EMC® VNX® Family

VNX5300™

Parts Location Guide


P/N 300-013-313
Rev 02

January 24, 2013

This guide describes one of five models available in the VNX Series, the EMC®
VNX5300™. This guide is a parts location guide and provides illustrations of the part
number label locations of orderable parts for the EMC VNX5300 platform. Included in this
parts location guide are also tables describing the individual VNX5300 parts or
components and how these components are identified as either customer replaceable
units (CRUs) or field replaceable units (FRUs).

This guide is available online at https://mydocs.emc.com/VNX/relatedDocs.jsp. From the


VNX Hardware Parts heading, click on the desired guide. The guide will appear in your
browser.

Topics include:
◆ VNX5300 Block and File platform stackup ................................................................. 4
◆ VNX5300 components .............................................................................................. 7
◆ Standby power supply (SPS) ..................................................................................... 7
◆ Disk processor enclosure (DPE) ................................................................................. 8
◆ SP power supply/cooling module ............................................................................ 12
◆ SP........................................................................................................................... 13
◆ Control Station........................................................................................................ 15
◆ Data Mover enclosure ............................................................................................. 16
◆ Data Mover Power supply/cooling fan module......................................................... 17
◆ Data Mover CPU module.......................................................................................... 18
◆ Management module .............................................................................................. 21
◆ I/O modules............................................................................................................ 21
◆ Small form-factor pluggable (SFP) ........................................................................... 32
◆ DIMMs .................................................................................................................... 35
◆ Disk-array enclosure (DAE) ...................................................................................... 39
Product software and hardware release revisions

IMPORTANT
The part numbers listed in this guide are for reference only. Part numbers can change over
time, and this document does not keep pace with those changes. The EMC parts inventory
system will automatically substitute for the latest part numbers as required.

Product software and hardware release revisions


As part of an effort to improve its product lines, EMC periodically releases revisions of its
software and hardware. Therefore, some functions described in this document might not
be supported by all versions of the software or hardware currently in use. The product
release notes provide the most up-to-date information on product features.

Contact your EMC representative if a product does not function properly or does not
function as described in this document.

Note: This document was accurate at publication time. New versions of this document
might be released on the EMC online support website. Check the EMC online support
website to ensure that you are using the latest version of this document.

Revision history
The following table presents the revision history of this document:

Revision Date Description

02 January 24, 2013 Revised paragraph under Table 6 on


page 13.

01 June 26, 2012 First release of the VNX5300 Parts Location


Guide with a document part number.

Where to get help


EMC support, product, and licensing information can be obtained as follows:
Product information — For documentation, release notes, software updates, or
information about EMC products, licensing, and service, go to the EMC online support
website (registration required) at:
https://Support.EMC.com

Technical support — For technical support, go to EMC online support and select Support.
On the Support page, you will see several options, including one to create a service
request. Note that to open a service request, you must have a valid support agreement.
Contact your EMC sales representative for details about obtaining a valid support
agreement or with questions about your account.

2 EMC VNX5300 Parts Location Guide


How this document is organized

How this document is organized


The major sections of this guide are listed in the following table.

Title Description

“VNX5300 Block and File Describes and shows the front and rear views of a typical
platform stackup” on page 4 VNX5300.

“VNX5300 components” on Provides a description of the components that comprise a


page 7 VNX5300. Along with a description, illustrations of each
component are also shown.

“Standby power supply (SPS)” Describes and illustrates the part number label locations of the
on page 7 SPS.

“Disk processor enclosure Describes and illustrates the part number label locations of the
(DPE)” on page 8 DPE and the components that comprise the DPE.

“Control Station” on page 15 Describes and illustrates the part number label locations of the
CS.

“Data Mover enclosure” on Describes and illustrates the part number label locations of the
page 16 DME and the management module.

“I/O modules” on page 21 Describes and illustrates the part number label locations of the
I/O modules that comprise the DPE and the DME.

“Small form-factor pluggable Describes and illustrates the part number label locations of the
(SFP)” on page 32 SFP transceiver modules used in the DME.

“DIMMs” on page 35 Describes and illustrates the part number label locations of the
memory module or dual-inline memory modules (DIMMs) used
in the DPE and the DME.

“Disk-array enclosure (DAE)” on Describes and illustrates the part number label locations of the
page 39 two types of DAEs available for the VNX5300.

Related documentation
EMC provides the ability to create step-by-step planning, installation, and maintenance
instructions tailored to your environment. To create VNX customized documentation, go
to: https://mydocs.emc.com/VNX/.

To download a PDF copy of the desired publication, go to the following sections:


◆ For hardware-related books, go to the About VNX section, and then select Learn about
VNX. Next, follow the steps in the wizard.
◆ For technical specifications, go to the About VNX section, and then select View
technical specifications. Next, follow the steps in the wizard.
◆ For installation, adding, or replacing tasks, go to the VNX tasks section, and then
select the appropriate heading. For example, to download a PDF copy of the VNX5300
Block Installation Guide, go to Install VNX and follow the steps in the wizard.

EMC VNX5300 Parts Location Guide 3


VNX5300 Block and File platform stackup

◆ For server-related tasks, go to the Server tasks for the VNX5300, VNX5500, VNX5700,
and VNX7500 section, and then select the appropriate heading. For example, to
download a PDF copy of Adding or replacing hardware, go to Add or replace hardware
and follow the steps in the wizard.

VNX5300 Block and File platform stackup


The VNX5300 Block and File platform comprises a 1U standby power supply (SPS), a 3U
disk processor enclosure (DPE), a 1U Control Station, a 2U Data Mover enclosure.

Note: Throughout this guide, figure references are placed in the Part number label location
heading of tables because some of the tables have part number locations, as described in
Table 4 on page 11 and some do not, as described in Table 1 on page 8, for example. This
format is used throughout this guide.

Front view
On the front, viewing from top to bottom, a Block and File VNX5300 platform includes the
following hardware:
◆ One 2U Data Mover enclosure with one to two Data Movers
◆ One to two 1U Control Stations
◆ One 3U DPE chassis with either a:
• 15 (3.5-inch) disk drives (hot-swappable)
or,
• 25 (2.5-inch) disk drives (hot-swappable)
◆ One dual 1U standby power supply (SPS)

4 EMC VNX5300 Parts Location Guide


VNX5300 Block and File platform stackup

Figure 1 shows an example of the front of a Block and File VNX5300 platform with a 3U, 15
(3.5-inch) DPE.

