American Airlines A319_A320_A321_LUS
PRINTED : Apr-22-2024 09:23 PM AMM
REV : 8
Revision Date : Apr-05-2024
Task 24-38-34-400-001-A Previous Task
Installation of the Battery Charge Limiter (BCL)
Zone(s):126
FIN(s): 1PB1 [ 001-999] 1PB2 [001-999]
Effective on: 001-999
Effective on: 001-999
1. Reason for the Job
Self explanatory
Effective on: 001-999
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
REFERENCE QTY DESIGNATION
No specific AR ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific AR CAP - BLANKING
No specific AR SAFETY CLIP - CIRCUIT BREAKER
No specific AR WARNING NOTICE(S)
B. Work Zones and Access Panels
ZONE/ACCESS ZONE DESCRIPTION
126 LATERAL AVIONIC COMPARTMENT
822 (accpan)
C. Referenced Information
REFERENCE DESIGNATION
24-38-00-710-001-A Operational Check of Battery Charge Limiter (BCL) No 1 and No 2 Via Centralized Fault Display
System (CFDS)
24-38-00-710-001- Operational Test of the Battery Charge Limiter (BCL) (without the Centralized Fault Display System
A-01 (CFDS))
24-42-00-861-001-A Energize the Ground Service Network from the External Power
24-42-00-862-001-A De-energize the Ground Service Network Supplied from the External Power
Battery Charge Limiter
3. Job Set-up
Filtering is on : CEC=559 24-38-34-400-001-A Page 1 of 5
AIRBUS PROPRIETARY - Copyright © Unpublished Work DO NOT RETAIN FOR REFERENCE
American Airlines A319_A320_A321_LUS
PRINTED : Apr-22-2024 09:23 PM AMM
REV : 8
Revision Date : Apr-05-2024
Effective on: 001-999
SUBTASK 860-051-A
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
Ref. 24-42-00-861-001-A .
(2) In the cockpit, on the overhead panel 35VU, make sure that the BAT pushbutton switches are released.
(3) In the cockpit, on the overhead panel 35VU, make sure that the WARNING NOTICE(S) is in position to tell persons
not to operate the batteries.
(4) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 822.
(5) Make sure that the access door 822 (accpan) is open.
(6) Make sure that the access panel of the BATTERY power center 105VU is open.
Effective on: 001-999
SUBTASK 865-051-A
B. Make sure that the circuit breaker(s) that follow(s) is (are) open, safetied and tagged. Use the SAFETY CLIP - CIRCUIT
BREAKER as necessary.
PANEL DESIGNATION FIN CLIPPED LOCATION
For 1PB1 (BCL-1)
Effective on: 001-999
105VU (elec) ELEC/BAT REF/BCL1 9PB1 F01
Effective on: 001-999
105VU (elec) ELEC/BAT BUS/REF/BCL1 8PB1 G01
For 1PB2 (BCL-2)
Effective on: 001-999
105VU (elec) ELEC/BAT REF/BCL2 9PB2 F02
Effective on: 001-999
105VU (elec) ELEC/BAT BUS/REF/BCL2 8PB2 J02
Filtering is on : CEC=559 24-38-34-400-001-A Page 2 of 5
AIRBUS PROPRIETARY - Copyright © Unpublished Work DO NOT RETAIN FOR REFERENCE
American Airlines A319_A320_A321_LUS
PRINTED : Apr-22-2024 09:23 PM AMM
REV : 8
Revision Date : Apr-05-2024
4. Procedure
Effective on: 001-999
Battery Charge Limiter
Effective on: 001-999
SUBTASK 420-050-A
A. Installation of the BCL
(1) Install the BCL (1) on its support.
(2) Install the screws (4) and the washers (3).
NOTE: When you install the two BCLs with different standard Part Numbers (P/N), there can be a small
overlap between the BCL lugs with no effect in the operation of the BCLs.
(3) Tighten the screws (4).
(4) Remove the CAP - BLANKING from each electrical connector and receptacle.
(5) Make sure that all the electrical connections are clean and in the correct condition.
(6) Connect the connector (2) to the BCL (1).
Effective on: 001-999
SUBTASK 865-052-A
B. Remove the SAFETY CLIP - CIRCUIT BREAKER and the tag(s) and close this (these) circuit breaker(s):
PANEL DESIGNATION FIN CLIPPED LOCATION
For 1PB1 (BCL-1)
Effective on: 001-999
105VU (elec) ELEC/BAT REF/BCL1 9PB1 F01
Effective on: 001-999
105VU (elec) ELEC/BAT BUS/REF/BCL1 8PB1 G01
For 1PB2 (BCL-2)
Effective on: 001-999
105VU (elec) ELEC/BAT REF/BCL2 9PB2 F02
Effective on: 001-999
105VU (elec) ELEC/BAT BUS/REF/BCL2 8PB2 J02
Effective on: 001-999
SUBTASK 710-050-A
C. Do an operational test of the BCL from the CFDS
Ref. 24-38-00-710-001-A
Ref. 24-38-00-710-001-A-01 .
NOTE: As an alternative procedure, you can do this operational test without the CFDS
Ref. 24-38-00-710-001-A
Ref. 24-38-00-710-001-A-01 .
Filtering is on : CEC=559 24-38-34-400-001-A Page 3 of 5
AIRBUS PROPRIETARY - Copyright © Unpublished Work DO NOT RETAIN FOR REFERENCE
American Airlines A319_A320_A321_LUS
PRINTED : Apr-22-2024 09:23 PM AMM
REV : 8
Revision Date : Apr-05-2024
5. Close-up
Effective on: 001-999
SUBTASK 410-050-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access panel of the BATTERY power center 105VU.
(3) Close the access door 822 (accpan) .
(4) Remove the WARNING NOTICE(S).
(5) Remove the access platform(s).
Effective on: 001-999
SUBTASK 862-050-A
B. De-energize the ground service network
Ref. 24-42-00-862-001-A .
Filtering is on : CEC=559 24-38-34-400-001-A Page 4 of 5
AIRBUS PROPRIETARY - Copyright © Unpublished Work DO NOT RETAIN FOR REFERENCE
American Airlines A319_A320_A321_LUS
PRINTED : Apr-22-2024 09:23 PM AMM
REV : 8
Revision Date : Apr-05-2024
822
105VU
FR16
FR9
1PB1
1PB2
4
3
N_MM_243834_4_AAM0_01_00
Battery Charge Limiter
Battery Charge Limiter (Sheet 1 of 1)
[Applicable to: 001-999]
Filtering is on : CEC=559 24-38-34-400-001-A Page 5 of 5
AIRBUS PROPRIETARY - Copyright © Unpublished Work DO NOT RETAIN FOR REFERENCE