0% found this document useful (0 votes)
28 views4 pages

Arjo - Flowtron ACS900 Pump. Specs sheet.1.0.INT - EN.Artwork

Uploaded by

1987umesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views4 pages

Arjo - Flowtron ACS900 Pump. Specs sheet.1.0.INT - EN.Artwork

Uploaded by

1987umesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Flowtron ACS900 ®

ACTIVE COMPRESSION SYSTEM

CONVENIENT, COMFORTABLE AND CLINICALLY PROVEN VTE PREVENTION

Reduce the risk of VTE in your facility


with the Flowtron ACS900 pump
Featuring SmartSense 2 Automatic Garment Recognition and Compliance Monitoring technology

www.arjo.com
A smart system designed
to solve challenges in the
clinical setting

Smart and adaptive


Automatic garment recognition together with one-button start
make Flowtron a true plug-and-play solution that is easy to set
up and operate. Reducing the need for user intervention by
automatically identifying garments connected and setting the
correct compression profile – for safety and efficacy.1,2,3

Compliance monitoring
Intuitive on-screen compliance monitoring, recording and
displaying actual therapy as well as non-compliant time
in an accurate manner. Alerts the caregiver upon garment
removal to aid concordance, and facilitates tracking and
documentation of IPC therapy.4,5

Alarms and indicators


Advanced alarms, including visual indicators allowing
operation to be clearly seen from any direction, and
real-time pressure indication designed to limit the risk of
operator error and potential patient harm – for safety and
caregiver peace of mind. 3

Quiet operation
QuietConceptTM noise reduction technology significantly
reducing pump noise to minimise patient and caregiver
disruption. Allowing the ACS900 to deliver therapy in a
quiet manner across all garment types, contributing to a
quieter care environment.6

1 Arjo Data on File: Customer Acceptance Test (CAT) Report 100035688. June 2015. 2 Arjo Data on File: Functional Test Report 100035587. December 2019. 3 Busby J,
Holst K, Hansson K. User feedback on the Flowtron® ACS900 pump and Tri Pulse garment range. Arjo Whitepaper. June 2021. Arjo.A00491.1.0.INT.EN. 4 Arjo Data on
File: Compliance Monitoring Test Report 100126883. November 2021. 5 Arjo Data on File: Summative Evaluation Report (SER) 100116863. November 2021. 6 Arjo Data
on File: Audible Test Report 100127045. ACS900 MLU. Acoustic Noise Testing of Medical Pumps. Southwest Research Institute. November 2021.
Visit
www.arjo.com/vte
for more
information

Complete range of garments


A wide variety of garment types and sizes ensuring
effective and comfortable therapy for all patients and
clinical needs3,7,8. The system allows for any combination
of foot, calf and calf-and-thigh garments to be used
simultaneously.

Durable and energy efficient


VTE prevention around the clock* with SmartEnergyTM
enhanced power management ensuring uninterrupted
calf therapy for a minimum of 24 hours when the pump
is not connected to a power outlet9. SmartEnergy also
contributes with reduced power consumption, CO2
emissions and cost10.

Fixed tubesets
Ready for therapy at all times with fixed tubesets preventing
disconnection and loss of tubing, hence eliminating the
inconvenience and cost of replacements.3

Integrated cable management system


Integrated cable management system aiding tubeset and
power cord management in the clinical area and during
storage/transportation, promoting caregiver convenience
and patient safety.2-4,11

*Calf: >24h / Thigh: >18h / Foot: >9h. 7 Ellis J. The textile properties of Deep Vein Thrombosis (DVT) garments: a factor in patient compliance with Intermittent
Pneumatic Compression (IPC) systems. Arjo Whitepaper. March 2019. Arjo.A00096.1.0.INT.EN. 8 Arjo Independent Test Data on File. Tri Pulse: water vapour
resistance, thermal resistance (single plate method), drying time, liquid wicking rate and water vapour permeability testing. September 2019. Test report E-008677/C. 9
Arjo Data on File: Battery Study Report 100127047. ACS900 MLU. November 2021. 10 Arjo Data on File: Electrical Efficiency Measurements Report 100127046. ACS900
MLU. November 2021. 11 Arjo Data on File: Summative Usability Validation Report 100035519. December 2014.
Flowtron ACS900 pump Flowtron DVT garments

Model Type Tube length Application Item ref Size Measurement

ACS900 Standard 2.1m/7ft DVT5 ≤ 36cm/14in

ACS900 OR (Operating Room) 4.0m/13ft DVT10 ≤ 43cm/17in

DVT20 ≤ 58cm/23in

Specification ACS900 DVT60L ≤ 81cm/32in

Type of compression Uniform or Sequential


Calf, Calf/Thigh, Foot DVT30 ≤ 71cm/28in

Set presssure
Uniform: 40 ± 5 mmHg DVT40 ≤ 89cm/35in
Sequential 45 ± 5 mmHg US (M) ≤ 7
Foot: 130 ± 10 mmHg US (F) ≤ 9
FG100 S-M
EU ≤ 40
Compression cycle UK ≤ 7
Uniform/Sequential: 12 sec. inflation;
US (M) ≥ 7.5
48 sec. deflation US (F) ≥ 9.5
Foot: 3 sec. inflation; FG200 L-XL
EU ≥ 41
27 sec. deflation UK ≥ 7.5

Battery type 14.4V, 2600mAh.


Lithium Ion pack
Power 100V-230V, 50-60Hz,
10-40VA Flowtron Tri Pulse garments
Pump size H230 x W226 x D196mm /
9.1 x 8.9 x 7.7in
Application Item ref Size Measurement
Weight 3.8kg/8.5lb
TRP10 ≤ 43cm/17in

TRP20 ≤ 58cm/23in
Accessories
TRP60L ≤ 81cm/32in
Wall OR(Operating
mount Room) IV pole mount
Item ref: 526366 Item ref: 526359 TRP30 ≤ 71cm/28in

TRP40 ≤ 89cm/35in

Flowtron Garments

Compression type Application

Sequential Uniform Foot Calf Thigh

Sizing
Small Medium Large X-large, bariatric

Arjo.A00558.1.0.INT.EN – Flowtron ACS900 Pump Spec sheet 2022. Only Arjo designed parts, which are designed specifically for the purpose, should be used
on the equipment and products supplied by Arjo. As our policy is one of continuous development we reserve the right to modify designs and specifications without prior notice.

You might also like