AC AC AC AC

Data Mover
Enclosure 0

DVD
Control Station 1
(optional)
DVD
Control Station 0

3U, 15 (3.5-inch)
disk processor
enclosure (DPE)

SPS
VNX-000562

Figure 1 Example of the Block and File VNX5300 platform with a 3U, 15 (3.5-inch) DPE (front view)

Figure 2 shows an example of the front of a Block and File VNX5300 platform with a 3U, 25
(2.5-inch) DPE.

AC AC AC AC

Data Mover
enclosure 0

DVD
Control Station 1
(optional)
DVD
Control Station 0

0 24

3U, 25 (2.5-inch)
disk processor
enclosure (DPE)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

SPS
VNX-000612

Figure 2 Example of the Block and File VNX5300 platform with a 3U, 25 (2.5-inch) DPE (front view)

EMC VNX5300 Parts Location Guide 5


VNX5300 Block and File platform stackup

Note: A Block and File VNX5300 platform has one 2U Data Mover enclosure, one 1U
Control Station, one 3U DPE, and one dual 1U SPS. In the following sections, the
illustrations and corresponding tables describe these individual components. These
descriptions are for illustrative purposes only.

Rear view
On the rear, viewing from top to bottom, a Block and File VNX5300 platform includes the
following hardware components:
◆ One 2U Data Mover enclosure with two Data Movers
◆ One to two 1U Control Stations
◆ One 3U DPE with two storage processors (SP A and B); each SP has one CPU module
and one power supply/cooling module
◆ One dual 1U SPS

Figure 3 shows an example of the rear of a Block and File VNX5300 platform.

3
3

3
3

3
3

3
3

2 Data Mover
2

2
2

2
2

2
2

Enclosure 0
1

1
1

1
1

0
0

0
0

CS B MGMT

Control Station 1
A
(optional)
CS B MGMT

Control Station 0
A

PART NUMBER PART NUMBER PART NUMBER PART NUMBER


REV A09 A REV A09 A REV A09 A REV A09 A
3
3

3
3

2
2

2
2

Disk
1
1

1
1

B A processor
0
0

0
0

2 3 4 5
8Gb 6Gb
fibre SAS 1 X4
2 3 4 5
8Gb 6Gb
fibre SAS 1 X4 enclosure

6Gb SAS 6Gb SAS


0 X4 0 X4

SPS
VNX-000563

Figure 3 Example of Block and File VNX5300 platform (rear view)

6 EMC VNX5300 Parts Location Guide


VNX5300 components

VNX5300 components
Viewing from the bottom to the top, the Block and File VNX5300 platform includes several
components. The following sections discuss each component in an illustration and table.
The illustration will show or point out the location of the part number label on the
component. The table will list the part number, describe the component or part, and tell
you if it is a FRU or CRU or both.
◆ Dual 1U standby power supply (SPS)
◆ 3U Disk processor enclosure (DPE)
• 3U, 15 (3.5-inch) disk drive
• 3U, 25 (2.5-inch) disk drive
• Storage processor (SP) power supply/cooling module
• Storage processor
◆ 1U Control Station (CS)
◆ 2U Data Mover enclosure (DME)
• DME power supply/cooling module
• DME CPU module
• Management module
◆ I/O modules
• SP I/O modules
• DME I/O modules
◆ Small form-factor pluggable (SFP) transceiver modules
◆ Dual in-line memory modules (DIMMs)
• SP DIMMs
• DME DIMMs
◆ 2U or 3U Disk-array enclosures (DAEs)
• 3U, 15 (3.5-inch) disk drive
• 2U, 25 (2.5-inch) disk drive

Standby power supply (SPS)


The Block and File VNX5300 platform can support up to two standby power supplies or a
dual 1U SPS to provide temporary emergency power to the Block and File VNX5300
platform. Part numbers for the 1U SPS are only on the rear of the product.

Figure 4 shows the part number label location on the SPS.

EMC VNX5300 Parts Location Guide 7


Disk processor enclosure (DPE)

S/N S/N
900-XXX-0014 0082 900-XXX-0014 0082

REV A00 REV A00

Part Number (P/N) label CNS-001545

Figure 4 Example of a dual 1U SPS

Table 5 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 1 SPS part number

Part number label


location (Figure 4
on page 8) Part number Description FRU CRU

078-000-084 DC standby power supply (SPS)  


078-000-085 1200W

Disk processor enclosure (DPE)


The 3U DPE has part numbers visible on both the front and rear.

Front view
The 3U DPE supports two types of disk drive carriers:
◆ 3U, 15 (3.5-inch) disk drives
◆ 3U, 25 (2.5-inch) disk drives

DPE 3U, 15 (3.5-inch) disk drive


Figure 5 on page 9 shows the front view of the DPE 3U, 15 (3.5-inch) disk drives.

Note: You can visually distinguish disk module kinds by their type, capacity, and speed
labels, and by the design of the latch and handle on each disk module (Figure 5 on
page 9).

8 EMC VNX5300 Parts Location Guide


Disk processor enclosure (DPE)

Part Number Label

VNX-000607

Figure 5 Example of the DPE 3U, 15 (3.5-inch) disk drive (front view)

Note: Figure 5 is for illustrative purposes only. The front of the disk modules may be a little
different than the ones in your particular cabinet.

Table 2 is an example of the parts available for the 3U, 15 (3.5-inch) DPE and lists the part
number label location, part number, description, and whether it is a FRU or CRU.

IMPORTANT
Due to the extensive variety of disk module types, Table 2 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.

Table 2 DPE 3U, 15 (3.5-inch) disk module part numbers

Part number label


location (Figure 5) Part number Description (see note) FRU CRU

005049299 300 GB, 6 Gb/s SAS, 10k rpm  

005049301 600 GB, 6 Gb/s SAS, 15k rpm  

Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).

EMC VNX5300 Parts Location Guide 9


Disk processor enclosure (DPE)

DPE 3U, 25 (2.5-inch) disk drive


Figure 6 shows the front view of the DPE 3U, 25 (2.5-inch) disk drives.

Note: You can visually distinguish disk module kinds by their type, capacity, and speed
labels, and by the design of the latch and handle on each disk module (Figure 6).

