RASplus DVR Software User Guide PDF
RASplus DVR Software User Guide PDF
Administration System)
Digital Video Recorder Software
User Guide
A 09/09 New document based on 900.0857 rev 6.00 with updates for V1.4.4 to
include HRXDS.
B 09/09 On page 12, updated p/n of HRSD user guide and corrected HRXDS16
model name.
2
Contents
Contents
About This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Overview of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Package Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installing RASplus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
RASplus Viewing Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
RASplus Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Remote Sites Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Favorite Sites Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Status View Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Search View Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Map Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Color, PTZ, and Alarm Out Control Panels . . . . . . . . . . . . . . . . . . . 31
Image Processing Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Emergency Event View Panel . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Watch Event View Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Report View Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
RASplus Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
System Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
View Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Remote Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Favorite Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Sequence Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Record Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Image Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Layout Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Help Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Live Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Screen Layout and Frame Layout . . . . . . . . . . . . . . . . . . . . . . . . 60
Audio Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Sequence Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Playback and Search . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Search View Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Search Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Additional Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Additional Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Panic Recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Status View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Function Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Status Display Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
4
Figures
Figures
Figure 2-1 Select Installation Folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 2-2 Welcome to RASplus Setup Wizard . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 2-3 RASplus Ready to Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 2-4 Run RASplus Automatically Option . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 2-5 RASplus Language Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 2-6 RASplus Exit Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 2-7 Welcome to MSXML Setup Wizard. . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 2-8 MSXML End-User License Agreement . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 2-9 MSXML Customer Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 2-10 MSXML Choose Setup Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 2-11 MSXML Exit Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 3-1 RASplus Viewing Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 3-2 Four Position Arrow Icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 3-3 Four Position Arrow with Tab Icon . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 3-4 Remote Sites Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 3-5 Favorite Sites Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 3-6 Status View Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 3-7 Search View Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 3-8 Map Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 3-9 Map Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 3-10 Map Popup Options Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 3-11 Color, PTZ and Alarm Out Control Panels . . . . . . . . . . . . . . . . . . . . . . 31
Figure 3-12 Image Processing Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 3-13 Emergency Event View Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 3-14 Watch Event View Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 3-15 Report View Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 3-16 RASplus Menu Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 3-17 System Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 3-18 Setup Screen — System 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 3-19 Drawing Mode Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 3-20 Recording Mode Setup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 3-21 Setup Screen — System 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Figure 3-22 Event Setup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Document 800-05056 Rev C 5
11/09
Figures
6
Figures
8
Tables
Tables
Table 4-1 Camera Popup Menu Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Table A-1 Clip Player Menu Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Table 4-5 Save Clip Images Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Table C-1 Property Tab Device Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Table C-2 Property Tab Device Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
10
About This Document
This document introduces the Remote Administration System Plus (RASplus) software
designed for the digital video recorder (DVR) and describes the procedures for
operating and maintaining the software.
Overview of Contents
Related Documents
For more information about topics that are relevant to the subject of this manual, see
the documents listed below.
12
Overview
1
Overview
Features
Product Information
Package Components
System Requirements
Playing back digital video puts a high demand on your computer system. To use the
RASplus video monitoring and playback functions, your personal computer (PC) must
meet the minimum system requirements listed below:
• Operating System: Microsoft Windows XP x86 (32 Bit) or Microsoft Windows Vista
x86 (32 Bit)
• CPU: Intel Pentium IV (Celeron) 2.4 GHz or faster
• RAM: 512 MB or higher
• VGA: AGP, Video RAM 8 MB or higher (1024x768, 24 bpp or higher)
14
Installation
2
Installation
Installing RASplus
Note The User Account Control window might appear when using
the Microsoft Windows Vista operating system. Click Allow and
install RASplus software following the instructions.
3. The .NET Framework and the Visual C++ Runtime Libraries are installed
automatically.
4. Designate the folder path to install RASplus and select the user(s) who can use
RASplus, then click Next.
16
Installation
6. Click Next.
7. Select whether or not to run RASplus automatically when logging onto Windows,
and then click Next.
8. Set the language option by selecting either Select language when starting
RASplus or Always start RASplus using the language below. If you select to
Always start RASplus using the language below, select the desired startup
language from the list of available languages and then click OK.
9. When Figure 2-6 appears after finishing the RASplus installation, select the Install
MSXML check box and click Finish. Installing the MSXML application is required
for RASplus to initiate.
18
Installation
11. Select I accept the terms in the License Agreement, and click Next.
20
Configuration
3
Configuration
After installing the RASplus software, the RASplus shortcut icon ( ) is on your
desktop. Double-click the icon to run the RASplus program. The RASplus program
consists of the viewing screen, 12 docking panels, menus and toolbar.
Note Some panels do not display on the screen in the default frame
layout. To display those panels, go to the View menu at the top
of the screen, then select each panel from the menu.
22
Configuration
The Viewing screen displays images from selected cameras in live monitoring or
playback mode. RASplus provides various multi-screen layouts; single-screen, quad,
1+7, 3x3, 4x4, 5x5, 1+32, 6x6, 7x7, 8x8 and full-screen.
Note In the event that screen updates are slow when using the
Microsoft Windows Vista operating system, try disabling the
AutoTuning capability of your computer. This might resolve the
problem.
RASplus Panel
RASplus has many powerful tools that can be used to streamline your work. Most of the
tools are located on 12 docking panels that can be placed on the screen where they are
most convenient. You can keep your screen free of clutter by displaying only the panels
you use most frequently.
Click in the upper right corner of a panel to enable the auto-hide feature. Tabs for
auto-hidden panels are displayed on the side of the screen.
Scrolling over an auto-hidden panel tab will cause the panel to fly out. You can cause
the panel to lock back into its original display position by clicking .
Click to hide the panel without a tab. Hidden panels can be displayed by selecting
them from the drop-down menus.
Panels can be resized, moved, and combined with other panels to create a workspace
that fits your needs. To resize a panel:
1. Scroll the cursor over the edge of the panel until the cursor changes to or .
2. Then click the left mouse button and drag the panel border to enlarge or reduce
its size.
You can also move a panel so that it is associated with another panel:
1. Drag the panel over the panel you want it associated with, and the icon with four
position arrows will center over that panel.
24
Configuration
2. Scrolling the cursor over the icon arrows will cause a transparent blue box to
display where the panel will be located.
