Primary voltages through 161 kV are offered, as well as a Modular Distribution Substation
full range of options in all ratings. All designs feature high
short circuit strength to withstand repeated through fault
conditions encountered in modern power systems. Kuhlman Kuhlman Electric provides Modular Distribution Substations
power transformers have a sturdy construction, are (MDSTM) by consolidating a high side circuit switcher and
compact, economical, and simple to operate and maintain. low side switchgear onto the transformer, reducing the overall
They have exceptionally good service records under all types substation costs as well as the space required for the
of applications and loading conditions. substation.
Designs have been optimized to incorporate the best The MDS TM combines Powell Electrical Manufacturing
materials, processing and design concepts for any given and S & C Electric to provide the complete modular
transformer rating and service requirement. substation. The switchgear is available in 5 through 15 kV,
1,200 through 4,000 amp ratings, and in 27 and 38 kV,
1,200 through 2,500 amp ratings.
1
Power
Transformers
Power Transformers
Power transformers with or without load tap changing through
37.5/50/62.5 MVA,161 kV
Cores
Kuhlman power transformers are designed with mitered,
step-lapped joints providing high mechanical strength and
optimum magnetic performance. Individual laminations are
accurately cut to size and mitered for each core design.
The combination of premium steel and optimum construction
provides Kuhlman power transformers with low core losses
and quiet operation.
Windings
All Kuhlman power transformer windings are cylindrical
construction for maximum short-circuit strength. High voltage
windings are continuous wound disk type. Low voltage
windings are generally multi-strand, disk or helical type. All
Tank
windings are designed to withstand repeated through fault
conditions.
Tanks
Transformer tanks are all-welded steel construction and
provide a compact, rugged enclosure for the core and coils.
All tanks are designed for full vacuum processing and filling.
Lifting lugs near the top corners permit lifting of completely
assembled transformers. Horizontal tank braces have sloped
tops to shed water, repel dirt, and help minimize corrosion.
2
De-energized Tap Changer
Kuhlman self-aligning no load tap changers
assure good electrical connections at all times.
The de-energized tap changer handle is
mounted at a convenient operating height,
normally on the end of the tank. The operating
handle is simple to operate, snaps into
position, and has provisions for padlocking.
• Operations counter
3
Power
Transformers
Control Cabinet
Self-Cooled, Class OA
All Kuhlman power
transformers have a self-
cooled rating. Flat panel
radiators are used as the
cooling surface in
addition to the main tank Motor driven Fan
surfaces. Radiators are
either bolted on with
individual shut-off valves
or welded directly to
the tank. Radiator
configuration is orderly,
compact and designed to
provide the best cooling
efficiency in the least
amount of space.
4
Sealed Tank Oil
Preservation
Sealed tank oil preservation systems
are standard on all Kuhlman power
transformers. The gas space over the
oil is sufficient to allow for oil
expansion over the entire range of
operating temperatures. A pressure
vacuum gauge is provided to monitor
the pressure inside the tank. A self-
sealing pressure relief device is
provided on the transformer cover to
vent excessive pressures that may
develop during abnormal or fault
Sealed Tank
conditions.
Air Bladder
Conservator Oil
Preservation System
(option)
The air bladder conservator oil
preservation system provides a
reservoir of oil above the main tank,
along with expansion space. This
system keeps the main tank
completely full of oil under all
operating conditions.
Inert Gas System
5
Power
Transformers
6
Modular Distribution Substation TM
(MDS TM)
Kuhlman Electric provides Modular Distribution Substations The circuit switcher provides reliable, economical switching
by consolidating a high side circuit switcher and low side and protection. The circuit switcher's simple straightforward
switchgear onto the transformer, reducing the overall design means fewer parts, lower initial costs and lower
substation costs as well as the space required for the operating cost.
substation.
Modular Distribution Substations offer many advantages;
Kuhlman has partnered with Powell Electrical lower total overall substation costs, less installation time
Manufacturing and S & C Electric to provide the complete and expense, and dramatically reduced real estate
modular substation. The MDS is available up through 37.5 and space requirements.
MVA base rating, 138 kV, with or without load tap
changers.