Part Number Label

0 24

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

VNX-000603

Figure 6 Example of the DPE 3U, 25 (2.5-inch) disk drive (front view)

Note: Figure 6 is for illustrative purposes only. The front of the disk modules may be a little
different than the ones in your particular cabinet.

Table 3 is an example of the parts available for the 3U, 25 (2.5-inch) DPE and lists the part
number label location, part number, description, and whether it is a FRU or CRU.

IMPORTANT
Due to the extensive variety of disk module types, Table 3 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.

Table 3 DPE 3U, 25 (2.5-inch) disk module part numbers

Part number label


location (Figure 6) Part number Description (see note) FRU CRU

005049292 300 GB, 6 Gb/s SAS, 10k rpm  

005049294 600 GB, 6 Gb/s SAS, 10k rpm  

Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).

10 EMC VNX5300 Parts Location Guide


Disk processor enclosure (DPE)

Rear view
Figure 7 shows the rear view of the 3U disk processor enclosure (DPE) with two storage
processors (SP A and B).

1 2 3 4

PART NUMBER PART NUMBER PART NUMBER PART NUMBER


REV A09 A REV A09 A REV A09 A REV A09 A

3
3

3
3

2
2

2
2

1
1

1
1
B A

0
0

0
0
8Gb 6Gb 8Gb 6Gb
fibre SAS 1 X4 fibre SAS 1 X4
2 3 4 5 2 3 4 5

6Gb SAS 6Gb SAS


0 X4 0 X4

SP B SP A
VNX-000614

Figure 7 Example of 3U DPE with two SPs (A and B)

Table 4 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 4 DPE chassis and SP part numbers

Part number label


location (Figure 7
on page 11) Part number Description FRU CRU

1 100-562-503 3U, 15 disk drive chassis and  


100-563-138 midplane
3U, 25 disk drive chassis and  
midplane

2 110-140-408B SP, 1.6 GHZ QC CPU, 8-GB RAM (for


a closer view, see Figure 9 on
page 13)

110-140-400B SP, 1.6-GHz GHZ QC CPU, DIMMs 


(for a closer view, see Figure 9 on
page 13)

3 071-000-529 1U AC/DC, 875W, dual power  


supply (for a closer view, see
Figure 8 on page 12)

4 303-092-102B Four-port 8-Gb/s FC (2/4/8 Gb/s)  

303-141-100A1 Four-port 1-Gb/s copper iSCSI I/O  


module

303-081-105B2 Two-port 10-Gb/s optical with iSCSI  


protocol I/O module

EMC VNX5300 Parts Location Guide 11


Disk processor enclosure (DPE)

Table 4 DPE chassis and SP part numbers (continued)

Part number label


location (Figure 7
on page 11) Part number Description FRU CRU

303-142-100A3 Two-port 10-Gb/s FCoE I/O module  

303-164-104D-014 Two-port 10-Gb/s RJ-45 Base-T  


iSCSI/IP

100-562-718 I/O module filler panel includes a


Do Not Remove label

Note: This filler panel is only used


when the SP I/O module slots are
empty.

1. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 21 on
page 24.
2. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 22 on
page 25.
3. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 23 on
page 26.
4. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 24 on
page 27.

SP power supply/cooling module


Figure 8 shows the part number label location on power supply/cooling module used in
the Block and File VNX5300 platform SPs (A and B).

Part number (P/N) label

VNX-000608

Figure 8 Example of a power supply module/cooling

Table 5 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 5 Power supply module/cooling fan part number

Part number label


location
(Figure 8) Part number Description FRU CRU

071-000-529 1U AC/DC, 875W, dual power 


supply

12 EMC VNX5300 Parts Location Guide


Disk processor enclosure (DPE)

SP
Figure 9 shows the part number label location on the SP.

SP part number (P/N) label

PART NUMBER PART NUMBER


REV A09 A REV A09 A

3
3

2
2

1
1

0
0
8Gb 6Gb
fibre SAS 1
2 3 4 5 X4

6Gb SAS
0 X4

VNX-000613

Figure 9 Example of an SP

Table 6 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 6 SP CPU part number

Part number label


location (Figure 9
on page 13) Part number Description FRU CRU

110-140-408B SP 1.6-GHZ CPU, with 8 GB of


memory

110-140-400B SP 1.6-GHZ CPU, without memory 

To view the part number label of the SP CPU, the power supply/cooling fan module must
be removed from the SP unit.

To access the SP CPU, you must first remove the SP unit from the DPE (Figure 10 on
page 14). Then, you remove the power supply/cooling fan module from the SP unit
(Figure 11 on page 14).

EMC VNX5300 Parts Location Guide 13


Disk processor enclosure (DPE)

Figure 10 shows the SP unit partially removed from the front of the DPE.

CL4594

Figure 10 Example of removing the SP from the 3U DPE

Figure 11 shows the power supply/cooling module being removed from the SP unit.

CL4595

Figure 11 Example of removing the SP power supply/cooling module from the SP unit

14 EMC VNX5300 Parts Location Guide


Control Station

The part number labels for the SP unit and the SP CPU module in Figure 12 are listed in
Table 6 on page 13. The SP CPU part number label is located on the motherboard of the SP
CPU (Figure 12).

SP Power supply/cooling module

SP SP CPU
part number (P/N) label part number (P/N) label
VNX-000665

Figure 12 Example of the SP CPU with power supply/cooling module set aside

Control Station
Figure 13 shows the part number label location on the front of the 1U Control Station.

Part Number (P/N) label


PN: 900-XXX-0014 (NSXXX)
NSXXX 0000 XXX 000

SN: FNM000XXX000XX
NSXXX 0000 XXX 000

CNS-001544

Figure 13 Example of the Control Station (front view)

Table 7 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 7 Control Station front view part number

Part number label


location
(Figure 13) Part number Description FRU CRU

100-520-665 Control Station (CS) 1U 

EMC VNX5300 Parts Location Guide 15


Data Mover enclosure

Data Mover enclosure


Figure 14 shows the part number location on the front of the 2U Data Mover enclosure.

Front view

AC AC AC AC

2 CNS-001723

Figure 14 Data Mover enclosure (front view)

Table 8 provides the part number label location, part number, description, and whether it
is a FRU or CRU.

