Last Modified: 2-7-2018 6.8:8.0.

48 Doc ID: RM000003E32003X

Model Year Start: 2010 Model: LX570 Prod Date Range: [07/2009 - ]

Title: METER / GAUGE / DISPLAY: COMBINATION METER: REMOVAL; 2010 MY LX570 [07/2009 - ]

REMOVAL
1. DISABLE AUTOAWAY/RETURN FUNCTION
(a) Disable the Autoaway/Return function by changing the customize parameter .

NOTICE:
Record the current customize parameter setting (whether the Autoaway/Return function is enabled or
disabled) in order to restore the current setting after finishing the operation.

HINT:
Performing the above operation causes the Autoaway/Return function to be disabled when the engine switch is
turned off.

(b) Turn the engine switch on (IG). Operate the tilt and telescopic switch to fully extend and lower the steering
column.

(c) Turn the engine switch off.

2. REMOVE ENGINE ROOM SIDE COVER LH

3. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
w/ Navigation System:

After the engine switch is turned off, the HDD navigation system requires approximately 6 minutes to
record various types of memory and settings. As a result, after turning the engine switch off, wait 6
minutes or more before disconnecting the cable from the negative (-) battery terminal.
When disconnecting the cable, some systems need to be initialized after the cable is reconnected .

4. REMOVE INSTRUMENT SIDE PANEL LH

(a) Place protective tape as shown in the illustration.

(b) Using a moulding remover, detach the 6 claws and remove the side panel.

5. REMOVE NO. 1 SWITCH HOLE BASE

(a) Detach the 5 claws.


(b) Remove the hole base and disconnect the connectors.

6. REMOVE LOWER INSTRUMENT PANEL PAD SUB-ASSEMBLY LH

(a) Detach the 8 claws.

(b) Remove the instrument panel pad and disconnect the connector.

7. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY

(a) Detach the 6 claws.

(b) Detach the 4 claws.

(c) Remove the finish panel and disconnect the connectors.


8. REMOVE NO. 1 INSTRUMENT PANEL REGISTER ASSEMBLY

(a) Detach the 4 claws and remove the register.

9. REMOVE NO. 3 INSTRUMENT PANEL REGISTER ASSEMBLY

(a) Detach the 5 claws and remove the register.

10. REMOVE COMBINATION METER ASSEMBLY

(a) Remove the 2 screws.

(b) Detach the 2 clips.

(c) Disconnect the connector and remove the combination meter.