3. If you are satisfied with the position, release the left mouse button and the panel
moves to its new position.
It is possible to combine panels so that they take up less space on the screen.
Combined panels have a row of tabs across the bottom. Clicking a tab brings that panel
to the foreground. To combine panels:
1. Move the cursor to the title bar of the panel you want to move.
2. Click and drag the panel onto the panel you want to combine it with. If they can be
combined, the four-position arrow icon will have a tab symbol in the center.
3. Drag the cursor over the tab symbol , and a new tab appears on the panel.
4. Release the mouse button to combine the panels.
The layout possibilities are virtually unlimited. With a little experimentation you will be
able to lay out the RASplus screen so that it best meets your requirements.
The Remote Sites panel displays a list of remote sites registered during RASplus
System setup and a list of installed cameras at each remote site. To find the remote site
easily in the Remote Sites list, enter the site name in the query box, and click .
1. Select the site or camera you want to connect to from the list.
2. Drag and drop the site or camera in the desired position on the screen or the
Status View panel.
3. The screen displays images from selected cameras, and the Status View panel
displays the system status information of the connected remote site.
The Favorite Sites panel displays the list of Favorite sites registered during RASplus
System setup. Selecting the Favorite site you want to connect to from the list and then
dragging and dropping it in the desired position on the screen automatically connects
all the remote sites registered in the Favorite site.
26
Configuration
The Status View panel displays the event, alarm out, system check and recording
status information of the connected remote site in real-time. To connect to the remote
site, select the site or camera you want to connect to from the Remote Site or Map panel
and then drag and drop it into the Status View panel. See Status View, page 78, for more
information about the Status View panel.
Use the Search View panel to perform time-lapse or event searching of recorded data
on the remote DVR. See Search Mode, page 66, for more information.
Map Panel
The Map panel allows for efficient monitoring of the remote sites by displaying a
three-dimensional map of the selectable site:
1. Click the right mouse button on the map panel to select the map image file (.rmp)
you want to monitor from the list. The selected map image displays in the Map
panel and the sites registered on the map image file will be connected.
2. When the selected map is linked with sub-maps, click the linked image to move to
the sub-map.
28
Configuration
Note See Appendix C, Map Editor for instructions for editing maps.
The Map panel pops up another screen when alarm-in, motion or video loss events are
detected or when you click the device icon according to the Map Editor settings.
• x0.25 to x2: Sets the desired size of the Map popup screen.
• Full Screen: Enters the full-screen mode of the Map popup screen.
• Transparency...: Adjusts the transparency of the popup screen.
• PTZ Set...: Controls pan, tilt and zoom of the selected PTZ camera.
• Disable Time Out: Continues to display the popup screen when events are
detected by disabling the Dwell Time Out.
• Original Ratio: Displays the Map popup screen in its original aspect ratio.
• Antialiasing Screen: Enhances image display quality on the popup screen
by eliminating staircase (aliasing) effects on the enlarged image.
• User Set…: Sets the mode of the current popup screens displayed on the
monitor. For example, the monitor displays the current popup screen with
enough frames for 16 cameras when you select 4x4.
Note See Device Setting on page 95 for more information about the
popup function.
30
Configuration
Place the mouse cursor on the device on the map to display the device status. When
the device detects any event or the device is not working properly, the following status
icons appear (maximum of 4).
Unplugged Motion
Event off Alarm In
Irregular Alarm Out
Video Loss
1. Click the right mouse button on the Map panel to open a text menu screen.
2. Select Watch Event View from the menu to display the event information for the
connected remote sites.
3. Select Close to disconnect the current connection on the Map panel.
These three panels in Figure 3-11 allow color control, PTZ control and alarm out control
while live monitoring a remote site. See Live Monitoring on page 59 for more details.
The Image Processing panel allows you to enhance played back images. See
Playback and Search on page 64 for more details.
The Emergency Event View panel displays a list of events (preset for notification at the
remote site) that were called from individual remote sites (LAN connection only).
Select an event from the list, then drag and drop it in the desired position on the Watch
or Search screen to connect to the remote site. A check mark appears in the box at left.
Viewing Tooltips
Select an event or site from the list, then click the right mouse button. A tooltip appears
which contains the emergency event instructions from the remote site.
32
Configuration
Note The Emergency Event View function is available only for the
remote sites that were set to notify the RASplus system when
configuring each event setup.
The Watch Event View panel displays events detected at individual remote sites while
RASplus is in the live monitoring mode. The description of event icons is as follows:
The Report View panel displays the system status information of remote sites. RASplus
checks the remote site and reports system status. Report Setup must be configured
during RASplus System setup for this feature to function. See System Menu on page 35
for more details.
RASplus Menus
34
Configuration
System Menu
Setup
The Setup screen allows setting up the system operation and remote site configuration.
System 1 Tab
Set up the date/time format for RASplus, display options, and panic recording function.
Display Option Set up the screen display, drag & drop popup option, display
acceleration and OSD.
• Screen Option: Select Watch Screen to use RASplus for live monitoring only,
Search Screen to use RASplus for searching only, or Watch and Search Screen
to use RASplus for both live monitoring and searching. Select Hide the Message
Box to hide the message box that displays the status information about RASplus
and remote site connections.
• Drag & Drop Popup Option: Select which mouse button will be used when
displaying popup menu screens from Use Left Mouse Button, Use Right Mouse
Button or both (Watch and Search Screen mode only).
• Drawing Mode Setup...: Set up the display options for the screen.
36
Configuration
Note While in the Fast Drawing mode, the drawing speed might
decrease when the RASplus screen is not located on the primary
monitor.
Note With some computers, the image drawing speed might decrease
while using a deinterlace filter, depending on the type of
deinterlace filter.
Note With some computers, the image drawing speed might decrease
when the Anti-Aliasing Screen option is selected.
• OSD Setup…: Select options (Title, Time Info, Date Info, Text-In and Overlay
Text-In Data) to display on the screen.
• Load Default Map at Startup: Select whether or not the user-defined map file is
loaded automatically when RASplus starts, and designate the path of the map file
(.rmp) to load.
Recording Setup Set up the use (On or Off) of the panic recording function and
overwriting option of the recording folder (On or Off). When using the panic recording
function and overwriting option, RASplus continues recording when the hard disk drive
is full by overwriting the oldest video. Designate a recording folder path and set the
recording folder size from 640 MB to 2048 MB. Capacity shows the remaining space of
the recording folder.