Table 8 Data Mover enclosure front view part numbers

Part number label


location
(Figure 14 on
page 16) Part number Description FRU CRU

1 071-000-5431 Data Mover enclosure 400 W, 2U,  


single 12 V output power
supply/cooling fan module (for a
closer view, see Figure 15 on
page 17)

2 110-113-102B Data Mover 2.4-GHz CPU module


with 6 GB of memory (for a closer
view, see Figure 17 on page 19)

303-113-101B Data Mover 2.4-GHz CPU module  


without memory (for a closer view,
see Figure 17 on page 19)
1. The part number label on the power supply/cooling fan module is located on the lower half of the pull
handle.

16 EMC VNX5300 Parts Location Guide


Data Mover enclosure

Data Mover Power supply/cooling fan module


Figure 15 shows the part number label location on the front of the two power
supply/cooling fan modules used in the Data Mover enclosure.

Note: The part number label is located on the lower half of the pull handle.

Part Number (P/N) label

AC AC

CNS-001682

Figure 15 Example of a power supply module/cooling fan (front view)

Table 9 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 9 Power supply module/cooling fan part number

Part number label


location
(Figure 15 on
page 17) Part number Description FRU CRU

071-000-543 Data Mover enclosure 400 W, 2U,  


single 12 V output power
supply/cooling fan module

EMC VNX5300 Parts Location Guide 17


Data Mover enclosure

Data Mover CPU module


To access the Data Mover CPU, you must first remove the power supply/cooling fan
modules (Figure 16).

2
1

2
1

CL3972

Figure 16 Example of the Data Mover power supply/cooling fan module removal

Figure 17 on page 19 shows the Data Mover CPU module partially removed from the front
of the Data Mover enclosure with the two power supply/cooling fan modules set aside.
The part number label for the Data Mover CPU module in Figure 17 on page 19 is listed in
Table 10 on page 19.

Note: The DM CPU part numbers are located on the DM CPU sheet metal. You must remove
the DM from the DM enclosure (Figure 17 on page 19). You can also find the DM CPU part
number label located inside the DM CPU by looking through the blue plastic DIMM cover.
The part number label is located on the motherboard.

18 EMC VNX5300 Parts Location Guide


Data Mover enclosure

Power/cooling modules

Data Mover enclosure

Part Number (P/N) label

1
2
2

2
Data Mover CPU CNS-001683

Figure 17 Example of the Data Mover CPU being removed from a Data Mover enclosure

Table 10 Data Mover CPU part number

Part number label


location Part number Description FRU CRU

Figure 14 on 110-113-102B Data Mover 2.4-GHz CPU module


page 16 with 6 GB of memory

Figure 17 on 303-113-101B Data Mover 2.4-GHz CPU module 


page 19 without memory

Rear view
Figure 18 shows the part number label location on the rear of a Data Mover enclosure.

1 2 3 4 5
3
3

3
3

3
3

2
2

2
2

2
2

1
1

1
1

0
0

0
0

CNS-001724

Figure 18 Data Mover enclosure (rear view)

EMC VNX5300 Parts Location Guide 19


Data Mover enclosure

Table 11 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 11 Data Mover enclosure part numbers rear view

Part number label


location
(Figure 18 on
page 19) Part number Description FRU CRU

1 100-562-178 Data Mover enclosure (empty) 

2 110-130-100B Management module (for a closer  


view, see Figure 19 on page 21)

3 303-092-102B Four-port 8-Gb/s Fibre Channel (FC)  


I/O module (for a closer view, see
Figure 20 on page 23)

4 303-122-100A Two-port 1-Gb/s copper plus  


two-port 1G/bs optical I/O module
(for a closer view, see Figure 25 on
page 28)

5 100-562-718 I/O module filler panel includes Do  


Not Remove label

Note: This filler panel is only used


when the Data Mover I/O module
slots are empty.

303-121-100A1 Four-port 10/100/1000 Base-T  


copper I/O module (for a closer
view, see Figure 27 on page 30)

303-081-103B2 Two-port 10-Gb/s Ethernet optical  


I/O module (for a closer view, see
Figure 26 on page 29)

303-195-100B3 Two-port 10-Gb/s Ethernet optical  


or Twinax I/O module (for a closer
view, see Figure 28 on page 31)

303-164-104D-014 Two-port 10-Gb/s RJ-45 Base-T  


iSCSI/IP (for a closer view, see
Figure 24 on page 27)
1. This part is not shown in the example Data Mover enclosure illustration in Figure 18 on page 19. For a closer
view, go to Figure 27 on page 30.
2. This part is not shown in the example Data Mover enclosure illustration in Figure 18 on page 19. For a closer
view, go to Figure 22 on page 25.
3. This part is not shown in the example Data Mover enclosure illustration in Figure 18 on page 19. For a closer
view, go to Figure 28 on page 31.
4. This part is not shown in the example Data Mover enclosure illustration in Figure 18 on page 19. For a closer
view, go to Figure 24 on page 27.

20 EMC VNX5300 Parts Location Guide


I/O modules

Management module
Figure 19 shows the part number label location on the rear of the Data Mover enclosure
management module used in the Data Mover enclosure.

Part Number (P/N label

2
1

CNS-001684

Figure 19 Example of the Data Mover enclosure management module

Table 12 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 12 Data Mover enclosure management module part number

Part number label


location
(Figure 19) Part number Description FRU CRU

110-130-100B Management module  

I/O modules
In the Block and File VNX5300 platform, I/O modules are used in the disk processor
enclosure (DPE) storage processors (SP A and B) and in the Data Movers of the Data Mover
enclosure.

Each I/O module is identified by a part number, type of ports (copper or optical), latch
handle label, and color label on top of the latch handle. For ease of identification,
Table 13 on page 22 describes each I/O module type in the VNX5300.

