SMART GEN
SMART GEN button:
SMART GEN operation.
3
4
5
when SMART GEN and POWERCHILL button
SMART GEN
SMART GEN
6
7
SMART GEN Operation
- Smart Gen operation provides user with manual control to select the power consumption of
air conditioner based on Generator power.
- User can adjust the air conditioner input power requirement by selecting L1 (100%) , L2
(85%) , L3 (70%) , L4 (55%) , L5 (40%) .
To start the Smart Gen Operation To check the Smart Gen
operation power input step:
- Using the remote,turn on the air conditioner. - If the user wants to check which power
- Press the button on the remote controller.
SMART GEN
input step is currently in operation, they
- If the user turns on smart gen operation for the rst need to press the button on the
SMART GEN
time, the symbol along with the L1 step will be remote controller.
displayed on the remote LCD. - The last power input step will be displayed
- By pressing the button on the remote controller, on the remote LCD.
SMART GEN
the user can select dierent power input.
To cancel the Smart Gen Operation
- If Smart Gen operation is already turned ON, and the user
wants to turn OFF the Smart Gen operation, then the user
needs to press the button on the remote controller.
SMART GEN
- The remote LCD will display the last selected power input
step; for example, "L2" will be shown on the remote LCD.
- User needs to press the button in the following
SMART GEN
manner until normal operation.
Normal Operation
Mode or TURN OFF
SMART GEN operation
* Last Memorised Step
symbol will be removed from the remote
LCD.
Notes on the Smart Gen Operation
1. In the event of power failure, the selected power input step will be memorized and retained
when power is restored.
2. This function operates only in Dry, Cool, Heat, and Auto modes.
3. Power Chill, Power Full, Dew Clean, and Fan mode operations cannot be used together with the
smart gen function. Priority will be given to the last selected function.
4.If the user removes the battery and reinserts it while using smart gen function, the smart gen
feature is turned o on the remote. The user will need to restart the smart gen operation and select
the desired power input step again.
5.For the safety and reliability of the AC, the smart gen function may not work in lower and higher
outdoor ambient conditions.
6.It is recommended that the user does not turn o the operation lamp and timer lamp LEDs (using
the Brightness control function). Otherwise the user will not be notied in case they select the
wrong step in accordance with the heat load condition.
7.If the user selects a power input step that is not in accordance with the room heat load conditions,
this function will notify the user to change the power input step, as dened below:
Ø After 30 minutes of the machine working, the Operation Lamp (Green) and Timer Lamp(Orange) will blink for
32 seconds to indicate to the user that they should change the power input step.
Ø If the user does not change the power input step, the next judgment will be taken after the next 15 minutes of
machine working. Until the user changes the power input step, the Operation Lamp(Green) and Timer Lamp
(Orange) will blink for 32 seconds to remind the user to change the power Input change.
Ø If the event of power failure during the above judgement, the timing will restart from zero once power is
restored
8
9
10
LED BRIGHTNESS Control Operation
The brightness of the indicator lamp can be adjusted H(High), L(Low), or OFF.
is displayed on the LCD of remote.
DEW CLEAN function aids in cleaning the accumulation of dust on the Indoor Heat Exchanger.
To start the DEW CLEAN operation:
Using the remote, turn on the air conditioner.
Press, hold and release the “ ” button for a duration between 2 to 9 seconds.
The “ ” symbol shall blink four times on remote LCD screen and remain visible in the LCD display.
After the completion of blinking by the “ ” symbol, the LCD display shall return to normal. The ON
symbol “ ” the fan symbol with Auto Fan speed “ ” , and the DEW CLEAN symbol “ ” shall
remain on the LCD display for the entire duration of the DEW CLEAN function operation (Refer to
below image).
To check the DEW CLEAN operation:
During the operation, the LED indicator lamp (green and orange) on the indoor unit
shall blink simultaneously.
The operation stops automatically according to the defined process, and the unit shall be
switched off after the completion of the DEW CLEAN operation.
To Cancel the DEW CLEAN operation:
Press hold, and release the “ ” button for a duration between 2 to 9 seconds, or alternatively
use the “ ON/OFF ” button.
Upon completion of the DEW CLEAN function (either by the stipulated time expiring or through
cancellation of the operation), both the remote and the unit shall revert to the OFF state, restoring
them to the state they were in before the DEW CLEAN function was activated.
Notes on the DEW CLEAN operation:
Users are recommended to turn "OFF" other features (like ON/OFF timer, good sleep etc.) operations before
turning "ON" dew clean operation.
11
12
13
14
15
Is the air conditioner in SAMRT GEN operation or GOOD SLEEP
OFF TIMER operation?
16
17
3P665364-14Y M24P131
SMART GEN
FTKL25UV16WZ
FTKL35UV16WZ
FTKL50UV16VZ
FTKL60UV16UZ 3P665364-14Y M24P131