Note The recording folder size cannot be changed once it has been
set. Designate another recording folder path if you want to
expand the recording space.
Note Panic recording will NOT be made for the cameras not currently
displayed on the Watch screen even though they are set up to
be recorded.
Note When selecting the User Assignment Setup mode, the user can
manually assign camera channels to record on the Watch
screen. Select a camera on the Watch screen and click the right
mouse button, then select Select Record Camera in the text
menu screen. The gray icon displays on the selected camera
screen.
38
Configuration
System 2 Tab
Set up the modem connection information for remote access, system password,
network option, report function and DVRNS server.
Dial-up Network Select Use Modem if you want to use a modem for remote access.
Network Option Set up the IP port number (from 8000 to 12000) that is used for
network connection when receiving a callback message from a remote site.
Note The IP port number you enter should match the value set during
the network setup of the remote DVR.
Event Setup Enter the number of emergency events that are displayed in the
Emergency Event panel. Set up RASplus to sound when events are detected by
selecting events from the list and designating the sound file (.wave) path. You can set
up a different sound for each type of event.
Report Setup Set up the use (On or Off) and check intervals (from 1 to 24 hours) of the
report function. When using the report function, RASplus checks on the remote site
based on the user-defined interval and reports system status.
DVR Name Service Set up the IP address and port number (from 10000 to 12000) of
the DVRNS (DVR Name Service) server. The IP address and port number you enter
should match the values set during the DVRNS setup of the remote DVR you want to
connect to.
40
Configuration
Add Click Add and enter the information about the remote site you want to add.
use the following values: 8200 for Admin, 8016 for Watch, 10019 for Search,
and 8116 for Audio. Select the number of cameras at the remote site. For
example, selecting 8 from the list when registering a 16-channel DVR displays
video of the first 8 channels on the screen.
• Login Setup: Enter the user ID and password of the remote site to be accessed. If
you have entered a user ID and a password, the site will be connected
automatically without a dialog box requesting a password. Select No Password
for remote systems that do not require a password (for example, guest login).
Emergency Event Instruction Enter the message that displays when emergency
events are called in from the remote site. The Emergency Event Instruction can be
checked by clicking the right mouse button after selecting the event or the site from the
list in the Emergency Event panel.
Change Select the group or site you want to edit and click Change, or double-click the
group or the site to change. Edit the site information.
Remove Select the group or site you want to remove and click Remove.
Find Enter the group or site name to search for and click Find to display the matching
groups or sites in the list.
The Favorite Site is a user-defined connection list that combines more than one remote
site so that multiple sites can be monitored at the same time with a single connection.
Add a new Favorite Site and define it by dragging and dropping sites and/or cameras
to the Favorites map. Up to 64 cameras can be monitored at a time when each camera
is assigned to its own position on the Favorites map.
42
Configuration
Site Name Select a registered Favorite site from the drop-down list.
Change Select the Favorite site to change from the Site Name list and click Change.
Then change the site name or screen layout.
Remove Select the Favorite site to remove from the Site Name list and click Remove.
Connect Favorite Site at Startup Select whether or not your favorite site is
automatically connected when RASplus starts.
Remove Selected Camera Removes selected cameras from the Favorites map.
Cameras can also be removed by clicking the right mouse button after selecting the
camera.
Remove All Cameras Removes all cameras from the Favorites map.
Note [W] (Watch Screen) and [S] (Search Screen) displayed to the left
of the camera number indicates the display option of each
camera. The display option can be selected when registering a
Favorite site. Selecting the remote site from the Group List and
dragging and dropping it to the Favorites map using the right or
left mouse buttons (this is user-defined and must be set during
system setup) displays the text menu screen. Select the desired
displays option between Watch Screen and Search Screen. If
you do not select the display option, Watch Screen display will
be assigned to all cameras of the registered Favorite site by
default.
Note Click on the toolbar to save the current screen layout of the
Watch screen or Search screen directly to the Favorite site.
Note The Favorite Site list does not function with modem connections.
Configure the sequenced sites. RASplus connects to the registered sites sequentially
allowing connection to more than one remote site.
44
Configuration
Sequence Dwell Time Adjust sequence intervals (from 5 seconds to 1 hour) for each
connection.
Add Select the site to add from the Group List and click Add.
Add All Adds all sites in the Group List to the Auto Sequencing list.
Remove Select the site to remove from the Auto Sequencing list and click Remove.
Note The Auto Sequencing list is not valid with modem connections.
Allows applying the settings of the System Setup menu saved as an .xml file format to
the RASplus system. Click on the toolbar.
Saves the current settings of the System Setup menu as an .xml file format. Click on
the toolbar.
Multiple DVRs can be upgraded or set up using the Batch Job Setup screen.
Upgrade Tab
Add Select the site to add from the Group List and click Add.
Add All Adds all sites in the Group List to the Upgrade Sites list.
Remove Select the site to remove from the Upgrade Sites list and click Remove.
46
Configuration
Setup Tab
Add Select the site to add from the Group List and click Add.
Disconnect
Disconnects all current connections. You can also click on the toolbar.
View Log
Note You can also display the Log Viewer screen by selecting Log
Viewer from the RASplus options under the Start menu in
Windows.
Select a log type from the list to display all entries of that log type.
Search Time Set the time range to search within. Select Current Time and the desired
period to search for logs from the current time to as far back as the selected timespan.
Select Detail Time to set up a specific start and end time for the search.
48
Configuration
Detail Condition Set the desired search parameters. Select a filter target from the
second list, and select a filter from the third list (enter a filter in the text box). Then select
a comparison operator from the last list:
• Equal to search for logs that satisfy the condition (case sensitive)
• Not Equal to search for logs excluding logs that satisfy the condition
• Like to search for logs that include the entered keyword
• Not Like to search for logs that do not include the entered keyword
Search Displays log entries that satisfy the current search filter.
File
• Log File Open: Opens a log file (.db).
• Delete Log: Deletes logs older than a certain age.
• Save As…: Saves the log information in the list as a text
or CVS file.
• Print: Prints the log information.
• Close: Closes the Log viewer screen.