EMC VNX5300 Parts Location Guide 21


I/O modules

Table 13 I/O module types for VNX5300

Latch
Latch handle handle
I/O module Part number Ports label label color

Four-port 8-Gb/s FC 303-092-102B Optical 8 Gb Fibre Silver

Four-port 1-Gb/s 303-141-100A Copper 1 GbE iSCSI/TOE Orange

Two-port 10-Gb/s (w/iSCSI) 303-081-105B Optical 10 GbE Orange

Two-port 10-Gb/s FCoE 303-142-100A Optical 10 GbE/FCoE Green

Two-port 10-Gb/s RJ-45 303-164-104D-01 Copper 10 GbE Base-T Orange


Base-T iSCSI/IP

Two-port 1-Gb/s copper 303-122-100A or B Copper 1 GbE Brown


plus two-port 1-Gb/s plus
optical optical

Two-port 10-Gb/s 303-081-103B or C Optical 10 GbE iSCSI or Orange


10 GbE v2

Two-port 10-Gb/s 303-195-100C-01 Optical 10 GbE v3 Orange

Four-port 10/100/1000 303-121-100A Copper 1 GbE Brown


Ethernet

SP
Five types of I/O modules are supported in the SP:
◆ “Four-port 8-Gb/s Fibre Channel (FC) I/O module” on page 23
◆ “Four-port 1-Gb/s copper iSCSI I/O module” on page 24
◆ “Two-port 10-Gb/s optical (w/iSCSI protocol) I/O module” on page 25
◆ “Two-port 10-Gb/s Fibre Channel over Ethernet (FCoE) I/O module” on page 26
◆ “Two-port 10-Gb/s RJ-45 Base-T iSCSI/IP I/O module” on page 27

Data Mover
Seven types of I/O modules are supported in the Data Mover:
◆ “Four-port 8-Gb/s Fibre Channel (FC) I/O module” on page 23
◆ “Two-port 10-Gb/s Fibre Channel over Ethernet (FCoE) I/O module” on page 26
◆ “Two-port 10-Gb/s RJ-45 Base-T iSCSI/IP I/O module” on page 27
◆ “Two-port 1-Gb/s copper plus two-port 1-Gb/s optical I/O module” on page 28
◆ “Two-port 10-Gb/s optical I/O module” on page 29
◆ “Four-port 1-Gb/s copper I/O module” on page 30
◆ “Two-port 10-Gb/s optical I/O module” on page 31

22 EMC VNX5300 Parts Location Guide


I/O modules

The following sections describe these I/O modules and the part numbers. Refer to these
when determining which part number you need for either the SP or Data Mover that the
I/O module goes in.

Four-port 8-Gb/s Fibre Channel (FC) I/O module


Figure 20 shows the part number label location on the four-port 8-Gb/s Fibre Channel (FC)
I/O module (labeled 8 Gb Fibre on the latch handle).

Part Number (P/N) Label

CNS-001698

Figure 20 Example of the four-port 8-Gb/s FC I/O module

Table 14 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 14 Four-port 8-Gb/s FC I/O module part numbers

Part number label


location
(Figure 20) Part number Description FRU CRU

303-092-102B Four-port 8-Gb/s FC (2/4/8 Gb/s)  

EMC VNX5300 Parts Location Guide 23


I/O modules

Four-port 1-Gb/s copper iSCSI I/O module


Figure 21 shows the part number label location on the four-port 1-Gb/s copper iSCSI I/O
module (labeled 1 GbE iSCSI/TOE on the latch handle).

Part Number (P/N) Label

CNS-001699

Figure 21 Example of the four-port 1-Gb/s copper iSCSI I/O module

Table 15 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 15 Four-port 1-Gb/s copper iSCSI I/O module part number

Part number label


location
(Figure 21) Part number Description FRU CRU

303-141-100A Four 1-Gb/s copper iSCSI ports  

24 EMC VNX5300 Parts Location Guide


I/O modules

Two-port 10-Gb/s optical (w/iSCSI protocol) I/O module


Figure 22 shows the part number label location on the two-port 10-Gb/s optical (w/iSCSI
protocol) I/O module (labeled 10 GbE on the latch handle).

Part Number (P/N) Label

CNS-001700

Figure 22 Example of the two-port 10-Gb/s optical (w/iSCSI protocol) I/O module

Table 16 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 16 Two-port 10-Gb-s optical (w/iSCSI protocol) I/O module part number

Part number label


location
(Figure 22) Part number Description FRU CRU

303-081-105B Two-port 10-Gb/s optical (w/iSCSI  


protocol) I/O module

EMC VNX5300 Parts Location Guide 25


I/O modules

Two-port 10-Gb/s Fibre Channel over Ethernet (FCoE) I/O module


Figure 23 shows the part number label location on the two-port 10-Gb/s Fibre Channel
over Ethernet (FCoE) I/O module (labeled 10 GbE/FCoE on the latch handle).

Part Number (P/N) Label

CNS-001700

Figure 23 Example of the two-port 10-Gb/s FCoE I/O module with SFPs1

Note: The 10-Gb/s FCoE I/O module requires VNX OE for File version 7.0.35.3 or later.

Table 17 shows the part number label location, part number, description, and whether it
is a FRU or CRU.

Table 17 Two-port 10-Gb/s FCoE I/O module part numbers

Part number label


location
(Figure 23) Part number Description FRU CRU

303-142-100A Two-port 10-Gb/s FCoE  

1. The FCoE I/O module can also use twinaxial (Twinax) cables. Twinax is a type of cable similar to coax, but with two inner conductors
instead of one. These cables will be supplied in lieu of SFPs when so ordered.

26 EMC VNX5300 Parts Location Guide


I/O modules

Two-port 10-Gb/s RJ-45 Base-T iSCSI/IP I/O module


Figure 26 shows the part number label location on the two-port 10-Gb/s RJ-45 Base-T
iSCSI/IP I/O module (labeled 10 GbE BASE-T on the latch handle).

Part Number (P/N) Label

VNXe-000753

Figure 24 Example of the two-port 10-Gb/s RJ-45 Base-T iSCSI/IP I/O module

Note: The two-port 10-Gb/s RJ-45 Base-T iSCSI/IP I/O module requires VNX OE for File 7.1
or later.

Table 20 shows the part number label location, part number, description, and whether it
is a FRU or CRU.

Table 18 Two-port 10-Gb/s RJ-45 RJ-45 Base-T iSCSI/IP I/O module part number

Part number label


location
(Figure 24) Part number Description FRU CRU

303-164-104D-01 Two-port 10-Gb/s RJ-45 Base-T  


iSCSI/IP I/O module

EMC VNX5300 Parts Location Guide 27


I/O modules

Two-port 1-Gb/s copper plus two-port 1-Gb/s optical I/O module


Figure 25 shows the part number label location on the two-port 1-Gb/s copper plus
two-port 1-Gb/s optical I/O module (labeled 1 GbE on the latch handle).

