SUPER POR-ROK
Founded, Based and Premium Cement Based
MADE IN THE U.S.A. Anchoring Cement
DESCRIPTION:
SUPER POR-ROK ANCHORING CEMENT is used in the anchoring of heavy machinery, railings, guard rails,
banisters, repairing of cracks on damaged concrete substrate. It is a non-shrink, hydraulic, controlled
03 61 00
Cementitious Grouting 3
expansion cement in a ready to use preparation. Water is added at the job site to provide a pourable, durable
anchoring or patching compound.
SUPER POR-ROK ANCHORING CEMENT has almost unlimited field applications.
03 50 00
Concrete Repair 3
TYPICAL APPLICATIONS:
PACKAGING:
Anchors-Bolts, Dowels, Railings, Reinforcing Rods, Machinery, Pipes in Concrete
50 lbs. pails and 5 lb. tubs
Grouts—Heavy Machinery, Structural Columns, Bearing Plates, Pre-cast Columns
In setting, exerts expansion forces which “locks in” COLOR:
Anchor bolts, railings, etc. Light Grey
PRODUCT FEATURES: POT LIFE:
No rodding, chaining or vibrating 10 minutes
Pourable
Ideal for patching floors, walls, crack in concrete structures, caulking foundations/wall voids SET TIME: @ 70˚F
Interior or Exterior use 60 Minutes
No heating or two component mixing needed COVERAGE:
Quick Setting - Sets in 15 minutes 50 lbs. of SUPER POR-ROK will
Expands as it sets cover .5 cubic feet
Stronger than concrete in 6 hours
WEIGHT:
Product complies with all the properties of ASTM C1107 when tested at 73 degrees.
129 lbs per cubic foot
SUBSTRATE PREPARATION:
APPLICATION TEMPERATURE
The concrete must be at least 28 days old and fully cured. The hole must be free of particles and debris. Fill
RANGE:
hole with water-scrub sides and bottom with stiff scrub brush. Remove excess water. The hole must be clean
35˚ - 95˚F
and uniformly damp. Always use the appropriate flat washer or the size bolt you are anchoring. Place bolt in
hole with head down and washer resting on the head. COMPRESSIVE STRENGTH
(ASTM C 109)
ANCHOR SIZE INSTALLATION RECCOMENDATIONS: 3 Hours 2,100 psi (14.4 MPa)
1 Day 4,500 psi (31.0 MPa)
Diameter (Anchor, Bolt) Width (Min-Max) 7 Days 5,600 psi (47.7 MPa)
1/4”…………………………………….1/2” - 3/4” 28 days 7,200 psi (63.8 MPa)
3/8”…………………………………….5/8” - 1”
1/2”…………………………………….3/4” - 1-3/4” BOND STRENGTH
5/8”…………………………………….1” - 2” (USING A325 BOLTS)
3/4”…………………………………….1” - 2-1/2” Bolt Dia. Hole Dia. Depth
1”………………………………………1-1/2” - 3-1/2” 1/2” 1-1/2” 6”
1-1/4”………………………………….1-1/2” - 4-1/4” Result: 28,900 Psi (Bolt Broke
1-1/2”………………………………….2” - 4”
Bolt Dia. Hole Dia. Depth
2”………………………………………2-1/2” - 4 “
1” 2-1/4” 10”
2-1/2”………………………………….3” - 4”
Result: 73,000 Psi
3”………………………………………4”
Bolt Dia. Hole Dia. Depth
EXPOSED ALUMINUM WARNING: For aluminum railing installations CMP recommends the use of # 4 Rebar 1” 8”
Por-Rok. In instances where SUPER POR-ROK has to be used the aluminum railing must be coated Result: 26,500 Psi (Rod Fractured)
both inside and out. Installing SUPER POR-ROK to exposed aluminum will cause uncontrolled
expansion which may result in installation failures. Bolt Dia. Hole Dia. Depth
# 8 Rebar 2” 16”
Result: 75,000 Psi (Rod Fractured)
CMP Specialty Products (A Division of CGM, Inc.) SUPER POR-ROK: Page 1 of 2
1445 Ford Road Bensalem, PA 19020 - Phone: 267.522.8000 - Fax 215.638.7949 - www.cmpsp.com Technical Datasheet (Rev. 2-15)
SUPER POR-ROK
MIXING AND INTERIOR APPLICATIONS:
Flexural Strength:
NOTE: SUPER POR-ROK is a cement based anchoring cement. Adding more water than recommended will
1260 psi
cause a delayed set time, lower strengths and surface dusting.
Add 3/4 quarts (24 oz) of clean potable water to every 10 pounds of SUPER POR-ROK and mix to a smooth Tensile Strength:
flowable consistency. If mixing smaller amounts by hand mix 1 part water with 5 parts SUPER POR-ROK. 450 psi
Once the mix is lump free, pour the material around the bolt or anchor. Fill the material slightly above substrate
level (DO NOT LEAVE THE SUPER POR-ROK SET IN WHERE WATER CAN PUDDLE AROUND THE BOLT Required Tools:
OR ANCHOR). Low rpm Drill
Jiffy type mixing paddle
For applications that require a more plastic like consistency, reduce the amount of water slight until the desired
Water measuring pail
consistency is achieved.
Mixing pail
IMPORTANT APPLICATION NOTES AND LIMITATIONS:
1. DO NOT OVER-WATER SUPER POR-ROK. Over-watering cement based products can inhibit
long term strength and durability.
2. SUPER POR-ROK should be poured slightly above substrate level. Leaving a depression would
allow water to settle in the application and weaken its integrity over time.
3. The hole to accept the bolt or anchor should not be drilled with 4” of the corner or the edge of
the concrete substrate.
4. Do not install SUPER POR-ROK where the application temperature will go below 32 degrees
within 24 hours.
5. If a smooth surface is desired a flat trowel can be used when SUPER POR-ROK begins to stiffen. Eligible LEED credits : 5
6. Temperature will effect set time. Colder temperatures will extend set time while warmer Regional Materials (MR 5.1 & 5.2)
2 Points
temperatures will shorten set time and workability.
7. For aluminum railing installations CMP recommends the use of Por-Rok. In instances where SUPER Low Emitting Materials (EQ 4.1)
POR- ROK has to be used the aluminum railing must be coated both inside and out. Installing SUPER 1 Point
POR-ROK to exposed aluminum will cause uncontrolled expansion which may result in installation failures.
STORAGE:
Store in cool dry place. Tightly seal
package and do not expose to sun.
FLAMMABILITY: (ASTM E-84)
Flame Spread: -0-
Fuel Contribution: -0-
Smoke Development: -0-
VOLITALE ORGANIC COMPOUNDS
0 g/l
CLEAN UP:
Clean tools with water immediately after use
or by mechanical means once dry.
HEALTH AND SAFETY:
Always refer to the Safety Data Sheet (SDS)
prior to using this product for full Health,
Safety and Handling guidelines. SDS sheets
are available by calling 267.522.8000 or you
can visit www.cmpsp.com
For Professional Use Only
KEEP OUT OF REACH OF CHILDREN
CMP Specialty Products (A Division of CGM, Inc.) SUPER POR-ROK: Page 2 of 2