Exit
View Menu
Remote Menu
Note The Remote menu can also be activated by clicking the right
mouse button after selecting the remote site on the Remote Sites
panel.
Remote Setup
Remote Setup can be used to change the setup of a remote DVR. Select the remote
site on the Remote Sites panel, initiate the Remote Setup menu, and the setup screen
displays.
Note Refer to the user manual for the remote DVR for more details on
system setup.
These selections display the system log and event log information of a remote DVR. Set
the time range of interest and click Find. The log entries within the time range display
on the list. 100 results can be displayed in a single page. Click the Move buttons to
display additional results.
50
Configuration
From Adjust the search starting date and time. When First is selected, it will search
from the first logged item.
To Adjust the search ending date and time. When Last is selected, it will search to the
last log.
Find Displays remote log entries within the selected time period.
Save... Saves the log information as a text or CSV file (UTF-8 encoded).
Move Buttons Moves to the first page ( ), previous page ( ), next page ( ) or last
page ( ). You can also go directly to a log page by clicking the corresponding page
number.
Favorite Menu
Note The Favorite menu can also be accessed using the toolbar
controls.
Sequence Menu
Note The Sequence menu can also be accessed using the toolbar
controls.
Record Menu
Note The Record menu can also be accessed using the toolbar
controls.
Starts or ends panic recording. Selecting Record Play initiates the Record Player
program and plays recorded video. See Panic Recording, page 77, for more details.
52
Configuration
Image Menu
Note The Image menu can also be accessed using the Image
Processing panel controls and the toolbar controls.
Note See Live Monitoring on page 59, and Playback and Search on
page 64, for more details.
Layout Menu
Note The Layout menu can also be accessed using the toolbar
controls.
Screen Layout
Layout Change Select the desired screen layout using the Layout Change menu.
When changing the screen layout, the selected camera on the current screen will be
located in the first cell of the new layout.
Full Screen Selecting Full Screen enters the full-screen mode, and returns to the
previous screen mode by pressing the Esc key on the keyboard or selecting Full
Screen Close (x) from the popup menu displayed by clicking the right mouse button.
Frame Layout
Layout Load Select the desired frame layout and click Load to apply the selected
frame layout to RASplus.
54
Configuration
• Default Layout: Displays the panels that are used most frequently in the Watch
and Search screen modes.
• Admin Layout: Displays only the panels that are used most frequently in the
Admin screen mode.
• Full Layout: Displays all the panels.
• Hide Layout: Hides all panels and displays only the screen.
• User Defined Layout: Displays the user-defined layout.
Layout Setup The user can configure the frame layout by displaying panels on the
screen where they are most convenient. Set up the user-defined frame layout.
• Always Load Layout at RASplus Startup: Select whether or not the selected
frame layout loads automatically when RASplus starts.
• Save: Enter a layout name and click Save to save the current frame layout as a
new user-defined layout.
• Rename: Select the layout from the Layout List and click Rename. Then change
the layout name.
• Delete: Select the layout to delete from the Layout List and click Delete.
Help Menu
Toolbar
56
Configuration
Select the desired screen layout using the layout toolbar. When changing the screen
layout, the selected camera on the current screen will be located in the first cell of the
new layout. When in one of the multi-view formats, click or to move to the
previous or next page.
Click (Layout Load) to apply the selected frame layout to RASplus, and click
(Layout Setup) to set up the user-defined frame layout.
58
Operation
4
Operation
Live Monitoring
RASplus provides remote monitoring functions for viewing video images in real time
from either a single site or multiple sites. In addition, when events are detected at a
remote site while in the live monitoring mode, RASplus displays the event information
on the Watch Event View panel. In order to perform live monitoring, the display option
must be set to Watch Screen or Watch and Search Screen during System setup.
To connect a remote site on the Watch screen, select the site or camera you want to
connect to in the Remote Site, Favorite Sites, or Map panel and then drag and drop it
in the desired position on the screen. The icon displays on each Watch screen.
To disconnect the current connection, select in the Remote Sites, Favorite Sites, or Map
panel the site or camera you want to disconnect, then click (the disconnect button)
on the toolbar, or select Disconnect from the System drop-down menu.
Note Some DVR models will only transmit images to the RASplus
system while recording video.
Note When selecting the display option of Watch and Search Screen
during System setup, the remote site can also be set to connect
using the right or left mouse buttons (this is user-defined and
must be set during System setup). Select Watch Screen to
connect to the selected site on the Watch screen when the
following text menu screen appears.
RASplus provides multiple screen layout options. The formats available are
single-screen, quad, 1+7, 3x3, 4x4, 5x5, 1+32, 6x6, 7x7, 8x8 and full-screen. When in
one of the multi-view formats, clicking or will move to the previous or next page.
To view a specific image in the single-screen mode, move the cursor to that image and
double-click the left mouse button. To return to the previous screen mode from the
single-screen mode, double-click the left mouse button in the monitoring window.
Clicking (Layout Load) will apply the selected frame layout to RASplus, and clicking
(Layout Setup) allows you to set up the user-defined frame layout.
Audio Communication
RASplus supports audio communication between the RASplus system and a remote
site that is equipped with two-way audio. If you want to enable communication with a
remote site that supports two-way audio, then select any camera from the remote site
on the screen and click the right mouse button.
Select Enable Audio from the menu to display the following audio control panel.
60
Operation
To send audio to the selected remote site, click and speak into the microphone.
To monitor live audio from the selected remote site through the attached speaker, click
.
Only DVRs that support remote two-way audio allow you to select an audio channel to
monitor from the RASplus system.
Note To verify if two-way audio is supported, check the user guide for
your DVR.
Sequence Monitoring
Click on the toolbar to sequentially connect to the registered sites. This allows for
connection to more than one remote site and for the display of images from selected
cameras.
For sequence monitoring to function, the sequence sites should be registered during
System setup. See Sequence Monitoring on page 61 for details on configuring the
sequence site.
Color Control
Adjust the brightness, contrast, saturation and hue of live video for each camera by
clicking the corresponding buttons on the Color Control panel. Clicking cancels the
image processing operation and reloads the original image. Only the administrator can
adjust the image through RASplus.
Note Not all DVRs support color control through RASplus. Refer to the
user manual for your DVR.
