+ Type K THERMOMETER

DEW POINT HUMIDITY METER


Model : HD-3008 ISO-9001, CE, IEC1010

LUTRON ELECTRONIC
+TYPE K THERMOMETER
Dew Point HUMIDITY METER
Model : HD-3008
FEATURES
* Humidity + Dew point + Type K Thermometer are * Records Maximum and Minimum readings with
combined into one meter, intelligent. recall.
* Humidity measurement uses a high precision * Data hold function for stored the desired value
thin-film capacitance sensor for fast response, on display.
not depend on air movement past the probe. * RS 232 PC serial interface.
* Thin-film capacitance sensor for humidity * Show the humidity & temperature values on the
measurement, high precision. LCD display at same time.
* Type K thermometer build in temperature linearity * Temperature function for ℃ or ℉ be selected by
& precision cold junction compensation circuit, high push button on front panel easily.
accuracy. * Built-in low battery indicator.
* Microprocessor circuit assures maximum possible * Humidity probe built-in thermistor sensor for
accuracy, provides special functions and features. temperature measurement, fast response time.
* Large LCD with two display, easy readout. * Wide range both of humidity & temp. measurement.
* Heavy duty & compact housing case, designed * Separate humidity & temp. probe, easy operation. &
for easy carry out & operation. remote measurement.
* Auto shut off saves battery life.

GENERAL SPECIFICATIONS
Circuit Custom one-chip of micro- Operating Main instrument,
processor LSI circuit. Humidity Less than 80% R.H.
Display 51 mm x 32 mm, Power Supply 006P DC 9V battery
15 mm ( 0.6" ) digit size. ( Alkaline or Heavy duty type ).
dual function LCD display, Power Current Approx. DC 7 mA.
Measurement Humidity meter : Weight 250 g/0.55 LB (battery included).
R.H. ( Relative Humidity ) Main instrument:
Temperature - ℃, ℉. 195 x 68 x 30 mm
Dew point : ℃, ℉. ( 7.6 x 2.6 x 1.2 inch )
Type K thermometer Dimension Humidity Sensor Probe:
Sensor Humidity ( Dew Point ) meter : Round 26 mm Dia. x 160 mm.
Humidity : Instruction manual........... 1 PC.
High precision thin-film Accessories Humidity probe..................... 1 PC.
capacitance sensor. Carrying Case.................. 1 PC.
Temperature : Thermistor. 33% RH HUMIDITY CALIBRATPR
Type K thermometer : Optional Model: RHA-33
Thermocouple probe. Accessories 75% RH HUMIDITY CALIBRATPR
Data Hold By push button Model : RHA-75
Memory Recall Maximum & Minimum. Type k thermocouple Probe :
Sampling Time Approx. 0.8 second. TP-01, TP-02A, TP-03,
Power off Auto shut off, saves battery life, TP-04.
or manual off by push button. RS232 cable, UPCB-02
Data Output RS 232 PC serial interface. Application software,
Operating 0 to 50 ℃. SW-U801-WIN
Temperature Application software, sw-u801-WIN

ELECTRICAL SPECIFICATIONS ( 23 ± 5 ℃ )
Humidity/ Temperature
Range 10 % to 95 % R.H.
Humidity Resolution 0.1 % R.H.
Accuracy 70 % R.H. - ± ( 3 % reading + 1 % R.H.)
(after calibration) < 70 % R.H. - ± 3% R.H.
Range 0 ℃ to 50 ℃, 32 ℉ to 122 ℉.
Temperature Resolution 0.1
Accuracy ℃ - ± 0.8 ℃, ℉ - ± 1.5 ℉.
Dew Point
℃ Range -25.3 ℃ to 48.9 ℃
Resolution 0.1 ℃
℉ Range -13.5 ℉ to 120.1 ℉.
Resolution 0.1 ℉.
Remark :
* Dew Point display value is caculated from the Humidity/Temp. measurement automatically.
* The Dew Point accuracy is sum accuracy value of Humidity & Temperature measurement..
Type K Thermometer
Range Resolution Accuracy
℃ -100.0 to 1300.0 ℃ 0.1 ℃ -50.0 to 1300.0 ℃ : ±( 0.2 % + 0.5 ℃ )
-50.1 to -100.0 ℃ : ±( 0.2 % + 1℃)
℉ -148.0 to 2372.0 ℉ 0.1 ℉ -58.0 to 2372.0 ℉ : ±( 0.2 % + 1℉)
-58.1 to -148.0 ℉ : ±( 0.2 % + 1.8 ℉ )

THERMOCOUPLE PROBE (type K), optional


TP-01 -40 ℃ to 250 ℃ (300℃ short- term). TP-03 -50 ℃ to 1200 ℃ ( -50 ℉ to 2200 ℉).
Ultra fast response naked-bead probe. High temp., Penetration & immersion.
TP-02A -50 ℃ to 900 ℃ ( -50 ℉ to 1650 ℉). TP-04 -50 ℃ to 400 ℃ ( -50 ℉ to 752 ℉).
Penetration & Immersion applications. Precision surface temp. measurement usage.
* Appearance and specifications listed in this brochure are subject to change without notice. CAT-0403-HD3008