two inner conductors instead of one. These cables will be supplied in lieu
of SFPs when so ordered.
0
X-00
0 -XX
: 00
P/N
CNS-001347
Table 23 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Note: The SFP or SFP+ part number is visible only when the SFP or SFP+ is removed from an
I/O module port.
Note: Only the two optical ports (physically labeled on this I/O module as 2 and 3, but logically
fge-x-2 and fge-x-3) use this type of SFP.
DIMMs
The Storage Processor (SP) requires 4 GB per SP or a total of 8 GB per array and the Data
Mover requires 6 GB per Data Mover.
SP DIMMs
The SP CPU uses SDRAM DIMMs4. Each SP uses three 4-GB unbuffered Double-Data-Rate
3 (DDR3) type memory for a total of 12 GB per SP or 24 per DPE or array. Figure 30 on
page 36 shows an example of the location of the SP DIMM slots.
IMPORTANT
The DIMM part numbers are visible only when you remove the DIMM from the DIMM slot.
You must first take the SP out of service, disconnect any SP cables, remove the SP from the
DPE, then remove the SP power supply/cooling module from the SP (see Figure 10 on
page 14, Figure 11 on page 14, and Figure 12 on page 15). With the SP CPU laying on an
antistatic mat, lift the DIMM cover up in the SP CPU, and then remove the DIMM from the
DIMM slot. Ensure that you remove only those DIMMs that you intend to replace. For more
information about removing and installing the DIMM or memory module, refer to the
Replacing a memory module procedure available from the VNX Procedure Generator
program.
The DIMM memory is not hot-swappable. Before removing or replacing any DIMMs, you
must follow the removing and installing the DIMM or memory module procedure
described in the Replacing a memory module procedure available from the VNX
Procedure Generator program.
Note the orientation of the VNX5300 Block and File platform SP DIMMs (see locations
DIMM 0, DIMM 1, and DIMM 2 in Figure 30 on page 36). A label on the DIMM cover also
identifies the DIMM slots as DIMM 0, DIMM 1, and DIMM 2. In the VNX5300 Block and
File platform, the SP DIMMs are placed in slots 0, 1, and 2.
4. The term DIMM is used throughout this guide. The term DIMM is also referred to as a memory
module. These terms are interchangeable and basically mean the same thing.
DIMM 0
DIMM 1
DIMM 2
3 3
3 2
1
4
VNX-000610
Figure 30 Example of the Block and File VNX5300 platform SP DIMM slot location
Figure 31 Example of the Block and File VNX5300 platform SP DIMM part number location
Table 24 lists the SP DIMM part number location, description, and whether it is a FRU or
CRU.
IMPORTANT
The DIMM part numbers are visible only when you remove the DIMM from the DIMM slot.
You must first take the Data Mover out of service, disconnect any Data Mover cables,
remove the Data Mover from the DME, then remove the Data Mover power supply/cooling
module from the Data Mover (see Figure 16 on page 18 and Figure 17 on page 19). With
the Data Mover CPU laying on an antistatic mat, lift the DIMM cover up in the Data Mover
CPU, and then remove the DIMM from the DIMM slot. Ensure that you remove only those
DIMMs that you intend to replace. For more information about removing and installing the
DIMM or memory module, refer to the Replacing a memory module procedure available
from the VNX Procedure Generator program.
The DIMM memory is not hot-swappable. Before removing or replacing any DIMMs, you
must follow the removing and installing the DIMM or memory module procedure
described in the Replacing a memory module procedure available from the VNX
Procedure Generator program.
Note the orientation of the VNX5300 Block and File platform Data Mover DIMMs (see
locations DIMM 0, DIMM 1, DIMM 2, DIMM 3, DIMM 4, and DIMM 5 in Figure 32 on
page 38). A label on the DIMM cover also identifies the DIMM slots as DIMM 0, DIMM 1,
DIMM 2, DIMM 3, DIMM 4, and DIMM 5. In the VNX5300 Block and File platform, the Data
Mover DIMMs are placed in slots 0, 2, and 4. Slots 1, 3, and 5 are left empty.