PTZ Control
Select a PTZ camera at the remote site, and control pan, tilt and zoom operations. Only
the administrator can control a PTZ dome through RASplus. The icon will display on
each camera screen on which a PTZ can be controlled remotely.
62
Operation
Note PTZ control using the mouse is supported. Click the left mouse
button on the image drag the mouse to move that image in the
direction you want. Roll the mouse wheel to zoom in or out.
Note Not all DVRs support the PTZ control through RASplus. Refer to
the user manual for your DVR.
Control alarm out devices on the remote DVRs by clicking the ON or OFF buttons. Only
the administrator can control an alarm out through RASplus.
Note Not all DVRs support the Alarm Out control through RASplus.
Refer to the user manual for your DVR.
RASplus allows you to play back and search recorded images on remote DVRs. It also
provides additional functions including zoom, various image enhancements, image
saving and printing. To use remote playback and search functions, the display option
must be set to Search Screen or Watch and Search Screen during System setup.
To connect to a remote site on the Search screen, select the site or camera you want
to connect to in the Remote Site or Favorite Sites panel and then drag and drop it in the
desired position on the screen. The icon will be displayed on each Search screen.
The remote site connection on the Search screen will automatically be disconnected if
there is no activity for a specified time. Click on the toolbar or select Disconnect from
the System drop-down menu to disconnect the current connection manually.
Note When selecting the display option of Watch and Search Screen
during System setup, the remote site can be also be set to
connect using the right or left mouse buttons (this is
user-defined and must be set during System setup). Select
Search Screen to connect to the selected site on the Search
screen when the following text menu screen appears.
It is possible to display cameras in both the Watch Screen mode (live view) and Search
Screen mode at the same time. For example, you can connect to a remote DVR site with
nine cameras. Drag and drop the site into the first frame on the viewing screen and
64
Operation
select Watch Screen. Live video will display in the first nine frames on the screen. Then,
drag and drop the site into the 10th frame on the viewing screen and select Search
Screen. You will be able to view any video recorded on the remote DVR in frames 10
through 18.
The Search View panel consists of playback and search controls, a time-lapse search
table, and an event search table. The playback buttons on the Search View panel
perform the following functions:
You can control the playback speed of images that are currently being played back by
using the control slider.
You can control the fast forward or fast backward playback speed of images that are
currently being played back fast forward or fast backward by using the
control slider.
You can enlarge a specific part of the image up to five times using the
control slider.
The user can electronically pan and tilt within the enlarged image by dragging the
image using the mouse. Click the left mouse button on the enlarged image and drag to
move its position. Click the button to cancel the enlargement and reset the image.
You can change the brightness of the current image using the control
slider. Click the button to cancel the brightness changes and reset the image.
Note Zoom in/out and brightness control work only while the image is
paused.
Search Mode
RASplus supports two search modes: time-lapse and event. The time-lapse search
mode searches for recorded data by time and date and then plays back images found
within the time parameters. The event search mode searches for event log entries using
specific conditions and plays back the images associated with those event entries.
These two modes have different panel configurations and search methods.
Note You cannot use both search modes at the same time.
Time-Lapse Search
1. Click on the Search View panel to enter the time-lapse search mode.
66
Operation
2. Selecting a date from the calendar initiates the time-lapse search. This also
enables dates with available recorded images.
When first entering the time-lapse search, the latest date with recorded images will
be selected (highlighted) in the calendar.
3. Click (Reload) to reload the date information. Recorded information available
from the selected date will be displayed on the timetable.
The recorded data for all cameras is displayed by time in one-hour segments and
bar-shaped segments indicate that there is recorded data during that time.
4. Select a specific hour by clicking the mouse on the desired hour segment. Video
images will be played back starting with the first image captured within the
one-hour segment. A yellow-highlighted segment indicates the selected time that
will be played back.
Choosing a Segment
If the remote DVR’s time and date have been reset to a time that is earlier than some
recorded video, then it is possible for the DVR to have more than one video segment in
the same time range.
Click (the Segment button) and select the video segment you want to search. The
active segment is highlighted with pink, and the inactive segment is highlighted with
gray on the timetable.
The recorded data for each camera channel is displayed by time in one-minute
segments and a red vertical line indicates the selected time that will be played back.
The color of the bar indicates different types of recording:
• Yellow = Pre-Event
• Purple = Event
• Red = Panic
• Blue = Time-Lapse
If the DVR has more than one video segment in the same time range, each segment will
be separated by a yellow vertical line.
To view an image at a specific time, click , the Go To button and set up the date and
time to search.
Event Search
1. Click on the Search View panel to enter the event search mode.
2. Click .
3. Set up the search condition in the Event Search dialog box (Figure 4-13).
68
Operation
Note The Event Search dialog box will differ depending on the
specifications of the remote DVR.
Note The Text-In (Event Search - Text-In tab) search might not be
supported, depending on the specifications and version of the
remote DVR.
4. Set up the search criteria for the event search in the Event Search dialog box, and
click Find.
Note When First is selected for the search starting time, the search
will be from the first recorded data. When Last is selected for the
search ending time, the search will be to the last recorded data.
5. The results will be displayed in the event list. A total of 100 results can be
displayed at a time.
6. Click (Query Next) to display the next 100 results.
7. Select an event in the list to play back the recorded data associated with that
event. The images may be played back using the playback buttons.
Event Search offers the capability of searching for video associated with text.
Note If it is desired to view the video with text overlay, ensure that
Overlay Text-In Data is enabled when setting up RASplus
(System menu ➤ Setup ➤ System 1 ➤ OSD Setup ➤
Overlay Text-In Data).
1. Enter video search criteria based on text strings in the Event Search Text-In dialog
box (Figure 4-15).
Note The Column and Line fields can be used for more specific
searches of text-in data. Column (0–80) is used to identify a
desired number location within multiple columns of numbers.
Line (0–5) is used to search for desired data in a line below the
text string that is entered into the Name field. When Line = 0, the
search criteria will be based on the numerical value found in the
same line that the text string content is found.
7. Designate the location of the comparison value in the Column and Line fields.
8. After you set your desired search conditions, click Find to display the search
results.
Additional Functions
Click on the Search View panel to set up the data source to be searched.
70
Operation
Search on Local Searches the recorded data on the primary storage installed in the
DVR.