Part Number (P/N) Label

CNS-001701

Figure 25 Example of the two-port 1-Gb/s copper plus two-port 1-Gb/s optical I/O module

Table 19 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 19 Two-port 1-Gb/s copper plus two-port 1-Gb/s optical I/O module part number

Part number label


location
(Figure 25) Part number Description FRU CRU

303-122-100A or B Two-port 1-Gb/s copper plus  


two-port 1-Gb/s optical

28 EMC VNX5300 Parts Location Guide


I/O modules

Two-port 10-Gb/s optical I/O module


Figure 26 shows the part number label location on the two-port 10-Gb/s optical I/O
module (labeled 10 GbE iSCSI or 10 GbE v2 on the latch handle).

Part Number (P/N) Label

CNS-001700

Figure 26 Example of the two-port optical I/O module

Table 20 shows the part number label location, part number, description, and whether it
is a FRU or CRU.

Table 20 Two-port optical I/O module part number

Part number label


location
(Figure 26) Part number Description FRU CRU

303-081-103B or C Two-port 10-Gb/s optical I/O  


module

EMC VNX5300 Parts Location Guide 29


I/O modules

Four-port 1-Gb/s copper I/O module


Figure 27 shows the part number label location on the four-port 1-Gb/s copper I/O
module (labeled 1 GbE on the latch handle).

Part Number (P/N) Label

CNS-001699

Figure 27 Example of the four-port 1-Gb/s copper I/O module

Table 21 shows the part number label location, part number, description, and whether it
is a FRU or CRU.

Table 21 Four-port 1-Gb/s copper I/O module part number

Part number label


location
(Figure 27) Part number Description FRU CRU

303-121-100A Four 1-Gbs copper ports  

30 EMC VNX5300 Parts Location Guide


I/O modules

Two-port 10-Gb/s optical I/O module


Figure 26 shows the part number label location on the two-port 10-Gb/s optical or active
Twinax I/O module (labeled 10 GbE v3 on the latch handle).

Part Number (P/N) Label

CNS-001700

Figure 28 Example of the two-port 10-Gb/s optical I/O module

Note: This two-port 10-Gb/s optical I/O module requires VNX OE for File version 7.1 or
later.

Table 22 shows the part number label location, part number, description, and whether it
is a FRU or CRU.

Table 22 Two-port 10-Gb/s optical I/O module part number

Part number label


location
(Figure 28) Part number Description FRU CRU

303-195-100C-01 Two-port 10-Gb/s Optical I/O  


module

EMC VNX5300 Parts Location Guide 31


Small form-factor pluggable (SFP)

Small form-factor pluggable (SFP)


Small form-factor (SFP) modules are compact, hot-pluggable transceivers inserted into
the SFP or SFP+ slot of an I/O module in a Block and File VNX5300 platform. This
transceiver module provides uplink optical interfaces, laser send or transmit (TX) and
laser receive (RX). An SFP or SFP+ transceiver module is hot-swappable. You can replace
an SFP or SFP+ from the rear of the SP or Data Mover while the platform is powered up.

Note: The part number is visible only when the SFP or SFP + is removed from the I/O
module port.

Laser safety guidelines


Before you install SFP or SFP+ modules in a Block and File VNX5300 platform or attempt to
operate or service a Block and File VNX5300 platform equipped with SFP modules, you
must read and observe the important safety information in this section of the document.

The Block and File VNX5300 platform SFP or SFP+ modules are equipped with a Class 1
Laser, which emits invisible radiation. Do not stare into open optical ports. The following
warnings apply to the all SFP and SFP+ modules.


Class 1 laser product.

Because invisible laser radiation can be emitted from the aperture of the port when no
fiber is connected, avoid exposure to laser radiation and do not stare into open
apertures.

Laser radiation is present when the system is open and interlocks bypassed.

Only trained and qualified personnel should be allowed to install, replace, or service this
equipment.

Guidelines for handling SFP and SFP+ modules


Use these guidelines when you work with SFP and SFP+ modules:
◆ SFP and SFP+ modules are static sensitive. Wear an ESD-preventive wrist strap that is
connected to the rack in order to prevent ESD damage.
◆ SFP and SFP+ modules are dust sensitive. Always store the devices with dust plugs
installed in the optical bores.
◆ Do not remove and insert an SFP or SFP+ module more often than is necessary.
Repeated removals and insertions of an SFP or SFP+ module can shorten its useful
life.

32 EMC VNX5300 Parts Location Guide


Small form-factor pluggable (SFP)

Types of SFP and SFP+ module latches


SFP transceiver modules can have three types of latching devices to secure the SFP or
SFP+ transceiver in a port socket.
◆ SFP or SFP+ transceiver with a Mylar tab latch.
◆ SFP or SFP+ transceiver with an actuator button latch.
◆ SFP or SFP + transceiver that has a bale-clasp latch.

I/O modules using SFP or SFP+ transceiver modules


In the VNX5300 platform, the SFP or SFP+ transceiver modules are located in the ports of
the following I/O modules:
◆ Four-port 8-Gb/s Fibre Channel (FC) for 2, 4, and 8 Gb/s speed
◆ Two-port 1-Gb/s copper plus two-port 1-Gb/s optical
◆ Two-port 10-Gb/s optical (labeled 10 GbE iSCSI or 10 GbE v2)
◆ Two-port 10-Gb/s optical2 (labeled 10 GbE v3)
◆ Two-port 10-Gb/s Fibre Channel over Ethernet (FCoE)3

Types of SFP and SFP+ modules


Three types of SFP or SFP+ modules are used in the I/O modules of the Block and File
VNX5300 platform. Figure 29 on page 34 shows an example of an SFP or SFP+ with a bale
clasp and the part number label.

IMPORTANT
Ensure that you correctly match the SFP or SFP+ module type with the I/O module type.

2. The 10 Gb/s module (labeled 10 GbE v3) can also use active twinaxial (Twinax) cables. Twinax is a
type of cable similar to coax, but with two inner conductors instead of one. These cables will be
supplied in lieu of SFPs when so ordered.
3. The FCoE I/O module can also use active twinaxial (Twinax) cables. Twinax is a type of cable
similar to coax, but with two inner conductors instead of one. These cables will be supplied in lieu
of SFPs when so ordered.