D IMM M 2
IM
D IM M 3
M 1
D IM 4
0
D IMM M 5
D IM
D
DIMM 5
DIMM 4
DIMM 3
DIMM 2
DIMM 1
DIMM 0
CNS-001766
Figure 32 Example of the Block and File VNX5300 platform Data Mover DIMM slot location
Figure 33 shows the Data Mover DIMM part number label location.
Figure 33 Example of the Block and File VNX5300 platform Data Mover DIMM part number location
Table 25 lists the Data Mover DIMM part number label location, part number, description,
and whether it is a FRU or CRU.
Front view
The DAE has two types of disk drive carriers:
◆ 3U, 15 (3.5-inch) disk drive carrier
◆ 2U, 25 (2.5-inch) disk drive carrier
Note: You can visually distinguish disk module kinds by their type, capacity, and speed
labels, and by the design of the latch and handle on each disk module (Figure 34 on
page 40).
VNX-000607
Figure 34 Example of the 3U, 15 (3.5-inch) disk drive DAE (front view)
Note: Figure 34 is for illustrative purposes only. The front of the disk modules may be a
little different than the ones in your particular cabinet.
Table 26 is an example of the parts available for the 3U, 15 (3.5-inch) disk drive DAE and
lists the part number label location, part number, description, and whether it is a FRU or
CRU.
IMPORTANT
Due to the extensive variety of disk module types, Table 26 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.
Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).
Note: You can visually distinguish disk module kinds by their type, capacity, and speed
labels, and by the design of the latch and handle on each disk module (Figure 35).
VNX-000602
Figure 35 Example of the 2U, 25 (2.5-inch) disk drive DAE (front view)
Note: Figure 35 is for illustrative purposes only. The front of the disk modules may be a
little different than the ones in your particular cabinet.
Table 27 is an example of the parts available for the 2U, 25 (2.5-inch) disk drive DAE and
lists the part number label location, part number, description, and whether it is a FRU or
CRU.
IMPORTANT
Due to the extensive variety of disk module types, Table 27 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.
Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).
Rear view
The DAE has two types of LCC modules and power supplies:
◆ 3U, 15 DAE LCC and power supply
◆ 2U, 25 DAE LCC and power supply
1 2
LCC B
6Gb SAS
B #
X4
6Gb SAS
X4
A #
LCC A
VNX-000605
Table 28 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
2 303-108-000E LCC B
1. The rear of the 3U, 15 (3.5-inch) DAE has the LCC power supply and LCC inverted or on top of each other. In
other words, the LCC B power supply is located on the top of LCC B. While LCC A is located on the bottom of
the DAE with LCC A on top of the LCC A power supply (Figure 36).
1 2
X4
SAS
6 Gb
6 Gb
SAS
X4
#
VNX-000606
Table 29 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Table 29 2U, 25 (2.5-inch) DAE LCC and power supply part numbers
2 303-104-001E LCC B2
1. The rear of the 2U, 25 (2.5-inch) DAE has the LCC power supplies inverted or on opposite sides. In other
words, the LCC B power supply is located on the left of the DAE and the LCC A power supply is located on the
right (Figure 37).
2. The rear of the 2U, 25 (2.5-inch) DAE has the LCCs inverted or on top of each other. In other words, LCC B is
located on the top and LCC A is located on the bottom (Figure 37).
Copyright © 2013 EMC Corporation. All rights reserved. Published in the USA.
EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
notice.
The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any
kind with respect to the information in this publication, and specifically disclaims implied warranties of
merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this
publication requires an applicable software license.
EMC2, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries.
All other trademarks used herein are the property of their respective owners.
For the most up-to-date regulatory document for your product line, go to the technical documentation and advisories
section on EMC Online Support.