Search on Archive Searches the archived data on the backup storage installed in the
DVR.
Search on Other Searches recorded or archived data on storage used for another
DVR then installed in the selected remote DVR.
RASplus provides multiple screen layouts for playback. The available layouts are
single-screen, quad, 1+7, 3x3, 4x4, 5x5, 1+32, 6x6, 7x7, 8x8, and full-screen. When in
one of the multi-view formats, clicking or will move to the previous or next page.
To view a specific image in the single-screen mode, move the cursor to that image and
double-click the left mouse button. To return to the previous screen mode from the
single-screen mode, double-click the left mouse button in the playback window.
Clicking (Layout Load) will apply the selected frame layout to RASplus, and clicking
(Layout Setup) allows you to set up the user-defined frame layout.
Image Processing
The Image Processing panel allows enhancing played back images using processing
controls.
RASplus will play audio when it is in the single-screen layout while playing back
recorded video that has recorded audio.
Click the right mouse button on the screen. A menu displays. Select Enable Audio from
that menu to turn audio playback On and Off.
Save
Save as Self-Player… Saves any video clip of recorded data as an executable file.
1. Set up the save parameters in the following dialog box.
72
Operation
Note When more than one video segment exists in the same time
range due to time overlap, a segment selection dialog box
appears, prompting you to select the video segment you want to
save from the segment list. Refer to the user manual that came
with the remote DVR for details on time overlap.
Note When the data file reaches 2 GB, you are prompted to continue
saving by creating multiple files in 2 GB units. If you do not want
to be asked, select Don’t ask about file limit.
Save As Video… Saves any video clip of recorded data in an AVI (Audio Video
Interleaved) file format.
1. Click Save As Video. The Save As Video screen appears.
Note Select Include Audio Data to include audio when saving video
with recorded audio. This option is not available when more than
one camera is selected.
Note When the data file reaches 2GB, saving stops. Select Limit File
Size and adjust the maximum file size to stop saving when the
data file reaches the maximum file size setting. Select Save Split
File to save video by creating multiple files in 2GB units or in the
Max File Size units.
74
Operation
Additional Functions
Save
Click on the toolbar to save the current image as a bitmap or JPEG file. If you place
a checkmark in the box beside Include Image Info, then the text information about the
site will be included when the image is saved.
Click on the toolbar to print the image currently displayed on the screen on a printer
connected to your computer. By placing a checkmark in the box beside Include Image
Info, text information about the site will be included when printing the image.
Screen Menu
Select a camera on the Watch or Screen screens and then click the right mouse button
to display the popup menu.
Option Function
Change Camera Changes the camera name that displays on the screen. If
Title you leave the Camera Title blank, then the camera name
remote setup appears. Changing the camera title does
not affect the camera name that was set up on the remote
site.
Enable Audio Enables audio communication with the remote site on the
Watch screen (Two-way audio equipped remote sites
only). Plays audio while playing back, on the Search
screen, recorded video that has recorded audio. See Live
Monitoring on page 59 and Playback and Search on page
64 for more information.
Aspect Ratio Changes the image aspect ratio that is displayed on each
camera screen.
Set Record Camera Sets the selected camera channel to be recorded during
panic recording. See System Menu on page 35 for
information on configuring camera channels for panic
recording.
Anti-Aliasing Screen Enhances image display quality for all cameras on the
screen by eliminating stair-stepping (aliasing) effects in
the enlarged image.
Note With some computers, the image drawing speed might decrease
while using a deinterlace filter, depending on the type of
deinterlace filter.
76
Operation
Note With some computers, the image drawing speed might decrease
when the Anti-Aliasing Screen option is selected.
Panic Recording
Clicking on the toolbar starts panic recording of cameras currently displayed on the
Watch screen. Clicking the button again stops panic recording. Up to 16 channels can
be recorded at a time, and you can select which cameras are to be recorded during the
System setup. Clicking on the toolbar initiates the Record Player program and plays
video saved in the recording folder designated during the System setup. The Record
Player GUI and its controls are almost identical to the Clip Player. Refer to Appendix A,
Video Clips Review for more details.
If you want to play back video saved in another recording folder, run the Record Player
program first. Move to the Start menu in Windows. Then, select Record Player from the
RASplus options and select the recording folder path you want.
Recorded video can be saved in a bitmap or as an executable file using the save
function of the Record Player.
Note Panic recording will be available only if you select the Use
Recording check box in the recording options during the
System setup.
Note The date and time displayed on the Record Player indicates
when the recording was made on RASplus.
Note The icon will display on each screen when panic recording
starts.
Status View
RASplus provides a display of event, alarm out, system check and recording status
information from the connected remote site in real-time. To connect the remote site,
select the site or camera you want to connect to from the Remote Site or Emergency
Event View panel and then drag and drop it in the Status View panel. Or, you can select
Connect Status from the popup menu displayed by clicking the right mouse button
after selecting the site from the Remote Site list.
78
Operation
Function Buttons
Remote Setup: Allows changing the setup of the remote DVR connected to the
Status View panel.
Note Refer to the manual for each applicable remote DVR for more
details on system setup.
Remote System Log: Displays the system log information of the remote DVR
connected to the Status View panel.
Remote Event Log: Displays the event log information of the remote DVR
connected to the Status View panel.
Note See Remote Menu, page 50, for more details on the Remote
System Log and Remote Event Log.
Note When the remote site is not connected to the Status View panel,
Remote Setup, Remote System Log and Remote Event Log
menus can be accessed by clicking the right mouse button after
selecting the remote site on the Remote Sites panel.
Remote Panic Control: Controls panic recording of the remote DVR that is
connected in the status view panel. (Panic Recording On) indicates that the
remote DVR is not in the panic recording mode and that you can start panic
recording by clicking the button. (Panic Recording Off) indicates that the
remote DVR is in the panic recording mode and that you can stop recording by
clicking the button.
The Status Display Window displays the event, alarm out, system check and recording
status information of the remote system connected to the Status View panel in real-time.
80
Video Clips Review
A
Video Clips Review
You do not need to install any special software on your personal computer to review
video saved as Self-Player files. The file contains a built-in Player program.
Double-clicking the target file starts the Player program.
Note The Player GUI will differ depending on the model of the remote
DVR that is connected to RASplus when reviewing the video
saved as a Self-Player file.