EMC VNX5300 Parts Location Guide 33


Small form-factor pluggable (SFP)

0
X-00
0 -XX
: 00
P/N

Part Number (P/N) label

CNS-001347

Figure 29 Example of an SFP with a bale clasp

Table 23 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Note: The SFP or SFP+ part number is visible only when the SFP or SFP+ is removed from an
I/O module port.

Table 23 SFP and SFP+ module part numbers

Part number label


location
(Figure 29) Part number Description FRU CRU

019-078-032 Used in the two-port 1-Gb/s copper  


(SFP) plus two-port 1-Gb/s Optical I/O
module (see note)

019-078-041 Used in the two-port 10-Gb/s FCoE  


(SFP+) I/O module

Used in the two-port 10-Gb/s optical  


I/O module (latch label 10 GbE iSCSI
or v2)

Used in the two-port 10-Gb/s optical  


I/O module (latch label 10-GbE v3)

019-078-042 Used in the four-port 8-Gb/s Fibre  


(SFP+) Channel (FC) I/O module

Note: Only the two optical ports (physically labeled on this I/O module as 2 and 3, but logically
fge-x-2 and fge-x-3) use this type of SFP.

34 EMC VNX5300 Parts Location Guide


DIMMs

DIMMs
The Storage Processor (SP) requires 4 GB per SP or a total of 8 GB per array and the Data
Mover requires 6 GB per Data Mover.

SP DIMMs
The SP CPU uses SDRAM DIMMs4. Each SP uses three 4-GB unbuffered Double-Data-Rate
3 (DDR3) type memory for a total of 12 GB per SP or 24 per DPE or array. Figure 30 on
page 36 shows an example of the location of the SP DIMM slots.

IMPORTANT
The DIMM part numbers are visible only when you remove the DIMM from the DIMM slot.
You must first take the SP out of service, disconnect any SP cables, remove the SP from the
DPE, then remove the SP power supply/cooling module from the SP (see Figure 10 on
page 14, Figure 11 on page 14, and Figure 12 on page 15). With the SP CPU laying on an
antistatic mat, lift the DIMM cover up in the SP CPU, and then remove the DIMM from the
DIMM slot. Ensure that you remove only those DIMMs that you intend to replace. For more
information about removing and installing the DIMM or memory module, refer to the
Replacing a memory module procedure available from the VNX Procedure Generator
program.


The DIMM memory is not hot-swappable. Before removing or replacing any DIMMs, you
must follow the removing and installing the DIMM or memory module procedure
described in the Replacing a memory module procedure available from the VNX
Procedure Generator program.


Note the orientation of the VNX5300 Block and File platform SP DIMMs (see locations
DIMM 0, DIMM 1, and DIMM 2 in Figure 30 on page 36). A label on the DIMM cover also
identifies the DIMM slots as DIMM 0, DIMM 1, and DIMM 2. In the VNX5300 Block and
File platform, the SP DIMMs are placed in slots 0, 1, and 2.

4. The term DIMM is used throughout this guide. The term DIMM is also referred to as a memory
module. These terms are interchangeable and basically mean the same thing.

EMC VNX5300 Parts Location Guide 35


DIMMs

DIMM 0

DIMM 1

DIMM 2

Remove / Install DIMM 1 2


DIMM 2 DIMM 1 DIMM 0

3 3
3 2
1
4

VNX-000610

Figure 30 Example of the Block and File VNX5300 platform SP DIMM slot location

36 EMC VNX5300 Parts Location Guide


DIMMs

Figure 31 shows the part number label location of the SP DIMM.

Ê100-562-264vŠ Rev : A01


P/N : 100-562-xxx ÊA01.Š

Part Number (P/N) label CNS-001540

Figure 31 Example of the Block and File VNX5300 platform SP DIMM part number location

Table 24 lists the SP DIMM part number location, description, and whether it is a FRU or
CRU.

Table 24 VNX5300 platform SP CPU DIMM part numbers

Part number label


location
(Figure 31) Part number Description FRU CRU

100-563-325 Two 4-GB Unbuffered DDR3 DIMMs 


per CPU module on one SP

Data Mover DIMMs


Data Mover DIMMs are 2-GB SDRAM type memory. Figure 32 on page 38 shows an
example of the Data Mover DIMM slot location and with a part number label. Figure 33 on
page 39 shows the part number label location.

IMPORTANT
The DIMM part numbers are visible only when you remove the DIMM from the DIMM slot.
You must first take the Data Mover out of service, disconnect any Data Mover cables,
remove the Data Mover from the DME, then remove the Data Mover power supply/cooling
module from the Data Mover (see Figure 16 on page 18 and Figure 17 on page 19). With
the Data Mover CPU laying on an antistatic mat, lift the DIMM cover up in the Data Mover
CPU, and then remove the DIMM from the DIMM slot. Ensure that you remove only those
DIMMs that you intend to replace. For more information about removing and installing the
DIMM or memory module, refer to the Replacing a memory module procedure available
from the VNX Procedure Generator program.


The DIMM memory is not hot-swappable. Before removing or replacing any DIMMs, you
must follow the removing and installing the DIMM or memory module procedure
described in the Replacing a memory module procedure available from the VNX
Procedure Generator program.

EMC VNX5300 Parts Location Guide 37


DIMMs


Note the orientation of the VNX5300 Block and File platform Data Mover DIMMs (see
locations DIMM 0, DIMM 1, DIMM 2, DIMM 3, DIMM 4, and DIMM 5 in Figure 32 on
page 38). A label on the DIMM cover also identifies the DIMM slots as DIMM 0, DIMM 1,
DIMM 2, DIMM 3, DIMM 4, and DIMM 5. In the VNX5300 Block and File platform, the Data
Mover DIMMs are placed in slots 0, 2, and 4. Slots 1, 3, and 5 are left empty.

Part Number (P/N) label

D IMM M 2
IM
D IM M 3
M 1

D IM 4
0

D IMM M 5
D IM
D

DIMM 5

DIMM 4

DIMM 3

DIMM 2

DIMM 1

DIMM 0

CNS-001766

Figure 32 Example of the Block and File VNX5300 platform Data Mover DIMM slot location

38 EMC VNX5300 Parts Location Guide


Disk-array enclosure (DAE)

Figure 33 shows the Data Mover DIMM part number label location.

Ê100-562-264vŠ Rev : A01


P/N : 100-562-xxx ÊA01.Š

Part Number (P/N) label CNS-001540

Figure 33 Example of the Block and File VNX5300 platform Data Mover DIMM part number location

Table 25 lists the Data Mover DIMM part number label location, part number, description,
and whether it is a FRU or CRU.

Table 25 VNX5300 platform Data Mover CPU DIMM part numbers

Part number label


location
(Figure 33 on
page 39) Part number Description FRU CRU

100-562-863 Three 2-GB Unbuffered DDR3 


DIMMs per CPU module on one
Data Mover

Disk-array enclosure (DAE)


The expansion disk-array enclosures (DAEs) have part numbers visible on both the front
and rear.

Front view
The DAE has two types of disk drive carriers:
◆ 3U, 15 (3.5-inch) disk drive carrier
◆ 2U, 25 (2.5-inch) disk drive carrier

3U, 15 (3.5-inch) disk drive DAE


Figure 34 on page 40 shows the front view of the 3U, 15 (3.5-inch) disk drive DAE.

Note: You can visually distinguish disk module kinds by their type, capacity, and speed
labels, and by the design of the latch and handle on each disk module (Figure 34 on
page 40).

EMC VNX5300 Parts Location Guide 39


Disk-array enclosure (DAE)

Part Number Label

VNX-000607

Figure 34 Example of the 3U, 15 (3.5-inch) disk drive DAE (front view)

Note: Figure 34 is for illustrative purposes only. The front of the disk modules may be a
little different than the ones in your particular cabinet.

Table 26 is an example of the parts available for the 3U, 15 (3.5-inch) disk drive DAE and
lists the part number label location, part number, description, and whether it is a FRU or
CRU.

IMPORTANT
Due to the extensive variety of disk module types, Table 26 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.

Table 26 3U, 15 (3.5-inch) DAE disk module part numbers

Part number label


location
(Figure 34) Part number Description (see note) FRU CRU

005049299 300 GB, 6 Gb/s SAS, 10k rpm  

005049301 600 GB, 6 Gb/s SAS, 15k rpm  

Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).

40 EMC VNX5300 Parts Location Guide


Disk-array enclosure (DAE)

2U, 25 (2.5-inch) disk drive DAE


Figure 35 shows the front view of the 2U, 25 (2.5-inch) disk drive DAE.

Note: You can visually distinguish disk module kinds by their type, capacity, and speed
labels, and by the design of the latch and handle on each disk module (Figure 35).

Part number label

VNX-000602

Figure 35 Example of the 2U, 25 (2.5-inch) disk drive DAE (front view)

Note: Figure 35 is for illustrative purposes only. The front of the disk modules may be a
little different than the ones in your particular cabinet.

Table 27 is an example of the parts available for the 2U, 25 (2.5-inch) disk drive DAE and
lists the part number label location, part number, description, and whether it is a FRU or
CRU.

IMPORTANT
Due to the extensive variety of disk module types, Table 27 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.

Table 27 2U, 25 (2.5-inch) DAE disk module part numbers

Part number label


location
(Figure 35) Part number Description (see note) FRU CRU

005049292 300 GB, 6 Gb/s SAS, 10k rpm  

005049294 600 GB, 6 Gb/s SAS, 10k rpm  

Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).

EMC VNX5300 Parts Location Guide 41


Disk-array enclosure (DAE)

Rear view
The DAE has two types of LCC modules and power supplies:
◆ 3U, 15 DAE LCC and power supply
◆ 2U, 25 DAE LCC and power supply

3U, 15 (3.5-inch) DAE LCC and power supply


Figure 36 shows the part number label location on the rear of the 3U, 15 (3.5-inch) DAE for
the LCC and power supply.

1 2

LCC B

6Gb SAS

B #
X4

6Gb SAS
X4
A #

LCC A
VNX-000605

Figure 36 Example of 3U, 15 (3.5-inch) LCC

Table 28 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 28 3U, 15 (3.5-inch) LCC part numbers

Part number label


location
(Figure 36) Part number Description FRU CRU

1 071-000-518 LCC B 400 W dual 12 V power 


supply1

2 303-108-000E LCC B 
1. The rear of the 3U, 15 (3.5-inch) DAE has the LCC power supply and LCC inverted or on top of each other. In
other words, the LCC B power supply is located on the top of LCC B. While LCC A is located on the bottom of
the DAE with LCC A on top of the LCC A power supply (Figure 36).

42 EMC VNX5300 Parts Location Guide


Disk-array enclosure (DAE)

2U, 25 (2.5-inch) DAE LCC and power supply


Figure 37 shows the part number label location on the rear of the 2U, 25 (2.5-inch) disk
drive DAE LCC and power supply.

1 2

X4
SAS
6 Gb

6 Gb
SAS
X4
#

VNX-000606

Figure 37 Example of 2U, 25 (2.5-inch) DAE LCC and power supply

Table 29 lists the part number label location, part number, description, and whether it is a
FRU or CRU.

Table 29 2U, 25 (2.5-inch) DAE LCC and power supply part numbers

Part number label


location
(Figure 37) Part number Description FRU CRU

1 071-000-541 LCC B power 400 W 12 V supply1 

2 303-104-001E LCC B2 
1. The rear of the 2U, 25 (2.5-inch) DAE has the LCC power supplies inverted or on opposite sides. In other
words, the LCC B power supply is located on the left of the DAE and the LCC A power supply is located on the
right (Figure 37).
2. The rear of the 2U, 25 (2.5-inch) DAE has the LCCs inverted or on top of each other. In other words, LCC B is
located on the top and LCC A is located on the bottom (Figure 37).

EMC VNX5300 Parts Location Guide 43


Disk-array enclosure (DAE)

Copyright © 2013 EMC Corporation. All rights reserved. Published in the USA.

Published January 24, 2013

EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
notice.

The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any
kind with respect to the information in this publication, and specifically disclaims implied warranties of
merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this
publication requires an applicable software license.

EMC2, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries.
All other trademarks used herein are the property of their respective owners.

For the most up-to-date regulatory document for your product line, go to the technical documentation and advisories
section on EMC Online Support.

44 EMC VNX5300 Parts Location Guide

You might also like