MiniBank Player
Note Honeywell suggests that the computer used for the MiniBank
Player program has at least an 800MHz Pentium III. If your CPU
is slower than this, video clips recorded at maximum speed with
very high image quality will be played back slowly.
The Monitoring Screen displays the backed up images. Click the right mouse button
on the image while holding the Shift key to switch the screen size. Click and hold the
left mouse button and drag the image to move its position.
Click Save to save the current image in a bitmap file format on the local hard disk drive
or floppy disk.
Click Print to print the current image on the printer connected to your computer.
The Backup File Information window displays information regarding the backup file.
Location displays the site description of the DVR where the backup was made. Record
displays the time span of the video backup file. Encryption displays whether the
backup file has been tampered with. Normal means the file has not been tampered
with, Wrong means the system has detected tampering, and no mark means the user
cancelled the encryption check.
The Current Image Information window displays information about the current image.
Camera Title displays the camera name of the current image, and Time displays the
date and time the image was recorded.
The Image Search Slide Bar displays the current playback position. The user can
move to another image by clicking and dragging the slide bar.
82
Video Clips Review
The Playback Function Buttons include fast backward, backward, play, pause, fast
forward, go to the first image, go to the previous image, go to the next image, and go
to the last image buttons.
The Brightness Control Slide Bar adjusts the brightness of the backup images by
clicking and dragging the slide bar. Minute brightness change can be made using
and located at each end of the bar.
Click the Zoom Out / In buttons to zoom in or out of the current image. Scrolling the
mouse wheel up or down on the image also zooms in or out.
Clicking the OSD (On-Screen Display) button switches the OSD option. The OSD
information includes camera location and date/time.
Double-clicking the logo at the top left corner while holding the Shift key switches
video formats when you are experiencing improper image display.
Clip Player
Note It is suggested that the computer used for the Clip Player
program has at least an 800MHz Pentium III. If your CPU is
slower than this, video clips recorded at maximum speed with
very high image quality will be played back slowly. Also, DirectX
9.0 or higher is required to install, and a VGA card with 16 MB or
higher video RAM is recommended for proper operation.
Note You will be asked to enter the password to initiate the Clip Player
program if you select the Save Password option when saving
recorded video.
Please check the driver version of the video card and update it to
the latest available version. If you still have display problems
after changing all display settings described above, try replacing
the video card. Video cards with an ATI chipset are
recommended.
84
Video Clips Review
Click to show the previous camera group if there is recorded video in the previous
camera group in the current screen mode.
Click to cycle through the screen layouts. It cycles through 2x2, 1+7, 3x3 and 4x4.
Click to show the next camera group if there is recorded video in the next camera
group in the current screen mode.
Click to set up the Clip Player properties. The Clip Player menu opens.
Option Function
Frame Info Displays the Channel, Title, Time, Type, Size, and
Resolution information about the image.
Image Processing Controls brightness, blur, and sharpness of playback
images. (Single-screen layout and Pause Mode only)
Option Function
Play Speed Control Changes the playback speed (Play) or fast
forward/backward speed (FF/RW).
Drawing Mode Selects the draw mode level. If you are not sure about the
best draw mode level for your system, try each level until
the image displays properly.
Enable Audio Plays audio while playing back recorded video that has
recorded audio. (Single-Screen Layout Only)
Show Text-In Displays video with text-in data if the video was recorded
with text-in data. (Single-Screen Layout only)
Option Function
Save as Image (Actual Size) Save the current video frame as a bitmap or
JPEG file in its actual size. (Single-screen layout
only)
86
Video Clips Review
Option Function
Save as Clip-Copy Save video for the desired time range as an
executable file.
Save as Video Save video for the desired time range as an AVI
file.
Click to enlarge the image or display the image in its actual size (Single-screen
layout only). You can move the enlarged image by clicking the left mouse button and
dragging.
Encryption icons display in the bottom-right corner. displays when the clip file has
not been tampered with, and displays and playback stops when the system has
detected tampering.
Note If the VGA card or monitor does not support 800x600 video
resolution, Full Screen might not display properly. If this
happens, press the ESC key on your keyboard to return to the
normal screen mode.
Click the slider bar and move it left or right to move through the video clip.
Placing the mouse cursor on an image and clicking it will cause that image to display
full frame.
88
DVR Name Service (DVRNS)
B
DVR Name Service (DVRNS)
Using Static IP addresses in LAN/WAN networks requires high management overhead
and increases the cost burden to users. Therefore, it has become essential for DVRs to
support Dynamic IP addresses in ADSL/VDSL networks using DHCP (Dynamic Host
Configuration Protocol). This reduces cost burdens and increases cost-effectiveness
for system users. Use the following steps to set up a system using DVRNS.
System Configuration
STEP 4
DVR
RASplus
STEP 1
STEP 3
STEP 2
DVRNS Server
Register the unit name and IP address of the DVR during the DVRNS setup on the
Remote DVR. This unit name and IP address will be registered on the DVRNS server
directly.
Note Refer to the DVR and DVRNS Server guides for detailed
information on the DVRNS and DVRNS Server setup.The DVRNS
server software and user guide are on the RASplus CD.
Request the IP address of the remote DVR using the registered unit name of the DVR
you want to connect to.
Connect to the target DVR using the IP address returned from the DVRNS server.
90
Map Editor
C
Map Editor
The Map Editor program allows you to create 3-D maps of remote sites. With the
drag-and-drop and link function, you can create and edit the map easily and efficiently.
Run the program by selecting Map Editor from the RASplus options under the Start
menu in Windows.
Option Menu
Click the Option menu to set up the remote site information, the device status display,
and the remote site name to display.
Site Information Setting Select the Site Information Setting… in the Option menu to
set the information about the remote site connections, and the following Site
Information setup window appears.
92
Map Editor
2. In the Remote Site Setup area, enter the site name and IP address of the DVR
connected to the devices you want to include on the map.
3. Click Port… and enter the network IP port number (8000 to 12000) that matches
the value set during the LAN setup of the DVR.
4. Check the box beside Use DVRNS (DVR Name Service) if you want to use the
DVR name service.
Note If you use DVR Name Service, you can enter the name registered
on the DVRNS server instead of the IP address of the DVR, and
you do not need to enter the network IP port number.
5. Under Login Setup, enter the user ID and password for the DVR associated with
devices.
6. Under DVRNS Server, enter the IP address and port number (10000 to 12000) of
the DVRNS server, which matches the values set during the DVRNS setup on the
DVR.
7. Clicking OK saves the setting.
Popup Dwell Time Select Popup Dwell Time... in the Option menu to set the duration
that the Map popup screen displays when events are detected. Figure C-6 appears.
Check the box beside Use Timeout and adjust the time out dwell time from 1 second
to 5 minutes. Select Display Remaining Time to display the remaining time out dwell
time on the Map popup screen.
Note Popup Dwell Time will be applied to all maps displayed on the
map panel.
Status Color Setting Select Status Color Setting… in the Option menu and
Figure C-7 appears. You can set the device to display a unique color reflecting its status
on the Map panel.
Check the box beside Color Use and select each status box to use. Click each selected
status box and select the desired color. Click OK.
Unplugged: Either connection to the remote site has failed, or the Device
No. for the device is not supported by the site.
Event off: Event detection is not set up.
Irregular: The device is not working properly.
Video Loss: Video loss is detected.
Motion: Motion is detected.
Alarm In: Alarm in is detected.
Alarm Out: Alarm out is detected.
Note The device displays mixed colors when detecting more than two
statuses at the same time.
94
Map Editor
Name Table Select Name Table… in the Option menu to display the name instead of
the IP address of the DVR on the Map panel. Figure C-8 appears.
Click the Display Name field of each IP address and enter the name of the DVR to
display on the popup screen.
Device Setting
Property Description
General
Name Enter a device name.
Description Enter a description of the device.
Property Description
Site Information Select a proper site for the device in the list, and the Equipment
fields (User, Password, IP Address and Port) are filled
automatically with the information set in Site Information Setting....
Image Select an image of a device.
Ratio Adjust the size of the device image.
X Coordinates / Y Adjust the position of the device image by clicking each field and
Coordinates changing the numbers.
Horizontal / Vertical Adjust the size of the device image by clicking each field and
changing the numbers.
Popup Camera If the selected device is an alarm-in device, you can associate a
camera with the sensor by entering the camera name. The camera
name you enter should be the same as the camera name entered
under the Property [Camera] tab. The Map panel pops up another
screen and displays images of the camera associated with the
sensor on the popup screen when an alarm-in event occurs.
Equipment
IP Address / User / Each field is filled in automatically with the information (user ID,
Password / Port password, and port number) set in Site Information Setting..., or
you can enter it manually.
Device No. Set the device number (1 ~ 32) for each device. If the selected
device is a camera, Device No. changes to Camera No.
DVRNS Use Select Yes to use DVR Name Service, and the DVRNS field appears.
Enter the IP address (or domain name) and the port number of the
DVRNS server, and the name of the DVR registered on the DVRNS
server.
Note You should not select numbers that are not supported for
devices on the remote DVR when selecting Device No.
Otherwise, the map cannot detect the device and it displays the
device status as Unplugged. For example, the device number
should be from 1 to 16 when the device is connected to a
16-channel DVR.
Note If you set the IP address and port number of the DVRNS server in
Site Information Setting…, the DVRNS fields are filled with the
information automatically.
96
Map Editor
4. Go to the Event [Camera/AlarmOut/AlarmIn] tab and set the option for the
devices.
• Event [Camera]: Selecting an event from a drop-down list and checking the
Watch View Popup box sets the Map panel to pop up another screen when
an event occurs. Selecting Click from a drop-down list and checking the
Watch View Popup box pops up another screen by clicking the mouse
button on the camera icon on the Map panel regardless of event detection.
• Event [AlarmOut]: Checking the Switch on/off box controls the alarm-out
remotely by clicking the alarm-out icon on the Map panel.
• Event [AlarmIn]: Selecting Alarm-in Event from the drop-down list and
checking the Watch View Popup box sets the Map panel to pop up another
screen when an alarm-in event occurs. Selecting Click from a drop-down list
and checking the Watch View Popup box pops up another screen by
clicking the mouse button on the alarm-in icon on the Map panel regardless
of event detection.
Link Setting
1. Click (Link) on the toolbar and place it on the screen linked with a sub-map.
2. The Link Map box appears. Select the individual link boxes by using the
Ctrl key on the keyboard, and then adjust the size and position of the link box
using a mouse, a keyboard or the icons shown below.
3. Go to the Property [Link] tab and set the properties of the selected link box.
Property Description
Name Enter a name for the link box.
Image Double-click the field and select an image to insert in the link box.
Link Document Double-click the field and select a map to be linked with the link box.
Ratio Adjust the image size within the link box.
X Coordinates / Y Adjust the position of the link box on the screen by clicking each field
Coordinates and changing the numbers.
Horizontal / Vertical Adjust the link box size by clicking each field and changing the
numbers.
Text Show Select Yes to display the name of the link box on the selected image.
98
Map Editor
You can monitor the remote sites by using the map. See Map Panel on page 28 for more
information.
100
Honeywell Security Group (Head Office) Honeywell Security Group Northern Europe
2700 Blankenbaker Pkwy, Suite 150 Ampèrestraat 41
Louisville, KY 40299, USA 1446 TR Purmerend, The Netherlands
www.honeywellvideo.com www.honeywell.com/security/nl
℡ +1.800.796.2288 ℡ +31.299.410.200
Honeywell Security Group Middle East/N. Africa Honeywell Security Group España
Post Office Box 18530 Mijancas 1. 3a planta
LOB Building 08, Office 199 P. Ind. Las Mercedes
Jebel Ali, Dubai, United Arab Emirates 28022 Madrid, Spain
www.honeywell.com/security/me www.honeywell.com/security/es
℡ +971.04.881.5506 ℡ +34.902.667.800
www.honeywellvideo.com
+1.800.796.CCTV (North America only)
[email protected]
Document 800-05056 – Rev C – 11/09
© 2009 Honeywell International Inc. All rights reserved. No part of this publication may be reproduced by any means
without written permission from Honeywell. The information in this publication is believed to be accurate in all respects.
However, Honeywell cannot assume responsibility for any consequences resulting from the use thereof. The information
contained herein is subject to change without notice. Revisions or new editions to this publication may be issued to
incorporate such changes.